Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Optical Imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Gas, Stars, and Star Formation in Alfalfa Dwarf Galaxies

We examine the global properties of the stellar and Hi components of 229 low H i mass dwarf galaxies extracted from the ALFALFA survey, including a complete sample of 176 galaxies with H i masses <10(sup 7.7) solar mass and Hi line widths <80 kilometers per second. Sloan Digital Sky Survey (SDSS) data are combined with photometric properties derived from Galaxy Evolution Explorer to derive stellar masses (M*) and star formation rates (SFRs) by fitting their UV-optical spectral energy distributions (SEDs). In optical images, many of the ALFALFA dwarfs are faint and of low surface brightness; only 56% of those within the SDSS footprint have a counterpart in the SDSS spectroscopic survey. A large fraction of the dwarfs have high specific star formation rates (SSFRs), and estimates of their SFRs and M* obtained by SED fitting are systematically smaller than ones derived via standard formulae assuming a constant SFR. The increased dispersion of the SSFR distribution at M* approximately less than10(exp 8)M(sub 0) is driven by a set of dwarf galaxies that have low gas fractions and SSFRs; some of these are dE/dSphs in the Virgo Cluster. The imposition of an upper Hi mass limit yields the selection of a sample with lower gas fractions for their M* than found for the overall ALFALFA population. Many of the ALFALFA dwarfs, particularly the Virgo members, have H i depletion timescales shorter than a Hubble time. An examination of the dwarf galaxies within the full ALFALFA population in the context of global star formation (SF) laws is consistent with the general assumptions that gas-rich galaxies have lower SF efficiencies than do optically selected populations and that Hi disks are more extended than stellar ones.

ALFALFA↗

Designing the Imaging and Breadboard System for FBCE-TL Project

This presentation outlines the support work done on designing the imaging and breadboard system of the Transfer Line (TL) project, which is the third module for the Flow Boiling and Condensation Experiment (FBCE) operating in the Fluids Integrated Rack on-board the International Space Station (ISS). The goal of the FBCE is to serve as a facility for flow boiling and condensation investigating two-phase flow and heat transfer data in microgravity. The TL module aims use existing FBCE hardware to study cryogenic chilldown, a large component of cryogenic propellant tank transfer research. The TL test module will perform chilldown studies with normal-perfluorohexane (nPFH), a cryogenic simulant, flowing through a super-heated line, which is heated through the process of Joule-heating. SolidWorks and Creo were used to create electrically conductive pipe junctions that connect and seal several Indium Tin Oxide (ITO) coated sapphire tube sections together to allow for low leak probability fluid flow and circumferentially uniform electrical current density. It is necessary to understand and calculate the thermal expansion of the tubing sections such that the junctions would not leak at anticipated operating temperatures and pressures, would maintain electrical contact, and not crack the crystalline tubes. Optical imaging techniques were used to build an experimentally validated image remapping process for flight-like setups of cylindrical tubes. Then MATLAB was used to create an algorithm that distorts an image based on the refraction of light passing through the mediums we were imaging through to accurately visualize the cryogenic chilldown that is of scientific interest. This research will assist NASA to move forward with long-duration spaceflight missions where knowledge of efficient heat transfer processes becomes more critical.

imaging system↗

Nonpolytropic model for the Coma Cluster

In this article we demonstrate, for the first time, how a physically motivated static model for both the gas and galaxies in the Coma Cluster of galaxies can jointly fit all available X-ray and optical imaging and spectroscopic data. The principal assumption of this nonpolytropic model (Cavaliere & Fusco-Femiano 1981, hereafter CFF), is that the intracluster gas temperature is proportional to the square of the galaxy velocity dispersion everywhere throughout the cluster; no other assumption about the gas temperature distribution is required. After demonstrating that the CFF nonpolytropic model is an adequate representation of the gas and galaxy distributions, the radial velocity dispersion profile, and the gas temperature distribution, we derive the following information about the Coma Cluster: 1. The central temperature is about 9 keV and the central density is 2.8 x 10(exp -3)/cm(exp 3) for the X-ray emitting plasma; 2. The binding mass of the cluster is approximately 2 x 10(exp 15) solar mass within 5 Mpc for (H(sub 0) = 50 km/sec/Mpc), with a mass-to-light ratio of approximately 160 solar mass/solar luminosity; 3. The contribution of the gas to the total virial mass increases with distance from the cluster center, and we estimate that this ratio is no greater than approximately 50% within 5 Mpc. The ability of the CFF nonpolytropic model to describe the current X-ray and optical data for the Coma Cluster suggests that a significant fraction of the thermal energy contained in the hot gas in this as well as other rich galaxy clusters may have come from the interaction between the galaxies and the ambient cluster medium. interaction between the galaxies and the ambient cluster medium.

Fusco-Femiano, R.↗

Stability and Heat Transfer Characteristics of Condensing Films

The overall objective of this research is to investigate the fundamental physics of film condensation in reduced gravity. The condensation of vapor on a cool surface is important in many engineering problems,including spacecraft thermal control and also the behavior of condensate films that may form on the interior surfaces of spacecraft. To examine the effects of body force on condensing films, two different geometries have been tested in the laboratory: (1) a stabilizing gravitational body force (+1g, or condensing surface facing 'upwards') and (2) de-stabilizing gravitational body force (-1g, or 'downwards'). For each geometry, different fluid configurations are employed to help isolate the fluid mechanical and thermal mechanisms operative in condensing films. The fluid configurations are (a) a condensing film, and (b) a non-condensing film with film growth by mass addition by through the plate surface. Condensation experiments are conducted in a test cell containing a cooled copper or brass plate with an exposed diameter of 12.7 cm. The metal surface is polished to allow for double-pass shadowgraph imaging, and the test surface is instrumented with imbedded heat transfer gauges and thermocouples. Representative shadowgraph images of a condensing, unstable (-1g) n-pentane film are shown. The interfacial disturbances associated with the de-stabilizing body force leading to droplet formation and break-off can be clearly seen. The heat transfer coefficient associated with the condensing film is shown. The heat transfer coefficient is seen to initially decrease, consistent with the increased thermal resistance due to layer growth. For sufficiently long time, a steady value of heat transfer is observed, accompanied by continuous droplet formation and break-off. The non-condensing cell consists of a stack of thin stainless steel disks 10 cm in diameter mounted in a brass enclosure. The disks are perforated with a regular pattern of 361 holes each 0.25 mm in diameter. Non-condensing experiments in -1g have employed 50 cSt and 125 cSt silicone oil pumped through the perforated disks at a specified rate by a syringe micropump. The time to droplet break-off and the disturbance wavelengths appear to decrease with increasing pumping rate. The ability to reliably perform multi-point, ultrasonic measurements of the film thickness has been demonstrated. A linear array of eight transducers of 6 mm diameter (with a beam footprint of comparable size) are pulsed with a square-wave signal at a frequency of 5 MHz and a pulse duration of approximately 0.3 s. For thin films (60 m to 2-3 mm in thickness) the layer thickness is determined by frequency analysis, where the received ultrasound pulse is Fourier transformed and the spacing between the peaks in the frequency spectrum is analyzed. For thicker layers (up to at least 1 cm in thickness), time-domain analysis is performed of the received ultrasound pulses to generate directly the layer thickness. A time-trace of the film thickness at a point using a single transducer in the linear array is shown for the case of an unstable (-1g) n-pentane film. The oscillations in film thickness are evidently due to the passage and/or shedding of droplets from the cooled plate surface. The entire transducer array was used to measure the changes in film thickness resulting from the passage of gravity waves generated either by an oscillating wall or the impact of a single droplet on the free surface of a film. The enclosure in both cases was 14 cm square and the transducer spacing was 12 mm. Best results were obtained using as test fluid a mixture of 50% glycerol and 50% water with a fluid layer thickness of 3-5 mm. In both cases the measured wavelengths and wave propagation speeds using the ultrasound technique compared reasonably well with those observed by optical imaging. Additional information can be found in the original extended abstract.

Hermanson, J. C.↗

Modified camera records lens settings on film

Camera is modified by inserting optical imaging system between lens and film. This system requires no electrical power, is low in weight, and adds nothing to external size of the camera.

Thompson, R. E.↗

The liquid crystal light valve, an optical-to-optical interface device

A photoactivated liquid crystal light valve is described as an optical-to-optical interface device (OTTO) which is designed to transfer an optical image from a noncoherent light beam to a spatially coherent beam of light, in real time. Schematics of OTTO in use, the liquid cyrstal cell, and the liquid crystal structure are presented. Sensitivity characteristics and the principles of operation are discussed.

Jacobson, A. D.↗

Two dimensional digital computer

The development of a two dimensional data processing system is reported that extracts data from optical images by performing multiple logical operations simultaneously. A two dimensional logical circuits is described that contains a liquid crystal negation element and an OR-ing element. The negation element performs 20,000 negations simultaneously, and the OR does 20,000 OR operations simultaneously.

Schaefer, D. H.↗

Application of signal detection theory to optics

Basic quantum detection and estimation theory, applications to optics, photon counting, and filtering theory are studied. Recent work on the restoration of degraded optical images received at photoelectrically emissive surfaces is also reported, the data used by the method are the numbers of electrons ejected from various parts of the surface.

Helstrom, C. W.↗

Observation of X-ray emission from M31

Observation of X-ray emission from M31 in the 0.5- to 5.0-keV band, using rocket-borne proportional counters. The integrated flux corresponds to (2.2 plus or minus 0.6) x 10 to the 39th ergs/sec at M31, and is confined chiefly to a region coinciding with the optical image of the galaxy. The spectrum has a slope similar to the bright Galactic X-ray sources. The intensity, spectral, and spatial data suggest that the bulk of X-ray emission from M31, and by inference from most normal galaxies, is due to a small group of highly luminous sources, in agreement with the Galactic X-ray luminosity function.

Bowyer, S.↗

Optical-to-optical interface device

An investigation was conducted to develop an optical-to-optical interface device capable of performing real-time incoherent-to-incoherent optical image conversion. The photoactivated liquid crystal light valve developed earlier represented a prototype liquid crystal light valve device capable of performing these functions. A device was developed which had high performance and extended lifetime.

Jacobson, A. D.↗

The Corralitos Observatory program for the detection of lunar transient phenomena

This is a final report on the establishment, observing procedures, and observational results of a survey program for the detection of lunar transient phenomena (LTP's) by electro-optical image conversion means. For survey, a unique detection system with an image orthicon was used as the primary element in conjunction with a 24-in. f/20 Cassegrainian telescope. Observations in three spectral ranges, with 6,466 man-hours of observing, were actually performed during the period from October 27, 1965, to April 26, 1972. Within this entire period, no color or feature change within the detection capabilities of the instrumentation was observed, either independently or in follow up of amateur LTP reports, with the exception of one general bluing and several localized bluings (probably ascribable to the effects of the terrestrial atmosphere) that were observed solely by the Corralitos system. A table is presented indicating amateur and professional reports of LTP's and the results of efforts to confirm these reports through the Corralitos system.

Hynek, J. A.↗

The role of fiber optics in mass spectrometer electro-optical ion detection

This paper describes the development of an electro-optical ion detector combining the best features of photographic and electrical ion detection (i.e., wide mass range coverage and low ion detection threshold respectively). A nineteen fold fiber optic image dissector is discussed which reformats the 1 mm x 361 mm mass spectrometer focal plane format to a 19 mm x 19 mm format suitable for vidicon imaging and electronic display of the data.

Norris, D. D.↗

A perspective of synthetic aperture radar for remote sensing

The characteristics and capabilities of synthetic aperture radar are discussed so as to identify those features particularly unique to SAR. The SAR and Optical images were compared. The SAR is an example of radar that provides more information about a target than simply its location. It is the spatial resolution and imaging capability of SAR that has made its application of interest, especially from spaceborne platforms. However, for maximum utility to remote sensing, it was proposed that other information be extracted from SAR data, such as the cross section with frequency and polarization.

Skolnik, M. I.↗

Independent appraisal of the MSFC optical data reduction schemes

A few state-of-the-art optical image processing techniques are described and their potential applications to the ACPL experiments are suggested. The discussion also includes the selection of recording media in the present system and the enhancement of signal-to-noise ratio for the expected data from ACPL.

Liu, H. K.↗

The brightness distribution of IRC +10216 at 11 microns

The brightness distribution of IRC +10216 at a wavelength of 11 microns was measured in detail using a spatial interferometer. This brightness distribution appears to have azimuthal symmetry; an upper limit of 1.1 may be set to the ellipticity at 11 microns if the object has a major axis oriented either along or perpendicular to the major axis of the optical image. The radial distribution shows both compact and extended emission. The extended component, which is due to thermal emission from circumstellar dust, contributes 91% of the total flux and has a 1/e diameter of 0.90 minutes. The tapered shape of this component is consistent with a l/r squared dust density dependence. The compact component is unresolved (less than 0.2 minutes in diameter) and represents emission from the central star seen through the circumstellar envelope.

Sutton, E. C.↗

The brightness distribution of IRC +10216 at 11 microns

The brightness distribution of IRC +10216 at a wavelength of 11 microns has been measured in detail by using spatial interferometer. This brightness distribution appears to have azimuthal symmetry; an upper limit of 1.1 may be set to the ellipticity at 11 microns if the object has a major axis oriented either along or perpendicular to the major axis of the optical image. The radial distribution shows both compact and extended emission. The extended component, which is due to thermal emission from circumstellar dust, contributes 91% of the total flux and has a 1/e diameter of 0.90 arcsec. The tapered shape of this component is consistent with a dust density dependence on the inverse square of radial distance. The compact component is unresolved (less than 0.2 arcsec in diameter) and represents emission from the central star seen through the circumstellar envelope.

Sutton, E. C.↗