Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ABLATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Numerical studies of wall–plasma interactions and ionization phenomena in an ablative pulsed plasma thruster

Wall–plasma interactions excited by ablation controlled arcs are very critical physical processes in pulsed plasma thrusters (PPTs). Their effects on the ionization processes of ablated vapor into discharge plasma directly determine PPT performances. To reveal the physics governing the ionization phenomena in PPT discharge, a modified model taking into account the pyrolysis effect of heated polytetrafluoroethylene propellant on the wall–plasma interactions was developed. The feasibility of the modified model was analyzed by creating a one-dimensional simulation of a rectangular ablative PPT. The wall–plasma interaction results based on this modified model were found to be more realistic than for the unmodified model; this reflects the dynamic changes of the inflow parameters during discharge in our model. Furthermore, the temporal and spatial variations of the different plasma species in the discharge chamber were numerically studied. The numerical studies showed that polytetrafluoroethylene plasma was mainly composed of monovalent ions; carbon and fluorine ions were concentrated in the upstream and downstream discharge chamber, respectively. The results based on this modified model were in good agreement with the experimental formation times of the various plasma species. A large number of short-lived and highly ionized carbon and fluorine species (divalent and trivalent ions) were created during initial discharge. These highly ionized species reached their peak density earlier than the singly ionized species.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nonintrusive manufactured solutions for ablation

The study of heat transfer and ablation plays an important role in many problems of scientific and engineering interest. As with the computational simulation of any physical phenomenon, the first step toward establishing credibility in ablation simulations involves code verification. Code verification is typically performed using exact and manufactured solutions. However, manufactured solutions generally require the invasive introduction of an artificial forcing term within the source code such that the code solves a modified problem for which the solution is known. In this paper, we present a nonintrusive method for manufacturing solutions for a non-decomposing ablation code, which does not require the addition of a source term.

42 ENGINEERING↗

Spatio-temporal ablation dynamics and plasma chemistry of aluminum induced by temporally modulated ytterbium fiber laser

Here, in this work, we studied single-pulse ablation dynamics of a temporally modulated continuous wave laser-material interaction with Al using in situ multimodal time-resolved diagnostics that describe in detail the associated physical and chemical processes. Time-resolved scattering, emission imaging, and optical emission spectroscopy unveiled a sequence of events spread out across three distinct phases: (i) early phase ablation process, associated with particle generation and liquid Al column formation (<20 μs), (ii) secondary detonation when sufficient ejected material is accumulated over the surface (20-50 μs), and (iii) molten liquid Al pool oscillation on the surface, followed by large droplet ejection from the liquid pool (100-500 μs). Atomic Al and AlO were observed with optical emission spectroscopy at different ratios during the entire lifetime of the event, verifying the formation of oxidized Al vapor upon its interaction with air. Morphological and compositional characterization confirmed surface oxidation and material re-solidification in the form of protrusions produced during the irradiation process. This work provides insights into the complex physical and chemical mechanisms of single-pulse ablation in the sub-millisecond laser pulse regime, which are critically important for parameter optimization in a variety of laser processing, microfabrication, and deposition applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fast imaging of laser ablation of cerium: Dependence of plasma plume dynamics and structure on native oxide growth

We have imaged the evolution of plasma following nanosecond pulsed laser ablation of cerium in air with sub-10 ns resolution. We find the ablated plasma plume expansion and shape to be strongly dependent on the time after mechanical polishing of the sample surface. After an initial shock front common to both new and aged samples (velocities up to 16 km s ₋1 ), we observe a second front that is relatively localized to the surface vicinity of newly polished samples, but in the case of older samples it moves outward at velocities of up to 4 km s ₋1 . We attribute this behavior to the formation and growth of a native oxide layer on the order of hours after polishing. These results demonstrate that plasma imaging can be used to diagnose the presence of, and evaluate the extent of, thin surface oxides or other compounds that form soon after exposure to some atmosphere. These findings also highlight the need to explicitly consider the presence of such overlayers when modeling laser/metal interaction, when making measurements of vapor phase chemistry, and when analyzing the composition, phase, and morphology of solid particulates formed after the ablation of reactive metals.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of an ultrafast wide-field microscope for single-shot laser-driven shock and ablation studies

We build an ultrafast wide-field microscope that captures single-shot events at near-optical diffraction limit for time-resolved studies of ablation and shock compression. Here, we provide insights on how the imaging and spectroscopic modalities of our single-shot microscope are impacted by the depth of field of a microscope objective. At high spatial resolution, the depth of field can critically impede these experiments and novel strategies must be implemented to acquire high-quality optical micrographs at high throughput. Here, we highlight how custom lithography-prepared samples enable us to rectify optical artifacts that arise during sample motion. With a complete knowledge of how the mechanical and optical components couple together, we can then extract critical spatial and temporal features of our ablation and shock compression experiments. For example, during the ablation processes, we show that shock waves created in metal thin films form Newton’s interference rings, whose evolution can be recorded with picosecond temporal resolution and at near optical diffraction-limit resolution.

Ultrafast microscopy↗

Optimizing ablator thickness for laser shock experiments

In laser shock experiments, a well-defined, flat-top shock wave at the ablator/sample interface is important for accurately probing material response under uniaxial strain compression. However, the relationship between the ablator thickness and the resulting shock wave characteristics is insufficiently understood, limiting the ability to design optimal experiments. To address this need, we conducted a systematic experimental study using a 100 J laser to shock-compress polyimide ablators to peak stresses ranging from 20.4 to 111.6 GPa. Laser interferometry diagnostics measured the transmitted wave profiles at the ablator/sample interface, consistently showing a single jump followed by a constant peak state before the arrival of release waves. Here, by analyzing shock transit time, flat-top duration, and stress, our results establish a framework for selecting ablator thickness to maximize the flat-top duration, improving the precision and reproducibility of laser shock experiments.

design of experiments↗

Specific features of single-pulse femtosecond laser micron and submicron ablation of a thin silver film coated with a micron-thick photoresist layer

Specific features of ablation of a thin silver film with a 1-μm-thick layer of a highly transparent photoresist and the same film without a photoresist layer under single tightly focused femtosecond laser pulses in the visible range (515 nm) are experimentally investigated. Interference effects of internal modification of the photoresist layer, its spallation ablation from the film surface and formation of through hollow submicron channels in the resist without its spallation but with ablation of the silver film lying under the resist are found and discussed. (extreme light fields and their applications)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Spectral features of colloidal solutions of elongated gold nanoparticles produced by laser ablation in aqueous solutions

The extinction spectra of colloidal solutions of gold nanoparticles produced by laser ablation in water and aqueous solutions of salts using two near-IR lasers with pulse durations of 200 ns and 1 ps are experimentally investigated. The extinction spectrum of the particles formed by ablation in aqueous solutions is characterised by enhanced optical density in the red and IR regions. This feature is due to the formation of elongated gold nanoparticles, as confirmed by transmission electron microscopy. The surface images of a gold target subjected to multipulse laser ablation exhibit micron and submicron structures. (nanophotonics)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

EJECTA KNOT FLICKERING, MASS ABLATION, AND FRAGMENTATION IN CASSIOPEIA A

Ejecta knot flickering, ablation tails, and fragmentation are expected signatures associated with the gradual dissolution of high-velocity supernova (SN) ejecta caused by their passage through an inhomogeneous circumstellar medium or interstellar medium (ISM). Such phenomena mark the initial stages of the gradual merger of SN ejecta with and the enrichment of the surrounding ISM. Here we report on an investigation of this process through changes in the optical flux and morphology of several high-velocity ejecta knots located in the outskirts of the young core-collapse SN remnant Cassiopeia A using Hubble Space Telescope images. Examination of WFPC2 F675W and combined ACS F625W + F775W images taken between 1999 June and 2004 December of several dozen debris fragments in the remnant's northeast ejecta stream and along the remnant's eastern limb reveal substantial emission variations ('flickering') over timescales as short as nine months. Such widespread and rapid variability indicates knot scale lengths {approx_equal} 10{sup 15} cm and a highly inhomogeneous surrounding medium. We also identify a small percentage of ejecta knots located all around the remnant's outer periphery which show trailing emissions typically 0.''2-0.''7 in length aligned along the knot's direction of motion suggestive of knot ablation tails. We discuss the nature of these trailing emissions as they pertain to ablation cooling, knot disruption, and fragmentation, and draw comparisons to the emission 'strings' seen in {eta} Car. Finally, we identify several tight clusters of small ejecta knots which resemble models of shock-induced fragmentation of larger SN ejecta knots caused by a high-velocity interaction with a lower density ambient medium.

79 ASTRONOMY AND ASTROPHYSICS↗

In situ studies of a molten metal anode ablation in a nearly atmospheric pressure DC arc

A DC arc with a meltable metal anode in a near-atmospheric pressure hydrocarbon gas is an emerging method for producing single-walled carbon nanotubes (SWCNTs). In these systems, evaporation of the molten metal anode determines the formation of catalyst seed particles needed for SWCNT growth, and therefore, should be monitored, controlled, and optimized. Evaluating the anode ablation rate by weighing the anode before and after a synthesis run is unfeasible due to anode carburization in the hydrocarbon atmosphere. To overcome this, we implemented a high-speed, 2D, 2-color pyrometry for reliable temperature measurements of the molten anode in a DC arc. The obtained temperature fields were used to calculate the anode ablation rates. Results showed the importance of resolving the arc and molten pool dynamics, as well as addressing the issue of reflections. Furthermore, significant changes in ablation rates were revealed upon addition of CH 4 , which must be considered when scaling up the production of SWCNTs.

Marangoni↗

External Magnetic Field Effects on Ablation of Current-Driven Foils Using an Extended Magnetohydrodynamics Simulation

We numerically model the ablation process of a 25-μm-thick aluminum foil driven by a pulsed-power machine that provides a 1-MA peak current in a 100-ns zero-to-peak rise time. The extended magnetohydrodynamics simulation is a discontinuous Galerkin code with Cartesian coordinates in 3-D and with 25-μm spatial resolution. We investigate here the influence of an external magnetic field normal to the foil surface, B z . During the foil ablation, B z = 1 T causes more nonuniform distributions of density and current compared to B z = 0 T. B z = 4 T delays the generation of surface plasma relative to the 0- and 1-T cases. The understanding of a material's ablation as it undergoes transition from the solid to plasma phases requires detailed knowledge of a material's equation of state and conductivity. This paper of warm dense matter and how instabilities propagate from a solid material to plasma motivates improvements to both numerical simulations and experimental diagnostics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Model-based feasibility assessment and evaluation of prostate hyperthermia with a commercial MR-guided endorectal HIFU ablation array

Purpose: Feasibility of targeted and volumetric hyperthermia (40–45 °C) delivery to the prostate with a commercial MR-guided endorectal ultrasound phased array system, designed specifically for thermal ablation and approved for ablation trials (ExAblate 2100, Insightec Ltd.), was assessed through computer simulations and tissue-equivalent phantom experiments with the intention of fast clinical translation for targeted hyperthermia in conjunction with radiotherapy and chemotherapy. Methods: The simulations included a 3D finite element method based biothermal model, and acoustic field calculations for the ExAblate ERUS phased array (2.3 MHz, 2.3 × 4.0 cm{sup 2}, ∼1000 channels) using the rectangular radiator method. Array beamforming strategies were investigated to deliver protracted, continuous-wave hyperthermia to focal prostate cancer targets identified from representative patient cases. Constraints on power densities, sonication durations and switching speeds imposed by ExAblate hardware and software were incorporated in the models. Preliminary experiments included beamformed sonications in tissue mimicking phantoms under MR temperature monitoring at 3 T (GE Discovery MR750W). Results: Acoustic intensities considered during simulation were limited to ensure mild hyperthermia (T{sub max} < 45 °C) and fail-safe operation of the ExAblate array (spatial and time averaged acoustic intensity I{sub SATA} < 3.4 W/cm{sup 2}). Tissue volumes with therapeutic temperature levels (T > 41 °C) were estimated. Numerical simulations indicated that T > 41 °C was calculated in 13–23 cm{sup 3} volumes for sonications with planar or diverging beam patterns at 0.9–1.2 W/cm{sup 2}, in 4.5–5.8 cm{sup 3} volumes for simultaneous multipoint focus beam patterns at ∼0.7 W/cm{sup 2}, and in ∼6.0 cm{sup 3} for curvilinear (cylindrical) beam patterns at 0.75 W/cm{sup 2}. Focused heating patterns may be practical for treating focal disease in a single posterior quadrant of the prostate and diffused heating patterns may be useful for heating quadrants, hemigland volumes or even bilateral targets. Treatable volumes may be limited by pubic bone heating. Therapeutic temperatures were estimated for a range of physiological parameters, sonication duty cycles and rectal cooling. Hyperthermia specific phasing patterns were implemented on the ExAblate prostate array and continuous-wave sonications (∼0.88 W/cm{sup 2}, 15 min) were performed in tissue-mimicking material with real-time MR-based temperature imaging (PRFS imaging at 3.0 T). Shapes of heating patterns observed during experiments were consistent with simulations. Conclusions: The ExAblate 2100, designed specifically for thermal ablation, can be controlled for delivering continuous hyperthermia in prostate while working within operational constraints.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Atomistic simulation of laser ablation of gold: Effect of pressure relaxation

The process of ablation of a gold target by femto- and picosecond laser radiation pulses has been studied by numerical simulations using an atomistic model with allowance for the electron subsystem and the dependence of the ion-ion interaction potential on the electron temperature. Using this potential, it is possible to take into account the change in the physical properties of the ion subsystem as a result of heating of the electron subsystem. The results of simulations reveal a significant difference between the characteristics of metal ablation by laser pulses of various durations. For ablation with subpicosecond pulses, two mechanisms of metal fracture related to the evolution of electronic pressure in the system are established.

74 ATOMIC AND MOLECULAR PHYSICS↗

Surface Modification of ICF Target Capsules by Pulsed Laser Ablation

Topographical modifications of spherical surfaces are imprinted on National Ignition Facility (NIF) target capsules by extending the capabilities of a recently developed full surface (4π) laser ablation and mapping apparatus. The laser ablation method combines the precision, energy density and long reach of a focused laser beam to pre-impose sinusoidal modulations on the outside surface of High Density Carbon (HDC) capsules and the inside surface of Glow Discharge Polymer (GDP) capsules. Sinusoidal modulations described in this paper have sub-micron to 10’s of microns vertical scale and wavelengths as small as 30 μm and as large as 200 μm. The modulated patterns are created by rastering a focused laser fired at discrete capsule surface locations for a specified number of pulses. The computer program developed to create these raster patterns uses inputs such as laser beam intensity profile, the material removal function, the starting surface figure and the desired surface figure. The patterns are optimized to minimize surface roughness. Lastly, in this paper, simulated surfaces are compared with actual ablated surfaces measured using confocal microscopy.

36 MATERIALS SCIENCE↗

Deep Dive Topic: Choosing between ablators

Recent data on implosions using identical hohlraums and very similar laser drives underscores the conundrum of making a clear choice of one ablator over another. Table I shows a comparison of Be and CH in a nominal length, gold, 575 μm-diameter, 1.6 mg/cc He gas-fill hohlraum while Table II shows a comparison of undoped HDC and CH in a +700 length, gold, 575 μm diameter, 1.6 mg/cc He gas fill hohlraum. As can be seen in the tables, the net integrated fusion performance of these ablators is the same to within error bars. In the case of the undoped HDC and CH ablators, the hot spot shapes of the implosions were nearly indistinguishable for the experiments listed in Table II.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Selective Laser Ablation in Resists and Block Copolymers for High Resolution Lithographic Patterning

Previously, we demonstrated an all dry, selective laser ablation development in methyl acetoxy calixarene (MAC6) which produced high resolution (15-25 nm half-pitch), high aspect ratio features not achievable with wet development. In this paper, we investigate the selective laser ablation process as a means to create a block copolymer derived lithographic pattern through the selective removal of one block. Two block copolymer systems were investigated PS-b-PHOST, and P2VP-b-PS-b-P2VP. The selective laser ablations process on block copolymers offers an alternative to plasma etching when plasma etching is not effective.

36 MATERIALS SCIENCE↗

Experimental Simulation of Meteorite Ablation during Earth Entry Using a Plasma Wind Tunnel

Three different types of rocks were tested in a high enthalpy air plasma flow. Two terrestrial rocks, basalt and argillite, and an ordinary chondrite, with a 10 mm diameter cylindrical shape were tested in order to observe decomposition, potential fragmentation, and spectral signature. The goal was to simulate meteoroid ablation to interpret meteor observation and compare these observations with ground based measurements. The test flow with a local mass-specific enthalpy of 70 MJ kg{sup −1} results in a surface heat flux at the meteorite fragment surface of approximately 16 MW m{sup −2}. The stagnation pressure is 24 hPa, which corresponds to a flight condition in the upper atmosphere around 80 km assuming an entry velocity of 10 km s{sup −1}. Five different diagnostic methods were applied simultaneously to characterize the meteorite fragmentation and destruction in the ground test: short exposure photography, regular video, high-speed imaging with 10 kHz frame rate, thermography, and Echelle emission spectroscopy. This is the first time that comprehensive testing of various meteorite fragments under the same flow condition was conducted. The data sets indeed show typical meteorite ablation behavior. The cylindrically shaped fragments melt and evaporate within about 4 s. The spectral data allow the identification of the material from the spectra which is of particular importance for future spectroscopic meteor observations. For the tested ordinary chondrite sample a comparison to an observed meteor spectra shows good agreement. The present data show that this testing methodology reproduces the ablation phenomena of meteoritic material alongside the corresponding spectral signatures.

79 ASTRONOMY AND ASTROPHYSICS↗

Superselective Particle Embolization Enhances Efficacy of Radiofrequency Ablation: Effects of Particle Size and Sequence of Action

Purpose. To evaluate the effects of particle size and course of action of superselective bland transcatheter arterial embolization (TAE) on the efficacy of radiofrequency ablation (RFA). Methods. Twenty pigs were divided into five groups: group 1a, 40-{mu}m bland TAE before RFA; group 1b, 40-{mu}m bland TAE after RFA; group 2a, 250-{mu}m bland TAE before RFA; group 2b, 250-{mu}m bland TAE after RFA and group 3, RFA alone. A total of 40 treatments were performed with a combined CT and angiography system. The sizes of the treated zones were measured from contrast-enhanced CTs on days 1 and 28. Animals were humanely killed, and the treated zones were examined pathologically. Results. There were no complications during procedures and follow-up. The short-axis diameter of the ablation zone in group 1a (mean {+-} standard deviation, 3.19 {+-} 0.39 cm) was significantly larger than in group 1b (2.44 {+-} 0.52 cm; P = 0.021), group 2a (2.51 {+-} 0.32 cm; P = 0.048), group 2b (2.19 {+-} 0.44 cm; P = 0.02), and group 3 (1.91 {+-} 0.55 cm; P < 0.001). The greatest volume of ablation was achieved by performing embolization with 40-{mu}m particles before RFA (group 1a; 20.97 {+-} 9.65 cm{sup 3}). At histology, 40-{mu}m microspheres were observed to occlude smaller and more distal arteries than 250-{mu}m microspheres. Conclusion. Bland TAE is more effective before RFA than postablation embolization. The use of very small 40-{mu}m microspheres enhances the efficacy of RFA more than the use of larger particles.

62 RADIOLOGY AND NUCLEAR MEDICINE↗