Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Comparing and contrasting In-Vial and full-scale systems for sparging volatile analytes

Here, in-vial sparging was demonstrated as an effective, practical alternative to a full-scale sparging system for supporting the analysis of volatile constituents. Using elemental mercury (Hg 0 ) and toluene as representative purgeable analytes, the mass removal for various sparge configurations was measured and a reduced order model was developed and validated. In the primary experiments, Hg 0 in the sparge gas was trapped on activated carbon or gold, thermally desorbed, and quantified using atomic absorption or atomic fluorescence spectroscopy. Toluene experiments using the same in-vial sparge apparatus and sparge parameters were performed to demonstrate the applicability of the reduced order model to a broad range of compounds. Toluene removal was tracked by measuring the remaining toluene in sparged aliquots using Ultraviolet-visible (UV–Vis) spectroscopy. For the sparging, flow rates varied from 25 to 75 mL/min for periods from 0 to 30 min. Sparge performance, mass removal as a function of time, and sparge gas volume were measured for both in-vial and full-scale systems. A model based on dimensionless Henry's Law coefficient, normalized sparge gas volume, and fractional extent of equilibrium matched the experimental data for both compounds and provides a practical tool for future applications. For the conditions tested in this study, the calibrated model indicated that the sparge gas in the in-vial system reached approximately 33% of its equilibrium value before exiting the water surface, while a full-scale system reached approximately 100%. The tests validated the quality, reproducibility, and predictability of sparging performance for both full scale and in-vial sparge systems. Related factors such as waste generation, worker risk, and labor were also assessed. Full scale sparge systems provide the advantage of lower detection levels due to larger sample volume, while the in-vial sparge systems provide advantages for most other factors; including automatability, reducing secondary wastes, lessening the need to clean and check the sparge apparatus, and lowering labor and costs. The data and associated reduced order model support continued development and deployment of in-vial sparge platforms as a practical option for analysis of purgeable analytes such as volatile organic compounds and volatile metals/organometallics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Automated Calibration of Parallel and Distributed Computing Simulators: A Case Study

Many parallel and distributed computing research results are obtained in simulation, using simulators that mimic real-world executions on some target system. Each such simulator is configured by picking values for parameters that define the behavior of the underlying simulation models it implements. The main concern for a simulator is accuracy: simulated behaviors should be as close as possible to those observed in the real-world target system. This requires that values for each of the simulator's parameters be carefully picked, or “calibrated,” based on ground-truth real-world executions. Examining the current state of the art shows that simulator calibration, at least in the field of parallel and distributed computing, is often undocumented (and thus perhaps often not performed) and, when documented, is described as a labor-intensive, manual process. In this work we evaluate the benefit of automating simulation calibration using simple algorithms. Specifically, we use a real-world case study from the field of High Energy Physics and compare automated calibration to calibration performed by a domain scientist. Our main finding is that automated calibration is on par with or significantly outperforms the calibration performed by the domain scientist. Furthermore, automated calibration makes it straightforward to operate desirable tradeoffs between simulation accuracy and simulation speed.

Mc donald, Jesse↗

Hierarchical multi-time-scale predictive thermal management and fuel optimization for heavy-duty compression ignition engines

For heavy-duty diesel engines, NO X emissions reduction is strongly constrained by fuel efficiency. This paper presents a hierarchical model predictive controller (H-MPC) for coordinated control of tailpipe NO X emissions and fuel consumption. The H-MPC uses the separation of slow and fast dynamics that exist in the engine and its aftertreatment system. The controller is synthesized with an architecture in which a high-level MPC uses a longer prediction horizon compared to the low-level predictive controller which tracks the high-level controller command and manages the thermal dynamics of the aftertreatment system. Engine load preview enables the high-level controller to estimate the desired catalyst temperature ahead of time and addresses the selective catalytic reduction (SCR) slow thermal dynamics. Calculated by the high-level controller, the intake manifold pressure, and the start of injection (SOI) crank angle is used as reference trajectories in the low-level controller that regulates fast dynamical behaviors such as engine out NO X emissions. Hardware-in-the-loop (HIL) validation of this integrated H-MPC on a rapid prototype controller shows that when the SCR catalyst temperature is above light-off temperature (warmed-up condition), the engine operation is shifted to operate with the best fuel economy since the warmed-up SCR can efficiently reduce the engine-out NO X emissions. Results indicate that up to 0.8% benefit in cycle averaged BSFC along with a 13% reduction in tailpipe NO X compared to a stock engine calibration can be achieved with the coordinated engine and aftertreatment system through H-MPC.

Engineering↗

Better calibration of cloud parameterizations and subgrid effects increases the fidelity of the E3SM Atmosphere Model version 1

Abstract. Realistic simulation of the Earth's mean-state climate remains a major challenge, and yet it is crucial for predicting the climate system in transition. Deficiencies in models' process representations, propagation of errors from one process to another, and associated compensating errors can often confound the interpretation and improvement of model simulations. These errors and biases can also lead to unrealistic climate projections and incorrect attribution of the physical mechanisms governing past and future climate change. Here we show that a significantly improved global atmospheric simulation can be achieved by focusing on the realism of process assumptions in cloud calibration and subgrid effects using the Energy Exascale Earth System Model (E3SM) Atmosphere Model version 1 (EAMv1). The calibration of clouds and subgrid effects informed by our understanding of physical mechanisms leads to significant improvements in clouds and precipitation climatology, reducing common and long-standing biases across cloud regimes in the model. The improved cloud fidelity in turn reduces biases in other aspects of the system. Furthermore, even though the recalibration does not change the global mean aerosol and total anthropogenic effective radiative forcings (ERFs), the sensitivity of clouds, precipitation, and surface temperature to aerosol perturbations is significantly reduced. This suggests that it is possible to achieve improvements to the historical evolution of surface temperature over EAMv1 and that precise knowledge of global mean ERFs is not enough to constrain historical or future climate change. Cloud feedbacks are also significantly reduced in the recalibrated model, suggesting that there would be a lower climate sensitivity when it is run as part of the fully coupled E3SM. This study also compares results from incremental changes to cloud microphysics, turbulent mixing, deep convection, and subgrid effects to understand how assumptions in the representation of these processes affect different aspects of the simulated atmosphere as well as its response to forcings. We conclude that the spectral composition and geographical distribution of the ERFs and cloud feedback, as well as the fidelity of the simulated base climate state, are important for constraining the climate in the past and future.

54 ENVIRONMENTAL SCIENCES↗

Effects of delta ray electrons on measurement uncertainties of harp system

A harp system, which is a multi-wire beam profile monitoring (MWPM) system, is planned upstream of the spallation target to make in situ calibration of beam current density configuration on the target along with beam imaging from luminescent coating on the beam entrance window at the Second Target Station (STS) of the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL). This beam interception-based beam diagnostics system on the target will be used to ensure that the maximum beam loads on the target are within the design range during neutron production. Current design of the harp consists of three layers of measurement wires each of which is sandwiched between voltage biasing wire planes. The signal obtained from each measurement wire layer is disturbed by secondary electrons (SE) and delta rays produced by beam-matter interactions in neighboring wires and ionization of residual gases in accelerator vacuum. While the backgrounds from SE can be suppressed by voltage biasing, the delta-ray electrons with kinetic energies above keV ranges overcome the electric potential bias. In this paper, we study the effects of delta-rays on the measurement uncertainties of MWPM using the particle transport simulation code FLUKA. Furthermore, the cases where the harp system is installed in the proximity of a large delta ray sources such as proton beam window or in the core vessel filled with sub-atmospheric gas have been studied.

Lee, Yong Joong↗

Autonomous Radiation Mapping and Quantification using an Unmanned Ground Vehicle. Part I - Environment Mapping

When characterizing facilities, advanced autonomous systems are safe, efficient, and cost-effective tools, which can safely deploy state-of-the-art instrumentation without exposing workers to radiation risks. One main focus of the research is the visual mapping of the environment.This paper presents a framework for the mapping aspect that utilizes lidar and SLAM technologies coupled with a monocular camera to create a point cloud of the environment. Upon completion, the present research work aims to provide an autonomous mobile robot the capability to localize itself and aid the user with visualizing the radiation data. Challenges: C++ node needs to properly synchronize image and point cloud data. 3D lidar has resolution of ± 3 cm. Proper camera calibration needed. Transforms need to be precise for proper alignment of image and point-cloud. Results: Voxelated point clouds. Accurate colors from calibrated cameras including details smaller than lidar resolution. Developed Robotics Operating System (ROS) package for ease of transfer to other robot platforms.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Metrological Guidance for the Calibration of Laboratory Glassware

This report provides technical guidance for the calibration of laboratory glassware to help the practitioner achieve traceability to the International System of Units and meet customer quality requirements. The discussion of traceability uses the National Institute of Standards and Technology’s seven essential elements of traceability as a framework. The guidance also includes how to determine when calibration is necessary, practical tips, and helpful references.

42 ENGINEERING↗

Constraints on Future Analysis Metadata Systems in High Energy Physics

In high energy physics (HEP), analysis metadata comes in many forms—from theoretical cross-sections, to calibration corrections, to details about file processing. Correctly applying metadata is a crucial and often time-consuming step in an analysis, but designing analysis metadata systems has historically received little direct attention. Among other considerations, an ideal metadata tool should be easy to use by new analysers, should scale to large data volumes and diverse processing paradigms, and should enable future analysis reinterpretation. This document, which is the product of community discussions organised by the HEP Software Foundation, categorises types of metadata by scope and format and gives examples of current metadata solutions. Important design considerations for metadata systems, including sociological factors, analysis preservation efforts, and technical factors, are discussed. A list of best practices and technical requirements for future analysis metadata systems is presented. These best practices could guide the development of a future cross-experimental effort for analysis metadata tools.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Yes, No, Maybe So: Human Factors Considerations for Fostering Calibrated Trust in Foundation Models Under Uncertainty

High-stakes analytical environments require analysts to evaluate evidence and generate conclusions to inform critical decisions often under conditions of uncertainty. Probabilistic decision-making based on incomplete or inaccurate information can reduce productivity, compromise national interests, and endanger public safety. Researchers are developing expert systems built on foundation models (FMs) to support analysts’ decision-making processes by enabling human-artificial intelligence (AI) teaming, in part through the quantification and expression of uncertainty information. As FMs continue to mature, it is imperative to correspondingly consider analysts’ needs for appropriately interpreting and using uncertainty information. However, prior research indicates that it remains unclear how analysts engage with FM-generated uncertainty information and the extent to which these interactions influence trust in, and reliance on, expert systems. We plan to review the state of the science and conduct an exploratory, qualitative study to (a) understand how properly communicated uncertainty can foster calibrated trust and appropriate reliance and (b) identify approaches for effectively conveying FM-generated uncertainty information during analytical workflows. We will administer semi-structured interviews with analysts from a specific high-stakes analytical environment to collect their current experiences with job-related uncertainty and their impressions when viewing FM-generated uncertainty information. During the interview protocol, participants will be presented with several different FM outputs and invited to discuss their thoughts and beliefs about the uncertainty information displayed. Participants may provide insights into how trust and reliance may be influenced by uncertainty. The results of this study will help us to better understand how analysts currently interpret and use uncertainty information. Our findings may inform human factors recommendations for effectively conveying uncertainty information to foster calibrated trust in, and appropriate reliance on, expert systems. Interaction designers and FM developers can use this knowledge to enhance human-AI teaming and ensure the responsible deployment of FM-based expert systems in analytical workflows.

97 MATHEMATICS AND COMPUTING↗

Improved temperature control for measuring the humidity dependence of aerosol optical properties

Aerosols impact climate and cloud formation by their ability to take up water, which leads to changes in their optical properties. To better characterize the interactions of aerosol with water vapor, a humidification section has been added to the Cavity Attenuation Phase-shift Spectrometry (CAPS) instrument. The CAPS is a diode based method that provides simultaneous measurements of both aerosol total optical extinction and scattering in real-time. We are improving the humidity controlled sample line with new temperature controls. The current system suffers from particlelosses and poorly controlled humidity profiles, both of which were corrected for in the systems redesign. This improved wet-CAPS system has been integrated with a dry-CAPS to simultaneously measure the wet and dry aerosol optical properties. The two CAPS monitors were operated in a dry collection mode to ensure there were no biases between the instruments. Initial calibrations and data were collected to test the functionality of the dual CAPS system (wet + dry). The new two channel CAPS system improves our ability to measure the effects of humidity on aerosol optical properties.

58 GEOSCIENCES↗

High-Accuracy and High-Stability Fiber-Optic Temperature Sensors for Coal Fired Advanced Energy

A research team at Michigan State University, led by Dr. Ming Han, has developed a revolutionary fiber-optic thermometer for use in next-generation coal-fired power plants. Funded by the U.S. Department of Energy, this new sensor is designed to measure extremely high temperatures with unmatched accuracy and long-term stability. Unlike conventional optical sensors that can give false readings due to mechanical strain and often drift out of calibration at high heat, this new technology uses a sealed gas chamber as its core. By measuring the temperature-dependent properties of the gas (air or argon), the sensor’s readings remain absolute and reliable, completely unaffected by the physical stresses on the surrounding equipment. The breakthrough design eliminates the need for complex and costly correction systems. It represents a fundamental shift in sensing technology, paving the way for a primary thermometer that maintains calibration and provides foundational accuracy essential for advanced energy systems.

01 COAL, LIGNITE, AND PEAT↗

Methods—A Practical Approach to the Reversible Hydrogen Electrode Scale

Accurately quantifying applied potential is important to ensuring the comparability, accuracy, and precision of electrochemical studies. Reference electrodes (REs) enable knowledge/determination of the applied potential at electrodes in electrochemical systems. Ultimately, the choice of RE will depend on the particular requirements of a given electrochemical system, however, we note it is imperative to ensure the accuracy of the RE potential and its proper translation to a standardized scale. In this work, we highlight that while there are many commercially available REs, these must be experimentally calibrated to a reliable and practical standard potential scale, for instance the reversible hydrogen electrode (RHE) scale for aqueous systems. With representative data, we provide streamlined instructions on how to calibrate any RE to the RHE scale. We also provide guidance to mitigate and/or avoid possible electrolyte contamination issues arising from REs. Moreover, we offer a step-by-step guide on how to build a practical RHE RE, which may be a suitable and desirable option in certain applications. Our work emphasizes the need for the continuous adoption of standardized reference potential scales and demonstrates the versatility of the RHE scale, particularly in aqueous electrochemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Residual Stress Modeling with Phase Transformation for Wire Arc Additive Manufacturing of B91 Steel

Wire arc additive manufacturing (WAAM) is an energy-efficient manufacturing technique used for near-net-shape production of functional industrial components. However, heat accumulation during deposition and the associated mechanical and metallurgical changes result in complex residual stress profiles across the cross section of the fabricated components. These residual stresses are detrimental to the service life of the components. In this study, sequentially coupled thermomechanical analysis of WAAM B91 steel is conducted to quantify the residual stress variation across the component. The thermomechanical analysis includes a transient heat transfer model and a static stress model that incorporates the transformation-induced plasticity due to martensitic phase transformation. Here, the experimentally calibrated heat transfer model mirrors the temperature variation of the system during the deposition. The results from the stress model are validated via x-ray diffraction measurements, and the numerical results are in good agreement with the experimental data.

20 FOSSIL-FUELED POWER PLANTS↗

The MUSE beamline calorimeter

The MUon Scattering Experiment (MUSE) was motivated by the proton radius puzzle arising from the discrepancy between muonic hydrogen spectroscopy and electron–proton measurements. The MUSE physics goals also include testing lepton universality, precisely measuring two-photon exchange contribution, and testing radiative corrections. MUSE addresses these physics goals through simultaneous measurement of high precision cross sections for electron–proton and muon–proton scattering using a mixed-species beam. The experiment will run at both positive and negative beam polarities. Measuring precise cross sections requires understanding both the incident beam energy and the radiative corrections. For this purpose, a lead-glass calorimeter was installed at the end of the beam line in the MUSE detector system. Here, in this article, we discuss the detector specifications, calibration and performance. We demonstrate that the detector performance is well reproduced by simulation, and meets experimental requirements.

Calorimeter↗

Sparge Sampling of Molten Salts for Online Monitoring via Laser-Induced Breakdown Spectroscopy

A method was developed to sample molten salts by sparging to generate and transport aerosols to an isolated instrument for compositional analysis by laser-induced breakdown spectroscopy (LIBS). Real-time monitoring of molten salt composition is critical to developing molten salt nuclear reactors, which offer enhanced safety and efficiency. In this article, the sparge sampling method is described and compared with sampling using a Collison nebulizer. The size distribution and transport of aerosols produced from molten eutectic NaNO 3 –KNO 3 salt were compared for multiple gas flow rates (75–1200 mL min –1 ) and transport distances (0.68–2.61 m). Both methods produced aerosols ranging from 0.5 to 5.0 μm determined using a cascade impactor. Aerosols were effectively transported without pre- or trace-heating of gas lines, but transport efficiency was reduced by the formation of agglomerates. Sparge sampling was found to use less sample and less gas than a Collison nebulizer while producing a more concentrated aerosol stream (up to 5 μg L –1 ). The effects of laser energy and delay time on the signal quality of LIBS measurements of these aerosols were also studied. High energy and short delay times were found to enhance signal and repeatability, whereas signal-to-background and signal-to-noise ratios were highest at low energy and longer delay times. The capabilities of this system for online monitoring of molten salts were demonstrated with calibrations for Sr and Li with relative standard deviations of 2.6% and 1.5% and limits of detection of 380 and 180 μg g –1 , respectively.

Aerosols↗

Representing Global Soil Erosion and Sediment Flux in Earth System Models

Abstract Soil erosion produces enormous amounts of sediment, carbon, and nutrient fluxes from land to rivers, thus playing crucial roles in global biogeochemical cycles and food security. To predict soil erosion in the context of climate and land use changes, we explicitly parameterize cropland management actions (i.e., irrigation, conserved agriculture, and crop residue management) and geological factors (i.e., lithology and glacier) in the Energy Exascale Earth System Model (E3SM) soil erosion module. The erosion model is calibrated using a global‐scale regionalized parameter calibration method. The spatial variabilities of the modeled and the Revised Universal Soil Loss Equation (RUSLE) based benchmark soil erosion are consistent across vegetation, climate and soil properties. Compared with independent data, our model shows a bias reduction in 59% of the observations relative to the RUSLE‐based soil erosion, with 53% of the bias reduction exceeding 50%. This improvement is mainly due to a better representation of the topographic effect on soil erosion. Our results indicate that conserved agriculture practices have effectively reduced soil erosion in cropland by over 25% in the United States and Argentina. In contrast, irrigation has increased soil erosion in many Asian countries. For upland sediment flux, our model is consistent with the WBMsed benchmark data in inter‐basin variability but could be more skillful in simulating intra‐basin variability because it couples soil erosion and sediment flux explicitly. The developed model provides useful skills for more realistic predictions of soil erosion and river sediment dynamics under environmental changes.

58 GEOSCIENCES↗

Implementation of an impurity diagnostic suite on the Pegasus-III experiment

A suite of diagnostics used to assess impurity content and dynamics has been updated, upgraded, and installed on the Pegasus-III Experiment. Typical plasma parameters during local helicity injection start-up are τ shot ~10 ms, n e ~ 1 × 10 19 m –3 , and T e ~ 50 eV. The deployed diagnostics are compatible with this modest temperature and density regime and provide species identification, source localization, and estimation of radiation losses. Impurity species are determined by recording time-evolving, single line-of-sight spectra at 1.25 kfps using a SPRED (Survey, Poor Resolution, Extended Domain) vacuum ultraviolet spectrometer. SPRED is equipped with 450 g/mm grating, giving a spectral resolution of 0.33 nm and a spectral range from ~10 to 110 nm, useful to identify light impurity species in this temperature and density range. An absolutely calibrated spectrometer that collects light from the plasma at R tan = 15.9 cm and Δt ≥ 2 ms is used as a visible survey spectrometer and for continuum measurements. The radiated power from the plasma is estimated with a photodiode-based diagnostic. Two 16-channel absolute extreme ultraviolet diode arrays are placed behind pinhole apertures, resulting in 32 lines of sight at Z = 0, with a spatial resolution of 2–3 cm and a time response of 60 kHz. A photometrically calibrated collinear D α /near infrared filtered photodiode-based system measures the D α emission and around 1040 nm. All these instruments have been designed to suppress electromagnetic interference from megawatt-class switching power supplies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

In-line measurements of below-the-surface food deformation during drying with an interference-based optical fiber strain sensor

Real-time measurements of food deformation are important for quality control in drying, yet they pose significant challenges. In this study, we developed an interference-based optical fiber strain sensor to enable in-line, continuous, below-the-surface strain measurements in drying of soft food samples. Compared to a strain resolution of 8 × 10 -4 at zero strain and 7.2 × 10 -3 at 0.20 strain reported in our previously published work, the present study achieves markedly improved resolutions of 1.3 × 10 -4 at zero strain and 7.8 × 10 -4 at 0.25 strain, which strains are the lower and higher boundaries of the dynamic range, respectively. This nearly order-of-magnitude improvement is attributed to the unique interference-based sensing mechanism, no need for calibration to convert optical signals to strain, and the system-design-enabled immunity to fiber-disk misalignments and light source intensity fluctuations. To demonstrate the in-line process monitoring, deformation measurements of fresh banana slices and sugar cookie doughs were carried out in a benchtop oven and an industrial-scale hot-air pilot dryer, respectively. In both dryers, strain measurements were continuously measured during the whole drying process at various depths and radii below the sample surfaces, with the strains up to 25%. Computer vision was used only in the benchtop drying to confirm the faithfulness of the fiber sensor measurements and cannot provide below-the-surface measurements. The measured spatiotemporal deformation allowed us to confirm the shell-hardening effect and to determine the speed and location of large deformation changes in the whole drying process, the latter of which is related to the sample cracking. To the best of the authors’ knowledge, this study is the first to report on an interferometry-based fiber sensor to measure food deformation. This sensor and the sensing mechanism have high potential for real-time process monitoring and control to prevent over-drying or cracking during drying processes.

47 OTHER INSTRUMENTATION↗