Free Energy Dependencies for Interfacial Electron Transfer from Tin-Doped Indium Oxide (ITO) to Molecular Photoredox Catalysts

John B. Goodenough proposed that interfacial electron transfer kinetics from main group metal oxides should be fundamentally different from that of transition metal oxides, an expectation that has not been widely tested. Herein, the kinetics for interfacial electron transfer from mesoporous transparent conductive oxide Tin-doped Indium Oxide (ITO) to four photoredox catalysts (PCs) were characterized in acetonitrile electrolytes. The photocatalysts had the form: [Ru(4,4ʹ-R 2 -2,2′-bipyridine) 2 (4,4ʹ-(PO 3 H 2 ) 2 -2,2′-bipyridine)] 2+ , where R was H, methoxy, tert -butyl, and Br. The impact of the surface binding group was characterized with [Ru(2,2′-bipyridine) 2 (4,4ʹ-(CO 2 H) 2 -bpy)] 2+ . The interfacial electron transfer reaction ITO(e − )∣PC + → ITO∣PC was quantified by nanosecond absorption spectroscopy as a function of the applied potential (and hence ‒Δ G °). Specific conditions of applied potential were identified where the kinetics were sensitive to the incident irradiance. A layer-by-layer method was used to insert ionic methylene bridge(s) between the PC and the oxide surface. Marcus-Gerischer analysis of the kinetic data indicates non-adiabatic interfacial electron transfer with total reorganization energies that increase when bridges were placed between the photocatalyst and the ITO surface.

Bangle, Rachel E.↗

ELECTRON COOLING USING A PULSED AND DITHERING BEAM FROM AN ELECTROSTATIC ELECTRON COOLER

Electron cooling continues to be an invaluable technique to reduce and maintain the emittance in hadron storage rings such as the EIC and EICC where stochastic cooling is inefficient and radiative cooling is negligible. Extending the energy range of electron coolers beyond what is feasible with the conventional, electrostatic approach necessitates the use of RF fields for acceleration and, thus, a bunched electron beam. To experimentally investigate how the relative time structure of the two beams affects the cooling properties, we have set up a pulsed-beam cooling device by adding a synchronized pulsing circuit to the conventional electron source of the CSRm cooler at Institute of Modern Physics. Using both constant and modulated synchronization between electron pulses and ion bunches, we have measured the effects of the electron bunch length and longitudinal ion focusing strength on the temporal evolution of the longitudinal and transverse ion beam profile and demonstrated the detrimental effect of timing jitter as predicted by space-charge theory and simulations. Our experiment suggests a need for further investigations of specific aspects of bunched cooling such as synchro-betatron coupling and phase dithering effects when using short electron bunches to cool longer ion bunches. However, given the comparatively long IBS lifetime of higher-energy proton storage rings like the EIC, slow dithering could potentially provide an option to save cost on the electron cooler linac.

Wang, Haipeng↗

Evaluation of accuracy and resolution of the electron beam profile scanner at the Fermilab Main Injector

The objective of this work is to assess the accuracy of measurements made by the Electron Beam Profile Scanner (EBPS), which captures the trajectory of an electron beam with and without a proton beam present. The proton beam induces deflection in the electron beam, which is influenced by proton charges.For high-resolution images, the probe beam needs to be of high intensity, small diameter, and small divergence, evaluated using a YAG screen and an optical transition radiation (OTR) screen. Additionally, the point spread function (PSF) will be calculated to characterize the optical system's properties using ZEMAX software. The capabilities of the Hamamatsu Charge-Injection Device (CID) camera and Kimball Physics electron gun (e-gun) will be considered for accuracy.

Mwaniki, Matilda [IIT, Chicago; Fermilab]↗

Superconducting RF Gun with High Current and the Capability to Generate Polarized Electron Beams

High-current low-emittance CW electron beams are indispensable for nuclear and high-energy physics fixed target and collider experiments, cooling high energy hadron beams, generating CW beams of monoenergetic X-rays (in FELs) and gamma-rays (in Compton sources). Polarization of electrons in these beams provides extra value by opening a new set of observables and frequently improving the data quality. We report on the upgrade of the unique and fully functional CW SRF 1.25 MeV SRF gun, built as part of the Coherent electron Cooling (CeC) project, which has demonstrated sustained CW operation with CsK2Sb photocathodes generating electron bunches with record-low transverse emittances and record-high bunch charge exceeding 10 nC. We propose to extend the capabilities of this system to high average current of 100 milliampere in two steps: increasing the current 30-fold at each step with the goal to demonstrate reliable long-term operation of the high-current low-emittance CW SRF guns. We also propose to test polarized GaAs photocathodes in the ultra-high vacuum (UHV) environment of the SRF gun, which has never been successfully demonstrated in RF accelerators.

43 PARTICLE ACCELERATORS↗

Electron Cloud Simulations for the Electron-Ion Collider in Brookhaven National Laboratory

For high-intensity circular accelerators and storage rings, if the secondary electron emission yield (SEY) of the vacuum chamber surfaces is high, an EC (Electron Cloud) could build up with the passage of the circulating beam. The presence of EC can strongly affect the beam quality, such as transverse instabilities, transverse emittance growth, and beam loss. Furthermore, the heat load from EC can exceed the available cryogenic capability. For the RHIC superconducting (SC) arc magnets, to be used for the hadron storage ring of the Electron-Ion Collider (EIC), the dynamic heat load budget is 0.5 W/m to the 4.5 K stainless steel beam pipe. This can limit the maximum beam bunches or intensity of the EIC, hence diminishing the luminosity provided by the EIC. The EC has affected the beam instability and significantly contributed to cryogenic heat load in the Large Hadron Collider (LHC). Positron storage rings for which ECs have been a critical factor in the design and performance include KEKB in Japan and EC buildup remains one of the concerns for future high-intensity accelerators design. EC considerations have driven the SuperKEKB collider design and the positron damping ring for the proposed International Linear Collider (ILC). The LHC luminosity upgrade is contingent on reducing the bunch spacing to 25 ns; at this bunch spacing, severe EC buildup has been observed. The success of the upgrade is likely contingent on limiting EC buildup. To study the EC heat load, we did some EC simulations with PyECLOUD code for the dipole, quadrupole, sextupole magnets, and the warm (drift) section of the EIC hadron storage ring. PyECLOUD is an EC simulation code developed by CERN. The code has been validated and used to study EC in the LHC, SPS, and PS. To eliminate EC buildup, the sources of electrons must be minimized. First, we will reduce the production of electrons due to residual gas ionization by specifying the maximum gas density, which requires a vacuum chamber with low electron-stimulated desorption (ESD) yields and a sufficient (preferably distributed) pumping speed. Second, we should reduce the secondary electrons with a lower secondary electron yield (SEY) material.

43 PARTICLE ACCELERATORS↗

Strain mapping at nanometer resolution using advanced nano-beam electron diffraction

In this work, we report on the development of a nanometer scale strain mapping technique by means of scanning nano-beam electron diffraction. Only recently possible due to fast acquisition with a direct electron detector, this technique allows for strain mapping with a high precision of 0.1% at a lateral resolution of 1 nm for a large field of view reaching up to 1 μm. We demonstrate its application to a technologically relevant strain-engineered GaAs/GaAsP hetero-structure and show that the method can even be applied to highly defected regions with substantial changes in local crystal orientation. Strain maps derived from atomically resolved scanning transmission electron microscopy images were used to validate the accuracy, precision and resolution of this versatile technique.

36 MATERIALS SCIENCE↗

Anomalous Electron Spectrum and Its Relation to Peak Structure of Electron Scattering Rate in Cuprate Superconductors

The recent discovery of a direct link between the sharp peak in the electron quasiparticle scattering rate of cuprate superconductors and the well-known peak–dip–hump structure in the electron quasiparticle excitation spectrum is calling for an explanation. Within the framework of the kinetic-energy-driven superconducting mechanism, the complicated line-shape in the electron quasiparticle excitation spectrum of cuprate superconductors is investigated. It is shown that the interaction between electrons by the exchange of spin excitations generates a notable peak structure in the electron quasiparticle scattering rate around the antinodal and nodal regions. However, this peak structure disappears at the hot spots, which leads to that the striking peak–dip–hump structure is developed around the antinodal and nodal regions, and vanishes at the hot spots. The theory also confirms that the sharp peak observed in the electron quasiparticle scattering rate is directly responsible for the remarkable peak–dip–hump structure in the electron quasiparticle excitation spectrum of cuprate superconductors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Microsecond Electron Beam Source with Electron Energy Up to 400 Kev and Plasma Anode

A new high-power source of electrons with plasma anode for producing high-current microsecond electron beams with electron energy up to 400 keV has been developed, manufactured, and put in operation. To increase the cross section and pulse current duration of the beam, a multipoint explosive emission cathode is used in the electron beam source, and the beam is formed in an applied external guiding magnetic field. The Marx generator with vacuum insulation is used as a high-voltage source. Electron beams with electron energy up to 300–400 keV, current of 5–15 kA, duration of 1.5–3 μs, energy up to 4 kJ, and cross section up to 150 cm{sup 2} have been produced. The operating modes of the electron beam source are realized in which the applied voltage is influenced weakly on the current. The possibility of source application for melting of metal surfaces is demonstrated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Transverse profile of the electron beam for the RHIC electron lenses

To compensate for the beam-beam effects from the proton-proton interactions at the two interaction points IP6 and IP8 in the Relativistic Heavy Ion Collider (RHIC), we are constructing two electron lenses (e-lenses) that we plan to install in the interaction region IR10. Before installing them, the electron gun, collector, instrumentation were tested and the electron beam properties were qualified on an electron lens test bench. We will present the test results and discuss our measurement of the electron beam current and of the electron gun perveance. We achieved a maximum current of 1 A with 5 kV energy for both the pulsed- and the DC-beam (which is a long turn-by-turn pulse beam). We measured beam transverse profiles with an Yttrium Aluminum Garnet (YAG) screen and pinhole detector, and compared those to simulated beam profiles. Measurements of the pulsed electron beam stability were obtained by measuring the modulator voltage.

43 PARTICLE ACCELERATORS↗

Generation and characterization of magnetized electron beam from a DC high voltage photogun for electron beam cooling application

One of the most challenging requirements for the proposed Electron-Ion Collider is the strong cooling of the proton beam, which is key to achieving the collider’s desired luminosity of order 10 33 -10 34 cm -2 s -1 . Magnetized bunched-beam electron cooling could be a means to achieve the required high luminosity, where strong cooling is accomplished inside a cooling solenoid where the ions co-propagate with an electron beam generated from a source immersed in a magnetic field. To increase the cooling efficiency, a bunched electron beam with high bunch charge and high repetition rate is required. This work describes the production and characterization of magnetized electron beam using a compact 300 kV DC high voltage photogun and bi-alkali antimonide photocathode. Beam magnetization was studied using a diagnostic beamline that includes viewer screens for measuring the shearing angle of the electron beamlet passing through a narrow upstream slit. Simulations and corresponding measurements of beam magnetization are presented as a function of laser spot size and magnetic field strength. Correlated beam emittance with magnetic field (0–0.15 T) at the photocathode was measured for various laser spot sizes. Measurements of photocathode lifetime were carried out at different magnetized electron beam currents up to 28 mA, and bunch charge up to 0.7 nC (not simultaneously).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Resolving the Electron Plume within a Scanning Electron Microscope

Scanning electron microscopy (SEM), a century-old technique, is today a ubiquitous method of imaging the surface of nanostructures. However, most SEM detectors simply count the number of secondary electrons from a material of interest, and thereby overlook the rich material information contained within them. Here, by simple modifications to a standard SEM tool, we resolve the momentum and energy information on secondary electrons by directly imaging the electron plume generated by the electron beam of the SEM. Leveraging these spectroscopic imaging capabilities, our technique is able to image lateral electric fields across a prototypical silicon p–n junctions and to distinguish differently doped regions, even when buried beyond depths typically accessible by SEM. Intriguingly, the subsurface sensitivity of this technique reveals unexpectedly strong surface band bending within nominally passivated semiconductor structures, providing useful insights for complex layered component designs, in which interfacial dynamics dictate device operation. Further, these capabilities for noninvasive, multimodal probing of complicated electronic components are crucial in today’s electronic manufacturing but is largely inaccessible even with sophisticated techniques. These results show that seemingly simple SEM can be extended to probe complex and useful material properties.

36 MATERIALS SCIENCE↗

Electronic properties of bimetallic metal–organic frameworks (MOFs): Tailoring the density of electronic states through MOF modularity

The development of porous well-defined hybrid materials (e.g., metal-organic frameworks or MOFs) will add a new dimension to a wide number of applications ranging from supercapacitors and electrodes to 'smart' membranes and thermoelectrics. From this perspective, the understanding and tailoring of the electronic properties of MOFs are key fundamental challenges that could unlock the full potential of these materials. In this work, we focused on the fundamental insights responsible for the electronic properties of three distinct classes of bimetallic systems, M x-y M' y -MOFs, M x M' y - MOFs, and M x (ligand-M' y )-MOFs, in which the second metal (M') incorporation occurs through (i) metal (M) replacement in the framework nodes (type I), (ii) metal node extension (type II), and (iii) metal coordination to the organic ligand (type III), respectively. We employed microwave conductivity, X-ray photoelectron spectroscopy, diffuse reflectance spectroscopy, powder X-ray diffraction, inductively coupled plasma atomic emission spectroscopy, pressed-pellet conductivity, and theoretical modeling to shed light on the key factors responsible for the tunability of MOF electronic structures. Experimental prescreening of MOFs was performed based on changes in the density of electronic states near the Fermi edge, which was used as a starting point for further selection of suitable MOFs. As a result, we demonstrated that the tailoring of MOF electronic properties could be performed as a function of metal node engineering, framework topology, and/or the presence of unsaturated metal sites while preserving framework porosity and structural integrity. Finally, these studies unveil the possible pathways for transforming the electronic properties of MOFs from insulating to semiconducting, as well as provide a blueprint for the development of hybrid porous materials with desirable electronic structures.

36 MATERIALS SCIENCE↗

Screening of remote charge scattering sites from the oxide/silicon interface of strained Si two-dimensional electron gases by an intermediate tunable shielding electron layer

We report the strong screening of the remote charge scattering sites from the oxide/semiconductor interface of buried enhancement-mode undoped Si two-dimensional electron gases (2DEGs), by introducing a tunable shielding electron layer between the 2DEG and the scattering sites. When a high density of electrons in the buried silicon quantum well exists, the tunneling of electrons from the buried layer to the surface quantum well can lead to the formation of a nearly immobile surface electron layer. The screening of the remote charges at the interface by this newly formed surface electron layer results in an increase in the mobility of the buried 2DEG. Furthermore, a significant decrease in the minimum mobile electron density of the 2DEG occurs as well. Together, these effects can reduce the increased detrimental effect of interface charges as the setback distance for the 2DEG to the surface is reduced for improved lateral confinement by top gates.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Determination of the ReA Electron Beam Ion Trap electron beam radius and current density with an X-ray pinhole camera

The Electron Beam Ion Trap (EBIT) of the National Superconducting Cyclotron Laboratory at Michigan State University is used as a charge booster and injector for the currently commissioned rare isotope re-accelerator facility ReA. This EBIT charge breeder is equipped with a unique superconducting magnet configuration, a combination of a solenoid and a pair of Helmholtz coils, allowing for a direct observation of the ion cloud while maintaining the advantages of a long ion trapping region. The current density of its electron beam is a key factor for efficient capture and fast charge breeding of continuously injected, short-lived isotope beams. It depends on the radius of the magnetically compressed electron beam. This radius is measured by imaging the highly charged ion cloud trapped within the electron beam with a pinhole camera, which is sensitive to X-rays emitted by the ions with photon energies between 2 keV and 10 keV. The 80%-radius of a cylindrical 800 mA electron beam with an energy of 15 keV is determined to be r{sub 80%}=(212±19)μm in a 4 T magnetic field. From this, a current density of j = (454 ± 83)A/cm{sup 2} is derived. These results are in good agreement with electron beam trajectory simulations performed with TriComp and serve as a test for future electron gun design developments.

43 PARTICLE ACCELERATORS↗

Detection of electron energy distribution function anisotropy in a magnetized electron cyclotron resonance plasma by using a directional Langmuir probe

Anisotropy in the electron energy distribution function (EEDF) in an electron cyclotron resonance plasma with magnetized electrons and weakly magnetized ions is experimentally investigated using a directional Langmuir probe. Under an assumption of independent EEDFs in the directions parallel and perpendicular to the magnetic field, the directional variation of the EEDF is evaluated. In the measured EEDFs, a significantly large population density of electrons with energies larger than 30 eV is found in one of the cross-field directions depending on the magnetic field direction. With the aid of an electron trajectory calculation, it is suggested that the observed anisotropic electrons originate from the EEDF anisotropy and the cross-field electron drift.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electronic structure and thermoelectric properties of half-Heusler compounds with eight electron valence count—KScX (X = C and Ge)

Electronic band structure and structural properties of two representative half-Heusler (HH) compounds with 8 electron valence count (VC), KScC and KScGe, have been studied using first principles methods within density functional theory and generalized gradient approximation. These systems differ from the well studied class of HH compounds like ZrNiSn and ZrCoSb which have VC = 18 because of the absence of d electrons of the transition metal atoms Ni and Co. Electronic transport properties such as Seebeck coefficient (S), electrical conductivity (σ), electronic thermal conductivity (κ{sub e}) (the latter two scaled by electronic relaxation time), and the power factor (S{sup 2}σ) have been calculated using semi-classical Boltzmann transport theory within constant relaxation time approximation. Both the compounds are direct band gap semiconductors with band extrema at the X point. Their electronic structures show a mixture of heavy and light bands near the valance band maximum and highly anisotropic conduction and valence bands near the band extrema, desirable features of good thermoelectric. Optimal p- or n-type doping concentrations have been estimated based on thermopower and maximum power factors. The optimum room temperature values of S are ∼1.5 times larger than that of the best room temperature thermoelectric Bi{sub 2}Te{sub 3}. We also discuss the impact of the band structure on deviations from Weidemann-Franz law as one tunes the chemical potential across the band gap.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization of electron spin polarization from positive electron affinity GaAs photocathodes

Negative Electron Affinity (NEA) GaAs photocathodes are widely used to generate spin-polarized electron beams, typically achieving Electron Spin Polarizations (ESPs) in the range of 35%–40%. However, when operated in a Positive Electron Affinity (PEA) state, where a potential barrier inhibits low-energy electrons from escaping into vacuum, measured ESPs can exceed 50%. This effect can occur naturally during photocathode operation, as the NEA surface activation layers can degrade easily over time, increasing the electron affinity. In this work, we investigate and characterize the behavior of enhanced ESPs under PEA conditions. We present experimental measurements of ESP using a retarding-field Mott polarimeter on GaAs photocathodes with controlled and varying electron affinities. These results are complemented by theoretical explanations considering the material band structure, the light excitation profile, and spin depolarization mechanisms.

Electronic band structure↗

Multislice Electron Tomography Using Four-Dimensional Scanning Transmission Electron Microscopy

Electron tomography offers useful three-dimensional (3D) structural information, which cannot be observed by two-dimensional imaging. By combining annular dark-field scanning transmission electron microscopy (ADF STEM) with aberration correction, the resolution of electron tomography has reached atomic resolution. However, tomography based on ADF STEM inherently suffers from several issues, including a high electron-dose requirement, poor contrast for light elements, and artifacts from image-contrast nonlinearity. Here, we develop an alternative method called multislice electron tomography (MSET) based on four-dimensional STEM tilt series. In this study, our simulations show that multislice-based 3D reconstruction can effectively reduce undesirable reconstruction artifacts from the nonlinear contrast, allowing precise determination of atomic structures with improved sensitivity for low-Z elements, at considerably low electron-dose conditions. We expect that the MSET method can be applied to a wide variety of materials, including radiation-sensitive samples and materials containing light elements whose 3D atomic structures have never been fully elucidated due to electron-dose limitations or nonlinear imaging contrast.

74 ATOMIC AND MOLECULAR PHYSICS↗