Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “submillimeter-wave”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Low-Noise Submillimeter-Wave Diode

Low noise achieved without usual high resistance. Barrier of p-type material placed between metal anode and heavily-doped gallium arsenide. Ntype epitaxial layer eliminated. Barrier prevents quantum tunneling of electrons between semiconductor and metal. Higher breakdown structure provided.

Mattauch, R. J.↗

Submillimeter-wave receivers - A status report

A development status assessment is presented for the work of U.S. and Western European research groups on heterodyne sub-mm receivers in the 300-1000 GHz frequency range. The applications driving sub-mm receiver and local oscillator source technologies are radio astronomy, atmospheric measurements, plasma diagnostics, and laboratory spectroscopy. Progress is concentrated in two areas, cooled Schottky diode mixers and solid state local oscillators employing frequency multipliers.

Wilson, W. J.↗

High-Rydberg Xenon Submillimeter-Wave Detector

Proposed detector for infrared and submillimeter-wavelength radiation uses excited xenon atoms as Rydberg sensors instead of customary beams of sodium, potassium, or cesium. Chemically inert xenon easily stored in pressurized containers, whereas beams of dangerously reactive alkali metals must be generated in cumbersome, unreliable ovens. Xenon-based detector potential for infrared astronomy and for Earth-orbiter detection of terrestrial radiation sources. Xenon atoms excited to high energy states in two stages. Doubly excited atoms sensitive to photons in submillimeter wavelength range, further excited by these photons, then ionized and counted.

Chutjian, Ara↗

The laboratory millimeter- and submillimeter-wave spectrum of the first two excited torsional states of (C-13)H3OH

The rotational-torsional spectrum of (C-13)H3OH is presented in both the symmetric and degenerate substates of the first two excited torsional states. Of the new transitions reported, 122 lines are from the v(t) = 1 torsional state and 110 lines are from the v(t) = 2 torsional state, and all are confined to the rotational quantum number J = 8 or less. The data are combined with previously reported millimeter and submillimeter data for the v(t) = 0 torsional state and 44 previously measured excited torsional state lines to form a global data set of 596 transitions, which is analyzed and fitted using an extended internal axis method. The fit results in an overall rms deviation of 1.98 MHz. The spectral constants generated by the fit are used to predict an additional 123 lines of (C-13)H3OH in the v(t) = 1,2 excited torsional states with frequencies up to 612 GHz and rotational quantum number J = 11 or less.

Anderson, Todd↗

Millimeter- and submillimeter-wave surveys of Orion A emission lines in the ranges 200.7-202.3, 203.7-205.3, and 330-360 GHz

A continuous spectral line survey of the Orion A position from 330.5 to 360.1 GHz was carried out. This survey covers nearly the entire 870 micron atmospheric window accessible from ground-based observations. Approximately 160 distinct spectral features composed of about 180 lines were detected, 29 of which could not be readily identified. In addition, Orion A from 200.7 to 202.3 GHz and from 203.7 to 205.3 GHz and 42 distinct new spectral lines were detected, including four that are unidentified at present. These data sets are the first thorough survey results in these spectral regions. The new interstellar lines in the survey bands are tabulated and displayed graphically. Moreover, the data are being made available to the Astronomical Data Center at the Goddard Space Flight Center for distribution by request to the astronomical community.

Jewell, P. R.↗

The submillimeter-wave spectrum of (O-16)(O-18)

In order to aid in the interstellar identification of molecular oxygen via its (O-16)(O-18) isotopic species, the frequencies of four rotational fine-structure lines of (O-16)(O-18) have been measured at frequencies ranging from 298 to 464 GHz. The line with the highest intensity and consequent best chance of astronomical detection lies at 401739.823 MHz. Its magnetic dipole strength is somewhat more than half that of the previously measured strong line at 233946.179 MHz.

Crownover, Richard L.↗

Report of the heterodyne submillimeter-wave sensors panel

After reviewing the science goals of the Astrotech 21 mission set, and comparing the resulting receiver performance requirements with existing technology, the panel determined that there were significant unmet requirements in four areas: local oscillator power and mixer sensitivity in the Tera-Hz regime, infrared spectrometer channel count, and array technology in any form. A comprehensive development plan has been prepared to provide these capabilities in the time frame needed before technology freeze dates of the respective missions. It was also noted that development of these capabilities has immense payoff for future astrophysics missions, as it opens entire new areas of spectroscopy and imaging in the critical submillimeter wave regime rich in molecular transitions.

Wilson, Robert↗

Nonreciprocal reflection-beam isolators for far-infrared use

Magnetoplasma reflection-beam isolators for submillimeter-wave use are discussed in theory and experiment. The basic device uses the Kerr transverse magnetooptic effect (plane of polarization of the EM wave in the plane of incidence, which is perpendicular to a dc magnetic field) in InSb near room temperature. When the semiconductor slab is covered with a thin dielectric layer acting as a matching transformer, improved performance is predicted and observed at 337 microns, and very efficient isolator performance is predicted for 118 microns. Physical arguments are presented to explain the nonreciprocal phenomenon and lead to better device design.

Kanda, M.↗

Facilities for US radioastronomy

An overview of the radio-astronomy field is given, and prospects ready for construction at NASA are presented. A very-long-baseline array consisting of ten 25 m antennas, with a limiting wavelength of 7 mm and an angular resolution at that wavelength of 2 x 10 to the 4th arcsec is discussed. Eighty percent of the phase information will be obtained by closure around the 36 independent triangles, and high quality aperture-synthesis maps will be produced at all wavelengths. The 25 m telescope will be capable of several applications including the discovery of new molecules in our galaxy (in particular, the envelope of the evolved carbon star IRC + 10216), the detection of CO to distances of perhaps 100 million light years, and the understanding of the events which occur as stars are formed from molecular clouds, and as energy is fed back into the molecular gas by new stars. The submillimeter-wave telescope contains the last atmospheric radio windows where astronomical observations can be made from the earth's surface. The need for funding is stressed.

Thaddeus, P.↗

The microwave spectrum of the AlO radical

The rotational spectrum of the aluminum monoxide radical in the ground electronic state X 2Sigma(+) was observed in the millimeter- and submillimeter-wave region. Aluminum monoxide radicals were generated directly in a flow reactor absorption cell by the reaction of N2O with aluminum vaporized from a high-temperature crucible. The observed spectrum was analyzed to yield molecular constants including the rotational constant, centrifugal distortion constant, spin-rotation interaction constant, magnetic hyperfine interaction constants, and nuclear quadrupole coupling constant.

Yamada, Chikashi↗

Edge-Geometry NbN/MgO/NbN Tunnel Junctions

Superconductor/insulator/superconductor (SIS) tunnel junctions fabricated with base and counter electrodes of NbN separated by thin layers of MgO. Useful as submillimeter-wave mixers and fast switches. Use of edge geometry to define small junction makes possible to fabricate junction by process including conventional photolithography.

Hunt, Brian D.↗

Adjustable Support For Instrument Package

Strong, lightweight structure designed to support instrument package. Provides choice of attachment locations to accommodate variety of sizes and shapes. Composed of seven webbed metal parts. Honeycomb panels cover vertical sides of structure. Instrumentation package, such as telescope or infrared sensor, bolted to top of structure. Accompanying electronics boxes mounted on inside surfaces of panels. Weight of instrumentation carried in direct paths through webbed members to base plate. Structure used for submillimeter-wave astronomy satellite.

Sneiderman, Gary↗

Characterization of devices, circuits, and high-temperature superconductor transmission lines by electro-optic testing

The development of a capability for testing transmission lines, devices, and circuits using the optically-based technique of electro-optics sampling was the goal of this project. Electro-optic network analysis of a high-speed device was demonstrated. The project involved research on all of the facets necessary in order to realize this result, including the discovery of the optimum electronic pulse source, development of an adequate test fixture, improvement of the electro-optic probe tip, and identification of a device which responded at high frequency but did not oscillate in the test fixture. In addition, during the process of investigating patterned high-critical-temperature superconductors, several non-contacting techniques for the determination of the transport properties of high T(sub c) films were developed and implemented. These are a transient, optical pump-probe, time-resolved reflectivity experiment, an impulsive-stimulated Raman scattering experiment, and a terahertz-beam coherent-spectroscopy experiment. The latter technique has enabled us to measure both the complex refractive index of an MgO substrate used for high-T(sub c) films and the complex conductivity of a YBa2Cu3O(7-x) sample. This information was acquired across an extremely wide frequency range: from the microwave to the submillimeter-wave regime. The experiments on the YBCO were conducted without patterning of, or contact to, the thin film. Thus, the need for the more difficult transmission-line experiments was eliminated. Progress in all of these areas was made and is documented in a number of papers. These papers may be found in the section listing the abstracts of the publications that were issued during the course of the research.

Whitaker, John F.↗

The Millimeter-Wave Imaging Radiometer (MIR)

The Millimeter-Wave Imaging Radiometer (MIR) is a new instrument being designed for studies of airborne passive microwave retrieval of tropospheric water vapor, clouds, and precipitation parameters. The MIR is a total-power cross-track scanning radiometer for use on either the NASA ER-2 (high-altitude) or DC-8 (medium altitude) aircraft. The current design includes millimeter-wave (MMW) channels at 90, 166, 183 +/- 1,3,7, and 220 GHz. An upgrade for the addition of submillimeter-wave (SMMW) channels at 325 +/- 1,3,7 and 340 GHz is planned. The nadiral spatial resolution is approximately 700 meters at mid-altitude when operated aboard the NASA ER-2. The MIR consists of a scanhead and data acquisition system, designed for installation in the ER-2 superpod nose cone. The scanhead will house the receivers (feedhorns, mixers, local oscillators, and preamplifiers), a scanning mirror, hot and cold calibration loads, and temperature sensors. Particular attention is being given to the characterization of the hot and cold calibration loads through both laboratory bistatic scattering measurements and analytical modeling. Other aspects of the MIR and the data acquisition system are briefly discussed, and diagrams of the location of the MIR in the ER-2 superpod nosecone and of the data acquisition system are presented.

Gasiewski, A. J.↗

Integrated 222-GHz corner-reflector antennas

A high-gain monolithic millimeter-wave antenna has been designed, fabricated, and tested at 222 GHz. The structure consists of a traveling-wave antenna integrated on a 1.2-micron dielectric membrane and suspended in a longitudinal cavity etched in a silicon wafer. A new traveling-wave antenna design yields a wideband input impedance and a low cross-polarization component in the E- and quasi-H-plane patterns. A directivity of 17.7 dB and a main-beam efficiency of 88.5 percent are calculated from the 222-GHz pattern measurements. The integrated corner-reflector antenna is well suited for millimeter- and submillimeter-wave imaging applications in large f-number systems.

Gearhart, Steven S.↗

Resonant-tunnelling diode oscillator using a slot-coupled quasioptical open resonator

A resonant-tunneling diode has oscillated at X-band frequencies in a microwave circuit consisting of a slot antenna coupled to a semiconfocal open resonator. Coupling between the open resonator and the slot oscillator improves the noise-to-carrier ratio by about 36 dB relative to that of the slot oscillator alone in the 100-200 kHz range. A circuit operating near 10 GHz has been designed as a scale model for millimeter- and submillimeter-wave applications.

Stephan, K. D.↗

Abundances in red giant stars - Nitrogen isotopes in carbon-rich molecular envelopes

Results are presented of millimeter- and submillimeter-wave observations of HCN and HCCCN that were made of the circmustellar envelopes of eight carbon stars, including the two protoplanetary nebulae CRL 618 and CRL 2688. The observations yield a measure of the double ratio (N-14)(C-13)/(N-15)(C-12). Measured C-12/C-13 ratios are used to estimate the N-14/N-15 abundance ratio, with the resulting lower limits in all eight envelopes and possible direct determinations in two envelopes. The two determinations and four of the remaining six lower limits are found to be in excess of the terrestrial value of N-14/N-15 = 272, indicating an evolution of the nitrogen isotope ratio, which is consistent with stellar CNO processing. Observations of thermal SiO (v = 0, J = 2-1) emission show that the Si-29/Si-28 ratio can be determined in carbon stars, and further observations are indicated.

Wannier, P. G.↗