Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Modal Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Sonic fatigue testing of an advanced composite aileron

The sonic fatigue test program to verify the design of the composite inboard aileron for the L-1011 airplane is described. The composite aileron is fabricated from graphite/epoxy minisandwich covers which are attached to graphite/epoxy front spar and ribs, and to an aluminum rear spar with fasteners. The program covers the development of random fatigue data by means of coupon testing and modal studies on a representative section of the composite aileron, culminating in the accelerated sonic fatigue proof test. The composite aileron sustained nonlinear panel vibration during the proof test without failure. Viscous damping coefficients as low as 0.4% were measured on the panels. The effects of moisture conditioning and elevated temperature on the random fatigue life of both undamaged and impact damaged coupons were investigated. The combination of impact damage, moisture, and a 180 F temperature could reduce the random fatigue life by 50%.

Soovere, J.↗

Environmental loading effects on structures

The environment in which a structure vibrates influences its modal characteristics. Presented herein is experimental modal survey test results on splitter vanes under liquid nitrogen mass-pressure-thermal loading. In particular, shifts in modal frequencies are studied via frequency response functions, power spectral densities, isoplots, quadrature or imaginary plots, and vibration mode shape characteristics generated from strain and acceleration measurements. Analyses have shown that while mass loading lowers the frequencies, increased pressure and lower temperature have opposite effect. Thus, pressurization and cooling of a liquid causes the modal frequencies of the structure in which it is contained to shift upward.

Panossian, H. V.↗

Overview of environmental test plans for Space Station Freedom work package 4

The generation and distribution of electric power for Space Station Freedom (SSF) is critical to the station's success. Work Package 4 (WP-04) has the responsibility for the design, development, test, and delivery of the Electric Power System (EPS) for the SSF. During launch, assembly, and operation, the EPS will be subjected to various environments. A test and verification approach has been developed to assure that the EPS will function in these environments. An overview of that test program is presented with emphasis on environmental testing of hardware. Two key areas of the test program are highlighted in the overview. One area is the verification of the Solar Power Module (SPM) and associated cargo element hardware. This area includes detailing the plans for development and qualification testing of the SPM hardware. One series of tests, including modal and acoustic, has been completed on a development cargo element. Another area highlighted is the acceptance testing of high-power Orbital Replacement Units (ORU). The environmental test equipment plans are presented and reviewed in light of an aggressive production rate, which delivers ORU's to the WP-04 and other Space Station Work Packages. Through implementing the test program as outlined, the EPS hardware will be certified for flight and operation on the Space Station Freedom.

Peterson, Tom J.↗

Full-Scale Assembly 30 cm Drop Test

Can Spent Nuclear Fuel withstand the shocks and vibrations experienced during normal conditions of transport? This question was the motivation for the multi-modal transportation test (MMTT) (Summer 2017), 1/3-scale cask 30 cm drop test (December 2018), and full-scale assembly 30 cm drop tests (June 2019). The full-scale ENSA ENUN 32P cask with 3 surrogate 17x17 PWR assemblies was used in the MMTT. The 1/3-scale cask was a mockup of this cask. The 30 cm drop tests provided the accelerations on the 1/3-scale dummy assemblies. These data were used to design full-scale assembly drop tests with the goal to quantify the strain fuel rods experience inside a cask when dropped from a height of 30 cm. The drop tests were first done with the dummy and then with the surrogate assembly. This paper presents the preliminary results of the tests.

Transportation↗

Brake lock mechanism for the two axis pointing system

Six months prior to shipment of the Broadband X-ray Telescope to the Kennedy Space Center for flight aboard the Space Shuttle Columbia, a major system failure occurred. During modal survey testing of the telescope's gimbal pointing system, the roll axis brake unexpectedly released. Low level vibration and static preloads present during the modal survey were within the expected flight environment. Brake release during shuttle liftoff or ascent was an unacceptable risk to mission success; thus, a Brake Lock Mechanism (BLM) was developed.

Posey, Alan↗

Predicting System Response at Unmeasured Locations

Traditional techniques to derive dynamic specification for components have a great deal of uncertainty. One of the major sources of uncertainty is that the number of response measurements in the operational system environment is insufficient to determine the component motion. This inadequacy is due to logistical limitations for data recording in field testing and space limitations for accelerometers, strain gages and associated wiring. Available measurements are often some distance from the component and therefore do not represent component motion. Typical straight-line envelopes of these unrepresentative measurements guarantee an increase in the uncertainty. In this paper multiple methods are attempted to expand a sparse set of field test measurements on a system to responses of interest that cannot be measured in the field due to the limitations. Proof of concept is demonstrated on the Modal Analysis Test Vehicle (MATV). The responses of interest, known as “truth responses”, are measured in a system vibration environment along with an optimized sparse set of 30 field responses. Methods to expand the field responses to the truth responses are demonstrated by comparing the acceleration spectral density of the expanded response to the measured response. Two methods utilize a validated finite element model of the MATV. One is developed from purely experiment based frequency response functions of a laboratory pre-test. Finally, these approaches are designed to drastically reduce the uncertainty of the component in-service motion as a basis for developing specifications that are guaranteed to be conservative with a known (instead of unknown) conservatism.

42 ENGINEERING↗

Acoustic Treatment Design Scaling Methods: Test Plans, Hardware, Results, and Evaluation - Volume 3

The ability to design, build, and test miniaturized acoustic treatment panels on scale-model fan rigs representative of the full-scale engine provides not only a cost-savings, but an opportunity to optimize the treatment by allowing tests of different designs. To be able to use scale model treatment as a full-scale design tool, it is necessary that the designer be able to reliably translate the scale model design and performance to an equivalent full-scale design. The primary objective of the study presented in this volume of the final report was to conduct laboratory tests to evaluate liner acoustic properties and validate advanced treatment impedance models. These laboratory tests include DC flow resistance measurements, normal incidence impedance measurements, DC flow and impedance measurements in the presence of grazing flow, and in-duct liner attenuation as well as modal measurements. Test panels were fabricated at three different scale factors (i.e., full-scale, half-scale, and one-fifth scale) to support laboratory acoustic testing. The panel configurations include single-degree-of-freedom (SDOF) perforated sandwich panels, SDOF linear (wire mesh) liners, and double-degree-of-freedom (DDOF) linear acoustic panels.

Yu, J.↗

Emission Performance of Low Cetane Naphtha as Drop-In Fuel on a Multi-Cylinder Heavy-Duty Diesel Engine and Aftertreatment System

With higher volatility and longer ignition delay characteristics than typical diesel fuel, low cetane naphtha fuel has been shown to promote partially premixed combustion and produce lower soot for improved fuel economy. In this study, emission performance of low cetane, low octane naphtha (CN 35, RON 60) as a drop-in fuel was examined on a MY13 Cummins ISX15 6-cylinder heavy-duty on-highway truck engine and aftertreatment system. Using the production hardware and development calibrations, both the engine-out and tailpipe emissions of naphtha and ultra-low sulfur diesel (ULSD) fuels were examined during the EPA s heavy-duty emission testing cycles. Without any modification to the calibrations, the tailpipe emissions were comparable when using naphtha or ULSD on the heavy duty Federal Test Procedure (FTP) and ramped modal cycle (RMC) test cycles. Overall lower CO2 emissions and fuel consumption were also measured for naphtha due in part to its higher heating value and higher hydrogen to carbon ratio. Engine-out and tailpipe NOx emissions were lower for naphtha fuel at the same catalyst conversion levels and measured particulate matter (PM) emissions were also lower when using naphtha due to its higher volatility and lower aromatic content compared to ULSD. To help assess the potential impact on diesel particulate filter design and operation, engine-out PM samples were collected and characterized at the B50 operating point. A significant reduction in elemental carbon (EC) within the particulate emissions was found when using naphtha compared to ULSD.

LeePhD, John↗

Dynamic Characterization of an Inflatable Concentrator for Solar Thermal Propulsion

An inflatable structural system that is a technology demonstrator for solar thermal propulsion and other applications is characterized for structural dynamic behavior both experimentally and computationally. The inflatable structure is a pressurized assembly developed for use in orbit to support a Fresnel lens or inflatable lenticular element for focusing sunlight into a solar thermal rocket engine. When the engine temperature reaches a pre-set level, the propellant is injected into the engine, absorbs heat from an exchanger, and is expanded through the nozzle to produce thrust. The inflatable structure is a passively adaptive system in that a regulator and relief valve are utilized to maintain pressure within design limits during the full range of orbital conditions. Modeling and test activities are complicated by the fact that the polyimide film material used for construction of the inflatable is nonlinear, with modulus varying as a function of frequency, temperature, and level of excitation. Modal vibration testing and finite element modeling are described in detail in this paper. The test database is used for validation and modification of the model. This work is highly significant because of the current interest in inflatable structures for space application, and because of the difficulty in accurately modeling such systems.

Leigh, Larry↗

Surrogate Assembly 30 cm Drop Test

The 30 cm drop is the remaining NRC normal conditions of transport (NCT) regulatory requirement (10 CFR 71.71) for which there are no data on the actual surrogate fuel. While obtaining data on the actual fuel is not a direct requirement, it provides definitive information which aids in quantifying the risk of fuel breakage resulting from a cask drop from a height of 30 cm or less. The 30 cm drop test with the full-scale surrogate assembly conducted in May 2020 was the last step needed for quantifying the strains on the surrogate assembly rods under NCT. The full-scale surrogate assembly used in the 2020 30 cm drop test was built using a new 17x17 Pressurized Water Reactor (PWR) Westinghouse skeleton filled with the copper rods and 3 zircaloy rods from the full-scale surrogate assembly used in the Multi-Modal Transportation Test (MMTT). Felt pads were attached to the surrogate assembly bottom prior to the 30 cm drop to adequately represent the effects of the impact limiters and the cask. Note that felt "programming material" has been used extensively in past drop tests and is known to be a good material for programming a desired shock pulse. The felt pad configuration was determined during a previous series of tests reported in. The acceleration pulses observed on the surrogate assembly during the test were in good agreement with the expected pulses. This confirmed that during the 30 cm drop the surrogate assembly experienced the same conditions as it would if it was dropped in the cask with the impact limiters.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Galileo spacecraft modal identification using an eigensystem realization algorithm

A modal parameter identification technique referred to as the Eigensystem Realization Algorithm (ERA) was applied to free-response measurements from the Galileo spacecraft modal survey test. The data were recorded following single-point random excitation of the structure. This work is one phase in a research project coordinated by the Jet Propulsion Laboratory to compare the performance of various contemporary identification techniques using Galileo data. Principal emphasis is placed on estimating the accuracy of the ERA-identified modal parameters. Various accuracy indicators, such as Modal Amplitude Coherence and Modal Phase Collinearity, are discussed. More than 20 modes of the spacecraft were identified, demonstrating the ability of the ERA method to determine the dynamics of such complex structures using only a few seconds of test data.

Pappa, R. S.↗

Nonlinear Modeling of Joint Dominated Structures

The development and verification of an accurate structural model of the nonlinear joint-dominated NASA Langley Mini-Mast truss are described. The approach is to characterize the structural behavior of the Mini-Mast joints and struts using a test configuration that can directly measure the struts' overall stiffness and damping properties, incorporate this data into the structural model using the residual force technique, and then compare the predicted response with empirical data taken by NASA/LaRC during the modal survey tests of the Mini-Mast. A new testing technique, referred to as 'link' testing, was developed and used to test prototype struts of the Mini-Masts. Appreciable nonlinearities including the free-play and hysteresis were demonstrated. Since static and dynamic tests performed on the Mini-Mast also exhibited behavior consistent with joints having free-play and hysteresis, nonlinear models of the Mini-Mast were constructed and analyzed. The Residual Force Technique was used to analyze the nonlinear model of the Mini-Mast having joint free-play and hysteresis.

Chapman, J. M.↗

Initial test results on state estimation on the SCOLE mast

Modal state estimation tests are performed on the SCOLE mast for the fixed Shuttle platform case. Kalman filter state estimation results from a five mode computer model of the SCOLE mast, developed from a finite element analysis, are compared with those state estimates obtained from laboratory tests. Two comparison runs are presented, one an excitation of the first two bending modes, another, an excitation of the first torsional mode of the mast. Results from both runs show poor agreement in modal estimation between the computer model simulations and the laboratory test data. At present, the reason(s) for this poor performance is unknown. Both the laboratory hardware and software and the computer model are being checked for possible sources of errors. Further computer simulations as well as laboratory testing will be performed.

Sparks, D., Jr.↗

An introduction to a unified approach to flexible rotor balancing

Two types of technique for flexible-rotor balancing are examined: the influence coefficient method, and the modal balancing method. Briefly, the influence coefficient method seeks those correction masses in a predetermined set of planes which will minimize measured vibration (readings) at a series of sensors and speeds, as predicted by influence coefficients relating vibration readings to mass additions; the influence coefficients are normally determined by a series of trial mass tests. The modal balancing method seeks to balance the rotor, one mode at a time, with a set of masses specifically selected not to disturb previously balanced lower modes, the sensitivity to this combination of masses is determined empirically by a series of trial mass tests. The two approaches are compared in supercritical-shaft balancing tests, and some common features are stressed for ultimate incorporation into a unified approach toward flexible-rotor balancing.

Parkinson, A. G.↗

Feasibility Study of SDAS Instrumentation's Ability to Identify Mobile Launcher (ML)/Crawler-Transporter (CT) Modes During Rollout Operations

The Space Launch System (SLS) and its Mobile Launcher (ML) will be transported to the launch pad via the Crawler-Transporter (CT) system. Rollout (i.e., transportation) loads produce structural loads on the integrated SLS/Orion Multi-Purpose Crew Vehicle (MPCV) launch vehicle which are of a concern with respect to fatigue. As part of the risk reduction process and in addition to the modal building block test approach that has been adopted by the SLS Program, acceleration data will be obtained during rollout for use in modal parameter estimation. There are several occurrences where the ML/CT will be transported either into the Vertical Assembly Building (VAB) or to the launch pad and back without the SLS stack as part of the Kennedy Space Center (KSC) Exploration Ground Systems (EGS) Integrated Test and Checkout (ITCO). NASA KSC EGS has instrumentation installed on both the ML and CT to record data during rollout, at the launch pad, and during liftoff. The EGS instrumentation on the ML, which includes accelerometers, is referred to as the Sensor Data Acquisition System (SDAS). The EGS instrumentation on the CT, which also includes accelerometers, is referred to as the CT Data Acquisition System (CTDAS). The forces and accelerations applied to the ML and CT during a rollout event will be higher than any of the planned building block modal tests. This can be very beneficial in helping identify nonlinear behavior in the structure. Developing modal parameters from the same test hardware in multiple boundary conditions and under multiple levels of excitation is a key step in developing a well correlated FEM. The purpose of this study was three fold. First, determine the target modes of the ML/CT in its rollout configuration. Second, determine if the test degrees of freedom (DOF) corresponding to the layout of the SDAS/CTDAS accelerometers (i.e. position and orientation) is sufficient to identify the target modes. Third, determine if the Generic Rollout Forcing Functions (GRFF's) is sufficient for identifying the ML/CT target modes accounting for variations in CT speed, modal damping, and sensor/ambient background noise levels. The finding from the first part of this study identified 28 target modes of the ML/CT rollout configuration based upon Modal Effective Mass Fractions (MEFF) and engineering judgement. The finding from the second part of this study showed that the SDAS/CTDAS accelerometers (i.e. position and orientation) are able to identify a sufficient number of the target modes to support model correlation of the ML/CT FEM. The finding from the third part of this study confirms the GRFFs sufficiently excite the ML/CT such that varying quantities of the defined target modes should be able to be extracted when utilizing an Experimental Modal Analysis (EMA) Multi-Input Multi-Output (MIMO) analysis approach. An EMA analysis approach was used because Operational Modal Analysis (OMA) tools were not available and the GRFFs were sufficiently uncorrelated. Two key findings from this third part of the study are that the CT speed does not show a significant impact on the ability to extract the modal parameters and that keeping the ambient background noise observed at each accelerometer location at or below 30 µgrms is essential to the success of this approach.

Winkel, James P.↗

Illustration of the use of modal assurance criterion to detect structural changes in an Orbiter test specimen

The analysis of empirical modal models of structural components using techniques based on the modal assurance criterion (MAC) defined by Ewins (1984) is discussed and demonstrated for the case of the Space Shuttle Orbiter aft bulkhead. Modal models of the bulkhead are constructed before and after environmental acoustic tests equivalent to 30 or 100 missions and compared (by computing their MACs) to detect significant structural changes; subdivision of the modal vector followed by computation of the MAC for each part is used to localize the changes. Numerical data demonstrating the usefulness of the MAC approach are presented in tables and diagrams.

West, Walter M.↗

TACT: A Set of MSC/PATRAN- and MSC/NASTRAN- based Modal Correlation Tools

This paper describes the functionality and demonstrates the utility of the Test Analysis Correlation Tools (TACT), a suite of MSC/PATRAN Command Language (PCL) tools which automate the process of correlating finite element models to modal survey test data. The initial release of TACT provides a basic yet complete set of tools for performing correlation totally inside the PATRAN/NASTRAN environment. Features include a step-by-step menu structure, pre-test accelerometer set evaluation and selection, analysis and test result export/import in Universal File Format, calculation of frequency percent difference and cross-orthogonality correlation results using NASTRAN, creation and manipulation of mode pairs, and five different ways of viewing synchronized animations of analysis and test modal results. For the PATRAN-based analyst, TACT eliminates the repetitive, time-consuming and error-prone steps associated with transferring finite element data to a third-party modal correlation package, which allows the analyst to spend more time on the more challenging task of model updating. The usefulness of this software is presented using a case history, the correlation for a NASA Langley Research Center (LaRC) low aspect ratio research wind tunnel model. To demonstrate the improvements that TACT offers the MSC/PATRAN- and MSC/DIASTRAN- based structural analysis community, a comparison of the modal correlation process using TACT within PATRAN versus external third-party modal correlation packages is presented.

Marlowe, Jill M.↗

Ground Vibration Testing at NASA Armstrong, Emphasizing on Passive Aeroelastic Tailored Wing Ground Vibration Test Using Fixed Base Correction Method

How does experimental mechanics contribute to aircraft aeroelastic airworthiness? The aviation community is always improving analysis and testing techniques to realize quicker, cheaper, reliable solutions. A ground vibration test (GVT) is conducted to identify structural mode shapes, frequencies, and damping values to validate analytical models used for flutter analysis, which shows whether a structure has acceptable aeroelastic flutter margins for airworthiness. The FLL recently conducted a GVT of the Passive Aeroelastic Tailored (PAT) Wing using an experimental modal technique called Fixed Base Correction (FBC). The GVT objective was to obtain the PAT wing modal characteristics to compare test results with finite element model (FEM) results for the tow-steered wingbox.

loads testing↗