Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fire Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Augmented burst-error correction for UNICON laser memory

A single-burst-error correction system is described for data stored in the UNICON laser memory. In the proposed system, a long fire code with code length n greater than 16,768 bits was used as an outer code to augment an existing inner shorter fire code for burst error corrections. The inner fire code is a (80,64) code shortened from the (630,614) code, and it is used to correct a single-burst-error on a per-word basis with burst length b less than or equal to 6. The outer code, with b less than or equal to 12, would be used to correct a single-burst-error on a per-page basis, where a page consists of 512 32-bit words. In the proposed system, the encoding and error detection processes are implemented by hardware. A minicomputer, currently used as a UNICON memory management processor, is used on a time-demanding basis for error correction. Based upon existing error statistics, this combination of an inner code and an outer code would enable the UNICON system to obtain a very low error rate in spite of flaws affecting the recorded data.

Lim, R. S.↗

Next Generation Wiring

Wiring is a major operational component on aerospace hardware that accounts for substantial weight and volumetric space. Over time wire insulation can age and fail, often leading to catastrophic events such as system failure or fire. The next generation of wiring must be reliable and sustainable over long periods of time. These features will be achieved by the development of a wire insulation capable of autonomous self-healing that mitigates failure before it reaches a catastrophic level. In order to develop a self-healing insulation material, three steps must occur. First, methods of bonding similar materials must be developed that are capable of being initiated autonomously. This process will lead to the development of a manual repair system for polyimide wire insulation. Second, ways to initiate these bonding methods that lead to materials that are similar to the primary insulation must be developed. Finally, steps one and two must be integrated to produce a material that has no residues from the process that degrades the insulating properties of the final repaired insulation. The self-healing technology, teamed with the ability to identify and locate damage, will greatly improve reliability and safety of electrical wiring of critical systems. This paper will address these topics, discuss the results of preliminary testing, and remaining development issues related to self-healing wire insulation.

Medelius, Petro↗

Analysis of Risks to Oxygen Systems from Particulate and Fiber Contaminants and Derivation of Cleanliness Requirements

It has been well documented in the literature that contamination within oxygen systems can create significant fire hazards. Cleanliness limits for nonvolatile residues, ranging from 10 to 500 milligrams per square meter, have been established for various industries and types of oxygen systems to reduce the risk of ignition of flammable organic films. Particulate cleanliness limits used for oxygen systems, however, vary considerably, notably within the aerospace industry. Maximum allowed particle size, quantity limits, and allocations for fibers or metallic particles are all variables seen in aerospace cleanliness limits. Particles are known to have the potential to ignite within oxygen systems and must be limited to prevent fires. Particulate contamination may also pose risks to the performance of oxygen systems that are unrelated to ignition hazards. An extensive literature search was performed to better understand the relative importance of particle ignition mechanisms versus other deleterious effects of particles on oxygen systems and to identify rationale for derivation of particulate cleanliness limits for specific systems. The identified risks of different types and sizes of particles and fibers were analyzed. This paper summarizes the risks identified and rationale that may be used to derive particulate cleanliness limits for specific oxygen systems.

Lowrey, Nikki M.↗

Operation and Development Status of the Spacecraft Fire Experiments (Saffire)

Since 2012, a series of Spacecraft Fire Experiments (Saffire) have been under development by the Spacecraft Fire Safety Demonstration (SFS Demo) project, funded by NASA's Advanced Exploration Systems Division. The overall objective of this project is to reduce the uncertainty and risk associated with the design of spacecraft fire safety systems for NASA's exploration missions. The approach to achieving this goal has been to define, develop, and conduct experiments that address gaps in spacecraft fire safety knowledge and capabilities identified by NASA's Fire Safety System Maturation Team. The Spacecraft Fire Experiments (Saffire-I, -II, and -III) are material flammability tests at length scales that are realistic for a spacecraft fire in low-gravity. The specific objectives of these three experiments are to (1) determine how rapidly a large scale fire grows in low-gravity and (2) investigate the low-g flammability limits compared to those obtained in NASA's normal gravity material flammability screening test. The experiments will be conducted in Orbital ATK's Cygnus vehicle after it has unberthed from the International Space Station. The tests will be fully automated with the data downlinked at the conclusion of the test before the Cygnus vehicle reenters the atmosphere. This paper discusses the status of the Saffire-I, II, and III experiments followed by a review of the fire safety technology gaps that are driving the development of objectives for the next series of experiments, Saffire-IV, V, and VI.

Fire Safety↗

Directory of workers in the fire field

A directory was compiled to provide a list of workers engaged in fire research, their addresses and affiliations, and their principal fields of activity. The initial criteria for the selection of names for the directory are recent contributions to fire literature, teaching of subjects relevant to fire science, or participation in or support of fire research programs. With some exceptions, fire service personnel and fire protection engineers were excluded because directories already exist for these professionals. Also excluded are investigators engaged principally in studies of propulsion, combustion, and explosion phenomena, because these areas of study are somewhat aside from the main focus of fire research. For purposes of the directory, fire science is taken to be the body of knowledge, art, and skill related to the investigation, analysis, and interpretation of the phenomena of unwanted fires and the evaluation of materials methods, systems, and equipment related to fire safety, prevention, detection, and suppression.

Kuvshinoff, B. W.↗

Safe Emergency Evacuation From Tall Structures

Emergency egress system allows people to be evacuated quickly from tall structures. New emergency system applicable to rescues from fires in tall hotels and other buildings. System consists of basket on slide wire. Basket descends by gravity on sloped slide wire staked to ground.

Stephan, E. S.↗

Space Station propulsion system test bed and control system testing results

The test bed fabricated to demonstrate hydrogen/oxygen propulsion technology readiness for the IOC Space Station application is described and test results are presented. The reliability and safety of the O2/H2 system was demonstrated with blowdowns and thruster firings. The flexibility of the system was demonstrated through the addition of an electrolysis supply module.

Norman, A. M.↗

Enrichments of Anaerobic Selenium Oxyanion Reducers from FGD Wastewater Effluent

Flue gas desulfurization systems (FGD) mitigate air pollutants from coal fired power plants. However, such systems produce wastewater that contains other pollutants such as mercury, arsenic, nitrogen, and selenium that must be removed before the water is released back into the environment. Selenium is of interest because chronic low doses of selenium (ng/L) can cause detrimental ecological consequences. Biological treatment can be utilized to remove selenium from FGD wastewater, but the microorganisms involved in this process and environment within the FGD effluent have not been well studied. This study identifies the microorganisms in selenate-enriched and selenite-enriched FGD effluent that can reduce selenium oxyanions to elemental selenium. Knowing more about these organisms can lead to an eventual optimization in the biological removal of selenium species in these wastewaters.

Sarkar, Preom↗

Evaluation of Machine Learning and Deep Learning Algorithms for Fire Prediction in Southeast Asia

Vegetation fires are prevalent in South/Southeast Asian countries, making fire prediction crucial due to their potential environmental, economic, and social impacts. Accurate predictions of fires facilitate timely interventions, helping to mitigate uncontrolled fires that can lead to biodiversity loss and air quality issues. In this study, we utilize VIIRS satellite-derived fire data alongside six machine learning and deep learning models—Simple Persistence, Multi-Layer Perceptron (MLP), Convolutional Neural Network (CNN), Long Short-Term Memory (LSTM), CNN-LSTM, and ConvLSTM—to determine the most effective fire prediction model, using Root Mean Square Error (RMSE) as the metric. Our results indicate that the CNN model is the most reliable in regions with spatial dependencies, such as Brunei, Indonesia, Malaysia, the Philippines, Timor-Leste, and Thailand. Conversely, the ConvLSTM model excels in countries with complex spatiotemporal dynamics like Laos, Myanmar, and Vietnam. The CNN-LSTM hybrid model also performed well in Cambodia, suggesting a need for a balanced approach in areas requiring both spatial and temporal feature extraction. Furthermore, simpler models like Persistence and MLP showed limitations in capturing dynamic patterns and temporal dependencies. Our findings highlight the importance of evaluating models before implementing any decision support systems (DSS) in fire management. By tailoring models to specific regional fire data, we can enhance prediction accuracy and responsiveness, ultimately improving fire risk management in Southeast Asia and beyond.

Deep learning↗

Fire protection for launch facilities using machine vision fire detection

Fire protection of critical space assets, including launch and fueling facilities and manned flight hardware, demands automatic sensors for continuous monitoring, and in certain high-threat areas, fast-reacting automatic suppression systems. Perhaps the most essential characteristic for these fire detection and suppression systems is high reliability; in other words, fire detectors should alarm only on actual fires and not be falsely activated by extraneous sources. Existing types of fire detectors have been greatly improved in the past decade; however, fundamental limitations of their method of operation leaves open a significant possibility of false alarms and restricts their usefulness. At the Civil Engineering Laboratory at Tyndall Air Force Base in Florida, a new type of fire detector is under development which 'sees' a fire visually, like a human being, and makes a reliable decision based on known visual characteristics of flames. Hardware prototypes of the Machine Vision (MV) Fire Detection System have undergone live fire tests and demonstrated extremely high accuracy in discriminating actual fires from false alarm sources. In fact, this technology promises to virtually eliminate false activations. This detector could be used to monitor fueling facilities, launch towers, clean rooms, and other high-value and high-risk areas. Applications can extend to space station and in-flight shuttle operations as well; fiber optics and remote camera heads enable the system to see around obstructed areas and crew compartments. The capability of the technology to distinguish fires means that fire detection can be provided even during maintenance operations, such as welding.

Schwartz, Douglas B.↗

Development and test of electromechanical actuators for thrust vector control

A road map of milestones toward the goal of a full scale Redesigned Solid Rocket Motor/Flight Support Motor (RSRM/FSM) hot fire test is discussed. These milestones include: component feasibility, full power system demonstration, SSME hot fire tests, and RSRM hot fire tests. The participation of the Marshall Space Flight Center is emphasized.

Weir, Rae A.↗

Space-Based Sensorweb Monitoring of Wildfires in Thailand

We describe efforts to apply sensorweb technologies to the monitoring of forest fires in Thailand. In this approach, satellite data and ground reports are assimilated to assess the current state of the forest system in terms of forest fire risk, active fires, and likely progression of fires and smoke plumes. This current and projected assessment can then be used to actively direct sensors and assets to best acquire further information. This process operates continually with new data updating models of fire activity leading to further sensing and updating of models. As the fire activity is tracked, products such as active fire maps, burn scar severity maps, and alerts are automatically delivered to relevant parties.We describe the current state of the Thailand Fire Sensorweb which utilizes the MODIS-based FIRMS system to track active fires and trigger Earth Observing One / Advanced Land Imager to acquire imagery and produce active fire maps, burn scar severity maps, and alerts. We describe ongoing work to integrate additional sensor sources and generate additional products.

sensorweb↗

Orion MPCV Touchdown Detection Threshold Development and Testing

A robust method of detecting Orion Multi-Purpose Crew Vehicle (MPCV) splashdown is necessary to ensure crew and hardware safety during descent and after touchdown. The proposed method uses a triple redundant system to inhibit Reaction Control System (RCS) thruster firings, detach parachute risers from the vehicle, and transition to the post-landing segment of the Flight Software (FSW). An in-depth trade study was completed to determine optimal characteristics of the touchdown detection method resulting in an algorithm monitoring filtered, lever-arm corrected, 200 Hz Inertial Measurement Unit (IMU) vehicle acceleration magnitude data against a tunable threshold using persistence counter logic. Following the design of the algorithm, high fidelity environment and vehicle simulations, coupled with the actual vehicle FSW, were used to tune the acceleration threshold and persistence counter value to result in adequate performance in detecting touchdown and sufficient safety margin against early detection while descending under parachutes. An analytical approach including Kriging and adaptive sampling allowed for a sufficient number of finite element analysis (FEA) impact simulations to be completed using minimal computation time. The combination of a persistence counter of 10 and an acceleration threshold of approximately 57.3 ft/s2 resulted in an impact performance factor of safety (FOS) of 1.0 and a safety FOS of approximately 2.6 for touchdown declaration. An RCS termination acceleration threshold of approximately 53.1 ft/s(exp)2 with a persistence counter of 10 resulted in an increased impact performance FOS of 1.2 at the expense of a lowered under-parachutes safety factor of 2.2. The resulting tuned algorithm was then tested on data from eight Capsule Parachute Assembly System (CPAS) flight tests, showing an experimental minimum safety FOS of 6.1. The formulated touchdown detection algorithm will be flown on the Orion MPCV FSW during the Exploration Flight Test 1 (EFT-1) mission in the second half of 2014.

Daum, Jared↗

Design and implementation of a multi-sensor robot system for printed circuit board insertion

The design and implementation of a robot system equipped with multiple sensors are described. The robotic assembly system couples the task sequence of the robot with information from different sensors, enabling the system to handle uncertainties encountered during task execution. The target task involves the insertion of a printed circuit board into a card cage. The sensors used are an overhead three-dimensional vision system, a fingertip cross-fire sensor, and a 6-DOF force/torque sensor. The vision system is used to locate the printed circuit boards and the insertion slots. Information provided by the cross-fire sensor is used to complement the information from the vision system in order to obtain a proper grasping location on the printed circuit board. A fuzzy-logic-based system is used to interpret the forces and torques generated by the force/torque sensor during the insertion process. The repeated success of this assembly task over many experimental trials verifies the modeling and controller assumptions.

Sood, Deepak↗

Bench-Scale Development of a Hybrid Membrane-Absorption CO 2 Capture Process

This final technical report describes work conducted for the Department of Energy (DOE) on the development of a bench-scale hybrid membrane-absorption carbon dioxide (CO 2 ) capture system for coal-fired power plant applications (Cooperative Agreement number DE-FE0013118). The work was conducted by Membrane Technology and Research, Inc. (MTR) with major support from the University of Texas at Austin (UT Austin) from April 1, 2013 through September 30, 2018. The overall goal of this project was to evaluate two variations of a hybrid membrane-absorption capture system combining the MTR air-swept Polaris TM membrane technology, which enriches flue gas to ~20% CO 2 , with UT Austin’s absorption-based advanced flash stripper (AFS) using piperazine (PZ), to determine the superior hybrid variant and to assess the potential of hybrid capture systems to achieve a lower cost-of-capture, compared to NETL’s reference amine-based capture plant. This project included the evaluation, development and testing of a hybrid membrane-absorption CO 2 capture system for coal-fired power plant applications using the MTR high-gas-flow, lowpressure- drop membrane contactor. The ability of the membrane contactor to enrich coal-fired flue gas from its normal content of ~13% CO 2 into a smaller volume of gas containing 20-25% CO 2 – with minimal energy input – could reduce the cost of the final concentration process, regardless of whether it is absorption, adsorption, cryogenic, or membrane-based. In this project, we are evaluating the feasibility of a hybrid system combining the MTR sweep membrane technology with the UT Austin piperazine-based advanced flash stripper (PZAS) capture system.

99 GENERAL AND MISCELLANEOUS↗

Bench scale development of a hybrid membrane-absorption CO 2 capture process (Final Report)

This final technical report describes work conducted for the Department of Energy (DOE) on the development of a bench-scale hybrid membrane-absorption carbon dioxide (CO 2 ) capture system for coal-fired power plant applications (Cooperative Agreement number DE-FE0013118). The work was conducted by Membrane Technology and Research, Inc. (MTR) with major support from the University of Texas at Austin (UT Austin) from April 1, 2013 through September 30, 2018. The overall goal of this project was to evaluate two variations of a hybrid membrane-absorption capture system combining the MTR air-swept PolarisTM membrane technology, which enriches flue gas to ~20% CO 2 , with UT Austin’s absorption-based advanced flash stripper (AFS) using piperazine (PZ), to determine the superior hybrid variant and to assess the potential of hybrid capture systems to achieve a lower cost-of-capture, compared to NETL’s reference amine-based capture plant. This project included the evaluation, development and testing of a hybrid membrane-absorption CO 2 capture system for coal-fired power plant applications using the MTR high-gas-flow, low-pressure-drop membrane contactor. The ability of the membrane contactor to enrich coal-fired flue gas from its normal content of ~13% CO 2 into a smaller volume of gas containing 20-25% CO 2 – with minimal energy input – could reduce the cost of the final concentration process, regardless of whether it is absorption, adsorption, cryogenic, or membrane-based. In this project, we are evaluating the feasibility of a hybrid system combining the MTR sweep membrane technology with the UT Austin piperazine-based advanced flash stripper (PZAS) capture system.

20 FOSSIL-FUELED POWER PLANTS↗

Incorporating an Interactive Fire Plume-Rise Model in the DOE's Energy Exascale Earth System Model Version 1 (E3SMv1) and Examining Aerosol Radiative Effect

The vertical distribution of biomass burning aerosol (BBA) is important in regulating their impacts on weather and climate. The plume-rise process affects the injection height of BBA and interacts with the air parcel lifting and cloud processes. However, these processes are not represented in most global climate models. In this study, we replaced the fixed vertical profiles of monthly BBA emissions in the Department of Energy's Energy Exascale Earth System Model version 1 (E3SMv1) with an interactive fire plume-rise model. The vertical distribution of BBA emissions was calculated as a function of ambient thermodynamic conditions from the host E3SMv1, with distributions of fire sizes and sensible heat fluxes derived from the observations. The maximum fire radiative power (FRP) technique was used to determine the fire size. Scaling-FRP technique is used to calculate the wildfire heat release. Daily BBA emission, superimposed with a fire diurnal cycle retrieved from the satellite observation, was included in model simulations. The model shows improved agreement with satellite retrievals and in situ measurement during the National Oceanic and Atmospheric Administration Wildfire Experiment for Cloud chemistry, Aerosol absorption, and Nitrogen campaign. The model-observation comparison demonstrates the importance of the plume-rise model and fire diurnal cycle assumption in determining the BBA fields. We also find that E3SMv1 with new features produces a larger carbonaceous aerosol burden, leading to 0.13 W m –2 warming at the top of atmosphere compared to the default E3SMv1. This highlights the importance of accurately representing the BBA injection height and indicates a no-linear nature in the BBA-induced radiative effect.

54 ENVIRONMENTAL SCIENCES↗