Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) Onboard Calibration System

The AVIRIS instrument uses an onboard calibration system to provide auxiliary calibration data. The system consists of tungsten halogen cycle lamp imaged onto a fiber bundle through an eight position filter wheel. The fiber bundle illuminates the back side of the foreoptics shutter during a pre-run and post-run calibration sequence. The filter wheel contains 2 neutral density filters, 5 spectral filters and blocked position.

spectrometer↗

Performance evaluation of the solar backscatter ultraviolet radiometer, model 2 (SBUV/2) inflight calibration system

The Solar Backscatter Ultraviolet Radiometer, Model 2 (SBUV/2) instruments, as part of their regular operation, deploy ground aluminum reflective diffusers to deflect solar irradiance into the instrument's field-of-view. Previous SBUV instrument diffusers have shown a tendency to degrade in their reflective efficiencies. This degradation will add a trend to the ozone measurements if left uncorrected. An extensive in-flight calibration system was designed into the SBUV/2 instruments to effectively measure the degradation of the solar diffuser (Ball Aerospace Systems Division 1981). Soon after launch, the NOAA-9 SBUV/2 calibration system was unable to track the diffuser's reflectivity changes due, in part, to design flows (Frederick et al. 1986). Subsequently, the NOAA-11 SBUV/2 calibration system was redesigned and an analysis of the first 2 years of data (Weiss et al. 1991) indicated the NOAA-11 SBUV/2 onboard calibration system's performance to be exceeding preflight expectations. This paper will describe the analysis of the first three years NOAA-11 SBUV/2 calibration system data.

Weiss, H.↗

Uncertainty Analysis of the Single-Vector Force Balance Calibration System

This paper presents an uncertainty analysis of the Single-Vector Force Balance Calibration System (SVS). This study is focused on the uncertainty involved in setting the independent variables during the calibration experiment. By knowing the uncertainty in the calibration system, the fundamental limits of the calibration accuracy of a particular balance can be determined. A brief description of the SVS mechanical system is provided. A mathematical model is developed to describe the mechanical system elements. A sensitivity analysis of these parameters is carried out through numerical simulations to assess the sensitivity of the total uncertainty to the elemental error sources. These sensitivity coefficients provide valuable information regarding the relative significance of the elemental sources of error. An example calculation of the total uncertainty for a specific balance is provided. Results from this uncertainty analysis are specific to the Single-Vector System, but the approach is broad in nature and therefore applicable to other measurement and calibration systems.

Parker, Peter A.↗

Atmospheric simulator and calibration system for remote sensing radiometers

A system for calibrating the MAPS (measurement of air pollution from satellites) instruments was developed. The design of the system provides a capability for simulating a broad range of radiant energy source temperatures and a broad range of atmospheric pressures, temperatures, and pollutant concentrations for a single slab atmosphere. The system design and the system operation are described.

Holland, J. A.↗

Image synthesis for SAR system, calibration and processor design

The Point Scattering Method of simulating radar imagery rigorously models all aspects of the imaging radar phenomena. Its computational algorithms operate on a symbolic representation of the terrain test site to calculate such parameters as range, angle of incidence, resolution cell size, etc. Empirical backscatter data and elevation data are utilized to model the terrain. Additionally, the important geometrical/propagation effects such as shadow, foreshortening, layover, and local angle of incidence are rigorously treated. Applications of radar image simulation to a proposed calibrated SAR system are highlighted: soil moisture detection and vegetation discrimination.

Holtzman, J. C.↗

SSME Automated Engine Calibration System (AECS)

An algorithm is derived for the real-time calibration of the engine fuel flowmeter and the engine mixture ratio during Space Shuttle Main Engine (SSME) ground testing. Because currently used calibration methods are post-test operations, there exists no fail-safe way of predicting at what mixture ratio a planned test will run. It is proposed that the algorithm developed here be used as part of an Automated Engine Calibration System (AECS) which could ensure that nearly all SSME tests are run at the proper mixture ratio. In this way, AECS has the potential of increasing the efficiency of the SSME ground test program. In addition to the derivation of the algorithm, an overview of this calibration system is presented along with the list of test stand facility instrumentation necessary for AECS implementation.

Greene, William D.↗

Gauge calibration system based on piston manometer

An unbaked calibration system is described that permits absolute calibration with a piston manometer in the range 0.0002 to 6 Pa, with a probable error of 5 microPa + 0.8%, or in the range 0.00008 to 0.02 Pa, with a probable error of 2 microPa + 1%. Procedures and techniques that permit this performance are detailed. For hot-cathode ion gauges, the magnitudes of systematic corrections for envelope temperature and grid current are also indicated.

Warshawsky, I.↗

SSME Automated Engine Calibrating System (AECS) alternative algorithm

An algorithm is derived for the real-time calibration of the engine mixture ratio during SSME ground testing. Because currently used calibration methods are post-test operations, there exists no fail-safe way of predicting at what mixture ratio a planned test will run. It is proposed that the algorithm developed here be used as part of an AECS which could ensure that nearly all SSME tests are run at the proper mixture ratio. In this way, AECS has the potential of increasing the efficiency of the SSME ground test program. This algorithm is an alternative to that presented in a previous paper. In addition to the derivation of the algorithm, an overview of this calibration system is presented along with a discussion of a possible single coefficient calibration system and the list of test stand facility instrumentation necessary for AECS implementation.

Greene, William D.↗

Acoustical transducer calibrating system and apparatus

An acoustical transducer calibrating system includes a differential pressure actuating device having an inner chamber for applying differential pressures to the transducer, and an outer chamber for vacuum sealing. Mounted within the inner chamber is an electrostatic actuator for exciting the transducer at selected frequencies so that its sensitivity can be determined for different operating ambient pressures.

Lewis, T. L.↗

MINITRACK CALIBRATION SYSTEM

Description of calibration cameras and associated equipment employed in airplane calibrations of the minitrack satellite tracking station

SATELLITE TRACKING↗

Wireless Inclinometer Calibration System

A special system was fabricated to properly calibrate the wireless inclinometer, a new device that will measure the Orbiter s hang angle. The wireless inclinometer has a unique design and method of attachment to the Orbiter that will improve the accuracy of the measurements, as well as the safety and ease of the operation. The system properly calibrates the four attached inclinometers, in both the horizontal and vertical axes, without needing to remove any of the component parts. The Wireless Inclinometer Calibration System combines (1) a calibration fixture that emulates the point of attachment to the Orbiter in both the horizontal and vertical axes and the measurement surfaces, (2) an application-specific software program that accepts calibration data such as dates, zero functions, or offsets and tables, and (3) a wireless interface module that enables the wireless inclinometer to communicate with a calibration PC.

Source record↗

Volume-ratio calibration system for vacuum gages

Volume-ratio calibration system consists of a gas source, high pressure gauge, small volume tank, large volume chamber, plus appropriate piping, valves, and vacuum source. This system used in conjunction with commercial vacuum gauges evaluates its ability to accurately produce desired pressures in the .000001 to .01 torr range.

Source record↗

Development and Characterization of a Low-Pressure Calibration System for Hypersonic Wind Tunnels

Minimization of uncertainty is essential for accurate ESP measurements at very low free-stream static pressures found in hypersonic wind tunnels. Statistical characterization of environmental error sources requires a well defined and controlled calibration method. A calibration system has been constructed and environmental control software developed to control experimentation to eliminate human induced error sources. The initial stability study of the calibration system shows a high degree of measurement accuracy and precision in temperature and pressure control. Control manometer drift and reference pressure instabilities induce uncertainty into the repeatability of voltage responses measured from the PSI System 8400 between calibrations. Methods of improving repeatability are possible through software programming and further experimentation.

Green, Del L.↗

Automatic calibration system for pressure transducers

Fifty-channel automatic pressure transducer calibration system increases quantity and accuracy for test evaluation calibration. The pressure transducers are installed in an environmental tests chamber and manifolded to connect them to a pressure balance which is uniform.

Source record↗

Recent Developments and Status of the Langley Single Vector Balance Calibration System (SVS)

The Langley Research Center (LaRC) Single Vector Balance Calibration System (SVS) was first introduced in 2000 by Peter Parker. The SVS combines the Design of Experiments (DOE) methodology with a novel load application system. Since that time three systems have been designed and developed with different load range capabilities (ranging from 2 pounds to 3,000 pounds). Approximately fifteen balances have been calibrated and their data compared to conventional techniques. This paper will present results of these comparisons, based on the mathematical models and accuracies, and discuss differences that were observed. In addition, changes in the implementation of the initial load schedules developed using DOE will be highlighted. One of the principles behind DOE is randomization. The initial loading schedules used to date have been randomized in the traditional DOE sense but not for repeat calibrations or experiments. Implementation of this randomization within blocks and its impact on data quality will be reviewed. Areas of potential future development will be presented which include changes in the centers to include loads with the force position system in the pure error estimates.

Jones, Shirley M.↗

Precision ozone calibration system based on vapor pressures of ozone

A precision ozone calibration system for stratospheric research has been developed and evaluated. Vapor pressures above solid ozone are mixed with a carrier gas (N2) to produce stratospheric ozone mixing ratios at total pressures of 1 to cover 20 torr. The uncertainty in the ozone mixing ratios is approximately + or - 1.5 percent, the stability of ozone is + or - 0.3 percent. Experiments to be calibrated may sample the gas mixture over a wide range of flow rates; the maximum throughput of gas with corrections of less than 1 percent to ozone is about 200 torr 1/min. A mass spectrometer system continuously monitors the purity and stability of the N2-O3 gas mixture.

Mauersberger, K.↗