Engineering Papers⌕ Search

DOE OSTI · 1546739

X-ray free electron laser tuning for variable-gap undulators

Abstract

A tuning method for hard x-ray free electron lasers is presented which combines electron-beam-based alignment (EBBA) with undulator radiation spectrum analysis. This method is conducive to achieving a dispersion-free orbit, finding the undulator field center, and determining the accurate value of the gap distance for the operating undulator K for each undulator segment, and it proves to be highly reliable and robust for free electron laser lasing with variable-gap undulators. The effect of the natural focusing of the undulator on the EBBA is confirmed with measurements and a theoretical analysis. The tilt of an undulator segment subject to ground movement introduces an undulator field change which the electron beam interacts with and can be corrected by K tuning to find a precise compensating gap distance. Lattice matching with a wire-scanner-based Twiss parameter measurement along the undulator line enables the EBBA reference orbit to coincide with the e-beam distribution.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Kang, Heung -Sik, Loos, Henrik. 2019-06-21. X-ray free electron laser tuning for variable-gap undulators. https://doi.org/10.1103/physrevaccelbeams.22.060703

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

High Multiplicity Trigger for long-lived particles in CMS detector

Searches for long-lived particles (LLPs) at the CMS experiment often involve unconventional event topologies that are difficult to efficiently select using standard trigger strategies. To improve sensitivity to such signatures during LHC Run 3 operation, a dedicated High Multiplicity Trigger (HMT) has been developed and deployed in the CMS trigger system. The trigger targets events containing unusually large numbers of hits in the CMS cathode strip chamber (CSC) muon detectors, a characteristic signature of several LLP scenarios involving displaced decays in the muon system. The HMT implementation, trigger logic, rate dependence with pileup, and operational stability are described. Optimized hit multiplicity thresholds are used to maintain acceptable trigger rates under high-luminosity and high-pileup conditions while preserving high efficiency across a broad range of LLP lifetimes and kinematic regimes. The trigger performance is evaluated using both simulated event samples and proton-proton collision data collected during Run 3 of the LHC. The HMT substantially extends the CMS sensitivity to non-standard signatures associated with LLP decays and provides a flexible platform for future searches for physics beyond the Standard Model.

47 OTHER INSTRUMENTATION↗