Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CAMERA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

The Sensor Dilemma in Intelligent Transportation Systems: Evaluating Radar, Lidar and Camera: Preprint

Intelligent transportation systems (ITS) are at the forefront in advancing the way we interact with and perceive the transportation network. This revolution is fueled by the significant advancement in sensor perception technologies such as radar, lidar, and video imaging, which are the most popular modalities for ITS. Real-time perception data from these sensors allow intelligent infrastructure-side decision-making to improve the energy, efficiency, and safety at traffic intersections. As traffic departments across the United States transition from traditional loop detectors and emulators and embrace newer technologies, they are often left with a dilemma in choosing a sensor technology for infrastructure-based perception that is reliable, inexpensive, and easy to set up and that has robust performance in varying weather conditions. However, choosing a sensor that checks all these boxes is not straightforward, as every sensor type has unique benefits and drawbacks. Radar is excellent at detecting long-range vehicles and weather resistance but lacks high resolution. Lidar is expensive and weather-sensitive, while cameras provide rich visual data at a low cost but are constrained by lighting and visibility. This study examines radar, lidar, and camera sensor capabilities to ascertain whether any of these qualifies as the "best" sensor for ITS perception. While no single sensor can meet all the demands of ITS, a hybrid approach combining multiple sensor modalities like radar, lidar, and cameras offers the most robust solution for enhancing the safety and efficiency of ITS. Through this evaluation, we hope to draw attention to the necessity of the National Renewable Energy Laboratory's infrastructure perception and control framework, which presents a multisensor track data fusion engine to assimilate multiple data streams in order to provide robust and reliable perception.

33 ADVANCED PROPULSION SYSTEMS↗

Visualization of Porphyrin-Based Photosensitizer Distribution from Fluorescence Images In Vivo Using an Optimized RGB Camera

A handheld RGB camera was developed to monitor the in vivo distribution of porphyrin-based photosensitizer (PS) hematoporphyrin monomethyl ether (HMME) in blood vessels during photodynamic therapy (PDT). The focal length, f-number, International Standardization Organization (ISO) sensitivity, and shutter speed of the camera were optimized for the solution sample with various HMME concentrations. After the parameter optimization, it was found that the red intensity value of the fluorescence image was linearly related to the fluorescence intensity under investigated conditions. The RGB camera was then used to monitor the in vivo distribution of HMME in blood vessels in a skin-fold window chamber model. The red intensity value of the recorded RGB fluorescence image was found to be linearly correlated to HMME concentrations in the range 0–24 μM. Significant differences in the red to green intensity ratios were observed between the blood vessels and the surrounding tissue.

60 APPLIED LIFE SCIENCES↗

Vision-based inspection of prefabricated components using camera poses: Addressing inherent limitations of image-based 3D reconstruction

Modular construction can lead to additional cost overruns and delays when a defect is found on the construction site and is not easily repairable. Researchers have developed various methods that use image-based 3D reconstruction for quality assessment, but they have inherent limitations, such as inconsistency and dealing with surfaces with reflectivity and limited visual features. Therefore, this paper presents a vision-based quality assessment method using cameras for prefabricated components by addressing these limitations. Specifically, this paper proposes a novel quality inspection method with sub-millimeter accuracy using cameras focused on leveraging camera poses (as opposed to 3D point clouds that are often not consistent in quality) from the image-based 3D reconstruction. The 3D point estimation by computing triangulation was used for achieving accurate measurement. The proposed method is validated using six different variances and two case studies – an aluminum pipe with a reflective surface and a fabricated concrete column. Furthermore, the results demonstrate the accuracy and effectiveness of the proposed method.

42 ENGINEERING↗

Novel imaging technique for thermal neutrons using a fast optical camera

A novel imaging technique for thermal neutrons using a fast optical camera is presented. Thermal neutrons are reacted with 6 Lithium to produce a pair of 2.73 MeV tritium and 2.05 MeV alpha particles, which in turn interact in a thin layer of LYSO crystal scintillator to produce a localized flash of light. These photons are directed by a pair of lenses to a micro-channel plate intensifier, and its output is connected to the optical camera, TPX3CAM. The results from the camera are reconstructed through a custom algorithm. Various cutting parameters were found through data analysis to eliminate the background, and they were shown effective in matching the simulated rate of the neutron source. The system is fast with 40 ns decay time and allows free-space light collection, both vastly enhances flexibility of neutron detection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solid-state framing camera operating in interferometric mode

A high speed solid-state framing camera has been created which can operate in interferometric mode. This camera measures the change in the index of refraction of a semiconductor when x-rays are incident upon it. This instrument uses an x-ray transmission grating/mask in front of the semiconductor to induce a corresponding phase grating in the semiconductor which can then be measured by an infrared probe beam. The probe beam scatters off of this grating, enabling a measure of the x-ray signal incident on the semiconductor. In this specific instrument, the zero-order reflected probe beam is attenuated and interfered with the diffracted orders to produce an interferometric image on a charge coupled device camera of the phase change induced inside the semiconductor by the incident x-rays.

74 ATOMIC AND MOLECULAR PHYSICS↗

Imaging suprathermal x-rays from a laboratory plasma jet using PIN-diode-based and scintillator-based 1D pinhole/coded aperture cameras

A PIN-diode-based 1D x-ray camera and a scintillator-based 1D x-ray camera, both with a microsecond to submicrosecond time resolution, have been developed to perform time-resolved imaging of transient, low-intensity, suprathermal x-rays associated with magnetohydrodynamic instabilities disrupting a plasma jet. These cameras have a high detection efficiency over a broad x-ray band, a wide field of view, and the capability to produce >50 time-resolved frames with a ≤1 μs time resolution. The x-ray images are formed by a pinhole or by a coded aperture placed outside a vacuum chamber in which the plasma jet is launched. The 1D imaging shows that the location of the x-ray source is either a few centimeters away from an inner disk electrode or near a spatially translatable metal frame that is 30–40 cm away from the electrode. Compared to a pinhole, a coded aperture increases the signal collection efficiency but also introduces unwanted artifacts.

Instruments & Instrumentation↗

Slicing Newton spheres with a two-camera 3D imaging system

We demonstrate a simple approach to achieve three-dimensional ion momentum imaging. The method employs two complementary metal–oxide–semiconductor cameras in addition to a standard microchannel plates/phosphor screen imaging detector. The two cameras are timed to measure the decay of luminescence excited by ion hits to extract the time of flight. The achieved time resolution is better than 10 ns, which is mainly limited by camera jitters. A better than 5 ns resolution can be achieved when the jitter is suppressed.

Chemistry↗

A compressed sensing X-ray camera with a multilayer architecture

Recent advances in compressed sensing theory and algorithms offer new possibilities for high-speed X-ray camera design. In many CMOS cameras, each pixel has an independent on-board circuit that includes an amplifier, noise rejection, signal shaper, an analog-to-digital converter (ADC), and optional in-pixel storage. When X-ray images are sparse, i.e., when one of the following cases is true: (a.) The number of pixels with true X-ray hits is much smaller than the total number of pixels; (b.) The X-ray information is redundant; or (c.) Some prior knowledge about the X-ray images exists, sparse sampling may be allowed. In this work, we first illustrate the feasibility of random on-board pixel sampling (ROPS) using an existing set of X-ray images, followed by a discussion about signal to noise as a function of pixel size. Next, we describe a possible circuit architecture to achieve random pixel access and in-pixel storage. The combination of a multilayer architecture, sparse on-chip sampling, and computational image techniques, is expected to facilitate the development and applications of high-speed X-ray camera technology.

47 OTHER INSTRUMENTATION↗

Demonstration of improvement in 2D tomographic reconstructions of filtered cameras in the JET ITER-like wall divertor due to corrected interpretation of reflections

Improved localization of emission and reduction of artefacts have been achieved in tomographic reconstructions of the tangentially viewing spectroscopic divertor cameras in JET by introducing the contribution of reflections from the metallic wall surfaces in the geometry definition of the tomography process. The reconstructions thus describe the plasma emission only without features arising from misinterpreted reflected light. Benchmarks with synthetic emission distributions showed accurate reproduction within 10% and 1–2% of the reference emission distributions and camera images, respectively, when the reflection correction was applied. Without the correction, the reconstructed emission was observed to concentrate from the divertor volume towards the wall surfaces together with bright emission artefacts appearing in front of the surfaces to reproduce the reflections seen in the camera images.

Karhunen, Juuso↗

Novel imaging technique for α-particles using a fast optical camera

A new imaging technique forα-particles using a fast optical camera focused on a thin scintillator is presented. Asα-particles interact in a thin layer of LYSO fast scintillator, they produce a localized flash of light. Furthermore, the light is collected with a lens to an intensified optical camera, Tpx3Cam, with single photon sensitivity and excellent spatial & temporal resolutions. The interactions of photons with the camera is reconstructed by means of a custom algorithm, capable of discriminating single photons using time and spatial information

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-stamping and counting of single photons using fast camera

I will discuss fast optical cameras based on the back-illuminated silicon sensor and Timepix3 ASIC. The sensor has high quantum efficiency, and the chip provides nanosecond scale time resolution and data-driven readout with 80Mpix/sec bandwidth. The intensified version of the camera is single photon sensitive and since recently has been used for registration of single photons in a variety of quantum information science and quantum imaging experiments as well as for other applications. We briefly review the camera and describe recent experiments with a Hong-Ou-Mandel interferometer to characterize its photon counting capabilities.

79 ASTRONOMY AND ASTROPHYSICS↗

Cooling the Dark Energy Camera CCD Array using a Closed-Loop, Two-Phase Liquid Nitrogen system

The Dark Energy Camera (DECam) is the new wide field prime-focus imager for the Blanco 4m telescope at CTIO. This instrument is a 3 sq. deg. camera with a 45 cm diameter focal plane consisting of 62 2k x 4k CCDs and 12 2k x 2k CCDs and was developed for the Dark Energy Survey that will start operations at CTIO in 2011. The DECam CCD array is inside the imager vessel. The focal plate is cooled using a closed loop liquid nitrogen system. As part of the development of the mechanical and cooling design, a full scale prototype imager vessel has been constructed and is now being used for Multi-CCD readout tests. The cryogenic cooling system and thermal controls are described along with cooling results from the prototype camera. The cooling system layout on the Blanco telescope in Chile is described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improving 3D reconstruction quality for root phenotyping: assessing the impact of camera calibration and imaging parameters

Arate 3D reconstruction is essential for high-throughput plant phenotyping, particularly for studying complex structures such as root systems. While photogrammetry and Structure from Motion (SfM) techniques have become widely used for 3D root imaging, the camera settings used are often underreported in studies, and the impact of camera calibration on model accuracyccu remains largely underexplored in plant science. In this study, we systematically evaluate the effects of focus, aperture, exposure time, and gain settings on the quality of 3D root models made with a multi-camera scanning system. We show through a series of experiments that calibration significantly improves model quality, with focus misalignment and shallow depth of field (DoF) being the most important factors affecting reconstruction accuracy. Our results further show that proper calibration has a greater effect on reducing noise than filtering it during post-processing, emphasizing the importance of optimizing image acquisition rather than relying solely on computational corrections. This work improves the repeatability and accuracy of 3D root imaging for phenotyping pipelines by giving useful calibration guidelines. This leads to better trait quantification for use in crop research and plant breeding in downstream analysis.

3D reconstruction↗

Correcting for digital image correlation speckle inversion at high temperature using color cameras

Digital image correlation (DIC) is a popular, noncontacting technique to measure full-field deformation by using cameras to track the motion of an applied surface pattern. Because it is noncontacting, DIC can be performed for extreme temperature applications (e.g., hot-fire rocket testing of carbon composite rocket nozzles) under harsh conditions during which bonded gauges are damaged. Speckle pattern inversion is a phenomenon that sometimes occurs while performing high-temperature DIC. During speckle pattern inversion, portions of the surface pattern that were initially darker at room temperature (e.g., graphite) may emit more light due to blackbody radiation than the portions that were initially paler, thereby producing images in which the pattern appears inverted at high temperature relative to the initial pattern at room temperature. This phenomenon can prevent the correlation algorithm from being able to resolve the displacements between images. This work compares three methods to mitigate speckle pattern inversion: (A) the subtraction method, a recently-published technique in which two high-temperature images are subtracted to remove unwanted light; (B) the filtering method, a popular technique in which optical bandpass filters screen out unwanted light; and (C) the histogram rescaling method, a proposed new method that pairs a color camera with a blue light source and uses information from the green sensor of the camera to correct against inversion in the blue sensor through postprocessing. The histogram rescaling method is shown to successfully eliminate speckle pattern inversion and has the added advantages that it does not require quasi-static loading to be able to compensate for speckle pattern inversion, nor does it impose thick-glass distortions caused by the optical filter.

Rowley, Lindsey J.↗

High-speed two-camera imaging pyrometer for mapping fireball temperatures

A high-speed imaging pyrometer was developed to investigate the behavior of flames and explosive events. The instrument consists of two monochrome high-speed Phantom v7.3 m cameras made by Vision Research Inc. arranged so that one lens assembly collects light for both cameras. The cameras are filtered at 700 or 900 nm with a 10 nm bandpass. The high irradiance produced by blackbody emission combined with variable shutter time and f-stop produces properly exposed images. The wavelengths were chosen with the expected temperatures in mind, and also to avoid any molecular or atomic gas phase emission. Here, the temperatures measured using this pyrometer of exploded TNT charges are presented.

42 ENGINEERING↗

Absolute calibration of optical streak cameras on picosecond time scales using supercontinuum generation

Here we report a new method using high stability, laser-driven supercontinuum generation in a liquid cell to calibrate the absolute photon response of fast optical streak cameras as a function of wavelength when operating at fastest sweep speeds. A stable, pulsed white light source based around the use of self-phase modulation in a salt solution was developed to provide the required brightness on picosecond timescales, enabling streak camera calibration in fully dynamic operation. The measured spectral brightness allowed for absolute photon response calibration over a broad spectral range (425-650nm). Calibrations performed with two Axis Photonique streak cameras using the Photonis P820PSU streak tube demonstrated responses which qualitatively follow the photocathode response. Peak sensitivities were 1 photon/count above background. The absolute dynamic sensitivity is less than the static by up to an order of magnitude. We attribute this to the dynamic response of the phosphor being lower.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Panama tropical forest digital camera imagery for vegetation phenology, Dec2016-May2019, PA-SLZ, PA-PNM, PA-BCI

Tropical forest phenology monitoring undertaken by use of Wingscapes timelapse cameras (phenocams) at three tropical evergreen forests in Panama: San Lorenzo, Parque Natural Metropolitano, and Barro Colorado Island. Following installation in December 2016, images were acquired every 10 minutes from 10 am to 2 pm daily, ending in May 2019. A total of 37 cameras were mounted on towers and tree branches, and view sunlit canopy or understory forest as follows: PA-SLZ, 11 canopy, 14 understory; PA-PNM, 6 canopy, 2 understory, PA-BCI, 4 canopy (trees also monitored for sap flow). This data package contains a full data description, metadata, species identification guides and summary files showing example fields of view from each camera location as csv and pdf files. The data description provides instructions for download of the full resolution image files, and other summary data products stored on external servers.

54 ENVIRONMENTAL SCIENCES↗

Camera Assembly Design Proposal for SRF Cavity Image Collection

This project seeks to collect images from the inside of a superconducting radio frequency (SRF) large grain niobium cavity during vertical testing. These images will provide information on multipacting and other phenomena occurring in the SRF cavity during these tests. Multipacting, a process that involves an electron buildup in the cavity and concurrent loss of RF power, is thought to be occurring near the cathode in the SRF structure (see Figure 1). Images of electron emission in the structure will help diagnose the source of multipacting in the cavity. Multipacting sources may be eliminated with an alteration of geometric or resonant conditions in the SRF structure. Other phenomena, including unexplained light emissions previously discovered at SLAC, may be present in the cavity. In order to effectively capture images of these events during testing, a camera assembly needs to be installed to the bottom of the RF structure. The SRF assembly operates under extreme environmental conditions: it is kept in a dewar in a bath of 2K liquid helium during these tests, is pumped down to ultra-high vacuum, and is subjected to RF voltages. Because of this, the camera needs to exist as a separate assembly attached to the bottom of the cavity. The design of the camera is constrained by a number of factors that are discussed below.

43 PARTICLE ACCELERATORS↗