Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “consistency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Consistency of nucleon-transfer sum rules in well-deformed nuclei

Here, nucleon-transfer sum rules have been assessed via a consistent reanalysis of cross-section data from neutron-adding (d, p) and -removing (d, t) reactions on well-deformed isotopes of Gd, Dy, Er, Yb, and W, with 92 ≤ N ≤ 108 , studied at the Niels Bohr Institute in the 1960s and 1970s. These are complemented by new measurements of cross sections using the (d, p), (d, t), and (p, d) reactions on a subset of these nuclei. The sum rules, defined in a Nilsson-model framework, are remarkably consistent. A single overall normalization is used in the analysis, which appears to be sensitive to assumptions about the reaction mechanism, and in the case of sums using the (d, t) reaction, differs from values determined from reactions on spherical systems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Consistency test of neutrinoless double beta decay with one isotope

We discuss a consistency test which makes it possible to discriminate unknown nuclear background lines from neutrinoless double beta decay with only one isotope. By considering both the transition to the ground state and to the first excited 0{sup +} state, a sufficiently large detector can reveal if neutrinoless double beta decay or some other nuclear physics process is at work. Such a detector could therefore simultaneously provide a consistency test for a certain range of Majorana masses and be sensitive to lower values of the effective Majorana mass <m{sub {nu}}{sub e}>.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Self-consistent, high-order spatial profiles in a model for two-fluid turbulent mixing

A Reynolds-averaged Navier-Stokes model is presented with the property that it admits self-consistent, high-order spatial profiles in simulations of two-fluid turbulent mixing layers. Whereas previous models have been limited by the assumption of a linear mixing profile, the present paper relaxes this assumption and, as a result, is shown to achieve much better agreement with experimental profiles. Similarity analysis is presented to derive constraints on model coefficients to enforce desired self-similar growth rates that are fully consistent with the high-order spatial profiles. Through this similarity analysis, it is shown that care must be taken in model construction, as it is possible to construct certain terms in such a way as to leave growth rates unconstrained. This model, termed the k-Φ-L-a-V model, is then applied in simulations of Rayleigh-Taylor, Richtmyer-Meshkov, and Kelvin-Helmholtz mixing layers. Overall, these simulations confirm that the expected growth parameters are recovered and high-order spatial profiles are maintained.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Physical foundation and consistent formulation of atomic-level fluxes in transport processes

Irving and Kirkwood derived the transport equations from the principles of classical statistical mechanics using the Dirac delta to define local densities. Thereby, formulas for fluxes were obtained in terms of molecular variables. The Irving and Kirkwood formalism has inspired numerous formulations. Many of the later developments, however, considered it more rigorous to replace the Dirac delta with a continuous volume-weighted averaging function and subsequently defined fluxes as a volume density. Although these volume-averaged flux formulas have dominated the literature for decades and are widely implemented in popular molecular dynamics (MD) software, they are a departure from the well-established physical concept of fluxes. We review the historical developments that led to the unified physical concept of fluxes for transport phenomena. We then use MD simulations to show that these popular flux formulas conserve neither momentum nor energy, nor do they produce fluxes that are consistent with their physical definitions. We also use two different approaches to derive fluxes for general many-body potentials. The results of the formulation show that atomistic formulas for fluxes can be fully consistent with the physical definitions of fluxes and conservation laws.

74 ATOMIC AND MOLECULAR PHYSICS↗

Self-Consistent Simulation of the Excitation of Compressional Alfvén Eigenmodes and Runaway Electron Diffusion in Tokamak Disruptions

Alfvénic modes in the current quench (CQ) stage of the tokamak disruption have been observed in experiments. In DIII-D the excitation of these modes is associated with the presence of high-energy runaway electrons (REs), and a strong mode excitation is often associated with the failure of RE plateau formation. In this work we present results of self-consistent kinetic-MHD simulations of RE-driven compressional Alfvén eigenmodes (CAEs) in DIII-D disruption scenarios, providing an explanation of the CQ modes. Simulation results reveal that high energy trapped REs can have resonance with the Alfvén mode through their toroidal precession motion, and the resonance frequency is proportional to the energy of REs. The mode frequencies and their relationship with the RE energy are consistent with experimental observations. Further, the perturbed magnetic fields from the modes can lead to spatial diffusion of REs including the nonresonant passing ones, thus providing the theoretical basis for a potential approach for RE mitigation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Zonal magnetic fields regulate nonlinear edge-localized-mode dynamics via self-consistent force balance

Edge-localized modes (ELMs) eject intense bursts of heat and particles that threaten plasma-facing components in fusion reactors. Nonlinear full-torus BOUT++ simulations show that turbulence-driven zonal magnetic fields (ZMFs) play an essential role in nonlinear ELM evolution by maintaining self-consistent force balance. Zonal flows mitigate the initial crash through shear but do not prevent continued radial transport. When ZMFs are self-consistently included, turbulence-driven zonal currents modify the parallel current distribution and magnetic tension and are associated with a reduction of the axisymmetric (𝑛 = 0) perturbed radial force imbalance. This coincides with a transition from convective, bursty propagation to more localized, diffusive transport. Similar behavior is observed across the regimes considered, including both resistive-ballooning and peeling-ballooning cases. Finally, associated signatures, including radial electric field shear and parallel current redistribution, provide experimentally accessible diagnostics for present devices and ITER-relevant conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multi-Label Classification with Constraint-Based Learning for Hierarchical Consistency

We explore the limitations of traditional crossentropy loss in a hierarchical multi-label classification setting and introduce a novel loss function. This function is designed to integrate hierarchical constraints directly into the training process. By incorporating such constraints into the loss, our approach slightly improves the logical consistency of predictions in structured domains. We demonstrate the efficacy of our approach through experiments on primary site and histology classification by using electronic pathology reports. These results show that our proposed hierarchical loss function enhances the model's ability to produce predictions that are logically consistent with the natural data hierarchies, and it slightly improves predictive accuracy. Our framework may be extended to other hierarchical domains, however the performance gains are context specific.

Shivanna, Abhishek [ORNL] (ORCID:0009000665228593)↗

UVCGAN: UNet Vision Transformer cycle-consistent GAN for unpaired image-to-image translation

Unpaired image-to-image translation has broad applications in art, design, and scientific simulations. One early breakthrough was CycleGAN that emphasizes one-to-one mappings between two unpaired image domains via generative-adversarial networks (GAN) coupled with the cycle-consistency constraint, while more recent works promote one-to-many mapping to boost diversity of the translated images. Motivated by scientific simulation and one-to-one needs, this work revisits the classic CycleGAN framework and boosts its performance to outperform more contemporary models without relaxing the cycle-consistency constraint. To achieve this, we equip the generator with a Vision Transformer (ViT) and employ necessary training and regularization techniques. Compared to previous best-performing models, our model performs better and retains a strong correlation between the original and translated image. An accompanying ablation study shows that both the gradient penalty and self-supervised pre-training are crucial to the improvement. To promote reproducibility and open science, the source code, hyperparameter configurations, and pre-trained model are available at https: //github.com/LS4GAN/uvcgan.

97 MATHEMATICS AND COMPUTING↗

A Systematic Comparison for Consistent Scenario Development Using Microscopic Simulation Software

This study aims to explore a methodology that enables the development of consistent traffic micro simulation for emerging traffic and vehicle control technologies for improved mobility and energy efficiency across different modeling platforms. Researchers might study the same application on different platforms and have the need to benchmark across platforms. However, there lacks a systematic study on simulation software comparison, especially for emerging mobility and energy efficiency applications. For this, a systematic scenario development and evaluation approach is presented and demonstrated to compare scenarios generated in different traffic microsimulation platforms. Network-level and vehicle-level trip performance results of the traffic scenario are evaluated in three microscopic simulation platforms - VISSIM, AIMSUN, and SUMO. The results indicate that the network-level performance is consistent among the three software suites except when the demand is high, where the energy consumption performance varies.

Saroj, Abhilasha [ORNL] (ORCID:0000000191178063)↗

A consistent approach for the development of a comprehensive data base of time-dependent parameters for concrete engineered barriers

This paper presents a consistent approach for the development of a comprehensive data base of time-dependent hydraulic and transport parameters for concrete engineered barriers of the future Dessel near surface repository for low level waste. The parameter derivation is based on integration of selected data obtained through an extensive literature review, data from experimental studies on cementitious materials specific for the Dessel repository and numerical modelling using physically-based models of water and mass transport. Best estimate parameter values for assessment calculations are derived, together with source and expert range and their probability density function wherever the data was sufficient. We further discuss a numerical method for up-scaling laboratory derived parameter values to the repository scale; the resulting large-scale effective parameters are commensurate with numerical grids used in models for radionuclide migration. To accommodate different levels of conservatism in the various assessment calculations defined by ONDRAF/NIRAS, several sets of parameter values have been derived based on assumptions that introduce different degrees of conservatism. For pertinent parameters, the time evolution of such properties due to the long-term concrete degradation is also addressed. The implementation of the consistent approach is demonstrated by considering the pore water diffusion coefficient as an example. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Consistency and reproducibility in atomic layer deposition

Atomic layer deposition (ALD) is a thin film synthesis technique that can provide exquisite accuracy and precision in film thickness and composition even on complex, large area substrates. Based on self-limiting surface chemistry, ALD can be insensitive to process conditions and reactor designs, allowing an ALD process developed in one lab to be easily reproduced in other labs. In practice, however, ALD is sometimes difficult to reproduce or replicate, and the results can vary substantially between ALD reactors and between labs. This is exemplified by large deviations in reports on the growth of, e.g., Al2O3, FeOx, and TiO2 given the same precursors under similar conditions. Furthermore, the problem of irreproducibility seems to be growing as ALD is adopted by more researchers and integrated into new applications. In this article, the authors highlight some of the major sources of variations and errors and common misconceptions related to ALD. In particular, the authors focus on issues related to precursors, substrates, and deposition tools. The authors illustrate these problems through examples from the literature, and they present results from numerical simulations that describe how nonidealities would manifest in thickness profiles in a typical cross-flow reactor. They also describe how reproducibility in ALD is linked to consistent experimental practice and reporting between labs. The authors’ hope is that by educating newcomers to ALD and advocating for consistent reporting of deposition conditions, they can minimize irreproducibility and enable ALD practitioners to realize the full potential afforded by self-limiting surface chemistry.

36 MATERIALS SCIENCE↗

SU-E-E-05: Improving Contouring Precision and Consistency for Physicians-In-Training with Simple Lab Experiments

Purpose: Target contouring for high-dose treatments such as radiosurgery of brain metastases is highly critical in eliminating marginal failure and reducing complications as shown by recent clinical studies. In order to improve contouring accuracy and practice consistency for the procedure, we introduced a self-assessed physics lab practice for the physicians-in-training. Methods: A set of commercially acquired high-precision PMMA plastic spheres were randomly embedded in a Styrofoam block and then scanned with the CT/MR via the clinical procedural imaging protocol. A group of first-year physicians-in-training (n=6) from either neurosurgery or radiation oncology department were asked to contour the scanned objects (diameter ranged from 0.4 cm to 3.8 cm). These user-defined contours were then compared with the ideal contour sets of object shape for self assessments to determine the maximum areas of the observed discrepancies and method of improvements. Results: The largest discrepancies from initial practice were consistently found to be located near the extreme longitudinal portions of the target for all the residents. Discrepancy was especially prominent when contouring small objects < 1.0 cm in diameters. For example, the mean volumes rendered from the initial contour data set differed from the ideal data set by 7.7%±6.6% for the participants (p> 0.23 suggesting agreement cannot be established). However, when incorporating a secondary imaging scan such as reconstructed coronal or sagittal images in a repeat practice, the agreement was dramatically improved yielding p<0.02 in agreement with the reference data set for all the participants. Conclusion: A simple physics lab revealed a common pitfall in contouring small metastatic brain tumors for radiosurgical procedures and provided a systematic tool for physicians-in-training in improving their clinical contouring skills. Dr Ma is current a board member of international stereotactic radiosurgical society.

60 APPLIED LIFE SCIENCES↗

SU-E-T-590: Optimizing Magnetic Field Strengths with Matlab for An Ion-Optic System in Particle Therapy Consisting of Two Quadrupole Magnets for Subsequent Simulations with the Monte-Carlo Code FLUKA

Purpose: Aim of this study was to optimize the magnetic field strengths of two quadrupole magnets in a particle therapy facility in order to obtain a beam quality suitable for spot beam scanning. Methods: The particle transport through an ion-optic system of a particle therapy facility consisting of the beam tube, two quadrupole magnets and a beam monitor system was calculated with the help of Matlab by using matrices that solve the equation of motion of a charged particle in a magnetic field and field-free region, respectively. The magnetic field strengths were optimized in order to obtain a circular and thin beam spot at the iso-center of the therapy facility. These optimized field strengths were subsequently transferred to the Monte-Carlo code FLUKA and the transport of 80 MeV/u C12-ions through this ion-optic system was calculated by using a user-routine to implement magnetic fields. The fluence along the beam-axis and at the iso-center was evaluated. Results: The magnetic field strengths could be optimized by using Matlab and transferred to the Monte-Carlo code FLUKA. The implementation via a user-routine was successful. Analyzing the fluence-pattern along the beam-axis the characteristic focusing and de-focusing effects of the quadrupole magnets could be reproduced. Furthermore the beam spot at the iso-center was circular and significantly thinner compared to an unfocused beam. Conclusion: In this study a Matlab tool was developed to optimize magnetic field strengths for an ion-optic system consisting of two quadrupole magnets as part of a particle therapy facility. These magnetic field strengths could subsequently be transferred to and implemented in the Monte-Carlo code FLUKA to simulate the particle transport through this optimized ion-optic system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-J-19: Robust Region-Of-Interest (ROI) for Consistent Registration On Deteriorated Surface Images

Purpose: For African-American patients receiving breast radiotherapy with a bolus, skin darkening can affect the surface visualization when using optical imaging for daily positioning and gating at deep-inspiration breath holds (DIBH). Our goal is to identify a region-of-interest (ROI) that is robust against deteriorating surface image quality due to skin darkening. Methods: We study four patients whose post-mastectomy surfaces are imaged daily with AlignRT (VisionRT, UK) for DIBH radiotherapy and whose surface image quality is degraded toward the end of treatment. To simulate the effects of skin darkening, surfaces from the first ten fractions of each patient are systematically degraded by 25–35%, 40–50% and 65–75% of the total area of the clinically used ROI-ipsilateral-chestwall. The degraded surfaces are registered to the reference surface in six degrees-of-freedom. To identify a robust ROI, three additional reference ROIs — ROI-chest+abdomen, ROI-bilateral-chest and ROI-extended-ipsilateral-chestwall are created and registered to the degraded surfaces. Differences in registration using these ROIs are compared to that using ROI-ipsilateral-chestwall. Results: For three patients, the deviations in the registrations to ROI-ipsilateral-chestwall are > 2.0, 3.1 and 7.9mm on average for 25–35%, 40–50% and 65–75% degraded surfaces, respectively. Rotational deviations reach 11.1° in pitch. For the last patient, registration is consistent to within 2.6mm even on the 65–75% degraded surfaces, possibly because the surface topography has more distinct features. For ROI-bilateral-chest and ROI-extended-ipsilateral-chest registrations deviate in a similar pattern. However, registration on ROI-chest+abdomen is robust to deteriorating image qualities to within 4.2mm for all four patients. Conclusion: Registration deviations using ROI-ipsilateral-chestwall can reach 9.8mm on the 40–50% degraded surfaces. Caution is required when using AlignRT for patients experiencing skin darkening since the accuracy of AlignRT registration deteriorates. To avoid this inaccuracy, we recommend use of ROI-chest+abdomen, on which registration is consistent within 4.2mm even for highly degraded surfaces.

60 APPLIED LIFE SCIENCES↗

TU-FG-201-03: Automatic Pre-Delivery Verification Using Statistical Analysis of Consistencies in Treatment Plan Parameters by the Treatment Site and Modality

Purpose: A novel computer software system, namely APDV (Automatic Pre-Delivery Verification), has been developed for verifying patient treatment plan parameters right prior to treatment deliveries in order to automatically detect and prevent catastrophic errors. Methods: APDV is designed to continuously monitor new DICOM plan files on the TMS computer at the treatment console. When new plans to be delivered are detected, APDV checks the consistencies of plan parameters and high-level plan statistics using underlying rules and statistical properties based on given treatment site, technique and modality. These rules were quantitatively derived by retrospectively analyzing all the EBRT treatment plans of the past 8 years at authors’ institution. Therapists and physicists will be notified with a warning message displayed on the TMS computer if any critical errors are detected, and check results, confirmation, together with dismissal actions will be saved into database for further review. Results: APDV was implemented as a stand-alone program using C# to ensure required real time performance. Mean values and standard deviations were quantitatively derived for various plan parameters including MLC usage, MU/cGy radio, beam SSD, beam weighting, and the beam gantry angles (only for lateral targets) per treatment site, technique and modality. 2D-based rules of combined MU/cGy ratio and averaged SSD values were also derived using joint probabilities of confidence error ellipses. The statistics of these major treatment plan parameters quantitatively evaluate the consistency of any treatment plans which facilitates automatic APDV checking procedures. Conclusion: APDV could be useful in detecting and preventing catastrophic errors immediately before treatment deliveries. Future plan including automatic patient identify and patient setup checks after patient daily images are acquired by the machine and become available on the TMS computer. This project is supported by the Agency for Healthcare Research and Quality (AHRQ) under award 1R01HS0222888. The senior author received research grants from ViewRay Inc. and Varian Medical System.

60 APPLIED LIFE SCIENCES↗

Comparative analysis of SARS-CoV-2 neutralization titers reveals consistency between human and animal model serum and across assays

The evolution of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) requires ongoing monitoring to judge the ability of newly arising variants to escape the immune response. A surveillance system necessitates an understanding of differences in neutralization titers measured in different assays and using human and animal serum samples. We compared 18 datasets generated using human, hamster, and mouse serum and six different neutralization assays. Datasets using animal model serum samples showed higher titer magnitudes than datasets using human serum samples in this comparison. Fold change in neutralization of variants compared to ancestral SARS-CoV-2, immunodominance patterns, and antigenic maps were similar among serum samples and assays. Most assays yielded consistent results, except for differences in fold change in cytopathic effect assays. Hamster serum samples were a consistent surrogate for human first-infection serum samples. These results inform the transition of surveillance of SARS-CoV-2 antigenic variation from dependence on human first-infection serum samples to the utilization of serum samples from animal models.

Cell Biology↗

Self-consistent calculations of alpha-decay energies

On the basis of the self-consistent theory of finite Fermi systems, the energies of alphadecay chains were calculated for several new superheavy nuclei discovered recently in experiments of the Dubna-Livermore Collaboration headed by Yu.Ts. Oganessian. The approach in question is implemented on the basis of the generalized method of the density functional proposed by Fayans and his coauthors. The version used here relies on the functional DF3-a proposed recently for describing a wide array of nuclear data, including data on superheavy nuclei. A detailed comparison of the results obtained on this basis with the predictions of different approaches, including the self-consistent Skyrme-Hartree-Fock method, the micro-macro method in the version developed by Sobiczewski and his coauthors, and the phenomenological method of Liran and his coauthors, is performed. The resulting alpha-decay energies are used to calculate respective lifetimes with the aid of the phenomenological Parkhomenko-Sobiczewski formula.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Self-consistent approach to beta decay and delayed neutron emission

A brief overview of the recent self-consistent studies of nuclear beta decay is given including the relativistic quasi-particle random-phase approximation or QRPA and Finite Amplitude Method. The results of our self-consistent continuum QRPA model based on the density functional description of the ground states are presented. They are in a good agreement with the recent experimental beta-decay half-lives and delayed neutron emission branchings for the nuclei approaching (and beyond) the neutron closed shells N = 50 near {sup 78}Ni and N = 82 near {sup 132}Sn. A comparison with the recent calculations from relativistic QRPA model, Finite Amplitude Method and semi-microscopic finite-range droplet model is performed. An importance of the quasi-particle phonon coupling is stressed for the description of the beta decay and delayed multi-neutron emission rates. A strategy of extending our approach to the deformed nuclei and the open problems are discussed.

74 ATOMIC AND MOLECULAR PHYSICS↗