Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Amplifiers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Lossless Quantum Hard-Drive Memory Using Parity-Time Symmetry

We theoretically studied the feasibility of building a long-term read-write quantum memory using the principle of parity-time (PT) symmetry, which has already been demonstrated for classical systems. The design consisted of a two-resonator system. Although both resonators would feature intrinsic loss, the goal was to apply a driving signal to one of the resonators such that it would become an amplifying subsystem, with a gain rate equal and opposite to the loss rate of the lossy resonator. Consequently, the loss and gain probabilities in the overall system would cancel out, yielding a closed quantum system. Upon performing detailed calculations on the impact of a driving signal on a lossy resonator, our results demonstrated that an amplifying resonator is physically unfeasible, thus forestalling the possibility of PT-symmetric quantum storage. Our finding serves to significantly narrow down future research into designing a viable quantum hard drive.

97 MATHEMATICS AND COMPUTING↗

ATONA Update [Slides]

The new ATONA amplifier, a Faraday Cup High Gain Resistor Amplifier, is described.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

New Advances in Optical Stochastic Cooling

Recently, Optical Stochastic Cooling (OSC) became the first demonstrated method for ultra-high-bandwidth stochastic cooling. The initial experiments at Fermilab’s IOTA ring explored the essential physics of the method and demonstrated cooling, heating and manipulation of beams and single particles. Having been validated in practice, with continued development, OSC carries the potential for dramatic advances in the state-of-the-art performance and flexibility for beam cooling and control. The ongoing program at Fermilab is now focused on the development of an OSC system that includes high-gain optical amplification, which promises a two-order-of-magnitude increase in the strength of the OSC force. In this talk, we briefly review the results of the initial experimental campaign, describe the status of the conceptual and hardware designs for the amplified OSC system, report initial experimental results of our high-gain amplifier development, and explore near-term operational plans and use cases.

43 PARTICLE ACCELERATORS↗

On forced RF generation of CW magnetrons for SRF accelerators

CW magnetrons, initially developed for industrial RF heaters, were suggested to power RF cavities of superconducting accelerators due to their higher efficiency and lower cost of RF power per Watt than used traditionally klystrons, IOTs or solid-state amplifiers. RF amplifiers driven by a master oscillator serve as coherent RF sources. CW magnetrons are regenerative RF generators with a huge regenerative gain to start up reliably with self-excitation even if the tube is powered by a DC power supply. This causes regenerative instability with a large noise when a magnetron operates with the anode voltage above the threshold of self-excitation. Traditionally for stabilization of magnetrons is used injection locking by a signal PLock ≤ -20 dB or less then of the magnetron power PMag. Then the magnetron generates the injection locked oscillations and generates noise. This may preclude use of standard CW magnetrons in some SRF accelerators. We developed briefly described below a mode for forced coherent RF generation of CW magnetrons when the magnetron startup is provided by the injected forcing signal and the regenerative noise is suppressed. The mode is most suitable for powering high Q-factor SRF cavities.

Kazakevich, G.↗

Comparison of the sensitivity of 236 U measurements in environmental samples by MC-ICP-MS and ATONA based high precision U TIMS measurements

The ATONA project is focused upon exploring the improvements in uranium isotope ratio measurements by thermal ionization mass spectrometry (TIMS) provided by a new, capacitor-based, amplifier technology. These “ATONA” Faraday amplifiers (Isotopx Ltd, UK) promise accurate, low-noise measurements of very small signals (< 1 femto-amp) in a traditional Faraday cup, which was only previously possible using an ion counter. This report outlines a series of experiments that were performed to assess the performance of the system in samples that test our rapid analysis procedures, and then compare the results against other mass spectrometry techniques currently available for environmental analyses. The following major goals were achieved: (1) illustrated the importance of 236 U measurements for the screening and analysis of environmental samples; (2) improved sensitivity for 236 U, and then identified 236 U in the 4350B standard at ultra-trace levels (3) Provided comparison of the 236 U sensitivity to multi-collector inductively coupled mass spectrometry techniques (4) Illustrated high TRL for the ATONA based measurement technique. This completes the reporting requirements for task 4 in the project LCP and highlights the utility of the system to make highly sensitive 236 U measurements in programmatically relevant sample matrices and at relevant uranium concentrations.

07 ISOTOPE AND RADIATION SOURCES↗

A new active base of photomultiplier R4125 designed for the PbWO4 calorimeter

This paper presents the design, performance, and results of the radiation tests of an active base for Hamamatsu R4125 photomultiplier tube. The active base was designed at Jefferson Lab and comprises of a high voltage divider and an on-board amplifier. The photomultiplier with the active base is used to detect light from lead tungstate scintillating crystals of the forward electromagnetic calorimeter of the GlueX detector. The active base amplifier allows to operate the tube at lower high voltage and thus to limit the photomultiplier anode current to a few micro ampereres at the maximum counter rate of 1 MHz counter, while retaining the dynamic range of output signals. The performance of calorimeter modules instrumented with the active base was studied using detector prototypes positioned into the beam of photons. The key performance parameters such as the linearity, high-rate capability, and the energy resolution verified that the active base design meets the detector specifications

Somov, Alexander [Thomas Jefferson National Accele↗

Development of an FGPA-Based Cavity Simulator for Testing RF Controls

LLRF is used to precisely control the amplitude and phase of the RF field in cavities. Often times, access to test the control algorithms with RF equipment, especially in the presence of beam, is limited or beyond reach. In such cases, testing must be done through computer modeling or simulations. Computer modeling is often too slow and difficult to interface with the LLRF hardware. Analog or digital cavity simulators are preferred as they allow for interaction with the LLRF controls platform in real-time, and compared to their analog counterparts, FPGA-based digital cavity simulators allow for a more adjustable and sophisticated implementation. The newly developed FPGA-based cavity simulator includes the cavity electrical model, the cavity mechanical model including Lorentz Force Detuning and microphonics, an amplifier model which can simulate real amplifier nonlinearities, and a beam model. The simulator has been validated using measurements from BNL’s CeC 704 MHz 5-cell SRF cryomodule.

43 PARTICLE ACCELERATORS↗

Short Circuit Detection and Voltage Sense for High Voltage Ionization Tube Power Supplies

Fermilab's PIP-II upgrade requires new rack-mounted power supplies for Beam Loss Monitor (BLM) ionization tubes compatible with the microTCA 4.1 standard, supporting high-side current measurement for short circuit detection, voltage sense telemetry, and low-side current measurement for beam loss readout. This work presents the design and preliminary schematic of such a supply. A resistive current sensing approach was chosen over inductive, optical, and Hall-effect alternatives for its independence from cable length and component availability. A 500 mΩ inline shunt steps the 2 kV common mode voltage down to roughly 70 V, producing a ~27 μV pulse during a short, which is amplified 500x, compared against a 14-bit DAC threshold, and latched to drive a fault line. Voltage sense steps the 2 kV output down at a 1V/1000V ratio, buffers it with a low bias current amplifier, and digitizes it via a 24-bit ADC over SPI. Onboard power is regulated from 12 V down to isolated 5 V and 3.3 V rails, with capacitive isolation on FPGA communication lines. Lumped parameter models were developed for the ionization tube (0.327 nF, 20 to 200 GΩ dynamic resistance) and the RG-58 coaxial cable to support the design. Component selection is complete and a preliminary schematic has been drawn in Altium Designer, forming the foundation for future prototyping and validation.

Yu, Kellen [Cornell U.]↗

The Readout Electronics of the Mu2e Electromagnetic Calorimeter

The Mu2e electromagnetic calorimeter has been designed to measure ~100 MeV electrons with energy resolution σE/E <10%, time resolution σt < 500ps and position resolution σx < 1cm. The detector is composed of 1348 un-doped CsI crystals coupled to two large area Silicon Photomultipliers (SiPMs). Each SiPM is connected to a Front End Electronics (FEE) chip which hosts the shaping amplifier and the high voltage linear regulator. A group of 20 FEE is controlled by one Mezzanine Board (MB) which transmits the amplified signals to one Digitizer ReAdout Controller board (DiRAC). The DiRAC samples the waveforms at 200 MHz with 12-bit ADCs, packs the data according to the Mu2e custom format and transmits them to the event builder through an optical transceiver. To limit the number of pass-through connectors and the length of the cables, the readout and digitization electronics is located inside the detector cryostat and close to the interaction target. The boards will have to sustain a neutron fluence of about 5x10 10 n/cm 2 @ 1 MeVeq (Si)/y and a Total Ionizing Dose of about 12 krad, while working into a 1T magnetic field and a vacuum of 10 (-4) Torr. This harsh operational environment has made the electronics design challenging and required an extended campaign of tests to select and qualify the employed electronic components. In this paper we report on the board architecture and design, on the qualification of the prototypes, as well as on the results of the first vertical slice test of the Mu2e calorimeter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Targeted Sequencing Assay for Serotyping Escherichia coli Using AgriSeq Technology

The gold standard method for serotyping Escherichia coli has relied on antisera-based typing of the O- and H-antigens, which is labor intensive and often unreliable. In the post-genomic era, sequence-based assays are potentially faster to provide results, could combine O-serogrouping and H-typing in a single test, and could simultaneously screen for the presence of other genetic markers of interest such as virulence factors. Whole genome sequencing is one approach; however, this method has limited multiplexing capabilities, and only a small fraction of the sequence is informative for subtyping or identifying virulence potential. A targeted, sequence-based assay and accompanying software for data analysis would be a great improvement over the currently available methods for serotyping. The purpose of this study was to develop a high-throughput, molecular method for serotyping E. coli by sequencing the genes that are required for production of O- and H-antigens, as well as to develop software for data analysis and serotype identification. To expand the utility of the assay, targets for the virulence factors, Shiga toxins ( stx 1 , and stx 2 ) and intimin ( eae ) were included. To validate the assay, genomic DNA was extracted from O-serogroup and H-type standard strains and from Shiga toxin-producing E. coli , the targeted regions were amplified, and then sequencing libraries were prepared from the amplified products followed by sequencing of the libraries on the Ion S5™ sequencer. The resulting sequence files were analyzed via the SeroType Caller™ software for identification of O-serogroup, H-type, and presence of stx 1 , stx 2 , and eae . We successfully identified 169 O-serogroups and 41 H-types. The assay also routinely detected the presence of stx 1a,c,d (3 of 3 strains), stx 2c−e,g (8 of 8 strains), stx 2f (1 strain), and eae (6 of 6 strains). Taken together, the high-throughput, sequence-based method presented here is a reliable alternative to antisera-based serotyping methods for E. coli .

Elder, Jacob R.↗

Multiplex detection and identification of viral, bacterial, and protozoan pathogens in human blood and plasma using an expanded high-density resequencing microarray platform

Introduction: Nucleic acid tests for blood donor screening have improved the safety of the blood supply; however, increasing numbers of emerging pathogen tests are burdensome. Multiplex testing platforms are a potential solution. Methods: The Blood Borne Pathogen Resequencing Microarray Expanded (BBP-RMAv.2) can perform multiplex detection and identification of 80 viruses, bacteria and parasites. This study evaluated pathogen detection in human blood or plasma. Samples spiked with selected pathogens, each with one of 6 viruses, 2 bacteria and 5 protozoans were tested on this platform. The nucleic acids were extracted, amplified using multiplexed sets of primers, and hybridized to a microarray. The reported sequences were aligned to a database to identify the pathogen. To directly compare the microarray to an emerging molecular approach, the amplified nucleic acids were also submitted to nanopore next generation sequencing (NGS). Results: The BBP-RMAv.2 detected viral pathogens at a concentration as low as 100 copies/ml and a range of concentrations from 1,000 to 100,000 copies/ml for all the spiked pathogens. Coded specimens were identified correctly demonstrating the effectiveness of the platform. The nanopore sequencing correctly identified most samples and the results of the two platforms were compared. Discussion: These results indicated that the BBP-RMAv.2 could be employed for multiplex detection with potential for use in blood safety or disease diagnosis. The NGS was nearly as effective at identifying pathogens in blood and performed better than BBP-RMAv.2 at identifying pathogen-negative samples.

59 BASIC BIOLOGICAL SCIENCES↗

Relations between Shot Noise, Gain Bandwidth, and Saturation of Instabilities

There are numerous instabilities present in charged particle beams that undergo exponential growth and reach saturation. In various applications, such as free-electron lasers or micro-bunching light sources, achieving saturation is desirable. Conversely, there are applications where these instabilities are utilized as linear broad-band amplifiers for signals embedded in the charged beam. In the latter scenario, the saturation of an instability induces non-linear distortions in the imprinted signal, thereby limiting the useful range of such amplifiers. Accurate evaluation of these instabilities necessitates a complete and comprehensive modeling approach that includes shot noise within the beam. Unfortunately, such modeling is not always feasible or practical. In this paper, we introduce a methodology utilizing the frequency and bandwidth of the instability as key parameters. Through this, we derive an estimation for the range of linear instability growth. Our derivation is conducted in a model-independent manner, making it applicable to a broad spectrum of instabilities. To validate our approach, we employ established and thoroughly benchmarked simulations with a free electron laser (FEL) code as well as self-consistent 3-dimensional simulation of plasma-cascade instability using code SPACE.

43 PARTICLE ACCELERATORS↗

Using Demanded Power and RDE Aggressiveness Metrics to Analyze the Impact of CACC Aggressiveness on Heavy Duty Platooning Power Consumption

Presently, a main mobility sector objective is to reduce its impact on the global greenhouse gas emissions. While there are many techniques being explored, a promising approach to improve fuel economy is to reduce the required energy by using slipstream effects. This study analyzes the demanded engine power and mechanical energy used by heavy-duty trucks during platooning and non-platooning operation to determine the aerodynamic benefits of the slipstream. A series of platooning tests utilizing class 8 semi-trucks platooning via Cooperative Adaptive Cruise Control (CACC) are performed. Comparing the demanded engine power and mechanical energy used reveals the benefits of platooning on the aerodynamic drag while disregarding any potential negative side effects on the engine. However, energy savings were lower than expected in some cases. It was hypothesized that the CACC may have amplified transient platooning events relative to the individual truck baseline results, hampering the potential energy savings. Therefore, the impact of the controller on the observed driving style was analyzed in detail. In order to quantify the transient operational characteristics of the experimental trials, metrics from the European Real Driving Emissions (RDE) legislation were modified to serve as metrics of aggressiveness during platooning. The metrics (v &middot; apos)95 and Relative Positive Acceleration (RPA) were calculated for platooning and non-platooning runs. These results indicate that the CACC induces small acceleration events during platooning to retain the commanded longitudinal separation between vehicles. These small acceleration events increase following vehicle aggressiveness during platooning and prevent the following vehicles from obtaining maximum energy savings. Moreover, a correlation between the RDE metric (v &middot; apos)95 and energy savings is developed. Hence, this work establishes the ability of RDE metrics to assess CACC impacts on platoon energy savings.

European Real Driving Emissions, RDE, greenhouse g↗

On operation and control of CW magnetrons for superconducting accelerators

CW magnetrons, developed for industrial RF heaters, were suggested to feed RF cavities of superconducting accelerators due to higher efficiency and lower cost of RF power than provide traditionally used klystrons, IOTs or solid-state amplifiers. RF amplifiers driven by a master oscillator serve as coherent RF sources. CW magnetrons are regenerative RF auto generators with a huge regenerative gain. This causes regenerative instability with a notable noise when a magnetron operates as an auto generator i.e., with the anode voltage above the threshold of self-excitation. Traditionally, an injection locking by a small signal is used for phase stabilization of magnetrons. In this case CW magnetrons with the injection-locked (coherent) oscillations generate a notable level of noise. This may preclude use of CW magnetrons in this mode in the Superconducting RF (SRF) accelerators. This paper reviews PIC modeling and previously obtained experimental results for the operation and control of CW magnetrons, which led to the development of techniques most suitable for various SRF accelerators using forced RF oscillation of magnetrons, when the magnetron is launched by an injected forcing signal, and regenerative noise is suppressed.

Kazakevich, G. [MUONS Inc., Batavia] (ORCID:000000↗

Response of marine post-frontal clouds to Gulf Stream variability

Understanding how Gulf Stream variation influences cloud morphology is critical for evaluating cloud feedback in the western North Atlantic Ocean and beyond, where mesoscale air-sea interactions dominate. This study investigates the impact of altered mean sea surface temperature (SST) and SST gradients on post-frontal cloud characteristics during cold-air outbreaks, using the Weather Research and Forecasting (WRF) model. Three sensitivity experiments are conducted: a control simulation (default SST), Plus4 (uniform SST increase of 4 K), and Gradplus (SST gradient enhanced by 25 %, centered around mean SST). Results reveal distinctly different responses in boundary layer dynamics and cloud macro-physics. In Plus4, a warmer and moister boundary layer reduces total cloud cover but promotes larger cloud sizes and elongated cloud streets, with diminished liquid water and enhanced ice-phase hydrometeors. Conversely, Gradplus amplifies impacts in the upwind colder SST regions, yielding a drier, colder boundary layer, weaker energy transport, and higher liquid water path but reduced ice water content and cloud lines. Tracer analysis highlights that SST modifications alter airmass sources near cloud tops due to the entrainment of ambient air, with Plus4 amplifying boundary layer contributions to cloud-top regions. These findings underscore the spatially varying effects of SST gradients and mean SST on cloud organization and microphysics, emphasizing the need to resolve ocean-atmosphere coupling in global models to improve the prediction of marine cloud feedback under warming scenarios.

AIR-SEA INTERACTION↗

Gain balanced nonlinear optical interferometer

A nonlinear fiber interferometer is disclosed suitable for fiber sensor and other applications. A first nonlinear fiber section amplifies probe and conjugate sidebands of a pump through four-wave mixing. A second section introduces a phase shift to be measured, for example from a sensor. A third nonlinear fiber section amplifies with phase-sensitive gain to increase signal-to-noise ratio. Based on phase-sensitive output power of probe and/or conjugate components, the phase shift can be measured. Superior performance can be obtained by balancing gain between the (first and third) nonlinear sections. Non-fiber, for example photonic integrated circuit, embodiments are disclosed. Differential sensing, alternative detection schemes, sensing applications, associated methods, and other variations are disclosed.

42 ENGINEERING↗

SENSEI: Characterization of Single-Electron Events Using a Skipper-CCD

We use a science-grade Skipper Charge Coupled Device (Skipper-CCD) operating in a low-radiation background environment to develop a semi-empirical model that characterizes the origin of single-electron events in CCDs. We identify, separate, and quantify three independent contributions to the single-electron events, which were previously bundled together and classified as ``dark counts'': dark current, amplifier light, and spurious charge. We measure a dark current, which depends on exposure, of (5.89+-0.77)x10^-4 e-/pix/day, and an unprecedentedly low spurious charge contribution of (1.52+-0.07)x10^-4 e-/pix, which is exposure-independent. In addition, we provide a technique to study events produced by light emitted from the amplifier, which allows the detector's operation to be optimized to minimize this effect to a level below the dark-current contribution. Our accurate characterization of the single-electron events allows one to greatly extend the sensitivity of experiments searching for dark matter or coherent neutrino scattering. Moreover, an accurate understanding of the origin of single-electron events is critical to further progress in ongoing R&D efforts of Skipper and conventional CCDs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spent enrichment media for growth of gene-matched microorganisms

A method for amplifying and detecting microorganisms, such as species of Listeria, is described. The method utilizes gene-matched enrichment media and PCR-based detection. The enrichment media is spent media produced using a modified microorganism containing a plurality of mutations in a selected gene such that the modified microorganism does not contain the PCR signature. Thus, PCR detects only the amplified microorganism of interest, not the modified microorganism. Exemplary methods and kits for amplification and detection of Listeria species are described.

Ozanich, Richard M.↗