DOE OSTI · 1755128
Full-Scale Assembly 30 cm Drop Test
Abstract
Can Spent Nuclear Fuel withstand the shocks and vibrations experienced during normal conditions of transport? This question was the motivation for the multi-modal transportation test (MMTT) (Summer 2017), 1/3-scale cask 30 cm drop test (December 2018), and full-scale assembly 30 cm drop tests (June 2019). The full-scale ENSA ENUN 32P cask with 3 surrogate 17x17 PWR assemblies was used in the MMTT. The 1/3-scale cask was a mockup of this cask. The 30 cm drop tests provided the accelerations on the 1/3-scale dummy assemblies. These data were used to design full-scale assembly drop tests with the goal to quantify the strain fuel rods experience inside a cask when dropped from a height of 30 cm. The drop tests were first done with the dummy and then with the surrogate assembly. This paper presents the preliminary results of the tests.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Kalinina, Elena A., Ammerman, Douglas J., Grey, Carissa A., Flores, Gregg, Saltzstein, Sylvia J., Klymyshyn, Nicholas A.. 2020-10-01. Full-Scale Assembly 30 cm Drop Test. https://doi.org/10.1557/adv.2019.477
Cite the original work for its findings. Save a collection to share your selection of sources.