Dish Stirling High Performance Thermal Storage FY14Q2 Quad Chart.
Abstract not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Increasing sCO2 power cycle cooler performance will increase the efficiency and lower the cost of electricity for sCO2 power cycles. This work considered the heat transfer performance of two counter-flow, shell-and-tube heat exchangers using local measurements. The heat exchangers were constructed using commercial tubing. One heat exchanger was constructed with a conventional, smooth inner tube (7 mm nominal inner diameter). The other was constructed with an additively manufactured tube with a square cross section and angled rib turbulators. For mixed mean temperatures away from the pseudocritical temperature, the heat transfer coefficient matched the Dittus-Boelter correlation. As the mixed mean temperature approached the pseudocritical temperature, the heat transfer coefficient deviated from the Dittus-Boelter correlation due to transverse property variation and buoyancy. The local and average heat transfer coefficients for angled rib tubes were nominally 150% to 300% greater than the heat transfer coefficients for the smooth tube. Trends in heat exchanger effectiveness indicated that the ribs were most beneficial when the water flow rates were at the low end of the range considered: 0.016 – 0.126 kg/s. Using results from prior system modeling, it is anticipated that adding heat transfer enhancement features in a cycle cooler will increase the sCO2 cycle efficiency by 0.34 percentage points.
Increasing sCO2 power cycle cooler performance will increase the efficiency and lower the cost of electricity for sCO2 power cycles. This work considered the heat transfer performance of two counter-flow, shell-and-tube heat exchangers using local measurements. The heat exchangers were constructed using commercial tubing. One heat exchanger was constructed with a conventional, smooth inner tube (7 mm nominal inner diameter). The other was constructed with an additively manufactured tube with a square cross section and angled rib turbulators. For the present study, the measured Nusselt number was 30% less than the Dittus-Boelter correlation. The decrease was attributed to heat transfer degradation. The cooler performance was also reported as heat exchanger effectiveness. A factor of two improvement in Nusselt number (94%) relative to smooth conventional tubes was observed, indicating that heat transfer enhancement features (such as the ribs) are a suitable technology to overcome heat transfer degradation in sCO2 coolers. Trends in heat exchanger effectiveness indicated that the ribs were most beneficial when the water flow rates were at the low end of the range considered: 0.016 – 0.126 kg/s. Using results from prior system modeling, it is anticipated that adding heat transfer enhancement features in a cycle cooler will increase the sCO2 cycle efficiency by 0.34 percentage points.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Thermal performance evaluation tests on the Small Helium Cooled Infrared Telescope (IRT), prior to flight on Spacelab 2 in 1985, are reported. The telescope is a joint project of the Smithsonian Astrophysical Observatory, the University of Arizona, and the NASA-Marshall Space Flight Center. Starting with 190 liters of liquid helium to be converted to superfluid, 140 liters should be available at launch; 100 liters would be available 48 hours into the mission when first observations begin and 30 liters should be left as a reserve at payload deactivation. New data and insight have been gained regarding the processes which govern the functioning of a porous plug phase separator for superfluid helium.
The thermal performance of a commercial nuclear spent fuel dry storage cask is evaluated through detailed analytical modeling. These modeling efforts are performed by the vendor to demonstrate the performance as well as regulatory compliance and are independently verified by the Nuclear Regulatory Commission (NRC). The majority of commercial dry storage casks in use today are aboveground. Cooling of the assemblies located inside the sealed canister is achieved by air flowing in the bottom of the cask and exiting out the top. Carefully measured data sets generated from testing of full sized casks or smaller cask analogs are widely recognized as vital for validating design and performance models. Numerous studies have been previously conducted. Recent advances in dry storage cask designs have significantly increased the maximum thermal load allowed in a cask in part by increasing the efficiency of internal conduction pathways and by increasing the internal convection through greater canister helium pressure. These vertical, canistered cask systems rely on ventilation between the canister and the overpack to convect heat away from the canister to the environment for both above and belowground configurations. While several testing programs have been previously conducted, these earlier validation attempts did not capture the effects of elevated helium pressures or accurately portray the external convection of aboveground and belowground canistered dry cask systems. Thus the enhanced performance of modern dry storage casks cannot be fully validated using previous studies. The purpose of the investigation described in this report is to produce data sets for the validation of assumptions associated with the thermal-hydraulic simulation of modern dry cask storage systems. Of particular interest are the steady-state cladding temperatures and the effect of elevated helium pressures in sealed canisters in both above and belowground designs. An existing electrically heated but otherwise prototypic BWR Incoloy-clad test assembly will be deployed inside of a representative storage basket and cylindrical pressure vessel that will represent the canister. The arrangement of a single assembly with well-controlled boundary conditions should simplify interpretation of results. Various arrangements of outer concentric ducting will be used to mimic conditions for above and belowground storage configurations of vertical, dry cask systems with canisters. Radial and axial temperature profiles will be measured for a wide range of decay power and helium cask pressures. As of this writing, the apparatus is currently under construction at Sandia National Laboratories in Albuquerque, NM and is expected to be operational starting in April 2016. Pre-test CFD calculations have been performed using best available information. These calculations are being used to assist in test design but will need to be validated and potentially reevaluated. The planned testing will be adjusted to reflect as-built conditions and measured system limitations. Dimensional analyses indicate that the anticipated ranges of relevant dimensionless groups (Reynolds, Modified Rayleigh, and Nusselt numbers) bracket or closely approach prototypic values for both the aboveground and belowground configurations. While designed to match prototypic values, the expected test matrix will include values that exceed currently acceptable values for decay heat, internal helium pressure, and peak cladding temperatures in order to gain more insight into the underlying behavior of the system. (authors)
Phytoplankton respond to their environment through genetic adaptation and plasticity to maintain fitness. This poses challenges when growing microalgae for industrial applications because, inherently, outdoor mass cultivation may lead to adaptations that alter desirable phenotypic traits and environmental niches. Here, we used common garden experiments to quantify the plasticity and adaptive responses to seasonal and geographic climate variation of Nannochloropsis, a microalga commonly used in biotechnology. An initially monoclonal strain was grown outdoors across four locations in Hawaii, Texas, California, and New Mexico. Following 17 and 22 months of cultivation outdoors, we collected samples during winter and summer, respectively, and we compared strains' growth from the four sites across temperature and light gradients in the laboratory. Despite hundreds of generations of exposure to divergent climates, with ~20°C and three-fold differences in daily light intensity, strains showed only minor differences in performance. Thermal performance varied more among seasons than sites, whereas light performance varied with both season and site. Our study indicates that Nannochloropsis exhibits broad plasticity in response to light and temperature, which may inhibit genetic adaptation in space or time. Highly variable field conditions, with daily and seasonal climate fluctuations, may favor plasticity and prevent the rapid adaptation often seen in laboratory studies of microorganisms in constant environments.
Concentrated solar power (CSP) plants have the potential to provide 24 h, renewable electricity. Current CSP systems have high capital and operational costs which makes the levelized cost of electricity uncompetitive with conventional techniques. Recent experimental research has shown the potential of small unit cells (up to 2 × 2 cm) containing micropin arrays (D H < 1 mm) to operate efficiently at high incident flux (>140 W cm -2 ) using supercritical carbon dioxide as the working fluid. Applying this technology to CSP systems would result in a smaller central receiver, which would reduce thermal losses, increase receiver efficiency and reduce the capital cost of the receiver component. This study investigates and addresses the practical thermal and hydraulic issues in numbering up these small unit cells into numerous parallel cells within an integrated module design. A thermal hydraulic network model is developed to quantify the distribution and the overall receiver efficiency of an integrated module. This model is used to specify maximum allowable unit cell size and header dimensions to maintain acceptable thermal performance and pressure loss. Once a module design was finalized, parametric studies were performed to study the effects of varying incident flux on flow distribution and thermal performance of the module. Finally, the results show that an integrated module design can be achieved with less than 5% flow maldistribution and a pressure drop acceptable to the remainder of the system.
Abstract not provided.
Thermal ice protection systems use heat energy to prevent a dangerous buildup of ice on an aircraft. As aircraft become more efficient, less heat energy is available to operate a thermal ice protections system. This requires that thermal ice protection systems be designed to more exacting standards so as to more efficiently prevent a dangerous ice buildup without adversely affecting aircraft safety. While the effects of altitude have always beeing taked into account in the design of thermal ice protection systems, a better understanding of these effects is needed so as to enable more exact design, testing, and evaluation of these systems.
Thermal ice protection systems use heat energy to prevent a dangerous buildup of ice on an aircraft. As aircraft become more efficient, less heat energy is available to operate a thermal ice protections system. This requires that thermal ice protection systems be designed to more exacting standards so as to more efficiently prevent a dangerous ice buildup without adversely affecting aircraft safety. While the effects of altitude have always beeing taked into account in the design of thermal ice protection systems, a better understanding of these effects is needed so as to enable more exact design, testing, and evaluation of these systems.
The space flight testing of a large, flat, flexible panel solar array is examined. The experiment objectives are: to demonstrate the functional operational of the wind deployment and packaging system; Electrical performance; Thermal performance; and dynamic performance. A complete description of the experiment and the flight results are given.