Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radioisotopes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Towards the Stable Chelation of Radioantimony(V) for Targeted Auger Theranostics

Abstract Antimony‐119 ( 119 Sb) is one of the most attractive Auger‐electron emitters identified to date, but it remains practically unexplored for targeted radiotherapy because no chelators have been identified to stably bind this metalloid in vivo. In a departure from current studies focused on chelator development for Sb(III), we explore the chelation chemistry of Sb(V) using the tris‐catecholate ligand TREN‐CAM. Through a combination of radiolabeling, spectroscopic, solid‐state, and computational studies, the radiochemistry and structural chemistry of TREN‐CAM with 1XX/nat Sb(V) were established. The resulting [ 1XX Sb]Sb–TREN‐CAM complex remained intact for several days in human serum, signifying high stability under biological conditions. Finally, the first in vivo single photon emission computed tomography and positron emission tomography imaging studies were carried out using 117 Sb, the diagnostic analogue of 119 Sb. These studies revealed marked differences in the uptake and distribution of activity in mice administered unchelated [ 117 Sb]Sb(OH) 6 – versus [ 117 Sb]Sb–TREN‐CAM, suggesting that 117 Sb is largely retained by TREN‐CAM over the time course of the study. Collectively, these findings demonstrate the most physiologically stable complex of no‐carrier‐added 1XX Sb yet reported, offering new promise for the clinical implementation of radioantimony in nuclear medicine. Our results also establish the feasibility of 117 Sb as an elementally matched partner to 119 Sb for theranostic applications.

Olson, Aeli P. [Department of Medical Physics Univ↗

Experiments with a prototype titanium hot cavity surface ionization source intended for electromagnetic separation of radioactive samarium and other lanthanide elements

This paper reports experimental results of a prototype titanium surface ionization source. For the first time, a lanthanide ion beam has been produced with a surface ionizer composed completely of titanium metal. Titanium does not readily activate with neutron irradiation. This offers the potential for inserting an ion source made of titanium directly into a reactor with a pre-loaded non-radioactive lanthanide target. This seamlessly integrates target irradiation with isotope separation, eliminating post irradiation sample manipulation. Samarium ion beam currents up to 960 nA have been produced in an off-line test bench equipped with rudimentary beam optics. This is a crucial step toward the development of an ionization source adopted for the electromagnetic isotope separator (EMIS) facility, which has been designed for high throughput separations of radioactive 153 Sm and other lanthanides of interest in the field of nuclear medicine. The ion current and important factors affecting the performance of the ion source, such as the ionizer temperature and thermal gradient, are discussed. Lastly, the experimental results are presented together with a discussion of future modifications to optimize the overall surface ionization source performance.

07 ISOTOPE AND RADIATION SOURCES↗

Measurements of excitation functions and photoneutron cross sections of 96,98,99,104 Ru and 100 Mo

Photoneutron cross sections were extracted for isotopes of ruthenium and molybdenum on natural abundance targets via a reduced chi-squared analysis on excitation functions, or activation yields, as function of electron beam energy. Bremsstrahlung photons were produced via an electron linear accelerator and a tungsten radiator at the Idaho Accelerator Center. A total of 16 irradiations were performed with electron beam energies ranging from approximately 8 MeV to 23 MeV. Induced radioactivity was measured using a high purity germanium detector. The cross sections were extracted assuming a three parameter Lorentzian fit with a smooth truncated rise at reaction threshold.

07 - ISOTOPES AND RADIATION SOURCES↗

Recent 238 Pu Production Activities at Idaho National Laboratory

The Plutonium-238 ( 238 Pu) Production program at Idaho National Laboratory (INL) is actively qualifying irradiation targets containing 237 Np for the Advanced Test Reactor (ATR) to produce 238 Pu for future National Aeronautics and Space Administration missions. INL qualified and loaded seven targets in the ATR’s south flux trap for cycle 169A, which occurred in Spring 2021. The irradiation qualification program has expanded to additional ATR irradiation positions after two baseline production targets in three positions validated significant production of 238 Pu. The validation model was followed by the PFS-1 experimental test in the ATR Critical Facility that verified 238 Pu production cross sections. This paper outlines the progress and status of the 238 Pu production program at INL. The qualification effort, safety analysis, hardware status, and future activities for qualification of an updated target design for use in the ATR are discussed.

07 ISOTOPE AND RADIATION SOURCES↗

Computational Thermal Hydraulics of a High-Performance Low-Enriched-Uranium Annular Target for HFIR Irradiation

Molybdenum-99 has historically been generated via isolation from fissioned highly enriched uranium (HEU) targets. Here, this isotope is in high demand due to its daily use across the world in radiopharmaceutical medical procedures. The primary objective of this work was to design and analyze an experimental target assembly containing one low-enriched-uranium (LEU) annular target for irradiation at the High Flux Isotope Reactor (HFIR). Efforts included incorporating spatially dependent energy sources from neutron and gamma interactions, quantifying thermal contact conductance at material interfaces, performing grid-independent studies, comparing turbulence models, and simulating various steady-state and transient scenarios relevant for irradiation qualification and eventual insertion. These models provide velocity, pressure, and temperature distributions in both space and time. Such results enable the selection of an appropriate irradiation location, fission rate density, and flow-limiting orifice size and demonstrate compliance with HFIR safety requirements such that insertion into the reactor can be approved. This analysis shows that across all scenarios, wetted surface temperatures remain below the coolant saturation temperature with no net vapor formation in the coolant. In every scenario, all components stay below 30% of the aluminum 6061 melting temperature. Computational fluid dynamics and system-level models predict peak target temperatures that agree within 4%, though the predicted axial location of the peak differs by about 10% of the heated length due to differences in flow development length. These results de-risk the irradiation of LEU (annular targets) and strengthen a domestic, HEU-independent 99 Mo supply by providing important fuel performance data to form the foundation for a robust licensing basis.

Molybdenum-99↗

Laser cutting apparatus for high energy density and diamond anvil cell science

In this paper, we present a low-cost, high-resolution laser cutting system designed for use in the fabrication of samples for high energy density physics. Such samples are necessarily small but require precision and repeatability, particularly with the recently available high repetition rates possible at modern facilities. The system allows simultaneous laser cutting, using nanosecond near-infrared laser pulses, and optical microscopy so that the cut can be monitored in real time. The capabilities of the system are demonstrated on a range of materials for both laser-matter interaction targets and components for high pressure diamond anvil cell experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Positron sources: from conventional to advanced accelerator concepts-based colliders

Positron sources are the key elements for the future and current lepton collider projects such as ILC, CLIC, SuperKEKB, FCC-ee, Muon Collider/LEMMA, etc., introducing challenging critical requirements for high intensity and low emittance beams in order to achieve high luminosity. In fact, due to their large production emittance and constraints given by the target thermal load, the main collider parameters such as the peak and average current, the emittances, the damping time, the repetition frequency and consequently the luminosity are determined by the positron beam characteristics. In this work, the conventional positron sources and their main properties are explored for giving an indication to the challenges that apply during the design of the advanced accelerator concepts. The photon-driven positron sources as the novel approach proposed, primarily for the future linear colliders, are described highlighting their variety and problematic.

47 OTHER INSTRUMENTATION↗

On possibility of low-emittance high-energy muon source based on plasma wakefield acceleration

We report plasma wakefield acceleration (PWA) channels are characterized by very high accelerating gradients and very strong focusing fields. We propose to employ these properties for effective production of low emittance high energy muon beams, consider muon beam dynamics in the PWFA cell and analyze various options and potential of the PWA-based muon sources.

43 PARTICLE ACCELERATORS↗

Target development using the method of High-Intensity Vibrational Powder Plating (HIVIPP) at the Center for Accelerator Target Science (CATS) at Argonne National Laboratory (ANL)

One of the primary goals of the Center for Accelerator Target Science (CATS) is to provide targets and foils in support of the ATLAS User Facility and the Low-Energy community at large. While a wide array of target production techniques are available at CATS, new methods that must be explored invariably arise. One such technique, the High-Intensity Vibrational Powder Plating (HIVIPP), was first reported in 1997 by Isao Sugai. It was developed to produce targets and stripper foils that were difficult to make by standard methods. At Argonne National Laboratory (ANL), we have successfully constructed and tested a simple system for this purpose. We have produced targets of carbon and titanium on various metal backings using the HIVIPP method. We are currently in the exciting phase of exploring the production of other elements, including isotopically enriched and radioactive material. This work is in progress and will be further detailed with specific examples.

47 OTHER INSTRUMENTATION↗

Physical thickness characterization of the FRIB production targets

The FRIB heavy-ion accelerator, commissioned in 2022, is a leading facility for producing rare isotope beams (RIBs) and exploring nuclei beyond the limits of stability. These RIBs are produced via reactions between stable primary beams and a graphite target. Approximately 20–40% of the primary beam power is deposited in the target, requiring efficient thermal dissipation. Currently, FRIB operates with a primary beam power of up to 20 kW. To enhance thermal dissipation efficiency, a single-slice rotating graphite target with a diameter of approximately 30 cm is employed. The effective target region is a 1 cm-wide outer rim of the graphite disc. To achieve high RIB production rates, the areal thickness variation must be constrained within 2%. This paper presents physical thickness characterizations of FRIB production targets with various nominal thicknesses, measured using a custom-built non-contact thickness measurement apparatus.

Instrumentation for radioactive beams (fragmentati↗

Electromagnetic and Engineering Design of a High-Current 15-MeV/u Cyclotron

The capability to produce high current, low loss, and extracted external ion beams presents an enabling technology for nuclear security, isotope production, and medical applications. We report on a novel, continuous-wave cyclotron for accelerating light ions with a charge-to-mass ratio of 1/2, which is designed for 1 mA maximum and 15 MeV/u energy. This article details the conceptual electromagnetic (EM) and engineering design including the 1.1 T sector magnets and 45 MHz, 200 kV radio frequency (RF) cavities. We discuss the cyclotron beam parameters with respect to potential commercial and industrial applications. The general concept and the accelerator’s layout are followed by a detailed EM design of magnets and RF cavities. Finally, practical engineering design considerations will be provided.

07 ISOTOPE AND RADIATION SOURCES↗