Puncture discharges in surface dielectrics as contaminant sources in spacecraft environments

Spacecraft in geosynchronous orbits are known to become charged to large negative potentials during the local midnight region of the satellite orbit. Such discharges have been studied by the electron beam irradiation of dielectric samples in a vacuum environment. In addition to static measurements and photographic examination of the puncture discharges in Teflon samples, the transient characteristics of the electrical discharges are determined from oscillographs of voltage and current and by charged particle measurements employing a biased Faraday cup and a retarding potential analyzer. Using these latter techniques, studies of angular and energy distributions of charged particles have indicated an initial burst of high energy electrons (5 x 10 to the 13th power per discharge at energies greater than 300 eV) followed by a less intense burst of lower energy negative particles. Positive ions are emitted from the discharge site in an initial high velocity burst followed by a lower velocity burst tentatively identified as carbon.

Yadlowsky, E. J.↗

J series thruster isolator failure analysis

Three Hg propellant isolators (two cathode and one main) failed during testing in the Mission Profile Life Test. These failures involved contamination of the surface of the alumina insulating body which resulted in heating of the vaporizer by leakage current from the high voltage supply, with subsequent loss of propellant flow rate control. Failure analysis of the isolators showed the surface resistance was temperature dependent and that the alumina could be restored to its original insulating state by grit blasting the surface. The contaminant was identified as carbon and the most likely sources identified as ambient facility hydrocarbons, directed back-sputtered facility materials, and outgassing from organic insulating materials within the thruster envelope. Methods to eliminate contamination from each of these sources are described.

Campbell, J. W.↗

Copolyimide Surface Modifying Agents for Particle Adhesion Mitigation

Marine biofouling, insect adhesion on aircraft surfaces, microbial contamination of sterile environments, and particle contamination all present unique challenges for which researchers have adopted an array of mitigation strategies. Particulate contamination is of interest to NASA regarding exploration of the Moon, Mars, asteroids, etc.1 Lunar dust compromised seals, clogged filters, abraded visors and space suit surfaces, and was a significant health concern during the Apollo missions.2 Consequently, NASA has instituted a multi-faceted approach to address dust including use of sacrificial surfaces, active mitigation requiring the use of an external energy source, and passive mitigation utilizing materials with an intrinsic resistance to surface contamination. One passive mitigation strategy is modification of a material s surface energy either chemically or topographically. The focus of this paper is the synthesis and evaluation of novel copolyimide materials with surface modifying agents (SMA, oxetanes) enabling controlled variation of surface chemical composition.

Wohl, Christopher J.↗

Surface Processes Control the Fate of Reactive Oxidants Generated by Electrochemical Activation of Hydrogen Peroxide on Stainless-Steel Electrodes

Low-cost stainless-steel electrodes can activate hydrogen peroxide (H 2 O 2 ) by converting it into a hydroxyl radical ( • OH) and other reactive oxidants. At an applied potential of +0.020 V, the stainless-steel electrode produced • OH with a yield that was over an order of magnitude higher than that reported for other systems that employ iron oxides as catalysts under circumneutral pH conditions. Decreasing the applied potential at pH 8 and 9 enhanced the rate of H 2 O 2 loss by shifting the process to a reaction mechanism that resulted in the formation of an Fe(IV) species. Significant metal leaching was only observed under acidic pH conditions (i.e., at pH <6), with the release of dissolved Fe and Cr occurring as the thickness of the passivation layer decreased. Despite the relatively high yield of • OH production under circumneutral pH conditions, most of the oxidants were scavenged by the electrode surface when contaminant concentrations comparable to those expected in drinking water sources were tested. The stainless-steel electrode efficiently removed trace organic contaminants from an authentic surface water sample without contaminating the water with Fe and Cr. With further development, stainless-steel electrodes could provide a cost-effective alternative to other H 2 O 2 activation processes, such as those by ultraviolet light.

42 ENGINEERING↗

A noncontacting scanning photoelectron emission technique for bonding surface cleanliness inspection

Molecular contamination of bonding surfaces can drastically affect the bond strength that can be achieved and therefore the structural integrity and reliability of the bonded part. The presence of thin contaminant films on bonding surfaces can result from inadequate or incomplete cleaning methods, from oxide growth during the time between cleaning (such as grit blasting) and bonding, or from failure to properly protect cleaned surfaces from oils, greases, fingerprints, release agents, or deposition of facility airborne molecules generated by adjacent manufacturing or processing operations. Required cleanliness levels for desired bond performance can be determined by testing to correlate bond strength with contaminant type and quantity, thereby establishing the degree of contamination that can be tolerated based on the strength that is needed. Once the maximum acceptable contaminant level is defined, a method is needed to quantitatively measure the contaminant level on the bonding surface prior to bonding to verify that the surface meets the established cleanliness requirement. A photoelectron emission technique for the nondestructive inspection of various bonding surfaces, both metallic and nonmetallic, to provide quantitative data on residual contaminant levels is described. The technique can be used to scan surfaces at speeds of at least 30 ft/min using a servo system to maintain required sensor to surface spacing. The fundamental operation of the photoelectron emission sensor system is explained and the automated scanning system and computer data acquisition hardware and software are described.

Gause, Raymond L.↗

Evaluation of two transport aircraft and several ground test vehicle friction measurements obtained for various runway surface types and conditions. A summary of test results from joint FAA/NASA Runway Friction Program

Tests with specially instrumented NASA Boeing 737 and 727 aircraft together with several different ground friction measuring devices were conducted for a variety of runway surface types and conditions. These tests are part of joint FAA/NASA Aircraft/Ground Vehicle Runway Friction Program aimed at obtaining a better understanding of aircraft ground handling performance under adverse weather conditions and defining relationships between aircraft and ground vehicle tire friction measurements. Aircraft braking performance on dry, wet, snow and ice-covered runway conditions is discussed as well as ground vehicle friction data obtained under similar runway conditions. For a given contaminated runway surface condition, the correlation between ground vehicles and aircraft friction data is identified. The influence of major test parameters on friction measurements such as speed, test tire characteristics, type and amount of surface contaminant, and ambient temperature are discussed. The effect of surface type on wet friction levels is also evaluated from comparative data collected on grooved and ungrooved concrete and asphalt surfaces.

Yager, Thomas J.↗

Microbial Characterization of Heat Melt Compaction for Treatment of Space Generated Solid Wastes

One treatment process in development for solid waste management in space has been the Trash Compaction Processing System (TCPS). Human space mission wastes typically contain large percentages of contaminated wet solid waste. The Heat Melt Compactor (HMC) is being developed to be a multi-function means of water recovery, volume reduction, and the making safe of contaminant-rich trash with the potential for waste stabilization and/or sterilization. To determine the efficacy of the HMC treatment to kill microorganisms in solid waste and remain biologically stable, testing was conducted on three tiles produced by HMC-Gen 2 at Ames Research Center. Samples were shipped to Kennedy Space Center to test for microbial viability after compaction, determine the bio-stability of the HMC disks during storage (43 days), and assess potential airborne contaminate microbial growth on surfaces at low and high humidity conditions. In addition to the products of solid waste processing technologies, there is a concern that the crew might come into contact with hardware surfaces that have been contaminated by microorganisms during waste processing. The extent of microbial surface contamination of waste processing hardware was determined by surface sample swabbing and analysis for total bacterial and yeast counts and cultivable counts of aerobic and anaerobic bacteria, spore-forming bacteria, and fungi. Results indicate that trash processing increased bacterial counts on the surfaces of the compacter. All but one biological indicator spore strip imbedded in the HMC produced tiles were negative for growth after incubation for five days indicating effective sterilization through the heat melt compaction process. Analysis of core samples as well as surface growth of tiles inoculated with Aspergillus niger fungal spores incubated at three levels of humidity indicate that HMC created tiles did not support the proliferation of bacterial and fungal growth.

Mary E Hummerick↗

Collection and review of metals data obtained from LDEF experiment specimens and support hardware

LDEF greatly extended the range of data available for metals exposed to the low-Earth-orbital environment. The effects of low-Earth-orbital exposure on metals include meteoroid and debris impacts, solar ultraviolet radiation, thermal cycling, cosmic rays, solar particles, and surface oxidation and contamination. This paper is limited to changes in surface composition and texture caused by oxidation and contamination. Surface property changes afford a means to study the environments (oxidation and contamination) as well as in-space stability of metal surfaces. We compare thermal-optical properties for bare aluminum and anodized aluminum clamps flown on LDEF. We also show that the silicon observed on the LDEF tray clamps and tray clamp bolt heads is not necessarily evidence of silicon contamination of LDEF from the shuttle. The paper concludes with a listing of LDEF reports that have been published thus far that contain significant findings concerning metals.

Bourassa, Roger↗

Temporal Characterization of Tritium Smear Activities

Tritium collection efficiency varies as a function of smear media. The use of porous smear materials leads to an increase in the measured tritium activity as a function of time when the measurement is performed with liquid scintillation counters. Operational inclusion of the efficiency differences and the time dependence of the tritium smear activity is necessary to preclude inadvertently releasing materials or areas. Thomas Jefferson National Laboratory Radiological Control Department identified a contaminated stainless steel containment vessel that previously housed a target containing more than 37 TBq of tritium. The item was systematically sectioned and surveyed to compare three smear types: water-wetted cotton swabs, water-wetted paper smears, and ethanol-wetted Styrofoam wipes (NUC-Wipes™). The total activity of each section was determined using repeated decontamination. The time dependence of the measured activity was also studied. The measured activity of both paper smears and cotton swabs showed significant time dependence. The cotton swabs also showed significantly reduced collection efficiency. Given the widespread use of both of these media in routine contamination surveys, site operational limits were derived using fitted curves for time dependence and average efficiency results. In conclusion, the use of these more restrictive limits allows for rapid measurement of tritium smears while ensuring regulatory compliance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

General contamination criteria for optical surfaces

Physical models are developed for establishing criteria to decide on the acceptable contamination level of optical devices in space-borne conditions. Optical systems can be degraded in terms of decreased throughput, i.e., transmissivity or reflectivity, or increases in the total integrated scatter (TIS). Performance losses can be caused by particulate accretion, molecular film accretion, and impact cratering. A quantitative relationship is defined for film thickness and loss of throughput. Formulas are also developed for cases where induced surface defects are larger than the desired viewing wavelengths, or smaller or of the same order of the observed wavelengths. The techniques are used to quantify the degradation of a VUV solar coronagraph, a VUV stellar telescope, and a solar cell due to TIS. Applications are projected for estimating the contamination sensitivity of specific instruments, assessing the contamination hazard from known particulates, or to define clean room standards.

Bremer, J. C.↗

Contamination threats to critical surfaces from handling and storage practices.

Review of the procedures and results of a program designed to remove the threat of sources of molecular and particulate contamination of critical optical, electrical, and mechanical elements in spacecraft. The results of recent contamination-probing thermal-vacuum tests indicate that some of the materials and practices commonly used to protect critical surfaces from molecular or particulate contamination can themselves represent significant threats. These contamination sources include clean-room and clean-tent materials, gloves, tissues, and covering or packaging materials. Mass and infrared spectral analyses of these materials and the environments and instruments exposed to them show that the contaminants are mostly plasticizers, slip or antistatic agents, and binders used in the manufacture of these products. Products of particular threat include vinyl gloves, boots, clean-tent walls, and some polyethylene sheets and bags. Techniques for reducing these threats are discussed.

Poehlmann, H. C.↗

Interactions of surfaces with the solar plasma

The induced environment is the main source of contamination on a spacecraft. The contamination of surfaces by volatile condensable material (VCM) present on spacecraft is being studied by many investigators both in the laboratory and space. In addition to VCM, the space environment is also a contributing factor in the contamination of surfaces. The effects of the interaction of the solar plasma with surfaces is examined. Plasma particles impact at energies in the multi-kilovolt range and penetrate and become trapped in surfaces. Results show that protons can penetrate up to 600 monolayers into surfaces and reach saturation concentrations of 6%.

Mckeown, D.↗

Removal of hydrocarbon contaminant film from spacecraft optical surfaces using a radiofrequency-excited oxygen plasma.

Results of a study on the feasibility of removing contaminant films from optical surfaces in vacuum, using an oxygen plasma, are discussed. Contaminant films were deposited onto optical surfaces from butadiene and methane gases at a pressure of about 4 torr in the presence of ultraviolet radiation. Optical surfaces evaluated included ultraviolet-reflecting mirrors, gratings, quartz disks, and spacecraft thermal control surfaces. In general, it was found that contaminants could be removed successfully from surfaces using an oxygen plasma. Exceptions were the white-paint thermal control surfaces, which, when contaminated, degraded further during exposure to the oxygen plasma.

Beverly, W. D.↗

Evaluation of Hydrogen Gettering Rates Correlated to Surface Composition and Texture of Nickel-Plated Zircaloy Getters of Different Heat Treatment Procedures

Coatings of metal specimens are known to have an impact on hydrogen gettering (hydrogen absorption). The coating can have one or more functions, such as enhancing gettering, preventing gettering and/or preventing oxidation of the metal substrate. It is known that contaminants and surface texture can impact hydrogen gettering/absorption performance, but has not previously been thoroughly explored. This study evaluated the role of different post-plating heat treatments of nickel-plated zircaloy-4 getters (NPGs) and the role of the heat treatments on gettering rates, surface composition and texture. Nickel plating is applied to prevent oxidation of the Zircaloy-4 surface and also enhances gettering. The nickel plating must be heat treated before desirable gettering can occur. Our NPG getters with historically known satisfying performance were pre-heat treated in air followed by activation heat treatment in a vacuum at a higher temperature. In this study, we were interested in finding out if both heat treatment steps were necessary to obtain a desirable gettering performance, or if one step could be omitted. XPS analysis showed that if the nickel surface is not heat treated before bonding the nickel to the zirconium in the activation step, there will be carbon contaminants on the surface, which significantly reduces gettering. We studied the texture of Zircaloy-4 using SEM/EBSD to compare NPGs with both heat treatment steps with NPGs that had no post-plating heat treatment to learn if the degree of cold work could be impacted by the heat treatment steps. We did not observe any differences in texture between them. We measured gettering rates of both pretreated and activated NPGs and NPGs that had been activated without first being pre-heat treated. We found that the NPGs without the first post-plating heating step had up to a seven times slower gettering rate and obtained higher plateau pressures due to the contaminated surface. Thus, the pre-heat treatment in air before activation is necessary to avoid slower gettering rates and higher plateau pressures.

36 MATERIALS SCIENCE↗

Cleanliness evaluation of rough surfaces with diffuse IR reflectance

Contamination on bonding surfaces has been determined to be a primary cause for degraded bond strength in certain solid rocket motor bondlines. Hydrocarbon and silicone based organic contaminants that are airborne or directly introduced to a surface are a significant source of contamination. Diffuse infrared (IR) reflectance has historically been used as an effective technique for detection of organic contaminants, however, common laboratory methods involving the use of a Fourier transform IR spectrometer (FTIR) are impractical for inspecting the large bonding surface areas found on solid rocket motors. Optical methods involving the use of acousto-optic tunable filters and fixed bandpass optical filters are recommended for increased data acquisition speed. Testing and signal analysis methods are presented which provide for simultaneous measurement of contamination concentration and roughness level on rough metal surfaces contaminated with hydrocarbons.

Pearson, L. H.↗