Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “lighting quality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Wavefront Preservation in Soft X-Ray Beamlines for the Advanced Light Source Upgrade

In the 4th generation of X-ray light sources, including Free-Electron Lasers (FEL) and Diffraction-Limited Storage Rings (DLSR), the emittance of the electron beam is small or negligible compared to the emittance of the photon beam produced by insertion devices, thus generating coherent beams of light. Over the next few years, several lightsource facilities will be built or upgraded to produce X-ray beams of unprecedented coherent flux. Delivering these exceptional beams to the sample chambers requires beamline optical systems that are designed to preserve the wavefront properties. Our goal in the Advanced Light Source upgrade project (ALS-U) is to create a new class of beamlines that reach diffraction-limited X-ray optical quality through tightly integrated, efficient optical systems, diagnostics, and adaptive mirrors, thus providing users with new scientific capabilities offered by coherent X-ray light interactions with matter. Herein we describe aspects of the beamlines’ design as they enter the project’s final design phase.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Early Results from GLASS-JWST. V: The First Rest-frame Optical Size–Luminosity Relation of Galaxies at z > 7

We present the first rest-frame optical size–luminosity relation of galaxies at z > 7, using the NIRCam imaging data obtained by the GLASS James Webb Space Telescope Early Release Science (GLASS-JWST-ERS) program, providing the deepest extragalactic data of the ERS campaign. Our sample consists of 19 photometrically selected bright galaxies with m F444W ≤ 27.8 at 7 < z < 9 and m F444W < 28.2 at z ~ 9–15. We measure the size of the galaxies in five bands, from rest-frame optical (~4800 Å) to the UV (~1600 Å) based on the Sérsic model, and analyse the size–luminosity relation as a function of wavelength. Remarkably, the data quality of the NIRCam imaging is sufficient to probe the half-light radius r e down to ~100 pc at z > 7. Given the limited sample size and magnitude range, we first fix the slope to that observed for larger samples in rest-frame UV using Hubble Space Telescope samples. The median size r 0 at the reference luminosity M = –21 decreases slightly from rest-frame optical (600 ± 80 pc) to UV (450 ± 130 pc). We then refit the size–luminosity relation allowing the slope to vary. The slope is consistent with β ~ 0.2 for all bands except F150W, where we find a marginally steeper slope of β = 0.53 ± 0.15. The steep UV slope is mainly driven by the smallest and faintest galaxies. If confirmed by larger samples, it implies that the UV size–luminosity relation breaks toward the faint end, as suggested by lensing studies.

79 ASTRONOMY AND ASTROPHYSICS↗

Image quality prediction - An aid to the Viking lander imaging investigation on Mars

Image quality criteria and image quality predictions are formulated for the multispectral panoramic cameras carried by the Viking Mars landers. Image quality predictions are based on expected camera performance, Mars surface radiance, and lighting and viewing geometry (fields of view, Mars lander shadows, solar day-night alternation), and are needed in diagnosis of camera performance, in arriving at a preflight imaging strategy, and revision of that strategy should the need arise. Landing considerations, camera control instructions, camera control logic, aspects of the imaging process (spectral response, spatial response, sensitivity), and likely problems are discussed. Major concerns include: degradation of camera response by isotope radiation, uncertainties in lighting and viewing geometry and in landing site local topography, contamination of camera window by dust abrasion, and initial errors in assigning camera dynamic ranges (gains and offsets).

Huck, F. O.↗

Lake eutrophication as indicated by ERTS satellite imagery

Light reflectance from water in the laboratory always correlates to the water quality parameter of turbidity. This turbidity is caused by suspended solids in the water and for a particular type of material there is a good correlation between the weight of these suspended solids and turbidity. However, this correlation is different for different types of material. When this suspended material is living green matter as in an eutrophic lake, the changes in reflectance can be detected as changes in brightness on a particular aerial image. Two test sites have shown that there is indeed a good correlation between the brightness on an ERTS image and lake eutrophication.

Scherz, J. P.↗

Comet Science Working Group report on the Halley Intercept Mission

The Halley Intercept Mission is described and the scientific benefits expected from the program are defined. One characteristic of the mission is the optical navigation and resulting accurate delivery of the spacecraft to a desired point near the nucleus. This accuracy of delivery has two important implications: (1) high probability that the mass spectrometers and other in situ measurement devices will reach the cometary ionosphere and the zone of parent molecules next to the nucleus; (2) high probability that sunlit, high resolution images of Halley's nucleus will be obtained under proper lighting conditions. In addition an observatory phase is included during which high quality images of the tail and coma structure will be obtained at progressively higher spatial resolutions as the spacecraft approaches the comet. Complete measurements of the comet/solar wind interaction can be made around the time of encounter. Specific recommendations are made concerning project implementation and spacecraft requirements.

Source record↗

Combustion/particle sizing experiments at the Naval Postgraduate School Combustion Research Laboratory

Particle behavior in combustion processes is an active research area at NPS. Currently, four research efforts are being conducted: (1) There is a long standing need to better understand the soot production and combustion processes in gas turbine combustors, both from a concern for improved engine life and to minimize exhaust particulates. Soot emissions are strongly effected by fuel composition and additives; (2) A more recent need for particle sizing/behavior measurements is in the combustor of a solid fuel ramjet which uses a metallized fuel. High speed motion pictures are being used to study rather large burning particles; (3) In solid propellant rocket motors, metals are used to improve specific impulse and/or to provide damping for combustion pressure oscillations. Particle sizing experiments are being conducted using diode arrays to measure the light intensity as a function of scattering angle; (4) Once a good quality hologram is attained, a need exists for obtaining the particle distributions from hologram in a short period of time. A Quantimet 720 Image Analyzer is being used to reconstruct images.

Powers, John↗

Homoepitaxial ZnO Film Growth

ZnO films have high potential for many applications, such as surface acoustic wave filters, UV detectors, and light emitting devices due to its structural, electrical, and optical properties. High quality epitaxial films are required for these applications. The Al2O3 substrate is commonly used for ZnO heteroepitaxial growth. Recently, high quality ZnO single crystals are available for grow homoepitaxial films. Epitaxial ZnO films were grown on the two polar surfaces (O-face and Zn-face) of (0001) ZnO single crystal substrates using off-axis magnetron sputtering deposition. As a comparison, films were also deposited on (0001) Al2O3 substrates. It was found that the two polar ZnO surfaces have different photoluminescence (PL) spectrum, surface structure and morphology, which strongly influence the epitaxial film growth. The morphology and structure of homoepitaxial films grown on the ZnO substrates were different from heteroepitaxial films grown on the Al2O3. An interesting result shows that high temperature annealing of ZnO single crystals will improve the surface structure on the O-face surface rather than the opposite surface. The measurements of PL, low-angle incident x-ray diffraction, and atomic force microscopy of ZnO films indicate that the O-terminated surface is better for ZnO epitaxial film growth.

Zhu, Shen↗

System Estimates Radius of Curvature of a Segmented Mirror

A system that estimates the global radius of curvature (GRoC) of a segmented telescope mirror has been developed for use as one of the subsystems of a larger system that exerts precise control over the displacements of the mirror segments. This GRoC-estimating system, when integrated into the overall control system along with a mirror-segment- actuation subsystem and edge sensors (sensors that measure displacements at selected points on the edges of the segments), makes it possible to control the GROC mirror-deformation mode, to which mode contemporary edge sensors are insufficiently sensitive. This system thus makes it possible to control the GRoC of the mirror with sufficient precision to obtain the best possible image quality and/or to impose a required wavefront correction on incoming or outgoing light. In its mathematical aspect, the system utilizes all the information available from the edge-sensor subsystem in a unique manner that yields estimates of all the states of the segmented mirror. The system does this by exploiting a special set of mirror boundary conditions and mirror influence functions in such a way as to sense displacements in degrees of freedom that would otherwise be unobservable by means of an edge-sensor subsystem, all without need to augment the edge-sensor system with additional metrological hardware. Moreover, the accuracy of the estimates increases with the number of mirror segments.

Rakoczy, John↗

Optimization of Energy Flow through Synthetic Metabolic Modules and Regulatory Networks in a Model Photosynthetic Eukaryotic Microbe

Photosynthetic organisms have recently gained considerable attention for a role in development of renewable energy sources. Genome-enabled systems biology methods, coupled with functional and synthetic genomics, present opportunities to develop sustainable and economical applications such as fuel production within the next 10 to 15 years. However, optimization of light-driven metabolism for biomass or biofuel production will require a detailed systems biology understanding of photosynthetic processes and cellular metabolism. Genome-scale metabolic models (GEMs) are at the core of systems analysis of cellular processes and form a common organizational framework for analyses of data resulting from functional genomics experimental work and computational studies. Therefore, there is a clear demand for high quality photosynthetic model organisms and the appropriate computational tools that enable systems analysis of light-driven metabolism. Through research conducted we expanded the currently available repertoire of photosynthetic GEMs to include the commercially valuable model diatom Phaeoctylum tricornutum. Diatoms have a peculiar and distinct evolutionary footprint and represent a major eukaryotic lineage that is taxonomically and functionally distinct from green and red algae and vascular plants. Therefore, the true potential for light-driven metabolism aimed at biofuel production remains poorly understood at a systems level for a large subset of the global diversity of photosynthetic organisms. The metabolic capabilities of P. tricornutum were comparatively modeled with those from other photosynthetic groups in order to elucidate the occurrence of metabolic traits within and between phototrophs. Additionally, this research resulted in significant extension of the COnstraints Based Reconstruction and Analysis (COBRA) Toolbox to accommodate the crucial need for infrastructure required for ‘omics data integration and analysis in the context of genome-scale models. Therefore, the proposed research achieved two important goals. First, within the broad scope of photosynthetic organisms, we functionally compared and, as a result, identified cellular processes that require optimization in order to enable deployment as biofuel feedstock. Second, the proposed research resulted in development of key computational infrastructure, which can be further extended to other biological systems, that is currently lacking but necessary for multiple ‘omics data integration.

59 BASIC BIOLOGICAL SCIENCES↗

Atmospheric particulate measurements in Norfolk, Virginia

Characterization of atmospheric particulates was conducted at a site near the center of Norfolk, Virginia. Air quality was measured in terms of atmospheric mass loading, particle size distribution, and particulate elemental composition for a period of 2 weeks. The objectives of this study were (1) to establish a mean level of air quality and deviations about this mean, (2) to ascertain diurnal changes or special events in air quality, and (3) to evaluate instrumentation and sampling schedules. Simultaneous measurements were made with the following instruments: a quartz crystal microbalance particulate monitor, a light-scattering multirange particle counter, a high-volume air sampler, and polycarbonate membrane filters. To assess the impact of meteorological conditions on air quality variations, continuous data on temperature, relative humidity, wind speed, and wind direction were recorded. Particulate elemental composition was obtained from neutron activation and scanning electron microscopy analyses of polycarbonate membrane filter samples. The measured average mass loading agrees reasonably well with the mass loadings determined by the Virginia State Air Pollution Control Board. There are consistent diurnal increases in atmospheric mass loading in the early morning and a sample time resolution of 1/2 hour seems necessary to detect most of the significant events.

Storey, R. W., Jr.↗

Advanced UVOIR Mirror Technology Development for Very Large Space Telescopes

Objective of this work is to define and initiate a long-term program to mature six inter-linked critical technologies for future UVOIR space telescope mirrors to TRL6 by 2018 so that a viable flight mission can be proposed to the 2020 Decadal Review. (1) Large-Aperture, Low Areal Density, High Stiffness Mirrors: 4 to 8 m monolithic & 8 to 16 m segmented primary mirrors require larger, thicker, stiffer substrates. (2) Support System:Large-aperture mirrors require large support systems to ensure that they survive launch and deploy on orbit in a stress-free and undistorted shape. (3) Mid/High Spatial Frequency Figure Error:A very smooth mirror is critical for producing a high-quality point spread function (PSF) for high-contrast imaging. (4) Segment Edges:Edges impact PSF for high-contrast imaging applications, contributes to stray light noise, and affects the total collecting aperture. (5) Segment-to-Segment Gap Phasing:Segment phasing is critical for producing a high-quality temporally stable PSF. (6) Integrated Model Validation:On-orbit performance is determined by mechanical and thermal stability. Future systems require validated performance models. We are pursuing multiple design paths give the science community the option to enable either a future monolithic or segmented space telescope.

Stahl, H. Philip↗

Solutions to Droop and the Green Gap by Novel Carrier Injection

Long-wavelength (green, yellow, red) visible light-emitting diodes (LEDs) have historically been inefficient compared to blue light-emitters in the III-nitrides. This is due to many factors, including poor material quality due to the low growth temperatures required for high Incomposition InGaN quantum wells (QWs), and the polar nature of the III-nitride crystal structure. Spontaneous and piezoelectric polarization in the III-nitrides causes enhanced quantum-confined Stark effect (QCSE), which spatially separates electrons and holes and reduces radiative recombination (ie: light output) from the devices. Polarization in the crystal also induces additional potential barriers that electrons and holes must cross over before entering the QWs where they can recombine to emit light. Both of these polarization effects worsen as emission wavelength increases, making blue III-nitride LEDs are the most efficient and red III-nitride LEDs the least efficient. The focus of this project has been solving the latter polarization-related issue through the implementation of V-defects in long wavelength LEDs. V-defects are morphological defects which are commonly observed in c-plane III-nitrides. They are observed as hexagonal pyramid-shaped depressions on the c-plane surface, with six semipolar sidewalls. They typically form at the apex of threading dislocations (TDs) under conditions of kinetically-limited growth and low growth-temperature. They were initially thought to be detrimental to LED performance and much early work focused on eliminating them entirely from III-nitride devices. However, over the past decade work has emerged that indicate that they can improve LED performance by allowing electrons and holes to bypass the polarization-induced barriers present in the c-plane and directly enter the QWs of an LED. This is due to the semipolar nature of the V-defect sidewall: these sidewalls are thin and lack the polarization-induced barriers which prevent carriers easily moving between layers. V-defects have since been determined to be an efficient avenue by which to inject electrons and holes into the c-plane QWs where they can recombine to emit light. Throughout this project we have explored lateral injection through a variety of methods: simulation (Task 2), epitaxial growth of V-defect and non-V-defect LEDs (Tasks 1, 3, 4, 5, 6), and advanced characterization methods (Task 7). All tasks have been completed. A description of each task completed follows from this section.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Phase-Shifting Liquid Crystal Point-Diffraction Interferometry

Microgravity fluid physics experiments frequently measure concentration and temperature. Interferometers such as the Twyman Green illustrated have performed full-field measurement of these quantities. As with most such devices, this interferometer uses a reference path that is not common with the path through the test section. Recombination of the test and reference wavefronts produces interference fringes. Unfortunately, in order to obtain stable fringes, the alignment of both the test and reference paths must be maintained to within a fraction of the wavelength of the light being used for the measurement. Otherwise, the fringes will shift and may disappear. Because these interferometers are extremely sensitive to bumping, jarring and transmitted vibration, they are typically mounted on optical isolation tables. Schlieren deflectometers or the more recent Shack-Hartmann wavefront sensors also measure concentration and temperature in laboratory fluid flows. Ray optics describe the operation of both devices. In a schlieren system, an expanded, collimated beam passes through a test section where refractive index gradients deflect rays. A lens focuses the beam to a filter placed in the rear focal plane of the decollimating lens. In a quantitative color schlieren system, gradients in the index of refraction appear as colors in the field of view due to the action of the color filter. Since sensitivity is a function of the focal length of the decollimating lens, these systems are rather long and filter fabrication and calibration is rather difficult. A Shack-Hartmann wavefront sensor is an array of small lenslets. Typical diameters are on the order of a few hundred microns. Since these lenslets divide the test section into resolution elements, the spatial resolution can be no smaller than an individual lenslet. Such a device was recently used to perform high-speed tomography of heated air exiting a 1.27 cm diameter nozzle. While these wavefront sensors are very compact, the limited spatial resolution and the methods required for data reduction suggest that a more useful instrument needs to be developed. The category of interferometers known as common path interferometers can eliminate much of the vibration sensitivity associated with traditional interferometry as described above. In these devices, division of the amplitude of the wavefront following the test section produces the reference beam. Examples of these instruments include shearing and point diffraction interferometers. In the latter case, shown schematically, a lens focuses light passing through the test section onto a small diffracting object. Such objects are typically either a circle of material on a high quality glass plate or a small sphere in a glass cell. The size of the focused spot is several times larger than the object so that the light not intercepted by the diffracting object forms the test beam while the diffracted light generates a spherical reference beam. While this configuration is mechanically stable, phase shifting one beam with respect to the other is difficult due to the common path. Phase shifting enables extremely accurate measurements of the phase of the interferogram using only gray scale intensity measurements and is the de facto standard of industry. Mercer and Creath 2 demonstrated phase shifting in a point diffraction interferometer using a spherical spacer in a liquid crystal cell as the diffracting object. By changing the voltage across the cell, they were able to shift the phase of the undiffracted beam relative to the reference beam generated by diffraction from the sphere. While they applied this technology to fluid measurements, the device shifted phase so slowly that it was not useful for studying transient phenomena. We have identified several technical problems that precluded operation of the device at video frame rates and intend to solve them to produce a phase-shifting liquid crystal point-diffraction interferometer operating at video frame rates. The first task is to produce high contrast fringes. Since the diffracted beam is much weaker than the transmitted beam, interferograms have poor contrast unless a dye is added to the liquid crystal to reduce the intensity of the undiffracted light. Dyes previously used were not rigorously characterized and suffered from hysteresis in both the initial alignment state of the device and the electro-optic switching characteristics. Hence, our initial effort will identify and characterize dyes that do not suffer from these difficulties and are readily soluble in the liquid crystal host. Since the ultimate goal of this research is to produce interferometers capable of phase shifting at video frame rates, we will quantify the difference in switching times between ferroelectric and nematic liquid crystals. While we have more experience with nematic crystals, they typically switch more slowly than ferroelectric cells. As part of that effort, we will investigate the difference in the modulation of the interferograms as a function of the type of liquid crystal in the cell. Because the temporal switching response of a liquid crystal cell is directly related its thickness, we intend to explore techniques required to produce cells that are as thin as possible. However, the cells must still produce a total phase shift of two pi radians.

Griffin, DeVon W.↗

405 nm violet-blue light inactivates hepatitis C cell culture virus (HCVcc) in ex vivo human platelet concentrates and plasma

Abstract Added safety measures coupled with the development and use of pathogen reduction technologies (PRT) significantly reduces the risk of transfusion-transmitted infections (TTIs) from blood products. Current approved PRTs utilize chemical and/or UV-light based inactivation methods. While the effectiveness of these PRTs in reducing pathogens are well documented, these can cause tolerable yet unintended consequences on the quality and efficacy of the transfusion products. As an alternative to UV-based approaches, we have previously demonstrated that 405 nm violet-blue light exposure successfully inactivates a variety of pathogens, including bacteria, parasites, and viruses, in both platelet concentrates (PCs) and plasma. Herein, we show that 405 nm light treatment effectively inactivates hepatitis C cell culture virus (HCVcc) by up to ~ 3.8 log10 in small volumes of a variety of matrices, such as cell culture media, PBS, plasma, and PCs with 27 J/cm 2 of light exposure, and total inactivation of HCVcc after 162 J/cm 2 light exposure. Furthermore, we demonstrate that carry-over of media supplemented with fetal bovine serum enhances the production of reactive oxygen species (ROS), providing mechanistic insights to 405 nm light-mediated viral inactivation. Overall, 405 nm light successfully inactivates HCVcc, further strengthening this method as a novel PRT for platelets and plasma.

Science & Technology - Other Topics↗

Gamma Discriminating Scintillation Screens for Digital Transfer Method Neutron Imaging

A collaborative project between Idaho National Laboratory (INL) and Paul-Scherrer Institute (PSI) is investigating a new type of scintillation screen that uses ZnS scintillator material with a dysprosium neutron converter instead of traditional prompt converters such as 6Li. Such a screen exposed to a neutron beam creates a latent image by neutron activation of the dysprosium in the scintillator screen. The activated screen is transported into a camera box allowing the camera to read a digital image from the photons emitted by the activated scintillation screen. Such an imaging system combines modern camera-based system architecture with the approach of traditional indirect transfer method radiography. The results show for the first time that the combination of dysprosium with a scintillation material like ZnS can produce light which is measurable under common camera-based detection conditions and that neutron radiographic images of reasonable quality can be produced. The resolution was poorer than expected at ~ 300 µm, but is on the order of the desired resolution of 100 µm. Potential improvements and additional converter materials may be investigated in the future that could increase the light output and improve spatial resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transistor-to-substrate bond quality

Quantitative measurement of X-ray images of bonded power-transistor chips is accomplished by using light meter, which determines percentage of voids in bond.

Telfer, T. A.↗

White-Light Phase-Conjugate Mirrors as Distortion Correctors

White-light phase-conjugate mirrors would be incorporated into some optical systems, according to a proposal, as means of correcting for wavefront distortions caused by imperfections in large optical components. The proposal was given impetus by a recent demonstration that white, incoherent light can be made to undergo phase conjugation, whereas previously, only coherent light was known to undergo phase conjugation. This proposal, which is potentially applicable to almost any optical system, was motivated by a need to correct optical aberrations of the primary mirror of the Hubble Space telescope. It is difficult to fabricate large optical components like the Hubble primary mirror and to ensure the high precision typically required of such components. In most cases, despite best efforts, the components as fabricated have small imperfections that introduce optical aberrations that adversely affect imaging quality. Correcting for such aberrations is difficult and costly. The proposed use of white-light phase conjugate mirrors offers a relatively simple and inexpensive solution of the aberration-correction problem. Indeed, it should be possible to simplify the entire approach to making large optical components because there would be no need to fabricate those components with extremely high precision in the first place: A white-light phase-conjugate mirror could correct for all the distortions and aberrations in an optical system. The use of white-light phase-conjugate mirrors would be essential for ensuring high performance in optical systems containing lightweight membrane mirrors, which are highly deformable. As used here, "phase-conjugate mirror" signifies, more specifically, an optical component in which incident light undergoes time-reversal phase conjugation. In practice, a phase-conjugate mirror would typically be implemented by use of a suitably positioned and oriented photorefractive crystal. In the case of a telescope comprising a primary and secondary mirror (see figure) white light from a distant source would not be brought to initial focus on one or more imaging scientific instrument(s) as in customary practice. Instead, the light would be brought to initial focus on a phase-conjugate mirror. The phase-conjugate mirror would send a phase-conjugate image back, along the path of the incoming light, to the primary mirror. A transparent, highly efficient diffractive thin film deposited on the primary mirror would direct the phase-conjugate image to the imaging instrument(s).

Frazier, Donald↗

Sprectroscopic and time-resolved optical methods and apparatus for imaging objects in turbed media

Method and apparatus for imaging objects in turbid media. In one embodiment, the method comprises illuminating at least a portion of the turbid medium with substantially monochromatic light of at least two wavelengths in the 600-1500 nm spectral range. A first of the at least two wavelengths is equal to a resonance wavelength for an optical property of an object in the illuminated portion of the turbid medium but is not equal to a resonance wavelength for the turbid medium. A second of the at least two wavelengths is not equal to a resonance wavelength for either the object or the turbid medium. Light emergent from the turbid medium following each of the foregoing illuminations comprises a ballistic component, a snake component and a diffuse component. A direct shadowgram image may be obtained by preferentially passing from the emergent light, following each illumination. the ballistic and snake components thereof and detecting the preferentially passed light. Alternatively, an inverse reconstruction image may be obtained by determining, following each illumination, the intensity of the diffuse component at a plurality of points in time and then using these pluralities of intensity determinations and a mathematical inversion algorithm to form an image of the object in the turbid medium. An image of the object with higher contrast and better quality may be obtained by using the ratio or difference of the images recorded with resonant light and non-resonant light.

Alfano, Robert R.↗