First Characterization of Coherent Optical Vortices from Harmonic Undulator Radiation
Abstract Not Provided
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract Not Provided
Not Available
Abstract not provided.
The temperature of the LCLS undulators has not been controlled during storage. The effects of the temperature excursions are documented in this note. After a number of LCLS undulators were tuned, fiducialized, and placed in storage anticipating their use, a test was made to ensure that their properties had not changed. The test revealed, however, that indeed the undulators had changed. Detailed study of this problem followed. We now believe that the gap of the undulators changes permanently when the undulators go through temperature excursions. We have tested the other possible cause, transportation, and do not see gap changes. In this note, we document how the undulators have changed since they were originally tuned. The undulators were tuned and fiducialized in the Magnetic Measurement Facility (MMF). Afterward, many of them (approximately 18) were taken to building 750 for storage during summer and fall 2007. Building 750 had no temperature control. The undulator temperatures went from 20 C, used for tuning, down to approximately 11 C during the winter. In January 2008, three of the undulators were brought back to the MMF for a check. All three undulators showed similar changes. Trajectories, phases, and most undulator properties stayed the same, but the fiducialization (beam axis position relative to tooling balls on the undulator) had changed. Further investigation showed that the undulator gap was altered in a periodic way along the magnetic axis with a net average gap change causing the fiducialization change. A new storage location in building 33 was found and future undulators were placed there. A failure in the temperature control, however, caused the undulators to get too hot. Again the gap changed, but with a different periodic pattern. This note documents the measured changes in the undulators. In particular, it shows the detailed history of undulator 39 which went through both negative and positive temperature excursions.
A request for studying the spectral performance of in-vacuum undulators (IVUs) for the APS storage ring was recently put forward. In-vacuum undulators are prevalent at other synchrotron radiation facilities such as the ESRF and the Spring-8. However, they never made it into the arsenal of undulators at the APS because the brilliance tuning curves were sufficiently wide due to the fact that the undulator minimum gap could be set as low as 10.5 mm. For sector 3, which in the past used a narrow-gap vacuum chamber, the minimum undulator pole gap was allowed to be set as low as 8.5 mm, providing contiguous tuning curves between the first and third harmonic radiation for a 2.7-cm-period device. (Subsequently, the narrow-gap vacuum chamber was removed and replaced with a standard vacuum chamber, which allows a minimum gap of 10.5 mm.) For sector 4, which currently holds the only narrow-gap vacuum chamber at the APS, the minimum gap is 9.5 mm. In this sector, a permanent magnet hybrid undulator with SmCo magnets is used instead of NdFeB magnets because of their higher radiation resistance and their better protection against radiation-induced demagnetization of the magnets. In the realm of looking to the future, new concepts and technologies are being revisited. Most notable is the superconducting undulator (SCU) technology, which provides the ultimate highest magnetic field of any technology and design. The SCU program has been ongoing at the APS for several years and substantial progress has been made.3,4 However, the in-vacuum undulators may bridge some of the user demands, and it is therefore worthwhile revisiting their potential at the APS. In this work, the following were assumed or required: (1) the smallest in-vacuum beam-stay-clear gap is 5.0 mm, (2) a beam-liner of 2 x 0.060 mm, which increases the pole gap by the same amount, (3) both NdFeB and SmCo magnets shall be studied, even though SmCo magnets are the preferred choice for very small gaps, (4) compare the in-vacuum undulators with superconducting NbTi undulators with a wall thickness/space of 2 x 1.0 mm, and (5) all undulators will have an effective magnetic length of 2.4 m. Three short undulator period lengths were chosen somewhat arbitrary and studied. We will compare the performance of undulators with period lengths of 2.5 cm and 2.0 cm to one with a 1.6-cm period, which is the chosen period length of the first designed and tested short-length SCU for the APS. Additionally, we will make comparisons with the undulator A, which has a period length of 3.3 cm.
The on- and off-axis magnetic fields for infinitely long, helical undulators were analyzed for linear and nonlinear poles. An analytical expression of the on-axis field for linear poles was derived in terms of coil current density, undulator period length, and coil dimensions. The derived expression showed that, when the undulator dimensions were scaled according to the period ratios, the on-axis fields were proportional to the periods, which is in agreement with calculations of model undulators. For undulators with nonlinear steel poles, when the undulator dimensions were scaled, the field distributions remained unchanged for a constant value of (current density x period). It was also shown that, for two scaled undulators, one with linear and one with nonlinear poles, the off-axis field components, normalized to the respective on-axis fields, had the same field distributions near the axis within the calculation errors. This implies that the derived normalized off-axis field for linear poles may be used for beam dynamic analysis in the fields of undulators with nonlinear poles within the beam chamber. Achievable on-axis fields were calculated for short-period undulators with parameters close to those for the proposed International Linear Collider (ILC) positron production undulators. The required undulator parameters for the ILC appear to be achievable depending on the Nb{sub 3}Sn superconductor packing factor in the coil and on how close the chosen operating current is to the critical current.
The laser heater undulator for the LCLS requires different tuning techniques than the main undulators. It is a pure permanent magnet (PPM) undulator, rather than the hybrid design of the main undulators. The PPM design allows analytic calculation of the undulator fields. The calculations let errors be introduced and correction techniques be derived. This note describes how the undulator was modelled, and the methods which were found to correct potential errors in the undulator. The laser heater undulator for the LCLS is a pure permanent magnet device requiring different tuning techniques than the main undulators. In this note, the laser heater undulator is modelled and tuning techniques to compensate various errors are derived.
A tuning method for hard x-ray free electron lasers is presented which combines electron-beam-based alignment (EBBA) with undulator radiation spectrum analysis. This method is conducive to achieving a dispersion-free orbit, finding the undulator field center, and determining the accurate value of the gap distance for the operating undulator K for each undulator segment, and it proves to be highly reliable and robust for free electron laser lasing with variable-gap undulators. The effect of the natural focusing of the undulator on the EBBA is confirmed with measurements and a theoretical analysis. The tilt of an undulator segment subject to ground movement introduces an undulator field change which the electron beam interacts with and can be corrected by K tuning to find a precise compensating gap distance. Lattice matching with a wire-scanner-based Twiss parameter measurement along the undulator line enables the EBBA reference orbit to coincide with the e-beam distribution.
This note details the magnetic measurements and the magnetic center fiducializations that were performed on all of the thirty-six LCLS undulator quadrupoles. Temperature rise, standardization reproducibility, vacuum chamber effects and magnetic center reproducibility measurements are also presented. The Linac Coherent Light Source (LCLS) undulator beam line has 33 girders, each with a LCLS undulator quadrupole which focuses and steers the beam through the beam line. Each quadrupole has main quadrupole coils, as well as separate horizontal and vertical trim coils. Thirty-six quadrupoles, thirty-three installed and three spares were, manufactured for the LCLS undulator system and all were measured to confirm that they met requirement specifications for integrated gradient, harmonics and for magnetic center shifts after current changes. The horizontal and vertical dipole trims of each quadrupole were similarly characterized. Each quadrupole was also fiducialized to its magnetic center. All characterizing measurements on the undulator quads were performed with their mirror plates on and after a standardization of three cycles from -6 to +6 to -6 amps. Since the undulator quadrupoles could be used as a focusing or defocusing magnet depending on their location, all quadrupoles were characterized as focusing and as defocusing quadrupoles. A subset of the undulator quadrupoles were used to verify that the undulator quadrupole design met specifications for temperature rise, standardization reproducibility and magnetic center reproducibility after splitting. The effects of the mirror plates on the undulator quadrupoles were also measured.
The development of undulator technologies capable of generating sub-cm undulator periods is assuming an increasing importance in X-ray free electron laser (FEL) applications. Indeed, such devices jointly with the high brightness electron beams already demonstrated at operating facilities would allow for lower energy, more compact electron linacs with a beneficial impact on the size and cost of X-ray FEL facilities. A novel design super-conducting undulator is being developed at the Lawrence Berkeley National Laboratory (LBNL) with the potential of sub-cm periods with reasonably large undulator parameter and gap. The potential and capability of such undulator technology need to be experimentally demonstrated. In this paper, the possibility of constructing an infrared FEL by combining the new undulator with the high brightness beam from the APEX injector facility at LBNL is investigated. Calculations show that the resulting FEL, when operated in self-amplified-spontaneous-emission mode, is expected to deliver a saturated power of almost a MW within a ~4m undulator length, in a single-spike of coherent radiation at ~2μm wavelength. It will be also shown that the small-period of the undulator associated with the relatively low energy of the APEX beam, forces the FEL to operate in a regime with unusual and interesting characteristics. The alternative option of laser seeding the FEL is also briefly examined, showing the potential to reduce the saturation length even further.
The LCLS reference undulator has been measured 22 times during the course of undulator tuning. These measurements provide estimates of various statistical errors. This note gives a summary of the reference undulator measurements and it provides estimates of the undulator tuning errors. We measured the reference undulator many times during the tuning of the LCLS undulators. These data sets give estimates of the random errors in the tuned undulators. The measured trajectories in the reference undulator are stable and straight to within {+-}2 {micro}m. Changes in the phase errors are less than {+-}2 deg between data sets. The phase advance in the cell varies by less than {+-}2 deg between data sets. The rms variation between data sets of the first integral of B{sub x} is 9.98 {micro}Tm, and the rms variation of the second integral of B{sub x} is 17.4 {micro}Tm{sup 2}. The rms variation of the first integral of B{sub y} is 6.65 {micro}Tm, and the rms variation of the second integral of B{sub y} is 12.3 {micro}Tm{sup 2}. The rms variation of the x-position of the fiducialized beam axis is 35 {micro}m in the final production run This corresponds to an rms uncertainty in the K value of {Delta}K/K = 2.7 x 10{sup -5}. The rms variation of the y-position of the fiducialized beam axis is 4 {micro}m in the final production run.
Beam Finder Wire (BFW) devices will be installed at each break in the Undulator magnet line. These devices will scan small wires across the beam causing some electrons to lose energy through bremsstrahlung. The degraded electrons are subsequently detected downstream of a set of vertical dipole magnets after they pass through the vacuum chamber. This signal can then be used to accurately determine the beam position with respect to the BFW wire. The choice of the wire diameter, scan speed, and operating parameters, depends on the trade-off between the signal size and the radiation damage to the undulator magnets. In this note I estimate the rate of undulator magnet damage that results from scanning as a function of, wire size, scan speed, and average beam current. A separate analysis of the signal size was carried out by Wu. The damage estimate is primarily based on two sources: the first, Fasso, is used to estimate the amount of radiation generated and then absorbed by the magnets; the second, Alderman et. al., is used to estimate the amount of damage the magnet undergoes as a result of the absorbed radiation. Fasso performed a detailed calculation of the radiation, including neutron fluence, that results from a the electron beam passing through a 100 micron diamond foil inserted just in front of the undulator line. Fasso discussed the signficance of various types of radiation and stated that photoneutrons probably play a major role. The estimate in this paper assumes the neutron fluence is the only significant cause of radiation-induced demagnetization. The specific results I use from Fasso's paper are reproduced here in Figure 1, which shows the radial distribution of the integrated neutron fluence per day in the undulator magnets, and Figure 2, which shows the absorbed radiation dose all along the undulator line. In the longitudinal dimension, Fasso's calculation, (see Figure 2), shows that the radiation dose is widely distributed all along the undulator line, but is highest around 70 m from the front of the undulator line where the foil is. At the 70 m point, for the purpose of calculating the demagnetization, I chose a conservative estimate for the effective neutron flux of 1.0 x 10{sup 13} n/cm{sup 2}/day. As can be seen in Figure 1, this choice is representative of the flux nearest the beam where it is the highest. A less conservative estimate, but perhaps more accurate, estimate of the effective flux, would be the average flux in the magnet block, which is roughly one half as much.
Automation of the LCLS undulator tuning offers many advantages to the project. Automation can make a substantial reduction in the amount of time the tuning takes. Undulator tuning is fairly complex and automation can make the final tuning less dependent on the skill of the operator. Also, algorithms are fixed and can be scrutinized and reviewed, as opposed to an individual doing the tuning by hand. This note presents algorithms implemented in a computer program written for LCLS undulator tuning. The LCLS undulators must meet the following specifications. The maximum trajectory walkoff must be less than 5 {micro}m over 10 m. The first field integral must be below 40 x 10{sup -6} Tm. The second field integral must be below 50 x 10{sup -6} Tm{sup 2}. The phase error between the electron motion and the radiation field must be less than 10 degrees in an undulator. The K parameter must have the value of 3.5000 {+-} 0.0005. The phase matching from the break regions into the undulator must be accurate to better than 10 degrees. A phase change of 113 x 2{pi} must take place over a distance of 3.656 m centered on the undulator. Achieving these requirements is the goal of the tuning process. Most of the tuning is done with Hall probe measurements. The field integrals are checked using long coil measurements. An analysis program written in Matlab takes the Hall probe measurements and computes the trajectories, phase errors, K value, etc. The analysis program and its calculation techniques were described in a previous note. In this note, a second Matlab program containing tuning algorithms is described. The algorithms to determine the required number and placement of the shims are discussed in detail. This note describes the operation of a computer program which was written to automate LCLS undulator tuning. The algorithms used to compute the shim sizes and locations are discussed.
Considerable effort has been devoted to the development of superconducting undulators (SCUs) intended for particle accelerator-based light sources, including synchrotrons and free electron laser (FEL) facilities. Recently, a high-temperature superconducting (HTS) undulator prototype, consisting of staggered-array Re-Ba-Cu-O bulks, achieved an on-axis sinusoidal magnetic field profile with a peak amplitude B$_0$ of 2.1 T and a period length of 10 mm, resulting in a deflection parameter K = 1.96. Such a short period HTS undulator not only enables the generation of higher-energy photons, but also supports the construction of economically feasible and compact FELs with shorter linear accelerators (LINACs). This article provides a comprehensive review of recent advances in the staggered-array bulk HTS undulator as well as other types of HTS undulators. Furthermore, it offers insights into the development of engineering HTS undulator prototypes designed for deployment in synchrotron and free electron laser (FEL) facilities. We conclude by discussing opportunities for and the challenges facing the use of HTS undulators in practical applications.
The possibility of utilizing plasma undulators and plasma accelerators to produce compact ultraviolet and X-ray sources, has attracted considerable interest for a few decades. This interest has been driven by the great potential to decrease the threshold for accessing such sources, which are mainly provided by a few dedicated large-scale synchrotron or free-electron laser (FEL) facilities. However, the broad radiation bandwidth of such plasma devices limits the source brightness and makes it difficult for the FEL instability to develop. Here in this paper, using multi-dimensional particle-in-cell (PIC) simulations, we demonstrate that a plasma undulator generated by the beating of a mixture of high-order laser modes propagating inside a plasma channel, leads to a few percent radiation bandwidth. The strength of the undulator can reach unity, the period can be less than a millimeter, and the number of undulator periods can be significantly increased by a phase locking technique based on the longitudinal tapering. Polarization control of such an undulator can be achieved by appropriately choosing the phase of the modes. According to our results, in the fully beam loaded regime, the electron current in the plasma undulator can reach 0.3 kA level, making such an undulator a potential candidate towards a table-Top FEL.
The HiSOR is a small racetrack type storage ring aiming for usage of synchrotron radiation. This ring is equipped with two undulators. One of them is a linear undulator and another is a helical one. These undulators serve high-flux VUV photon beams. Therefore, these beamlines are oversubscribed mainly for the high precision photo-electron spectroscopy experiments to investigate various materials. To solve this problem, we investigated possibilities to replace present undulators and beamline optics to those with better performance. One of such candidate undulator beamlines is a two-branch-beamline with a single elliptical undulator. Another candidate is a beamline equipped with a quasi-periodic undulator.
The THz undulator has a higher gain to realize a much brighter X-ray at saturation, compared with the optical undulator under the same undulator strength and beam quality. In order to fill the high-power THz gap and realize the THz undulator, two superimposed laser pulses at normal incidence to the electron-beam moving direction form an equivalent high-field THz undulator by the frequency difference to realize the high-gain X-ray Free electron laser. The pulse front tilt of lateral fed lasers is used to realize the electron-laser synchronic interaction. By PIC simulation, a higher gain and a larger X-ray radiation power by the beat wave THz undulator could be realized, compared with the optical undulator for the same electron beam parameters.
The new free electron laser facility Linear Coherent Light Source II (LCLS-II) under construction at SLAC National Accelerator Laboratory will use planar variable gap undulators of hybrid type for the production of free electron laser (FEL) radiation. The LCLS-II will include two FELs with two separate rows of undulators to generate soft and hard x-rays. The soft x-rays will be produced by undulators with 39 mm period length (SXR) and the hard x-rays will be produced by undulators with 26 mm period length (HXR). Both the SXR and the HXR undulators are 3.4 m long and they use a common support structure and frame. In total 21 SXR and 32 HXR undulators will be produced by Lawrence Berkeley National Laboratory in collaboration with SLAC National Accelerator Laboratory. A full-scale prototype with 32 mm period length, called HXU, has been assembled at Lawrence Berkeley National Laboratory (LBNL). The present status of the design, prototyping, and pre-series production of the SXR and HXR undulators are presented in this paper together with the first results from measurements on the full scale HXU prototype.