Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ion tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Lifetime measurements of states of S 35 , S 36 , S 37 , and S 38 using the AGATA γ -ray tracking spectrometer

Lifetimes or lifetime limits of a small number of excited states of the sulfur isotopes with mass numbers A = 35 , 36, 37, and 38 have been measured using the differential recoil-distance method. The isotopes of sulfur were populated in binary grazing reactions initiated by a beam of 36 S ions of energy 225 MeV incident on a thin 208 Pb target which was mounted in the Cologne plunger apparatus. The combination of the PRISMA magnetic spectrometer and an early implementation of the AGATA γ-ray tracking array was used to detect γ rays in coincidence with projectile-like nuclear species. Lifetime measurements of populated states were measured within the range from about 1 to 100 ps. The number of states for which lifetime measurements or lifetime limits were possible was limited by statistics. For 35 S, the lifetime was determined for the first 1/2 + state at 1572 keV; the result is compared with a previous published lifetime value. The lifetime of the 3 - state of 36 S at 4193 keV was determined and compared with earlier measurements. No previous lifetime information exists for the (6 + ) state at 6690 keV; a lifetime measurement with large associated error was made in the present work. For 37 S, the states for which lifetime limits were established were those at 646 keV with J π = 3/2 - and at 2776 keV with J π = 11/2 - ; there are no previously published lifetime values for excited states of 37 S. Finally, a lifetime limit was established for the J π =(6 + ) state of 38 S at 3675 keV; no lifetime information exists for this state in the literature. Measured lifetime values were compared with the results of state-of-the-art shell-model calculations based on the PSDPF, SDPF-U, and FSU effective interactions. In addition, nuclear magnetic-dipole and electric-quadrupole moments, branching ratios, mixing ratios, and electromagnetic transition rates, where available, have been compared with shell-model values. The current work suffers from poor statistics; nevertheless, lifetime values and limits have been possible, allowing a useful discussion of the ability of state-of-the-art shell-model calculations to reproduce the experimental results.

electromagnetic transitions↗

Study of space charge in the ICARUS T600 detector

The accumulation of positive ions, produced by ionizing particles crossing Liquid Argon Time Projection Chambers (LAr-TPCs), may generate distortions of the electric drift field affecting the track reconstruction of the ionizing events. These effects could become relevant for large LAr-TPCs operating at surface or at shallow depth, where the detectors are exposed to a copious flux of cosmic rays. We report a detailed study of such possible field distortions in the ICARUS T600 LAr-TPC has been performed analyzing a sample of cosmic muon tracks recorded with one T600 module operated at surface in 2001. The maximum track distortion turns out to be of few mm in good agreement with the prediction by a numerical calculation. As a cross-check, the same analysis has been performed on a cosmic muon sample recorded during the ICARUS T600 run at the LNGS underground laboratory, where the cosmic ray flux was suppressed by a factor $\sim 10^6$ by 3400 m water equivalent shielding. No appreciable distortion has been observed, confirming that the effects measured on surface are actually due to ion space charge.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The effect of track structure on the induction of chromosomal aberrations in murine cells

PURPOSE: To measure chromosome aberrations in C3H 10T1/2 mouse fibroblasts using FISH painting at the first mitosis following exposure to 30 keV/microm hydrogen or neon ions. MATERIALS AND METHODS: Cells in plateau-phase were irradiated with 0.86 MeV protons at the TTT-3 Tandem accelerator in Naples (Italy), or with 400 MeV/n Ne ions at the HIMAC accelerator in Chiba (Japan). Colcemid-blocked cells were harvested at the first mitosis following exposure, and chromosome spreads were hybridized in situ with a fluorescein-labelled composite mouse DNA probe specific for chromosomes 2 and 8. RESULTS: Protons were more efficient than neon ions at the same LET in the induction of chromosome interchanges and breaks. Yields of complex exchanges were similar for both particles at the same dose, but protons produced mostly insertions, while with Ne exposure non-reciprocal exchanges were the most frequent complex-type exchange. CONCLUSIONS: Charged particles with the same LET produce different yields of chromosome aberrations, and some observed differences can be explained based on the available track-structure models.

NASA Center JSC↗

Thermodynamically Driven Synthetic Optimization for Cation-Disordered Rock Salt Cathodes

Relating the synthesis conditions of materials to their functional performance has long been an experience-based trial-and-error process. However, this methodology is not always efficient in identifying an appropriate protocol and can lead to overlooked opportunities for the performance optimization of materials through simple modifications of the synthesis process. In this work, we systematically track the structural evolution in the synthesis of a representative disordered rocksalt (a promising next-generation Li-ion cathode material) at the scale of both the long-range crystal structure and the short-range atomic structure using various in situ and ex situ techniques, including transmission electron microscopy, X-ray diffraction, and pair distribution function analysis. Further, an optimization strategy is proposed for the synthesis protocol, leading to a remarkably enhanced capacity (specific energy) of 313 mAh g –1 (987 Wh kg –1 ) at a low rate (20 mA g –1 ), with a capacity of more than 140 mAh g –1 retained even at a very high cycling rate of 2,000 mA g –1 . This strategy is further rationalized using ab initio calculations, and important opportunities for synthetic optimization demonstrated in this study are highlighted.

36 MATERIALS SCIENCE↗

Accuracy and precision of ESI-Orbitrap-IRMS observations of hours to tens of hours via reservoir injection

Here, orbitrap isotope ratio mass spectrometry (Orbitrap-IRMS) has recently been applied to high-precision, natural-abundance isotope ratio measurements of a diverse range of compounds, including amino acids, oxyanions, fatty acids, and metals. These measurements can characterize many isotope ratios simultaneously at high (≈1.0‰) precision. In a successful experiment, observed precision will track the shot-noise limit and be limited by experimental time. Some isotope ratios, for example those involving 17 O in organic compounds or multiply-substituted (‘clumped’) isotopologues, require experimental times of hours to tens of hours to achieve desired precision, while current sample introduction techniques focus on observations on the order of seconds to tens of minutes. In this study, we characterize Orbitrap-IRMS performance for three long duration measurements (individual acquisitions ≥1 h and as long as 24 h) using an automated reservoir injection system coupled to a Q Exactive HF Orbitrap with an electrospray ionization (ESI) source. First, we characterize long-term intra-measurement stability through a 24-h long measurement of acetone. We report the following isotope ratios and precisions (as acquisition errors, errors on the observed ratio within this measurement (σ AE )): 13 C/ 12 C (σ AE = 0.07‰), 17 O/ 16 O (σ AE = 1.1‰), 18 O/ 16 O (σ AE = 0.3‰), and 13 C 13 C/ 12 C (σ AE = 0.65‰). The σ AE of each tracks the shot noise limit throughout and is limited by the challenging conditions (high resolution and low numbers of ions per scan) required for 17 O/ 16 O measurement in the presence of 13 C via Orbitrap. Second, we characterize inter-measurement stability via a sequence of seven 75-min analyses of perchlorate. We observe the following ratios and acquisition errors: 37 Cl/ 35 Cl (σ AE = 0.09‰); 17 O/ 16 O (σ AE = 1.6‰); 18 O/ 16 O (σ AE = 0.7‰), 37 Cl 17 O/ 35 Cl 16 O (σ AE = 2.7‰), and 37 Cl 18 O/ 35 Cl 16 O (σ AE = 1.2‰). However, we find that inter-measurement drift between acquisitions limits our accuracy and precision for standardized measurements (i.e., error on reported δ values) to ≈1‰ for the 37 Cl/ 35 Cl measurement. Hence, the benefits of low σ AE may not be fully realized. Third, we demonstrate accuracy via sample/standard comparisons of a methionine sample with 13 C enrichment of ≈20‰ relative to a known standard. Using a sequence of seven 60-min analyses, we recover the following isotope ratios and standardized precisions (i.e., error on reported δ values, denoted propagated acquisition errors, σ PAE ): 33 S/ 32 S (σ PAE = 1.0‰), 34 S/ 32 S (σ PAE = 0.7‰), 15 N/ 14 N (σ PAE = 2.1‰), 2 H/ 1 H (σ PAE = 3.2‰), 13 C/ 12 C (σ PAE = 0.4‰), 18 O/ 16 O (σ PAE = 1.6‰), & 13 C 13 C/ 12 C (σ PAE = 2.8‰) with confirmation of accurate results for the known 13 C/ 12 C and 13 C 13 C/ 12 C enrichments. Together, our results demonstrate the viability of Orbitrap-IRMS for long duration measurements of diverse sample types via an automated reservoir injection system. Inter-measurement stability remains a challenge; we expect our methods to be most applicable to extended measurements of hard-to-observe properties, such as 17 O in organics and clumped isotopologues.

58 GEOSCIENCES↗

Study of Particle Loss in Synchrotron Phase Space Injection for ESR Using Weak-Strong Beam-Beam Simulation with Nonlinear Lattice

In this report, we use tracking simulations to investigate synchrotron phase space injection for electron accumulation in the electron storage ring of the Electron Ion Collider. Our simulation model accounts for both beam-beam interactions and lattice nonlinearities. Specifically, we examine how particle loss is influenced by various parameters. Additionally, we conduct a theoretical analysis and derive an analytical formula for the rapid evaluation of particle loss. Our results demon strate the feasibility of synchrotron phase-space injection for the electron storage ring and provide insights to guide parameter selection for the design of the injection line.

43 PARTICLE ACCELERATORS↗

The 25th Annual Precise Time and Time Interval (PTTI) Applications and Planning Meeting

Papers in the following categories are presented: recent developments in rubidium, cesium, and hydrogen-based frequency standards, and in cryogenic and trapped-ion technology; international and transnational applications of precise time and time interval (PTTI) technology with emphasis on satellite laser tracking networks, GLONASS timing, intercomparison of national time scales and international telecommunication; applications of PTTI technology to the telecommunications, power distribution, platform positioning, and geophysical survey industries; application of PTTI technology to evolving military communications and navigation systems; and dissemination of precise time and frequency by means of GPS, GLONASS, MILSTAR, LORAN, and synchronous communications satellites.

Sydnor, Richard L.↗

The 26th Annual Precise Time and Time Interval (PTTI) Applications and Planning Meeting

This document is a compilation of technical papers presented at the 26th Annual PTTI Applications and Planning Meeting. Papers are in the following categories: (1) Recent developments in rubidium, cesium, and hydrogen-based frequency standards, and in cryogenic and trapped-ion technology; (2) International and transnational applications of Precise Time and Time Interval technology with emphasis on satellite laser tracking, GLONASS timing, intercomparison of national time scales and international telecommunications; (3) Applications of Precise Time and Time Interval technology to the telecommunications, power distribution, platform positioning, and geophysical survey industries; (4) Applications of PTTI technology to evolving military communications and navigation systems; and (5) Dissemination of precise time and frequency by means of GPS, GLONASS, MILSTAR, LORAN, and synchronous communications satellites.

Sydnor, Richard↗

NASA Tech Briefs, April 2005

Gas-Tolerant Device Senses Electrical Conductivity of Liquid Nanoactuators Based on Electrostatic Forces on Dielectrics Replaceable Microfluidic Cartridges for a PCR Biosensor CdZnTe Image Detectors for Hard-X-Ray Telescopes High-Aperture-Efficiency Horn Antenna Full-Circle Resolver-to-Linear-Analog Converter Continuous, Full-Circle Arctangent Circuit Advanced Three-Dimensional Display System Automatic Focus Adjustment of a Microscope Topics covered include: FastScript3D - A Companion to Java 3D; Generating Mosaics of Astronomical Images; Simulating Descent and Landing of a Spacecraft; Simulating Vibrations in a Complex Loaded Structure; Rover Sequencing and Visualization Program; Software Template for Instruction in Mathematics; Support for User Interfaces for Distributed Systems; Nanostructured MnO2-Based Cathodes for Li-Ion/Polymer Cells; Multi-Layer Laminated Thin Films for Inflatable Structures; Two-Step Laser Ranging for Precise Tracking of a Spacecraft; Growing Aligned Carbon Nanotubes for Interconnections in ICs; Multilayer Composite Pressure Vessels; Texturing Blood-Glucose-Monitoring Optics Using Oxygen Beams; Fault-Tolerant Heat Exchanger; Atomic Clock Based on Opto-Electronic Oscillator; Microfocus/Polycapillary-Optic Crystallographic X-Ray Sys; Depth-Penetrating Luminescence Thermography of Thermal- Barrier Coatings; One-Dimensional Photonic Crystal Superprisms; Measuring Low-Order Aberrations in a Segmented Telescope; Mapping From an Instrumented Glove to a Robot Hand; Application of the Hilbert-Huang Transform to Financial Data; Optimizing Parameters for Deep-Space Optical Communication; and Low-Shear Microencapsulation and Electrostatic Coating.

Source record↗

Space Radiation Cancer Risk Projections and Uncertainties - 2010

Uncertainties in estimating health risks from galactic cosmic rays greatly limit space mission lengths and potential risk mitigation evaluations. NASA limits astronaut exposures to a 3% risk of exposure-induced death and protects against uncertainties using an assessment of 95% confidence intervals in the projection model. Revisions to this model for lifetime cancer risks from space radiation and new estimates of model uncertainties are described here. We review models of space environments and transport code predictions of organ exposures, and characterize uncertainties in these descriptions. We summarize recent analysis of low linear energy transfer radio-epidemiology data, including revision to Japanese A-bomb survivor dosimetry, longer follow-up of exposed cohorts, and reassessments of dose and dose-rate reduction effectiveness factors. We compare these projections and uncertainties with earlier estimates. Current understanding of radiation quality effects and recent data on factors of relative biological effectiveness and particle track structure are reviewed. Recent radiobiology experiment results provide new information on solid cancer and leukemia risks from heavy ions. We also consider deviations from the paradigm of linearity at low doses of heavy ions motivated by non-targeted effects models. New findings and knowledge are used to revise the NASA risk projection model for space radiation cancer risks.

Cucinotta, Francis A.↗

Pulsed Laser System to Simulate Effects of Cosmic Rays in Semiconductor Devices

Spaceflight system electronic devices must survive a wide range of radiation environments with various particle types including energetic protons, electrons, gamma rays, x-rays, and heavy ions. High-energy charged particles such as heavy ions can pass straight through a semiconductor material and interact with a charge-sensitive region, generating a significant amount of charge (electron-hole pairs) along their tracks. These excess charges can damage the device, and the response can range from temporary perturbations to permanent changes in the state or performance. These phenomena are called single event effects (SEE). Before application in flight systems, electronic parts need to be qualified and tested for performance and radiation sensitivity. Typically, their susceptibility to SEE is tested by exposure to an ion beam from a particle accelerator. At such facilities, the device under test (DUT) is irradiated with large beams so there is no fine resolution to investigate particular regions of sensitivity on the parts. While it is the most reliable approach for radiation qualification, these evaluations are time consuming and costly. There is always a need for new cost-efficient strategies to complement accelerator testing: pulsed lasers provide such a solution. Pulsed laser light can be utilized to simulate heavy ion effects with the advantage of being able to localize the sensitive region of an integrated circuit. Generally, a focused laser beam of approximately picosecond pulse duration is used to generate carrier density in the semiconductor device. During irradiation, the laser pulse is absorbed by the electronic medium with a wavelength selected accordingly by the user, and the laser energy can ionize and simulate SEE as would occur in space. With a tightly focused near infrared (NIR) laser beam, the beam waist of about a micrometer can be achieved, and additional scanning techniques are able to yield submicron resolution. This feature allows mapping of all of the sensitive regions of the studied device with fine resolution, unlike heavy ion experiments. The problematic regions can be precisely identified, and it provides a considerable amount of information about the circuit. In addition, the system allows flexibility for testing the device in different configurations in situ.

Aveline, David C.↗

Formation and Stability of Radiation Products in Europa's Icy Shell

Spectra of Europa reveal a surface dominated by water-ice along with hydrated materials and minor amounts of SO2, CO2, and H2O2. Jovian magnetospheric ions (protons, sulfur, and oxygen) and electrons produce significant chemical modifications of the surface on time scales of a few years at micrometer depths. Our laboratory studies examine the formation and stability of radiation products in H2O-rich ices relevant to Europa. Infrared (IR) spectra of ices before and after irradiation reveal the radiation destruction of molecules and the formation of products at 86 - 132 K. In addition, spectra of ices during warming track thermal evolution due to chemical changes and sublimation processes. IR-identified radiation products in 86 - 132 K irradiated H2O + SO2 ices are the bisulfate ion, HSO4(-), sulfate ion, SO4(2-) and the hydronium ion, H3O(+). Warming results in the formation of a residual spectrum similar to liquid sulfuric acid, H2SO4, for H2O:SO2 ratios of 30:1, whereas hydrated sulfuric acid, H2SO4 4 H2O, forms for ratios of 30:1. Radiation products identified for irradiated H2O + H2S ices at 86 K are H2S2 and SO2. When irradiated at 110 and 132 K, ices with H2O:H2S ratios if either 3:1 or 30:1 show the formation of H2SO4 4 H2O on warming to 175 K. We have also examined the radiation stability of H2SO4. Addition of CO2 to H2O + SO2 ices results in the formation of CO3 at 2046 cm (sup -1) (4.89 m). This is the strongest band from a carbon-containing product in the mid-IR spectral region, and it is also seen when either pure CO2 or H2O + CO2 ice is irradiated. Experiments with CH4 added to H2O + SO2 + CO2 ices addressed the question of methane's use as a marker of methanogens in an irradiated ice environment. New results on the near-IR spectrum of pure H2O2 will be included in this presentation. Interpretations of near-IR water bands, with H2O2 present, will be discussed. Irradiations of H2O2 and H2O + H2O2 mixtures, to examine the possibility of O2 and O3 formation, are currently under investigation and new results will be discussed.

Moore, M. H.↗

System and method for voltage-based real-time micro-object position control with the aid of a digital computer

The system and method described allow for real-time control over positioning of a micro-object. A movement of at least one micro-object suspended in a medium can be induced by a generation of one or more forces by electrodes proximate to the micro-object. Prior to inducing the movement, a simulation is used to develop a model describing a parameter of an interaction between each of the electrodes and the micro-object. A function describing the forces generated by an electrode and an extent of the movement induced due to the forces is generated using the model. The function is used to design closed loop policy control scheme for moving the micro-object towards a desired position. The position of the micro-object is tracked and taken into account when generating voltage patterns in the scheme.

Matei, Ion↗

Tracking the Oxidation of Silicon Anodes Using Cryo-EELS upon Battery Cycling

Silicon is a high-capacity material for the anode of a rechargeable lithium-ion battery. One of the fundamental challenges for using Si in anodes is capacity fading, which has been revealed to be partially associated with the interfacial instability between the Si and liquid electrolyte due to the large volume swing of Si upon charging and discharging. Smart nanoscale design concepts, either pre-synthesized or formed in-situ, have led to the mitigation of the detrimental factors associated with the volume swing of Si. However, it has never been clear as how the chemical state of Si evolves and contributes to the capacity fading upon battery cycling. Here, we use cryo-electron energy loss spectroscopy (EELS) to directly monitor, at sub-nanometer scale, the chemical evolution of Si upon battery cycling. We discover that during the cycling process, Si particles are progressively oxidized to form SiO 2 , which is initiated from the particle surface and gradually penetrates toward the interior of the particle, directly contributing to the capacity fading. Possible mechanisms of Si oxidation are postulated. We further show how the cycling stability can be improved by an electrolyte additive to form an effective passivation layer, representatively, even a small concentration of fluoroethylene carbonate (FEC) causes the formation of an LiF layer on the Si nanoparticle surface that prevents Si oxidation and improves cycling stability. Furthermore, the present work unveils Si oxidation as a previously unrecognized factor that contributes to capacity fading, therefore providing insight into the design of anodes with Si based materials.

25 ENERGY STORAGE↗

Recoil imaging for dark matter, neutrinos, and physics beyond the Standard Model

Recoil imaging entails the detection of spatially resolved ionization tracks generated by particle interactions. This is a highly sought-after capability in many classes of detector, with broad applications across particle and astroparticle physics. However, at low energies, where ionization signatures are small in size, recoil imaging only seems to be a practical goal for micro-pattern gas detectors. This white paper outlines the physics case for recoil imaging, and puts forward a decadal plan to advance towards the directional detection of low-energy recoils with sensitivity and resolution close to fundamental performance limits. The science case covered includes: the discovery of dark matter into the neutrino fog, directional detection of sub-MeV solar neutrinos, the precision study of coherent-elastic neutrino-nucleus scattering, the detection of solar axions, the measurement of the Migdal effect, X-ray polarimetry, and several other applied physics goals. We also outline the R&D programs necessary to test concepts that are crucial to advance detector performance towards their fundamental limit: single primary electron sensitivity with full 3D spatial resolution at the $\sim$100 micron-scale. These advancements include: the use of negative ion drift, electron counting with high-definition electronic readout, time projection chambers with optical readout, and the possibility for nuclear recoil tracking in high-density gases such as argon. We also discuss the readout and electronics systems needed to scale-up such detectors to the ton-scale and beyond.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Deep Space Atomic Clock Mission

The Deep Space Atomic Clock (DSAC) mission will demonstrate the space flight performance of a small, low-mass, high-stability mercury-ion atomic clock with long term stability and accuracy on par with that of the Deep Space Network. The timing stability introduced by DSAC allows for a 1-Way radiometric tracking paradigm for deep space navigation, with benefits including increased tracking via utilization of the DSN's Multiple Spacecraft Per Aperture (MSPA) capability and full ground station-spacecraft view periods, more accurate radio occultation signals, decreased single-frequency measurement noise, and the possibility for fully autonomous on-board navigation. Specific examples of navigation and radio science benefits to deep space missions are highlighted through simulations of Mars orbiter and Europa flyby missions. Additionally, this paper provides an overview of the mercury-ion trap technology behind DSAC, details of and options for the upcoming 2015/2016 space demonstration, and expected on-orbit clock performance.

autonomy↗

Amorphization and siliconization of silicon carbide as a first wall material

The understanding and prediction of silicon carbide (SiC) material evolution exposed to SOL plasma conditions is of prime interest because SiC represents a promising main chamber wall plasma-facing material for next-step fusion devices (low hydrogenic diffusion, good mechanical and thermal properties under neutron irradiation). Gross and net Si erosion rates from SiC surfaces in contact with a well-diagnosed L-mode plasma in the DIII-D tokamak have been simulated and the surface concentrations of impurities have been tracked as a function of time. Coupled simulation of surface model and impurity transport demonstrates amorphization of crystalline SiC exposed to L-mode plasma due to the accumulation of displacement damages under ion irradiation. This affects the lifetime of SiC plasma facing components. Surface evolution is tightly coupled to impurity transport in the plasma and therefore needs to be integrated with impurity transport simulations to effectively predict Si erosion rates and sub-surface concentrations as a function of time. The simulation workflow couples a semi-analytical surface model to the impurity transport code GITR. The surface model is a homogeneous mixed-material model that tracks physical & chemical sputtering and reflection of impurities. Gross erosion is primarily influenced by the background plasma parameters and redeposition patterns are mainly influenced by the prompt redeposition due to the gyro-orbits of impurity ions. Although crystalline form of SiC is preferable for fusion wall applications because of resistance to neutron irradiation, this work indicates that crystalline SiC will undergo amorphization under D plasma contact with implications of higher sputtering and fuel retention. These results direct us to explore the effects of amorphization on crystalline SiC and further the physics basis of SiC usage as first wall material for fusion environments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Lithium-Ion Battery Supply Chain for E-Drive Vehicles in the United States: 2010–2020

Understanding the battery supply chain is particularly important for the strategic planning and development of a battery recycling infrastructure to secure critical materials supply and enable a circular economy. Argonne has been tracking plug-in electric vehicle (PEV) sales in the United States (U.S.) by make and model since December 2010, when the Chevrolet Volt and Nissan Leaf were first sold in the U.S. Building on detailed monthly sales data, this report summarizes the manufacturing and production locations of lithium-ion (Li-ion, or LIB) battery cells and packs by make and model for PEVs sold in the U.S. from 2010 to 2020. It also summarizes the annual and cumulative Li-ion battery capacity installed in hybrid electric vehicles (HEVs) sold in the U.S. Overall, there are about 20 different battery cell and pack manufacturers, which are currently supplying about 20 gigawatt-hours (GWh) of batteries annually for the U.S. PEV market. Panasonic and LG Chem are the largest cell suppliers to the U.S. market. Beyond the U.S, South Korea and Japan are major countries supplying PEV batteries to the U.S. market.

25 ENERGY STORAGE↗