Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DC power distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Hot ion plasma heating experiments in SUMMA

Initial results are presented for the hot-ion plasma heating experiments conducted in the new SUMMA (superconducting magnetic mirror apparatus) at NASA Lewis Research Center. A discharge is formed by applying a radially inward dc electric field between cylindrical anodes and hallow cathodes located at the peak of the mirrors. Data were obtained at midplane magnetic field strengths from 1.0 to 3.5 tesla. Charge-exchange neutral particle energy analyzer data were reduced to ion temperatures using a plasma model that included a Maxwellian energy distribution superimposed on an azimuthal drift, finite ion orbits, and radial variations in density and electric field. The best ion temperatures in a helium plasma were 5 keV and in hydrogen the H2(+) and H(+) ions were 1.2 keV and 1 keV respectively. Optical spectroscopy line broadening measurements yielded ion temperatures about 50 percent higher than the charge-exchange neutral particle analyzer results. Spectroscopically obtained electron temperature ranged from 3 to 30 eV. Ion temperature was found to scale roughly linearly with the ratio of power input-to-magnetic field strength, P/B.

Reinmann, J. J.↗

EVs@Scale High-Power Charging (HPC) Pillar Deep-Dive Technical Meeting

EVs@Scale Lab Consortium is addressing challenges, developing solutions, and enabling technologies for transportation electrification ecosystem. The consortium has five research pillars one of which focuses on high power charging (HPC). HPC pillar brings together hardware and software expertise, capabilities, and facilities related to high power EV charging, charge management, and grid integration. Deep-dive technical meetings are organized twice a year and provides an opportunity for more industry engagement and technical feedback for the national labs throughout the project lifecycle. High-Power Charging pillar has two active projects: (i) Next-Gen Profiles (NGP) and (ii) High-Power Electric Vehicle Charging Hub Integration Platform (eCHIP). This presentation summarizes the progress made in both projects during the past six months focusing on specific topics. There will be two deep-dive technical meetings twice a year. Every deep-dive meeting will focus on different aspects of the project progress.

ADVANCED PROPULSION SYSTEMS↗

Anode arc motion in high power arcjets

The long-term operational lifetime of most medium to high power arcjets is currently limited by the rapid deterioration of the arcjet electrodes. To a large extent, the rate of this deterioration is related to the motion of the arc discharge on the electrode surfaces. This paper details a series of experiments aimed at studying the temporal behavior of dc arcs on a water-cooled radially-segmented 30 kW class arcjet anode. The experimental anode used for these tests was made of copper, and was divided into four equivalent radial segments which were electrically isolated with aluminum oxide gaskets. The current carried by each segment was measured independently using four calibrated resistive shunts, and was analyzed by digital computer. The tests were limited to nitrogen propellant over a current range of 100-250 A dc. Results show that for the range of total currents considered here, the current distribution in the segmented arcjet anode is generally asymmetric, exhibiting random fluctuations over a wide range of frequencies.

Harris, W. J.↗

Predictive Direct DC-Link Control for 7.2 kV Three-Port Low-Inertia Solid-State Transformer With Active Power Decoupling

Promising for applications including renewable energy and electric vehicle fast charging, a medium-voltage (MV) solid-state transformer (SST) typically has multiple modules series stacked, which requires the modules to be single phase. One critical issue of the single-phase SST is the double-line-frequency power ripple. Traditionally, large passives are used to buffer the ripple, resulting in significantly increased volume and cost. This article for the first time proposes active power decoupling (APD) for the SST and a predictive direct DC-link control method, using a current-source single-stage SST as an example. An electrolytic capacitor-less buffer port is used to absorb the ripple, which tolerates up to a 30% voltage ripple for small capacitance. The APD SST control is challenging. First, the current-source SST realizes isolation, DC link, and multiport in a single stage. Second, different from conventional SSTs or APD converters, the low-inertia DC link in this SST has a 40% switching ripple, which is difficult to stabilize. To address the control challenge, a direct DC-link control architecture and a predictive control method are proposed. Simulation and experimental results verify the proposed control method on an MV SiC modular soft-switching solid-state transformer (M-S4T) prototype. Here, the proposed APD reduces the SST volume by 53.8%. Importantly, the proposed concept is not limited to the M-S4T but is generic to other SSTs or APD converters.

14 SOLAR ENERGY↗

Magnetic and electric field meters developed for the US Department of Energy

This report describes work done at the Jet Propulsion Laboratory for the Office of Energy Storage and Distribution of DOE on the measurement of power line fields. A magnetic field meter is discussed that uses fiber optics to couple a small measuring probe to a remote readout device. The use of fiber optics minimizes electric field perturbation due to the presence of the probe and provides electric isolation for the probe, so that it could be used in a high field or high voltage environment. Power to operate the sensor electronics is transferred via an optical fiber, and converted to electrical form by a small photodiode array. The fundamental, the second and third harmonics of the field are filtered and separately measured, as well as the broadband rms level of the field. The design of the meter is described in detail and data from laboratory tests are presented. The report also describes work done to improve the performance of a DC bushing in a Swedish factory, using the improved meter. The DC electric fields are measured with synchronous detection to provide field magnitude data in two component directions.

Kirkham, H.↗

DC Arc Incident Energy in Photovoltaic Systems: Methods for Evaluation

Renewable energy systems continue to be one of the fastest growing segments of the energy industry. This article focuses on the understanding of how photovoltaic (PV) technology behaves under dc arc conditions. Emphasis is placed on the electrical safety aspect of dc arc-flash incident energy (IE) evaluation. Because of the fast proliferation of PV systems and lack of formal equivalent calculation guidelines, such as IEEE 1584 for ac systems, it has been necessary to rely on different equations and models presented by various researchers over the last few years. This article discusses the behavior of PV systems under arc conditions and presents the results of the available methods to estimate the dc arc-flash IE. It provides a comparative analysis of a proposed arc-flash IE calculation method against different laboratory tests, including those performed for this article at the National Renewable Energy Laboratory (NREL). Detailed explanations are provided regarding the effect of the PV module current-voltage (I-V) and power-voltage (P-V) curves under arcing conditions. Examples of the application of the proposed calculation method to the test measurements are included.

arc discharges↗

Performance Characterization of InCharge™ ICE-66 V2X Bidirectional DC Fast Charger

Vehicle-to-grid (V2G) technology extends the role of Plug-in Hybrid Vehicle’s (PHEV) and Battery Electric Vehicle’s (BEV) batteries beyond transportation by enabling bidirectional power transfer between the vehicle's onboard energy storage and the utility grid. Modern battery-powered vehicles are equipped with high-capacity battery packs that remain stationary and underutilized for the majority of their operational life. A vehicle used for daily commuting may be parked and connected to charging infrastructure for 18–20 hours per day, representing a significant untapped energy resource. When considered at scale, the aggregated storage capacity of a modest fleet of 10–15 vehicles within a single parking facility can reach the MWh range, sufficient to partially offset peak demand for a mid-size commercial building or contribute meaningful ancillary services to the local grid. The ability to charge during off-peak periods when electricity prices are low and discharge during peak demand when prices are high positions EV batteries as distributed energy arbitrage assets, with the potential to offset vehicle ownership and charging costs. Beyond energy arbitrage, V2G-capable assets can provide ancillary grid services through active and reactive power injections. Active power supports grid frequency regulation, while reactive power supports local voltage regulation. Together, these capabilities establish V2G as a technically promising and economically relevant pathway toward greater integration of battery-powered vehicles into the broader energy system.

33 ADVANCED PROPULSION SYSTEMS↗

EV Charging Infrastructure Energization: An Overview of Approaches for Simplifying Processes and Accelerating Timelines to Processing EV Charging Load Service Requests

The United States has seen significant growth in electric vehicle (EV) adoption, leading to increased demand for EV charging infrastructure and electricity. Growth in electricity demand from EV charging, coupled with growth in other sectors like data centers and electrification of other sectors, is impacting electricity infrastructure and load service request processes after two decades of relatively flat electricity demand. While most electric vehicle charging occurs at home, enroute and depot charging for medium and heavy-duty vehicles, both using high-powered EV charging, are critical to meet electric vehicle operational needs. Over the past decade, EV charging infrastructure site developers, site hosts, and electric distribution utilities have navigated the process to integrate chargers onto the electric grid. Site developers and site hosts have expressed distress that the integration process for high-powered EV charging projects does not meet the needs of the EV market for timeliness or cost. High-powered charging stations typically require a load service request or an agreement with the local utility to connect to the grid. The process of energizing a new high-powered charging site can be complex and time consuming, often taking up to 2 years. This timeline is the result of current utility energization processes having been designed for construction projects that take longer to build (i.e., buildings). The specific challenges stem from various factors, including compartmentalization in application processes, the integration of EV charging process approvals with other distributed energy resources (DERs), and the need to ensure grid reliability. The energization process needs to evolve to meet the growing demand for high-powered EV charging. This white paper compiles information gathered through various conversations with key stakeholders, including utilities, utility regulators, EV charging operators, site developers, and authorities having jurisdiction (AHJ) as well as through an extensive literature review. This document identifies the challenges and provides potential solutions to streamline the process of connecting EV charging infrastructure to the power grid in the United States, serving as a starting point for future conversations around these solutions.

33 ADVANCED PROPULSION SYSTEMS↗

An Integrated High-performance Computing and Digital Real-time Simulation Testbed to Benchmark Closed-loop Load Shedding Algorithms in Power Systems

An integrated testbed using digital real-time simulator (DRTS) and a high-performance computing (HPC) cluster is presented here to compare speed and performance of computational schemes to mitigate time-critical issues in electric power systems. The first approach in this testbed validation is taken by running a set of closed-loop load shedding algorithms to compare and contrast two paradigms of arresting cascading failure propagation. Two algorithms involve solving DC and AC power flow model-based optimization problems to compute load shedding at different buses, while a model-based stochastic search using parallel computing provides a viable alternative. The algorithms are implemented in the DRTS-HPC testbed for the IEEE 14-bus benchmark transmission system. As a proof of the concept, simulation results are presented for implementation of closed-loop load-shedding algorithms for cascading failures in the DRTS-HPC testbed

24 POWER TRANSMISSION AND DISTRIBUTION↗

Small-𝑥 gluon GPD constrained from deeply virtual 𝐽/𝜓 production and gluon PDF through universal-moment parametrization

We phenomenologically constrain the small-𝑥 and small-𝜉 gluon generalized parton distributions (GPDs) with the deeply virtual 𝐽/𝜓 production (DV⁢𝐽/𝜓⁢P) in the framework of GPDs through universal moment parameterization (GUMP). We use a hybrid cross-section formula combining collinear factorization to the next-to-leading order (NLO) accuracy of the strong coupling 𝛼 𝑠 , with corrections from nonrelativistic QCD to account for the power corrections due to the heavy 𝐽/𝜓 mass. We reach reasonable fit to the measured differential cross sections of DV⁢𝐽/𝜓⁢P by H1 at the Hadron-Electron Ring Accelerator as well as forward gluon parton distribution functions (PDFs) from JAM22 global analysis. We find that both NLO and nonrelativistic corrections are significant for heavy vector meson productions. Of course, the gluon GPD we obtain still contains considerable freedom in need of inputs from other constraints, particularly in the distribution-amplitude-like region.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

VSC-HVDC Interties for Urban Power Grid Enhancement

Urban power grids are facing many operational and expansion challenges to meet further demand growth and increased reliability requirements. Advanced transmission technologies have been considered by the electric utilities to effectively increase the utilization of existing infrastructure and operational flexibility. The focus of this paper is on VSC-HVDC technologies for urban power grid enhancement and modernization. First, a potential technical scheme is proposed for converting an existing AC circuit to DC operation, which could boost the power transfer capability of the critical transmission corridor and increase network operational flexibility. Second, this paper proposes three operation modes for the VSC-HVDC interties in urban power grids corresponding to normal, emergency and island operating conditions, respectively. An integrated, adaptive emergency control strategy (AEC) is proposed that can enable adaptive power flow responses of the VSC-HVDC intertie under varying system operating conditions and critical contingencies. The flexibility and effectiveness of the proposed operational principles of urban VSC-HVDC intertie and the corresponding control strategies are verified in PSCAD/EMTDC using a realistic urban power grid in China.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enhanced Bottom Anode Monitoring in DC Electric Arc Furnaces Using Fiber-Optic Sensors

A pin style bottom anode employs conductive steel rods that serve as the pathway for the high electrical power through rammed refractory at the bottom of a DC Electric Arc Furnace (EAF). Anode wear during operation is important to monitor, as anode replacement is expensive and impacts EAF productivity. Liquid steel penetration into the un-sintered refractory layer can result from rapid electrical power ramp-up, dips in furnace temperature, or operating the anode for too long between EAF campaigns. In extreme cases, the liquid steel may penetrate the bottom of the furnace when anode wear progresses too close to the bottom shell, which is extremely dangerous and must be avoided. The current state of the art for monitoring bottom anode wear employs thermocouples imbedded in the anode pins at points in the anode. However, this approach is not sensitive enough to detect localized damage to the anode, especially when cracking occurs. Here, the present work utilizes fiber optic sensors to monitor the health of the anode, by creating a real-time spatially distributed temperature map of the anode. Unlike the traditional thermocouples, these sensors can be mounted at significantly greater depths, provide distributed temperature measurements, and can withstand temperatures of up to 900°C. Additionally, they are able to perform temperature measurements with a spatial resolution of 1.3 mm at a 5 Hz acquisition rate, providing unprecedented high-density real time monitoring of anode health and increasing the efficiency, and safety of EAF operation.

Bottom Anode↗

A Graph-Net with Node Embeddings to Detect False Data Injection Attacks in Photovoltaic Systems

Distributed energy resources (DER) contribute to the operational stability of the larger power grid both at utility-scale as well as commercial and residential scales in aggregated forms. These DER in-turn are susceptible to increasing cyber threats. An adversary can plug into the same local network that a field photovoltaic (PV) system uses to interconnect its data loggers and inverters and manipulate certain measurements collected from the network or trick existing irradiance and inverter readings through false data injection attacks (FDIA). Control routines that rely on these measurements can propagate the false data, impacting critical decisions that result in a suboptimal operation or even cause intentional harm leading to inverter-tripping or unscheduled loads that need to be shed. To detect FDIA in PV systems, the paper introduces an attention-based graph neural network with node embeddings and applied it to a simple prototypical DC-coupled microgrid with PV, energy storage, and load. The algorithm shows a detection accuracy of up to 98.95%. The proposed FDIA detection technique will provide micro-grid operators with an effective method to safeguard their systems, guaranteeing the secure and reliable operation.

Parvez, Imtiaz [Utah Valley University]↗

Nature of convection-stabilized dc arcs in dual-flow nozzle geometry. I - The cold flow field and dc arc characteristics. II - Optical diagnostics and theory

Steady-state low-current air arcs in a dual-flow nozzle system are studied experimentally. The cold flow field with no arc is investigated using a 12.7-mm diameter dual-flow nozzle in a steady-flow facility. Mach number and mass flux distributions are determined for various nozzle-pressure ratios and nozzle-gap spacing. It is found that the shock waves in the converging-diverging nozzles result in a decrease in overal resistance by about 15 percent. Also, Schlieren and differential interferometry techniques are used to visualize the density gradients within the arc plasma and thermal mantle. Both optical techniques reveal a laminar arc structure for a reservoir pressure of 1 atm at various current levels. Experimentally determined axial static pressure and cold-flow mass flux rate distributions and a channel-flow model with constant arc temperatre are used to solve the energy integral for the arc radius as a function of axial distance. The arc electric field strength, voltage, resistance, and power are determined with Ohm's law and the total heat transfer is related to arc power.

Serbetci, Ilter↗

ELECTRIFICATION OF A HEAVY-DUTY OFF-ROAD MATERIAL HANDLER: ENERGY SAVINGS AND EMISSION REDUCTIONS

Federal regulations are driving the adoption of electrification technologies to reduce carbon dioxide equivalent (CO2e) emissions, a metric that quantifies the global warming potential of various greenhouse gases in terms of carbon dioxide (CO2). Although no specific CO2 regulations exist for heavy-duty off-road machines, future reductions are likely, given stricter emissions standards for on-road vehicles. The heavy-duty off-road sector offers significant fuel-saving potential, as its focus has traditionally been on reliability and performance rather than fuel efficiency. This dissertation examines fuel and CO2e savings opportunities on a heavy-duty off-road material handler, the Pettibone Cary-Lift 204i, from stock configuration to simple modifications to a complete teardown and reconfiguration of the machine with a plug-in series hybrid architecture using electrified hydraulics. The study begins by modeling the baseline machine’s fuel and energy consumption, calibrating with experimental data from custom operating cycles. An energy analysis identifies key areas for fuel savings. Two simple powertrain modifications result in a combined 16.2% fuel savings. Next, a Pugh-style analysis narrows a list of electrified architectures, leading to high-fidelity models that evaluate total lifetime CO2e and costs. Higher electrification levels reduce CO2e emissions but increase costs, and electricity grid emissions significantly impact CO2e for plug-in architectures. A plug-in series hybrid is chosen for the project. In its base control form, 49% fuel and 29% CO2e savings are expected from the plug-in series hybrid compared to the baseline machine. Further savings are pursued through regenerative braking (6.3%) and load-following hydraulic control (17.8%), totaling 24.1% fuel savings, and leading to a total of 61% fuel and 41% CO2e savings compared to the baseline. Battery chemistries and charging strategies are also analyzed for cost and CO2e impacts, finding LFP batteries as superior due to longevity, and overnight level 2 charging usually at a lower cost but resulting in higher emissions than opportunity DC fast-charging (DCFC). DCFC emissions are highly dependent on grid emissions, and DCFC cost is highly dependent on grid demand charges. Finally, artificial intelligence is applied to operating cycle recognition. Neural network accuracy ranges from 81% to 99%, with applications to worksite efficiency and safety improvements.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Computationally Improved Heuristic Algorithm for Transmission Switching Using Line Flow Thresholds for Load Shed Reduction

We present a computationally improved heuristic algorithm for transmission switching (TS) to recover load shed. Research from the past showed that changing power system topology may control power flows and remove line congestion. Hence, TS may reduce the required load shed. One of the main challenges is to find a potential TS candidate in a suitable time. Here, we propose a novel heuristic method that is capable of finding the potential TS candidate faster than existing algorithms in literature. The proposed method is compatible with both the AC and DC optimal power flows (OPF). Three metrics are used to compare the proposed algorithm with the state-of-the-art from literature to show the speedup and accuracy achieved. The proposed method is implemented on the IEEE 30-bus system, PEGASE 89-bus system, IEEE 118-bus system, and Polish 2383- bus system. The results on the large-scale Polish 2383-bus system shows that the proposed algorithm is scalable to large real-world systems. Parallel computing is implemented to further improve the computational performance of the proposed algorithm.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cybersecurity Platform and Certification Framework Development for Extreme Fast Charging (XFC)-Integrated Charging Ecosystem (Final Project Report)

This report summarizes a pioneering effort in Electric Vehicle charging infrastructure ecosystem cybersecurity requirements, assessment methodologies, functional verification, as well as embodiment of the key technologies in the form of hardware and software tools being made available to the public. EPRI led a team of experts, as well as a stakeholder coalition encompassing all key actors in the EV charging infrastructure ecosystem that includes eXtreme Fast Charging (XFC) equipment (defined as 200kW or above). EV charging infrastructure in the United States is a patchwork of networks that have continued to grow organically and have been designed to serve the charging needs of the EV owners, who are their customers. In doing so, each network provider, as well as their connected entities such as the cloud Electric Vehicle Service Providers or EVSPs, utility back office, utility AMI networks, payment networks, as well as Original Equipment Manufacturer (EV manufacturer) telematics networks, have designed systems that may work well individually, but no single entity is responsible for the entire ecosystem to be secure in terms of data exchange. Furthermore, there is no uniformity in how each actor has implemented the cybersecurity requirements since no system-wide cybersecurity requirements existed prior to this project. The final project report describes the technical approach guided by the EV charging infrastructure cybersecurity working group, convened specifically for this project. The technical approach included definition of requirements at the ecosystem level, treated as a ‘system of systems’, and then passed down to individual systems (EVSE, EV, cloud EVSP, utility, and the payment networks), followed by developing the cybersecurity risk and vulnerability assessment methods, that were later applied to real-world cyber-physical systems at EPRI, ANL, and NREL laboratories, to validate both the process and the results. Finally, in a spotlight over the most vulnerable equipment, which is the EV charge station (AC or DC), the team developed a multi-layer cybersecurity implementation in the embedded domain embodied by the open-source Secure Network Interface Card (SNIC) demonstrating the various ways in which the infrastructure can be secured protecting against the identified attack surfaces. Finally, the entire process of EV infrastructure cybersecurity assessment was encapsulated in the Electric Vehicle Charging Cybersecurity Management (EVC2M) online GUI-based tool, that is expected to be released to the public. The report presents the objectives, the technical approach, the key results, and recommendations for future work.

24 POWER TRANSMISSION AND DISTRIBUTION↗