Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “temperature verification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Evidence Theory Representations for Properties Associated With Weak Link/Strong Link Systems, Part 1: Loss of Assured Safety

The use of evidence theory in the analysis of loss of assured safety (LOAS) for weak link (WL)/strong link (SL) systems is introduced and illustrated. Furthermore, article content includes (i) an introduction to evidence theory, (ii) definition of two WLs and two SLs used for illustration, (iii) belief and plausibility for the occurrence of LOAS for a one WL/two SL system, and (iv) a sampling-based procedure for the verification of belief and plausibility calculations. The presented results can be generalized to systems with more than one WL and two SLs.

42 ENGINEERING↗

Real-Time Drilling Optimization System for Improved Overall Rate of Penetration and Reduced Cost Per Foot in Geothermal Drilling

The key to success in geothermal drilling is economic feasibility, and a major cost in the development of geothermal resources is the actual drilling of the wells. In this project, a real-time drilling optimization system for geothermal drilling was developed. The system couples three individual components while drilling. The first component is a drill stem vibration analysis model, the second is Mechanical Specific Energy (MSE) analyses, and the third is a detailed PDC Rate of Penetration (ROP) drill bit model for optimum RPM and WOB combinations. The benefit of the coupled system is that the range of WOB and RPM could be selected to avoid drill stem vibrations. Secondly, MSE is used as an efficiency measure and the detailed PDC drill bit model ensures the drill bit does not endure temperatures that exceed the temperature at which the PDC cutters experience accelerated wear. The new detailed PDC bit model is based on rock/bit interaction that physically tracks the PDC cutter wear flats as the bit drills ahead giving the capability to calculate the temperature being generated underneath the worn cutters to better advise on operational parameters to avoid accelerated cutter wear and failure and to ensure that operational parameters are applied so that overall ROP is maximized. By combining the drill stem vibrations and the detailed PDC bit cutter wear and “safe” non-accelerated cutter wear temperature and optimum ranges of operating parameters, it results in higher ROP and lower cost drilling. Single cutter PDC testing performed in different lithologies at Sandia was utilized to verify the PDC cutter forces and depth of cut for new and worn cutters. Based on single cutter PDC temperature modeling, verification using single cutter data from the testing done by National Oilwell Varco (NOV) was performed. Sandia’s Hard-Rock Drilling Facility (HRDF) was utilized to test different drill bit configurations with different cutter designs and wear status with different induced modes of vibration to obtain the critical bit RPM/WOB ranges resulting in ineffective drilling and low ROP. The collected test data were further used to verify and calibrate the full hole PDC ROP model that was developed based on single cutter interaction data. A full coupled drill stem vibration model was formulated and verified with geothermal field data from the Chocolate Mountain Aerial Gunnery Range (CMAGR). A graphical user interface (GUI) was developed using Tkinter library in the computer programming language Python, which integrates all the developed models in one system. The developed system consists mainly of the PDC ROP model, PDC bit wear model, PDC cutter temperature model, Mechanical Specific Energy (MSE) model, and drillstring vibration model integrated into one system. The developed system can be used for both, post well analysis and real-time optimization using different criteria such as ROP maximization or MSE minimization. The software uses Differential Evolution Algorithm (DEA) to find optimum values for operational parameters based on last foot drilled while avoiding the drillstring vibration and cutter temperature critical operating parameters.

15 GEOTHERMAL ENERGY↗

METCAN verification status

The status of the verification (comparisons of predictions with experimental data) of the METCAN (METal-matrix Composite ANalyzer) code at high temperature is summarized. Verification includes select available room temperature of W/Cu composites for different fiber volume ratios. It also includes high temperature properties for thermal expansion, moduli, strength and stress/strain behavior for SiC/Ti composites. Furthermore it includes limited cases for thermal fatigue strength degradation. The verification results summarized herein indicate that METCAN simulates complex high temperature metal matrix composite bahavior with reasonable accuracy and that it can be used with confidence to identify in-situ nonlinear behavior that influences composite properties.

Chamis, Christos C.↗

AXAF-I Low Intensity-Low Temperature (LILT) Testing of the Development Verification Test (DVT) Solar Panel

The planned orbit of the AXAF-I spacecraft will subject the spacecraft to both short, less than 30 minutes for solar and less than 2 hours for lunar, and long earth eclipses and lunar eclipses with combined conjunctive duration of up to 3 to 4 hours. Lack of proper Electrical Power System (EPS) conditioning prior to eclipse may cause loss of mission. To avoid this problem, for short eclipses, it is necessary to off-point the solar array prior to or at the beginning of the eclipse to reduce the battery state of charge (SOC). This yields less overcharge during the high charge currents at sun entry. For long lunar eclipses, solar array pointing and load scheduling must be tailored for the profile of the eclipse. The battery SOC, loads, and solar array current-voltage (I-V) must be known or predictable to maintain the bus voltage within acceptable range. To address engineering concerns about the electrical performance of the AXAF-I solar array under Low Intensity and Low Temperature (LILT) conditions, Marshall Space Flight Center (MSFC) engineers undertook special testing of the AXAF-I Development Verification Test (DVT) solar panel in September-November 1997. In the test the DVT test panel was installed in a thermal vacuum chamber with a large view window with a mechanical "flapper door". The DVT test panel was "flash" tested with a Large Area Pulse Solar Simulator (LAPSS) at various fractional sun intensities and panel (solar cell) temperatures. The testing was unique with regards to the large size of the test article and type of testing performed. The test setup, results, and lessons learned from the testing will be presented.

Alexander, Doug↗

Verification of the Multi-Axial, Temperature and Time Dependent (MATT) Failure Criterion

An extensive test and analytical effort has been completed by the Space Shuttle's Reusable Solid Rocket Motor (KSKM) nozzle program to characterize the failure behavior of two epoxy adhesives (TIGA 321 and EA946). As part of this effort, a general failure model, the "Multi-Axial, Temperature, and Time Dependent" or MATT failure criterion was developed. In the initial development of this failure criterion, tests were conducted to provide validation of the theory under a wide range of test conditions. The purpose of this paper is to present additional verification of the MATT failure criterion, under new loading conditions for the adhesives TIGA 321 and EA946. In many cases, the loading conditions involve an extrapolation from the conditions under which the material models were originally developed. Testing was conducted using three loading conditions: multi-axial tension, torsional shear, and non-uniform tension in a bondline condition. Tests were conducted at constant and cyclic loading rates ranging over four orders of magnitude. Tests were conducted under environmental conditions of primary interest to the RSRM program. The temperature range was not extreme, but the loading ranges were extreme (varying by four orders of magnitude). It should be noted that the testing was conducted at temperatures below the glass transition temperature of the TIGA 321 adhesive. However for the EA946, the testing was conducted at temperatures that bracketed the glass transition temperature.

Richardson, David E.↗

Infusible Thermoplastic Composites for Wind Turbine Blade Manufacturing: Fatigue Life of Thermoplastic Laminates under Ambient and Low-Temperature Conditions

Traditionally, thermoset resins such as polyesters (PE) and epoxies are used as the polymer matrix for construction of wind turbine blades. However, concern about their end-of-life treatment garners interest to use thermoplastics for increased recyclability. However, the high viscosity of molten thermoplastics inhibits their use in manufacturing wind turbine blades with injection or compression molding. A recently developed, infusible, reactive thermoplastic resin overcomes this technological barrier. Toward verifying that this recyclable resin is suitable for use in wind turbine blades, a dataset of R?=?0.1 and R?=?10 fatigue data for glass fiber-reinforced acrylic composites is provided and equal fatigue life to industry standard epoxy and unsaturated PE resin systems is demonstrated. Specifically, R?=?0.1 fatigue data for acrylic composites at room temperature and -30?degrees C for verification of low-temperature performance are tabulated. To elucidate failure mechanisms, in situ mechanical testing with X-ray computed tomography demonstrates that damage accumulation occurs by crack propagation along the fiber-matrix interface under cyclic loading. Infrared (IR) thermography predicts failure points in composites specimens with porosity defects introduced from nonideal manufacturing processes. Furthermore, these manufacturing defects are shown to compromise the fatigue life of the acrylic laminates by an order of magnitude.

effect of defects↗

Development of advanced high-temperature heat flux sensors. Phase 2: Verification testing

A two-phase program is conducted to develop heat flux sensors capable of making heat flux measurements throughout the hot section of gas turbine engines. In Phase 1, three types of heat flux sensors are selected; embedded thermocouple, laminated, and Gardon gauge sensors. A demonstration of the ability of these sensors to operate in an actual engine environment is reported. A segmented liner of each of two combustors being used in the Broad Specification Fuels Combustor program is instrumented with the three types of heat flux sensors then tested in a high pressure combustor rig. Radiometer probes are also used to measure the radiant heat loads to more fully characterize the combustor environment. Test results show the heat flux sensors to be in good agreement with radiometer probes and the predicted data trends. In general, heat flux sensors have strong potential for use in combustor development programs.

Atkinson, W. H.↗

Constitutive modelling of single crystal and directionally solidified superalloys

The trend towards improved engine efficiency and durability places increasing demands on materials that operate in the hot section of the gas turbine engine. These demands are being met by new coatings and materials such as single crystal and directionally solidified nickel-base superalloys which have greater creep/fatigue resistance at elevated temperatures and reduced susceptibility to grain boundary creep, corrosion and oxidation than conventionally cast alloys. Work carried out as part of a research program aimed at the development of constitutive equations to describe the elevated temperature stress-strain-time behavior of single crystal and directionally solidified turbine blade superalloys is discussed. The program involves both development of suitable constitutive models and their verification through elevated temperature tension-torsion testing of single crystals of PWA 1480.

Jordan, E. H.↗

Multiwavelength Pyrometer Developed for Use at Elevated Temperatures in Aerospace Applications

Researchers at the NASA Glenn Research Center have developed a unique multiwavelength pyrometer for aerospace applications. It has been shown to be a useful and versatile instrument for measuring the surface temperatures of ceramic zirconia thermal barrier coatings (TBCs) and alumina, even when their emissivity is unknown. The introduction of fiber optics into the pyrometer has greatly increased the ease of using this instrument. Direct comparison of measurements obtained using the pyrometer and thin film thermocouples on a sample provided independent verification of pyrometry temperature measurement. Application of the pyrometer has also included simultaneous surface and bulk temperature measurement in a transparent material, the measurement of combustion gas temperatures in the flames of an atmospheric burner, the measurement of the temperature distribution appearing on a large surface from the recording of just a single radiation spectrum emitted from this nonuniform temperature surface, and the measurement of some optical properties for special aeronautical materials-such as nanostructured layers. The multiwavelength pyrometer temperature is obtained from a radiation spectrum recorded over a broad wavelength region by transforming it into a straight line segment(s) in part or all of the spectral region. The intercept of the line segment(s) with the vertical axis at zero wavelength gives the inverse of the temperature. In a two-color pyrometer, the two data points are also amenable to this analysis to determine the unknown temperature. Implicit in a two-color pyrometer is the assumption of wavelength-independent emissivity. Its two (and minimum) pieces of data are sufficient to determine this straight line. However, a multiwavelength pyrometer not only has improved accuracy but also confirms that the wavelength-independent emissivity assumption is valid when a multitude of data points are shown to lie on a simple straight line.

Ng, Daniel L.↗

Quantum shot noise in tunnel junctions

The current and voltage fluctuations in a normal tunnel junction are calculated from microscopic theory. The power spectrum can deviate from the familiar Johnson-Nyquist form when the self-capacitance of the junction is small, at low temperatures permitting experimental verification. The deviation reflects the discrete nature of the charge transfer across the junction and should be present in a wide class of similar systems.

Ben-Jacob, E.↗

Further development of the dynamic gas temperature measurement system

The objective of this effort was to experimentally verify a dynamic gas temperature measurement system in laboratory experiments. The dynamic gas temperature measurement system verification program is described. A brief description of the sensor geometry and construction is followed by a discussion of the probe heat transfer analysis and subsequent compensation method. The laboratory experiments are described and experimental results are discussed. Finally, directions for further investigation are given.

Elmore, D. L.↗

Restudy of pyroxene-pyroxene equilibration temperature for ordinary chondrite meteorites

Experimental verification of the conclusions of Van Schmus and Koffman (1967) that the equilibration temperatures of ordinary chondrites are roughly the same regardless of classification, and that these temperatures range from 770 to 860 C. The higher average relative equilibrium temperatures found are attributed to improvements in microprobe techniques, and better standards and correction procedures introduced over the last six years. Agreement is expressed with their conclusion that ordinary chondrites embody equilibria achieved within the metamorphic temperature regime and not under igneous temperatures as postulated earlier by Craig (1964) and Mueller (1964).

Bunch, T. E.↗

Lay out, test verification and in orbit performance of HELIOS a temperature control system

HELIOS temperature control system is described. The main design features and the impact of interactions between experiment, spacecraft system, and temperature control system requirements on the design are discussed. The major limitations of the thermal design regarding a closer sun approach are given and related to test experience and performance data obtained in orbit. Finally the validity of the test results achieved with prototype and flight spacecraft is evaluated by comparison between test data, orbit temperature predictions and flight data.

Brungs, W.↗

Noise adding radiometer performance analysis

The DSN noise adding radiometer (NAR) measurement accuracy is analyzed. The NAR capability is part of the precision power monitor function recently introduced in the DSN. The potential system noise temperature measurement accuracy is estimated to be about 1.5% with the 1 kelvin noise diode. Performance verification requires comparison noise temperature measurements with the manual Y factor method and routine monitoring of critical elements in the NAR system such as system linearity and noise diode calibration. A technique is presented to calibrate and reduce the effects of the receiving system nonlinearity. Unsatisfactory performance or degradation of these critical NAR elements would require appropriate system upgrading.

Stelzried, C.↗