Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “material standards”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Plasma enhanced atomic layer batch processing of aluminum doped titanium dioxide

Among many promising high-k dielectrics, TiO{sub 2} is an interesting candidate because of its relatively high k value of over 40 and its easy integration into existing semiconductor manufacturing schemes. The most critical issues of TiO{sub 2} are its low electrical stability and its high leakage current density. However, doping TiO{sub 2} with Al has shown to yield significant improvement of layer quality on Ru electrodes [S. K. Kim et al., Adv. Mater. 20, 1429 (2008)]. In this work we investigated if atomic layer deposition (ALD) of Al doped TiO{sub 2} is feasible in a batch system. Electrical characterizations were done using common electrode materials like TiN, TaN, or W. Additionally, the effect of plasma enhanced processing in this reactor was studied. For this investigation a production batch ALD furnace has been retrofitted with a plasma source which can be used for post deposition anneals with oxygen radicals as well as for directly plasma enhanced ALD. After evaluation of several Ti precursors a deposition process for AlTiO{sub x} with excellent film thickness and composition uniformity was developed. The effects of post deposition anneals, Al{sub 2}O{sub 3} interlayers between electrode and TiO{sub 2}, Al doping concentration, plasma enhanced deposition and electrode material type on leakage current density are shown. An optimized AlTiO{sub x} deposition process on TaN electrodes yields to leakage current density of 5 x 10{sup -7} A/cm{sup 2} at 2 V and k values of about 35. Thus, it could be demonstrated that a plasma enhanced batch ALD process for Al doped TiO{sub 2} is feasible with acceptable leakage current density on a standard electrode material.

36 MATERIALS SCIENCE↗

Developing 226 Ra and 227 Ac age-dating techniques for nuclear forensics to gain insight from concordant and non-concordant radiochronometers

The model age or ‘date of purification’ of a nuclear material is an important nuclear forensic signature. In this study, chemical separation and MC-ICP-MS measurement techniques were developed for 226 Ra and 227 Ac: grand-daughter nuclides in the 238 U and 235 U decay chains respectively. The 230 Th- 234 U, 226 Ra- 238 U, 231 Pa- 235 U, and 227 Ac- 235 U radiochronometers were used to calculate model ages for CRM-U100 standard reference material and two highly-enriched pieces of uranium metal from the International Technical Working Group Round Robin 3 Exercise. In conclusion, the results demonstrate the accuracy of the 226 Ra- 238 U and 227 Ac- 235 U chronometers and provide information about nuclide migration during uranium processing.

07 ISOTOPE AND RADIATION SOURCES↗

Adapting Nuclear Forensics from Light Water to Molten Salt Reactors: A Survey of Emerging Needs

Rising interest in molten salt reactors for commercial power production presents an opportunity to evaluate the techniques used to characterize materials of nuclear forensic interest. Since extensive research has been performed to identify and develop signatures of light water reactor (LWR) materials (e.g. uranium ore concentrates and uranium dioxide fuel pellets), we use this as a basis to explore possibilities for molten salt signature development. Through this comparative method, nuclear forensic signatures used today to identify the provenance of nuclear materials found out of regulatory control are adapted to molten salt reactor (MSR) fuel cycle materials. Radiological, elemental composition, isotopic composition, and model age signatures will likely not need large adaptations before being applied to MSR materials but may need to expand to be applicable to both thorium- and uranium-fueled systems. The liquid nature of molten salt fuel may erase signatures related to production and irradiation history that are informative for typical LWR materials. However, it may also lead to opportunities for new signatures, such as cooling rate–controlled morphology. Targets identified for further research include radiological attributes of fuel salts; elemental, chemical, and isotopic analysis of salts with differing production routes; morphological effects of various thermodynamic environments; and relevant fuel cycle radiochronometers. Additionally, the comparative nature of the proposed signatures implies a need for MSR-relevant databases and the production of salt standard reference materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SU-G-206-07: Dual-Energy CT Inter- and Intra-Scanner Variability Within One Make and Model

Purpose: It can be logistically quite difficult to scan patients on the same exact device for their repeat visits in multi-scanner facilities. The reliability between dual-energy CT scanners’ quantitative results is not known, nor is their individual repeatability. Therefore, we evaluated inter- and intra-scanner variability with respect to several key clinical quantitative metrics specific to dual-energy CT. Methods: Eleven identical GE HD-750 CT scanners in a busy clinical environment were used to perform dual-energy (DE) CT scans of a large elliptical quality control (QC) phantom (Gammex, Inc.; Middleton, WI) which contains many standard insert materials. The DE-QC phantom was scanned bi-weekly during 2016; 3 to 4 scans were obtained from each scanner (a total of 35 data sets were used for analysis). Iodine accuracy for the 2mg/ml, 5mg/ml and 15mg/ml rods (from the Iodine(Water) image set) and soft tissue HU (40 HU based on NIST constants) from the 50keV data set were used to assess inter- and intra-scanner variability (standard deviation). Results: Intra-scanner variability average for 2mg/ml Iodine was 0.10 mg/ml (range 0.05–0.15 mg/ml), for 5mg/ml Iodine was 0.12 mg/ml (range 0.07–0.16 mg/ml), for 15 mg/ml Iodine was 0.25 mg/ml (range 0.16–0.37 mg/ml), and for the soft tissue inserts was 2.1 HU (range 1.8–2.6 HU). Inter-scanner variability average for 2mg/ml Iodine was 0.16 mg/ml (range 0.11–0.19 mg/ml), for 5mg/ml Iodine was 0.18 mg/ml (range 0.11–0.22 mg/ml), for 15 mg/ml Iodine was 0.35 mg/ml (range 0.23–0.44 mg/ml), and for the soft tissue inserts was 3.8 HU (range 3.1–4.5 HU). Conclusion: Intra-scanner variability for the iodine and soft tissue inserts averaged 3.1% and 5.2% respectively, and inter-scanner variability for these regions analyzed averaged 5.0% and 9.5%, respectively. Future work will include determination of smallest measurable change and acceptable limits for DE-CT scanner variability over longer time intervals. This research has been supported by funds from Dr. William Murphy, Jr., the John S. Dunn, Sr. Distinguished Chair in Diagnostic Imaging at MD Anderson Cancer Center.

60 APPLIED LIFE SCIENCES↗

Status of emerging standards for removable computer storage media and related contributions of NIST

Standards for removable computer storage media are needed so that users may reliably interchange data both within and among various computer installations. Furthermore, media interchange standards support competition in industry and prevent sole-source lock-in. NIST participates in magnetic tape and optical disk standards development through Technical Committees X3B5, Digital Magnetic Tapes, X3B11, Optical Digital Data Disk, and the Joint Technical Commission on Data Permanence. NIST also participates in other relevant national and international standards committees for removable computer storage media. Industry standards for digital magnetic tapes require the use of Standard Reference Materials (SRM's) developed and maintained by NIST. In addition, NIST has been studying care and handling procedures required for digital magnetic tapes. NIST has developed a methodology for determining the life expectancy of optical disks. NIST is developing care and handling procedures for optical digital data disks and is involved in a program to investigate error reporting capabilities of optical disk drives. This presentation reflects the status of emerging magnetic tape and optical disk standards, as well as NIST's contributions in support of these standards.

Podio, Fernando L.↗

Material and Design Optimization of Printed Melt Wire Arrays

Recent work conducted by the Advanced Sensors and Instrumentation (ASI) program at Idaho National Laboratory resulted in the establishment of in-house capabilities for fabricating and testing new advanced manufactured sensors for measuring irradiation temperatures inside a nuclear test reactor. Though current methods of real-time temperature monitoring (e.g., thermocouples) can still be used, the complexity of the feedthroughs and attachments needed for collecting real time measurements greatly increases the experiment-related costs. On the other hand, passive monitoring techniques can be used for collecting post irradiation temperature measurements by inferring reactor temperatures, based on the melting points of well-characterized materials (i.e., standard melt wires). However, challenges have arisen due to the limited space available for including instrumentation in experiments. To resolve this issue, the ASI program expanded its temperature detection capabilities to include advance manufactured melt wires for post-irradiation temperature measurements. These melt wires can determine reactor temperatures while also accommodating space limitations in irradiation experiments. To improve performance reliability and enhance melt wire readability following irradiation, FY-22 efforts have focused on optimizing the materials used in the encapsulation and printed melt wire array. This report details the design and fabrication tasks, along with the subsequent x ray computed tomography (XCT) evaluation process. The melt wire array consisted of indium with a melting point of 157°C, indium/silver (96/4 at%) with a melting point of 219°C, and tin with a melting point of 230°C. The encapsulation disc was made of vanadium due to its low activation properties and radiation resistance when deployed in nuclear reactors. Additionally, the melt wire design consisted of a ceramic sublayer (alumina disc) to further enhance the XCT post melting images of the printed melt wires. However, when sealing the vanadium container, all three melt wires melted, reflecting the temperature limitations that must be considered when employing metal containers in the sealing process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An apparatus for concurrent measurement of thermoelectric material parameters

We describe an apparatus which concurrently and independently measures the parameters determining thermoelectric material conversion efficiency: the Seebeck coefficient, thermal conductivity, and electrical resistivity. The apparatus is designed to characterize thermoelectric materials which are technologically relevant for waste heat energy conversion, and may operate from room temperature to 400 Degree-Sign C. It is configured so the heat flux is axially confined along two boron nitride rods of known thermal conductance. The Seebeck coefficient and thermal conductivity are obtained in steady-state using a differential technique, while the electrical resistivity is obtained using a four-point lock-in amplification method. Measurements on the newly developed NIST Seebeck standard reference material are presented in the temperature range from 50 Degree-Sign C to 250 Degree-Sign C.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Analysis of Rare Earth Elements in Uranium Using Handheld Laser-Induced Breakdown Spectroscopy (HH LIBS)

In this paper, a portable handheld laser-induced breakdown spectroscopy (HH LIBS) instrument was evaluated as a rapid method to qualitatively analyze rare earth elements in a uranium oxide matrix. This research is motivated by the need for development of a method to perform rapid, at-line chemical analysis in a nuclear facility, particularly to provide a rapid first pass analysis to determine if additional actions or measurements are warranted. This will result in the minimization of handling and transport of radiological and nuclear material and subsequent exposure to their associated hazards. In this work, rare earth elements (Eu, Nd, and Yb) were quantitatively spiked into a uranium oxide powder and analyzed by the HH LIBS instrumentation. This method demonstrates the ability to rapidly identify elemental constituents in sub-percent levels in a uranium matrix. Preliminary limits of detection (LODs) were determined with values on the order of hundredths of a percent. Validity of this methodology was explored by employing a National Institute of Standards and Technology (NIST) standard reference materials (SRM) 610 and 612 (Trace Elements in Glass). Finally, it was determined that the HH LIBS method was able to clearly discern the rare earths elements of interest in the glass or uranium matrices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beamline I11 at Diamond: A new instrument for high resolution powder diffraction

The performance characteristics of a new synchrotron x-ray powder diffraction beamline (I11) at the Diamond Light Source are presented. Using an in-vacuum undulator for photon production and deploying simple x-ray optics centered around a double-crystal monochromator and a pair of harmonic rejection mirrors, a high brightness and low bandpass x-ray beam is delivered at the sample. To provide fast data collection, 45 Si(111) analyzing crystals and detectors are installed onto a large and high precision diffractometer. High resolution powder diffraction data from standard reference materials of Si, {alpha}-quartz, and LaB{sub 6} are used to characterize instrumental performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Molybdenum isotope compositions of uranium ore concentrates by double spike MC-ICP-MS

The molybdenum (Mo) isotope composition of uranium ore concentrate (UOC) has been proposed as a nuclear forensic signature due to the ubiquitous presence of Mo in the nuclear fuel cycle and to the possibility that different UOC production pathways lead to characteristic Mo isotope fractionation. Furthermore, Mo forms a volatile hexafluoride which leads to the retainment of Mo in the nuclear fuel cycle through U enrichment and reactor operation processes. As a result, it is possible that the nuclear fuel cycle generates a rich array of Mo isotope signatures. The first step in interpreting Mo isotope signatures generated during the nuclear fuel cycle is to characterize the Mo isotope composition of starting materials. In this study, a suite of UOC samples were analyzed for their Mo isotope composition in order to constrain the range of Mo isotope compositions entering the front end of the nuclear fuel cycle. Analytical protocols were developed to purify Mo from a U rich matrix prior to Mo isotope analysis by double spike MC-ICP-MS. A >3‰ variation in the 98 Mo/ 95 Mo ratio was observed in the suite of UOC samples with δ 98 Mo ranging from -1.15 to +1.96‰ relative to the NIST 3134 Mo standard reference material. The δ98Mo range observed in the UOC samples is very similar to the δ 98 Mo range observed in crustal igneous rocks and Mo-bearing minerals, suggesting that Mo isotope variability in UOC is driven by variability in the parent U ores. However, Mo isotope fractionation during UOC production is evident with one of the UOC samples being isotopically heavy relative to its parent U ore by 0.75‰, suggesting that different UOC production processes also contribute to the total Mo isotope variability observed. Overall, it is expected that the Mo isotope signatures generated during enrichment and reactor process will be clearly discernible from those generated during UOC production.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Method and apparatus for measuring thermal conductivity of small, highly insulating specimens

A hot plate method and apparatus for the measurement of thermal conductivity combines the following capabilities: 1) measurements of very small specimens; 2) measurements of specimens with thermal conductivity on the same order of that as air; and, 3) the ability to use air as a reference material. Care is taken to ensure that the heat flow through the test specimen is essentially one-dimensional. No attempt is made to use heated guards to minimize the flow of heat from the hot plate to the surroundings. Results indicate that since large correction factors must be applied to account for guard imperfections when specimen dimensions are small, simply measuring and correcting for heat from the heater disc that does not flow into the specimen is preferable. The invention is a hot plate method capable of using air as a standard reference material for the steady-state measurement of the thermal conductivity of very small test samples having thermal conductivity on the order of air.

Miller, Robert A.↗

Instrument for stable high temperature Seebeck coefficient and resistivity measurements under controlled oxygen partial pressure

The transport properties of ceramic materials strongly depend on oxygen activity, which is tuned by changing the partial oxygen pressure (pO 2 ) prior to and during measurement. Within, we describe an instrument for highly stable measurements of Seebeck coefficient and electrical resistivity at temperatures up to 1300 K with controlled oxygen partial pressure. An all platinum construction is used to avoid potential materials instabilities that can cause measurement drift. Two independent heaters are employed to establish a small temperature gradient for Seebeck measurements, while keeping the average temperature constant and avoiding errors associated with pO 2 -induced drifts in thermocouple readings. Oxygen equilibrium is monitored using both an O 2 sensor and the transient behavior of the resistance as a proxy. A pO 2 range of 10 -25 –10 0 atm can be established with appropriate gas mixtures. Seebeck measurements were calibrated against a high purity platinum wire, Pt/Pt–Rh thermocouple wire, and a Bi 2 Te3 Seebeck coefficient Standard Reference Material. To demonstrate the utility of this instrument for oxide materials we present measurements as a function of pO 2 on a 1 % Nb-doped SrTiO 3 single crystal, and show systematic changes in properties consistent with oxygen vacancy defect chemistry. Thus, an approximately 11% increase in power factor over a pO 2 range of 10 -19 –10 -8 atm at 973 K for the donor-doped single crystals is observed.

36 MATERIALS SCIENCE↗

Rapid Quantitation of Ascorbic and Folic Acids in SRM 3280 Multivitamin/Multielement Tablets using Flow-Injection Tandem Mass Spectrometry

RATIONALE: Ascorbic acid (AA) and folic acid (FA) are water-soluble vitamins and are usually fortified in food and dietary supplements. For the safety of human health, proper intake of these vitamins is recommended. Improvement in the analysis time required for the quantitative determination of these vitamins in food and nutritional formulations is desired. METHODS: A simple and fast (~5 min) in-tube sample preparation was performed, independently for FA and AA, by mixing extraction solvent with a powdered sample aliquot followed by agitation, centrifugation, and filtration to recover an extract for analysis. Quantitative detection was achieved by flow-injection (1 L injection volume) electrospray ionization tandem mass spectrometry (ESI-MS/MS) in negative ion mode using the method of standard addition. RESULTS: Method of standard addition was employed for the quantitative estimation of each vitamin in a sample extract. At least 2 spiked and 1 non-spiked sample extract were injected in triplicate for each quantitative analysis. Given an injection-to-injection interval of approximately 2 min, about 18 min was required to complete the quantitative estimation of each vitamin. The concentration values obtained for the respective vitamins in the standard reference material (SRM) 3280 using this approach were within the statistical range of the certified values provided in the NIST Certificate of Analysis. The estimated limit of detections of FA and AA were 13 and 5.9 ng/g, respectively. CONCLUSIONS: Flow-injection ESI-MS/MS was successfully applied for the rapid quantitation of FA and AA in SRM 3280 multivitamin/multielement tablets.

ascorbic acid↗

Particle Size Analysis and Distribution

Scanning Electron Microscope (SEM) is a instrument used for examining samples at magnifications from 32 X to 500,000 X (for our instrument). The SEM is attached with an electron gun and is directed onto the sample. The sample then produces an image where it is read on the monitor. The electron gun is positioned at the top because it needs to shoot at the sample that is being tested. The electrons are then shot in a downward motion traveling through several lenses, such as the condenser lens for a more precise reading. Once the samples have been read by the instrument, it will show a picture that has a certain number of particles. Particle size distribution have many uses that are essential to life habits (health) or even conventional use for example construction. Here are just a few examples of how particle size analysis and distribution are being used even today. This Standard Reference Material (SRM) is primarily intended for use in the calibration of equipment used to measure particle size distributions (PSD) in the 9 μm to 30 μm range. A unit of SRM 1984 consists of a single bottle containing approximately 14 g of tungsten carbide/cobalt powder. Certified values: The PSD values at five mass percentiles were measured by scanning electron microscopy (SEM) and laser light scattering (LLS). The NIST certified PSD values by SEM are listed. These certified values were determined by the measurement of over 10 000 individual particles from three bottles. Comparing the certified NIST SRM 1984 tungsten carbide/cobalt powder with our results are almost identical. This is great because more accurate work can be done and proves that our laboratory is able to reproduce NIST results. In conclusion, the scanning electron microscope is used to capture the sampled element and display it to be counted. Without the use of particle distribution, it would be a difficult time to get necessities such as medicine, asthma pumps, constructing materials, or as simple as ink. Overall, our study is an experimental comparison of the techniques we have in house, which are LLS and SEM (combined with the NIH ImageJ software) using the NIST SRM-1984 as a common, well characterized sample so that we have an idea of how the results from the techniques compare.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of Flow-Injection Tandem Mass Spectrometry for Rapid and High-Throughput Quantitative Determination of B-Vitamins in Nutritional Supplements

The use of flow-injection electrospray ionization tandem mass spectrometry for rapid and high-throughput mass spectral analysis of selected B-vitamins, viz. B1, B2, B3, B5, and B6, in nutritional formulations was demonstrated. A simple and rapid (~5 min) in-tube sample preparation was performed by adding extraction solvent to a powdered sample aliquot followed by agitation, centrifugation, and filtration to recover an extract for analysis. Automated flow injection introduced 1 L of the extracts directly into the mass spectrometer ion source without chromatographic separation. Sample-to-sample analysis time was 60 s representing significant improvement over conventional liquid chromatography approaches which typically require 25-45 min, and often require more significant sample preparation procedures. Quantitative capabilities of the flow-injection analysis were tested using the method of standard additions and NIST standard reference material (SRM 3280) multivitamin/multielement tablets. The quantity determined for each B-vitamin in SRM 3280 was within the statistical range provided for the respective certified values. The same sample preparation and analysis approach was also applied to two different commercial vitamin supplement tablets and proved to be successful in the quantification of the selected B-vitamins as evidenced by an agreement with the labels values and the results obtained using isotope dilution liquid chromatography/mass spectrometry.

59 BASIC BIOLOGICAL SCIENCES↗

Construction materials as a waste management solution for cellulose sludge

Sustainable waste management system for effluents treatment sludge has been a pressing issue for pulp and paper sector. Recycling is always recommended in terms of environmental sustainability. Following an approach of waste valorisation, this work aims to demonstrate the technical viability of producing fiber-cement roof sheets incorporating cellulose primary sludge generated on paper and pulp mills. From the results obtained with preliminary studies it was possible to verify the possibility of producing fiber-cement sheets by replacing 25% of the conventional used virgin long fiber by primary effluent treatment cellulose sludge. This amount of incorporation was tested on an industrial scale. Environmental parameters related to water and waste, as well as tests for checking the quality of the final product was performed. These control parameters involved total solids in suspension, dissolved salts, chlorides, sulphates, COD, metals content. In the product, parameters like moisture, density and strength were controlled. The results showed that it is possible to replace the virgin long fibers pulp by primary sludge without impacts in final product characteristics and on the environment. This work ensures the elimination of significant waste amounts, which are nowadays sent to landfill, as well as reduces costs associated with the standard raw materials use in the fiber-cement industrial sector.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

TEAMER: Results of Investigating Structural Design Concepts and Alternative Materials for a Wave Power System

Included here are materials from a study on the design of a three-body Wave Energy Converter (WEC) utilizing a heave plate, dual Power Take Offs (PTOs), and single point mooring. A material trade study has been conducted to evaluate the effects of introducing various metallic and fiber-reinforced polymer (FRP) elements to the design. The baseline design is C-Power's patented k2 Wave Power System (WPS). This Testing Expertise and Access for Marine Energy Research (TEAMER) Request for Technical Support (RFTS) 9 effort resulted in alternative designs of the WPS center member, the nacelle. The analysis resulting from this study will inform the design of a lightweight structure with lower manufacturing and operating costs that increases energy conversion and power-to-weight ratio of the device. The dataset contains several components: finite element analysis (FEA) data, hand calculations, and CAD models. FEA files includes those used for and generated by finite element simulations. Calculations include hand calculations performed using Microsoft Excel, which assess core laminate properties, buckling, and other structural aspects in accordance with risk management DNV-RP-C201 standards. CAD materials include Solidworks files for parts, assemblies, and drawings of the evaluated models.

16 TIDAL AND WAVE POWER↗

Irradiation creep model for α-Fe: Dislocation climb in the presence of stress fields (Final Report)

Irradiation creep is known to be an important process for structural materials in nuclear environments, potentially leading to creep failure at temperatures where thermal creep is generally negligible. While there is a great deal of data for irradiation creep in steels and zirconium alloys in light water reactor conditions, much less is known for first wall materials under fusion energy conditions. Lacking suitable fusion neutron sources for detailed experimentation, modeling, and simulation can help bridge the dose-rate and spectral-effects gap and produce quantifiable expectations for creep deformation of first wall materials under standard fusion conditions. In this work, we present a comprehensive model for irradiation creep created from merging a crystal plasticity representation of the dislocation microstructure and a defect evolution simulator that accounts for the entire cluster dimensionality space. Both approaches are linked by way of a climb velocity that captures dislocation-biased defect absorption and a dislocation strengthening term that reflects the accumulation of defect clusters in the system. We carry out our study in Fe under first wall fusion reactor conditions, characterized by a fusion neutron spectrum at temperatures between 300 and 800°K.

36 MATERIALS SCIENCE↗