Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PLASMA GENERATOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Coating Solar Cells By Microwave Plasma Deposition

Antireflection films deposited on silicon solar cells at high production rates with microwave-enhanced plasma deposition. Microwave energy at frequency of 2.45 GHz generates plasma in mixture of gases, from which thin film of silicon nitride deposits on silicon substrates. Reaction temperature relatively low (only 250 degrees C), and film deposition rate more than 500 Angstrom/minute - 2 to 5 times faster. Quality of antireflection film similar to that produced by chemical-vapor deposition. Uses less power and consumes smaller quantities of gas. Species formed in plasma longer lived and dissociate reactants in region of chamber well away from plasma-generation region.

Minaee, Behrooz↗

Dependence of optimal initial density on laser parameters for multi-keV x-ray radiators generated by nanosecond laser-produced underdense plasma

Efficient multi-keV x-ray sources can be produced using nanosecond laser pulse-heated middle-Z underdense plasmas generated using gas or foam. Previous experimental results show that an optimal initial target density exists for efficient multi-keV x-ray emission at which the laser ionization wave is supersonic. Here we explore the influence of the laser intensity and the pulse duration on this optimal initial target density via a one-dimensional radiation hydrodynamic simulation. The simulation shows that the optimal initial density is sensitive to both the laser intensity and the pulse duration. However, the speed of the supersonic ionization wave at the end of the laser irradiation is always maintained at 1.5 to 1.7 times that of the ion acoustic wave under the optimal initial density conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A chamber experiment for the feasibility study of an artificial plasma reflector for OTH radar applications

The feasibility of using two intersecting beams for plasma generation in the upper atmosphere as an over-the-horizon radar reflector was investigated. A cube was filled with dry air to a pressure corresponding to the simulated altitude, and two components of a split microwave beam were fed into the cube at right angles. Plasma layers were generated where the two beams intersected. Three critical issues were addressed: (1) reflectivity of the generated plasma layers; (2) propagation of high power microwave pulses; and (3) lifetime of the plasma.

Kuo, S. P.↗

Localization of linear kinetic Alfvén wave in an inhomogeneous plasma and generation of turbulence

This paper presents a model for the propagation of Kinetic Alfvén waves (KAWs) in inhomogeneous plasma when the inhomogeneity is transverse to the background magnetic field. The semi-analytical technique and numerical simulations have been performed to study the KAW dynamics when plasma inhomogeneity is incorporated in the dynamics. The model equations are solved in order to study the localization of KAW and their magnetic power spectrum which indicates the direct transfer of energy from lower to higher wave numbers. The inhomogeneity scale length plays a very important role in the turbulence generation and its level. The relevance of these investigations to space and laboratory plasmas has also been pointed out.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Phase Properties of Laser High-Order Harmonics Generated on Plasma Mirrors

As a high-intensity laser-pulse reflects on a plasma mirror, high-order harmonics of the incident frequency can be generated in the reflected beam. We present a numerical study of the phase properties of these individual harmonics, and demonstrate experimentally that they can be coherently controlled through the phase of the driving laser field. The harmonic intrinsic phase, resulting from the generation process, is directly related to the coherent sub-laser-cycle dynamics of plasma electrons, and thus constitutes a new experimental probe of these dynamics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Langmuir probe measurements and mass spectrometry of plasma plumes generated by laser ablation of La{sub 0.4}Ca{sub 0.6}MnO{sub 3}

The plasma formed in vacuum by UV nanosecond laser ablation of La{sub 0.4}Ca{sub 0.6}MnO{sub 3} in the fluence range of 0.8 to 1.9 J cm{sup −2} using both Langmuir probe analysis and energy-resolved mass spectrometry has been studied. Mass spectrometry shows that the main positive ion species are Ca{sup +}, Mn{sup +}, La{sup +}, and LaO{sup +}. The Ca{sup +} and Mn{sup +} energy distributions are quite broad and lie in the 0–100 eV region, with the average energies increasing with laser fluence. In contrast, the La{sup +} and LaO{sup +} distributions are strongly peaked around 10 eV. The net time-of-arrival signal derived from the measured positive ion energy distributions is broadly consistent with the positive ion signal measured by the Langmuir probe. We also detected a significant number of O{sup −} ions with energies in the range of 0 to 10 eV. The Langmuir probe was also used to measure the temporal variation of the electron density and temperature at 6 cm from the ablation target. In the period when O{sup −} ions are found at this position, the plasma conditions are consistent with those required for significant negative oxygen ion formation, as revealed by studies on radio frequency excited oxygen plasma.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Research and Development to Reduce Impurity Production and Transport of the Impurities to the Target in Linear Plasma Devices Using Helicon Plasma Sources

Linear plasma devices used to test plasma facing materials (PFMs) and components for fusion reactors are often suffering under the production of intrinsic impurities from the plasma source system. Most linear plasma devices use internal electrodes (hollow cathodes, reflex arc, or cascading arc), which typically are the source of the main impurities. The next-generation plasma generators use radio frequency (RF) plasma sources like helicons to avoid internal electrodes. However, high power operation of helicons has proven to result in impurity production due to the high rectified sheath voltages created. Depending on the plasma parameters and magnetic configuration, these impurities can be transported to the target and deposited there to unacceptable high levels. Here, in this contribution, the experimental results from Proto-MPEX are summarized, and the conclusions of the impurity source physics are given. Methods to reduce the impurity production, the impurity transport, and the net deposition on the target are presented. These methods to reduce the impurity production include Faraday screens to reduce the sheath voltage drop, high-Z refractory coatings to reduce the erosion yield, and wall conditioning methods. Methods to reduce the impurity transport include changes in the magnetic configuration as well as electron heating to change axial and radial temperature profiles. Preliminary results on the effectiveness of some of these methods are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electric probe investigations of microwave generated, atmospheric pressure, plasma jets

We examine the applicability of the Langmuir-type of characterization for atmospheric pressure plasma jets generated in a millimeter-size cavity microwave resonator at 2.45 GHz. Wide range I-V characteristics of helium, argon, nitrogen, air and oxygen are presented for different gas fluxes, distances probe-resonator, and microwave powers. A detailed analysis is performed for the fine variation in the current around the floating potential. A simplified theory specially developed for this case is presented, considering the ionic and electronic saturation currents and the floating potential. Based on this theory, we conclude that, while the charge carrier density depends on gas flow, distance to plasma source, and microwave absorbed power, the electron temperature is quite independent of these parameters. The resulting plasma parameters for helium, argon, and nitrogen are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Standing waves along a microwave generated surface wave plasma

Two surface wave plasma columns, generated by microwave power in argon at gas pressures of 0.05 torr to 330 torr, interact in the same discharge tube to form standing surface waves. Radial electric field and azimuthal magnetic field outside the discharge tube are measured to be 90 deg out of phase with respect to axial position and to decay exponentially with radial distance from the tube axis. Maximum light emission occurs at the position of maximum azimuthal magnetic field and minimum radial electric field. Electron temperature and density are measured at low pressures with double probes inserted into the plasma at a null of radial electric field. Measured electron densities compare well with those predicted by Gould-Trivelpiece surface wave theory.

Rogers, J.↗

Effects of Different Waveforms on the Performance of Active Capillary Dielectric Barrier Discharge Ionization Mass Spectrometry

Active capillary dielectric barrier discharge ionization (DBDI) is emerging as a compact, low-cost, and robust method to form intact ions of small molecules for detection in near real time by portable mass spectrometers. Here, we demonstrate that by using a 10 kHz, ~2.5 kV{sub p-p} high-voltage square-wave alternating current plasma, active capillary DBDI can consume less than 1 μW of power. In contrast, the power consumed using a sine and triangle alternating current waveform is more than two orders of magnitude higher than that for the square waveform to obtain a similar voltage for plasma generation. Moreover, the plasma obtained using a square waveform can be significantly more homogenous than that obtained using sine and triangle waveforms. Protonated dimethyl methylphosphonate (DMMP) and deprotonated perfluorooctanoic acid (PFOA) can be detected at about the same or higher abundances using square-wave DBDI mass spectrometry compared with the use of sine and triangle waveforms. By use of benzylammonium thermometer ions, the extent of internal energy deposition using square, sine, or triangle waveform excited plasmas are essentially the same at the optimum voltages for ion detection. Using an H-bridge circuit driving a transformer optimized to reduce losses, square-wave active capillary DBDI can be continuously powered for ~50 h by common 9 V-battery (PP3). .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Temporal characterization of fundamental plasma parameters in pulsed liquid electrode plasma (LEP) optical emission spectrometry

The fundamental characteristics of liquid electrode plasma (LEP), a pulsed plasma source for optical emission spectrometry, were investigated. Two distinct phases were observed during the process of pulsed plasma generation, namely bubble generation and active plasma discharge. Additionally the ionization efficiency of the LEP, with Mg as a representative analyte, was gauged from the ratio of Mg II 279.553 nm to Mg I 285.213 nm emission and was found to increase from about 5% to 20% in a close-to-linear fashion with the discharge voltage from 800 V to 1200 V. The Mg II/Mg I ratio of the LEP was 2.5 to 3 orders of magnitude less than that typically offered by an inductively coupled plasma (ICP) but was comparable to other solution-based glow discharges. It was found that an off-time interval of more than 150 ms between successive discharge pulses was required to obtain a stable pulse-to-pulse discharge current. Temporally resolved emissions of Mg II 279.6 nm, Mg I 285.2 nm, Fe I 373.5 nm, OH band head at 306 nm, and Hα line at 656.3 nm showed that the background species (OH band and Hα line) reached their maximum emission intensities at around 0.5 ms to 0.7 ms with respect to the onset of the discharge pulse whereas the maximum emissions were observed between 0.7 ms to 0.9 ms for analyte species (Mg and Fe lines). The electron density observed in the present work was in the range from 5.7 × 10 15 cm -3 to 8.2 × 10 15 cm -3 , which was similar to those found in an analytical ICP. The temporal averaged OH rotational temperature was 3300 K, which was comparable to the values of an analytical ICP and solution-based glow discharges. By contrast, the temporally averaged Fe I excitation temperature was around 8900 K, which was even higher than that of an analytical ICP and roughly triple the values obtained by techniques based on glow discharge of liquid samples.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A sustained high-temperature fusion plasma regime facilitated by fast ions

Nuclear fusion is one of the most attractive alternatives to carbon-dependent energy sources. Harnessing energy from nuclear fusion in a large reactor scale, however, still presents many scientific challenges despite the many years of research and steady advances in magnetic confinement approaches. State-of-the-art magnetic fusion devices cannot yet achieve a sustainable fusion performance, which requires a high temperature above 100 million kelvin and sufficient control of instabilities to ensure steady-state operation on the order of tens of seconds. Here, in this study, we report experiments at the Korea Superconducting Tokamak Advanced Research device producing a plasma fusion regime that satisfies most of the above requirements: thanks to abundant fast ions stabilizing the core plasma turbulence, we generate plasmas at a temperature of 100 million kelvin lasting up to 20 seconds without plasma edge instabilities or impurity accumulation. A low plasma density combined with a moderate input power for operation is key to establishing this regime by preserving a high fraction of fast ions. This regime is rarely subject to disruption and can be sustained reliably even without a sophisticated control, and thus represents a promising path towards commercial fusion reactors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improvement of a plasma uniformity of the 2nd ion source of KSTAR neutral beam injector

The 2nd ion source of KSTAR (Korea Superconducting Tokamak Advanced Research) NBI (Neutral Beam Injector) had been developed and operated since last year. A calorimetric analysis revealed that the heat load of the back plate of the ion source is relatively higher than that of the 1st ion source of KSTAR NBI. The spatial plasma uniformity of the ion source is not good. Therefore, we intended to identify factors affecting the uniformity of a plasma density and improve it. We estimated the effects of a direction of filament current and a magnetic field configuration of the plasma generator on the plasma uniformity. We also verified that the operation conditions of an ion source could change a uniformity of the plasma density of an ion source.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Estimation of mean electron energy in helium surface ionization waves on dielectric substrates

Abstract The determination of basic plasma parameters in atmospheric pressure discharges is critical to advancing their use in applications. Atmospheric pressure plasma jets have found use in the fields of medicine, agriculture, material modification and others. Atmospheric pressure plasma jets often generate plasma surface ionization waves (SIW) which interact with and propagate over surfaces. Electrical diagnostics are challenging in SIW due to high collision frequencies and small scale of the plasma discharge. This work employs a passive optical emission line ratio technique to estimate the mean electron energy in SIW over planar dielectric substrates. The method uses an intensity ratio of two helium triplet lines: He( 3 3 S ) at 706.5 nm and He( 3 3 D ) at 587.56 nm. A collisional-radiative model is used to correlate line ratio to mean electron energy and determine dependencies on electron density and He/air gas mixture. Mean electron energies ranging from 3–8 eV are determined in He/air mixtures and are found to remain constant as the surface wave propagates radially. This work provides a 2D, time-resolved, mean electron energy diagnostic for surface ionization wave propagation and validation of numerical modeling in atmospheric pressure systems with spatially varying He/air gas mixtures. The model in question is designed for use with any He line ratio in the n = 3 excitation level.

Morsell, Joshua (ORCID:0000000331073002)↗

Plasma convection and ion beam generation in the plasma sheet boundary layer

Because of the dawn-dusk electric field E(dd), plasma in the magnetotail convects from the lobe toward the central plasma sheet (CPS). In the absence of space or velocity diffusion due to plasma turbulence, convection would yield a steady state distribution function f = V exp (-2/3) g(v exp 2 V exp 2/3), where V is the flux tube volume. Starting with such a distribution function and a plasma beta which varies from beta greater than 1 in the CPS to beta much smaller than 1 in the lobe, the evolution of the ion distribution function was studied considering the combined effects of ion diffusion by kinetic Alfven waves (KAW) in the ULF frequency range (1-10 mHz) and convection due to E(dd) x B drift in the plasma sheet boundary layer (PSBL) and outer central plasma sheet (OCPS). The results show that, during the early stages after launching the KAWs, a beamlike ion distribution forms in the PSBL and at the same time the plasma density and temperature decrease in the OCPS. Following this stage, ions in the beams convect toward the CPS resulting in an increase of the plasma temperature in the OCPS.

Moghaddam-Taaheri, E.↗

Dense electron-positron plasmas and bursts of gamma-rays from laser-generated quantum electrodynamic plasmas

In simulations of a 12.5 PW laser (focussed intensity I=4×10{sup 23}Wcm{sup −2}) striking a solid aluminum target, 10% of the laser energy is converted to gamma-rays. A dense electron-positron plasma is generated with a maximum density of 10{sup 26}m{sup −3}, seven orders of magnitude denser than pure e{sup −} e{sup +} plasmas generated with 1PW lasers. When the laser power is increased to 320 PW (I=10{sup 25}Wcm{sup −2}), 40% of the laser energy is converted to gamma-ray photons and 10% to electron-positron pairs. In both cases, there is strong feedback between the QED emission processes and the plasma physics, the defining feature of the new “QED-plasma” regime reached in these interactions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A simple cold Ar plasma jet generated with a floating electrode at atmospheric pressure

An experimental study is presented of a cold atmospheric Ar plasma jet with distinct advantages of low-working voltage and high plasma stability. To effectively improve the performance of the jet, a pair of pin electrodes with one floating in the air is applied. Variation in the applied voltage and/or the Ar gas flow causes the transition of the jet plasma from ignition, through stable plume to an unstable stage. The characteristics of the jet discharge are also studied by means of the electrical and spectroscopic diagnosis.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Radiofrequency plasma antenna generated by femtosecond laser filaments in air

We demonstrate tunable radiofrequency emission from a meter-long linear plasma column produced in air at atmospheric pressure. A short-lived plasma column is initially produced by femtosecond filamentation and subsequently converted into a long-lived discharge column by application of an external high voltage field. Radiofrequency excitation is fed to the plasma by induction and detected remotely as electromagnetic radiation by a classical antenna.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗