Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “specimen holder”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Promoted-Combustion Chamber with Induction Heating Coil

An improved promoted-combustion system has been developed for studying the effects of elevated temperatures on the flammability of metals in pure oxygen. In prior promoted-combustion chambers, initial temperatures of metal specimens in experiments have been limited to the temperatures of gas supplies, usually near room temperature. Although limited elevated temperature promoted-combustion chambers have been developed using water-cooled induction coils for preheating specimens, these designs have been limited to low-pressure operation due to the hollow induction coil. In contrast, the improved promoted-combustion chamber can sustain a pressure up to 10 kpsi (69 MPa) and, through utilization of a solid induction coil, is capable of preheating a metal specimen up to its melting point [potentially in excess of 2,000 F (approximately equal to 1,100 C)]. Hence, the improved promoted combustion chamber makes a greater range of physical conditions and material properties accessible for experimentation. The chamber consists of a vertical cylindrical housing with an inner diameter of 8 in. (20.32 cm) and an inner height of 20.4 in. (51.81 cm). A threaded, sealing cover at one end of the housing can be unscrewed to gain access for installing a specimen. Inlet and outlet ports for gases are provided. Six openings arranged in a helical pattern in the chamber wall contain sealed sapphire windows for viewing an experiment in progress. The base of the chamber contains pressure-sealed electrical connectors for supplying power to the induction coil. The connectors feature a unique design that prevents induction heating of the housing and the pressure sealing surfaces; this is important because if such spurious induction heating were allowed to occur, chamber pressure could be lost. The induction coil is 10 in. (25.4 cm) long and is fitted with a specimen holder at its upper end. At its lower end, the induction coil is mounted on a ceramic base, which affords thermal insulation to prevent heating of the base of the chamber during use. A sapphire cylinder protects the coil against slag generated during an experiment. The induction coil is energized by a 6-kW water-cooled power supply operating at a frequency of 400 kHz. The induction coil is part of a parallel-tuned circuit, the tuning of which is used to adjust the coupling of power to the specimen. The chamber is mounted on a test stand along with pumps, valves, and plumbing for transferring pressurized gas into and out of the chamber. In addition to multiple video cameras aimed through the windows encircling the chamber, the chamber is instrumented with gauges for monitoring the progress of an experiment. One of the gauges is a dual-frequency infrared temperature transducer aimed at the specimen through one window. Chamber operation is achieved via a console that contains a computer running apparatus-specific software, a video recorder, and real-time video monitors. For safety, a blast wall separates the console from the test stand.

Richardson, Erin↗

Dielectrics Under Extreme Electric Fields: In Situ Studies on Nanoscale Mechanisms (Final Technical Report)

The lack of materials that can function reliably under extreme electric fields is a critical roadblock to achieving higher energy efficiency and extended service lifetime of devices in electricity generation, transmission, and consumption. Materials typically fail at two or three orders of magnitude below their theoretical dielectric breakdown strength. Identifying the origins of premature dielectric breakdown using state-of-the-art characterization tools will, therefore, enable the design and discovery of transformational materials capable of approaching their intrinsic limits. The vast improvement in the resolution power of imaging tools, combined with the recently developed in situ electric biasing technique, has made high resolution observations of dielectric breakdown as it happens possible. The overall goal of the project is to directly image the dynamic processes of defect formation, accumulation, and interaction with preexisting defects (e.g., dislocations, domain walls, and grain boundaries in crystalline dielectric films) under electric fields up to 1,000 MV/m with a temporal resolution better than 5 microseconds. Using the newly acquired, custom-made Hysitron PI95 transmission electron microscopy (TEM) specimen holder, in situ TEM observations of breakdown at the sub nanometer resolution will be made on representative dielectric compounds with progressive complexities: the linear dielectric SiO 2 , CuO, and TiO 2 , the ferroelectric BaTiO 3 nanocrystals and nanocubes. Through direct observation of the breakdown event at high spatial and temporal resolutions, the nanoscale mechanisms for the failure of dielectrics under intense electric fields will be identified. The results of the project will be applied to the design and processing of new dielectric materials with higher efficiency, improved reliability, and a prolonged lifetime. Such new dielectrics are urgently needed for modernizing energy infrastructures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Scoping Study for Fast Flux Testing in the Advanced Test Reactor

The value of fast spectrum reactors remains prominent in the nuclear technology portfolio. The performance of these reactors can be maximized with advancements in nuclear fuel technologies, but development of these technologies is currently held back by lack of fast spectrum test reactors available to the United States. Spectral modification of experiment positions in the thermal spectrum Advanced Test Reactor (ATR) has long been used to support fast reactor fuel development, but these methods have not been progressed to their full potential. This study investigated the use of concentric rings of aluminum-clad fuel plates in ATR flux traps and thermal neutron absorbing filters to increase fast neutron flux on test specimens. This concept was termed the Boosted Energy Advanced Spectrum Test (BEAST). This approach will enable irradiation of advanced fuel designs in prototypic-length fuel pins and representative flux environment to support post irradiation exams, enable transient testing, and produce the type of data that will permit lead test assembly irradiations in true Sodium Fast Reactors (SFRs) when they become available. Neutronic predictions were performed to investigate BEAST design options and thermal hydraulic models were produced to ensure feasibility of BEAST. Two versions were considered based on the geometric limitations of ATR’s small and large flux traps. The small version was found to be preferable due to slightly higher fast flux and fast-to-thermal neutron ratio. Perhaps more influentially, the small flux trap option was also preferred to avoid conflict with ongoing very high temperature reactor fuel irradiation programs in ATR’s large northeast flux trap. The small flux trap option provided less than half the test volume of the large version, but still had adequate volume for seven SFR pins in cross section which could be stacked two-high in ATR’s 1.2m long core to accommodate up to 14 EBR-II size pins. The preference for the small flux trap configuration should be revisited if additional collaborative test programs emerge with the need to irradiate a significant volume of additional specimens. Calculations were performed regarding a lithium deuteride ring to convert thermal neutrons into 14 MeV fusion neutrons. At the time this report was written these calculations were partially complete and it remains to be seen whether the concept would be worth including in BEAST. Given the preference for the small flux trap option, which does not afford enough room for the 14 MeV ring, it was concluded to defer future work on the lithium deuteride ring. This decision could be revisited if fusion material research programs emerge for collaborative testing in BEAST. A cadmium-lined specimen holder design was found to be adequate in filtering thermal neutrons and preferred over other neutron absorbers based on past experience with cadmium baskets. It was acknowledged that cadmium-bearing hardware would become depleted and need to be replaced occasionally, which appeared feasible from a mechanical design perspective. Neutronic studies investigated different enrichment levels in the booster fuel using uranium-molybdenum alloy dispersion fuel which has performed well in past ATR irradiations. Both options were able to drive fuel pins to SFR-like fission heating rates. The high enriched booster fuel option outperformed the low enriched option by ~20% on key metrics including fast flux and fast-to-thermal ratio, but the low enriched option was favored in order to broaden options for potential fuel suppliers. The preferred BEAST design options including cadmium filter with low enriched booster fuel in the small flux trap configuration was predicted to achieve 6.2E14 n/cm2sec fast flux (>0.1 MeV) with a fast-to-thermal ratio of 44.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

In situ sputter cleaning of thin film metal substrates for UHV-TEM corrosion studies.

A prerequisite for conducting valid corrosion experiments by in situ electron microscopy techniques is not only the achievement of UHV background pressure conditions at the site of the specimen but also the ability to clean the surface of the thin metal substrate specimen before initiation of the corrosive interaction. A miniaturized simple ion gun has been constructed for this purpose. The gun is small enough to be incorporated into an UHV electron microscope specimen chamber with hot stage in such a way as to permit bombardment of the substrate specimen while observing it by transmission electron microscopy TEM. It is shown that the ion beam generated is confined well enough to cause a sputtering removal of substrate material at a rate of approximately 5-10 A/min and to prevent the sputter deposition of contaminating material from the specimen holder.

Heinemann, K.↗

A simple laboratory method for determining ignitability of materials

A simple laboratory method for determining ignitability of materials is described. The apparatus consists of a Mellen high-flux heater capable of producing up to 13 W/sq cm heat flux, a Medtherm water-cooled radiometer for measuring heat flux, a mounting frame to hold all components in proper position, and specimen holders of the type used for the NBS smoke test. Time to ignition at different heat flux levels is recorded. Test results are presented for a variety of materials.

Hilado, C. J.↗

X-ray measurements of stresses and defects in EFG and large grained polycrystalline silicon ribbons

The Bond method was employed to measure the lattice parameter in an area of 0.4 mm in diameter of EFG Si-ribbons to an accuracy of + or - 0.00008 A. A Bond goniometer was built which included a goniostat with a special specimen holder to mount ribbons 1 m in length and 75 mm in width which could be rotated about two orthogonal axes, and a Leitz microscope for precision alignment of a particular area into the center of the goniostat and the small primary X-ray beam. The (321) planes were found to be parallel to the surface of the ribbons with an angular spread of about 15 deg. The poles of the (111) planes clustered about an angle of 25 deg away from the surface normal, again with a spread of 10 deg. The lattice parameter of a small piece of ribbon material was found to be a sub o = 5.43075 A. A maximum stress of 115 MPa was observed in a fractured ribbon which corresponded to the fracture stress of single crystals of Si.

Wagner, C. N. J.↗

Shock compression of liquid helium to 56 GPa (560 kbar)

Shock-wave data are presented for liquid helium which has been compressed to densities up to five times greater than the normal liquid. The helium was heated to temperatures up to 21,000 K, while the maximum pressure attained was 56 GPa. The properties of helium and hydrogen are important for modeling the giant planets Saturn and Jupiter where these elements are the major constituents. Conditions on Saturn are of particular interest because studies have suggested that this planet has an internal energy source which is associated with unmixing and gravitational separation of the hydrogen-helium fluid at pressures below 1 TPa. The existence of this phase transition depends very sensitively on the hydrogen and helium equation of state. In the experiments, strong shock waves were generated by the impact of planar projectiles into cryogenic specimen holders.

Nellis, W. J.↗

Shock Compression of Liquid Helium to 56 GPa (560) Kbar

Shock-wave data are presented for liquid helium which has been compressed to densities up to five times greater than the normal liquid. The helium was heated to temperatures up to 21,000 K, while the maximum pressure attained was 56 GPa. The properties of helium and hydrogen are important for modeling the giant planets Saturn and Jupiter where these elements are the major constituents. Conditions on Saturn are of particular interest because studies have suggested that this planet has an internal energy source which is associated with unmixing and gravitational separation the hydrogen-helium fluid at pressures below 1 TPa. The existence of this phase transition depends very sensitively on the hydrogen and helium equation of state. In the experiments, strong shock waves were generated by the impact of planar projectiles into cryogenic specimen holders.

Nellis, W. J.↗

Resistance-Welding Test Fixture

Realistic welding conditions produce reliable specimens. Simple fixture holds resistance-welding test specimens. Specimen holder includes metallic holder and clamps to provide electrical and thermal paths and plastic parts providing thermal and electrical isolation.

Brennan, Andrew D.↗

Instrumented Pneumatic-Impact Tester

Pneumatic-impact tester is small pressure chamber equipped with specimen holder and optical port. Device designed to test susceptibility of polymeric material to ignition by "pneumatic impact" in high-pressure gaseous oxygen. Used to determine differences among susceptibilities to ignition of different materials and of different batches of nominally same material proposed for use in systems containing pressurized oxygen. Also used to show characteristics of ignition and combustion.

Shelley, Richard M.↗

Blood Vessel Tension Tester

In the photo, a medical researcher is using a specially designed laboratory apparatus for measuring blood vessel tension. It was designed by Langley Research Center as a service to researchers of Norfolk General Hospital and Eastern Virginia Medical School, Norfolk, Virginia. The investigators are studying how vascular smooth muscle-muscle in the walls of blood vessels-reacts to various stimulants, such as coffee, tea, alcohol or drugs. They sought help from Langley Research Center in devising a method of measuring the tension in blood vessel segments subjected to various stimuli. The task was complicated by the extremely small size of the specimens to be tested, blood vessel "loops" resembling small rubber bands, some only half a millimeter in diameter. Langley's Instrumentation Development Section responded with a miniaturized system whose key components are a "micropositioner" for stretching a length of blood vessel and a strain gage for measuring the smooth muscle tension developed. The micropositioner is a two-pronged holder. The loop of Mood vessel is hooked over the prongs and it is stretched by increasing the distance between the prongs in minute increments, fractions of a millimeter. At each increase, the tension developed is carefully measured. In some experiments, the holder and specimen are lowered into the test tubes shown, which contain a saline solution simulating body fluid; the effect of the compound on developed tension is then measured. The device has functioned well and the investigators say it has saved several months research time.

Source record↗

Electron tomography imaging methods with diffraction contrast for materials research

Transmission electron microscopy (TEM) and scanning transmission electron microscopy (STEM) enable the visualization of three-dimensional (3D) microstructures ranging from atomic to micrometer scales using 3D reconstruction techniques based on computed tomography algorithms. This 3D microscopy method is called electron tomography (ET) and has been utilized in the fields of materials science and engineering for more than two decades. Although atomic resolution is one of the current topics in ET research, the development and deployment of intermediate-resolution (non-atomic-resolution) ET imaging methods have garnered considerable attention from researchers. This research trend is probably not irrelevant due to the fact that the spatial resolution and functionality of 3D imaging methods of scanning electron microscopy (SEM) and X-ray microscopy have come to overlap with those of ET. In other words, there may be multiple ways to carry out 3D visualization using different microscopy methods for nanometer-scale objects in materials. From the above standpoint, this review paper aims to (i) describe the current status and issues of intermediate-resolution ET with regard to enhancing the effectiveness of TEM/STEM imaging and (ii) discuss promising applications of state-of-the-art intermediate-resolution ET for materials research with a particular focus on diffraction contrast ET for crystalline microstructures (superlattice domains and dislocations) including a demonstration of in situ dislocation tomography.

36 MATERIALS SCIENCE↗

Method for determining the effects of oxygen plasma on a specimen

A method for determining the effects of exposure of oxygen plasma on a specimen such as a thin film polymer or thin metals. The method includes providing an apparatus with a chamber having a holder supporting the polymer specimen in a plasma environment provided in the chamber. The chamber is regulated to a predetermined pressure and set temperature prior to the introduction of oxygen plasma therein. The specimen is then subjected to the plasma environment for a predetermined time during which time the temperature of the specimen is sensed and regulated to be maintained at the set temperature. Temperature sensing is accomplished by a probe which senses any changes in bulk sample temperature. Temperature regulation is provided by a thermoelectric module and by a coolant flow tube.

Whitaker, Ann F.↗

Holder for Ultrasonic Evaluation of Small-Diameter Tubes

Simple holder eliminates requirement for expensive turntable. Holder works by rotating cylindrical specimens about y-axis. Rotation synchronized with movement of transducer to permit testing without use of turntable. Holder attached to crossmember of scanning bridge with C-clamp. Permits testing of small-diameter tubes rapidly, accurately, and economically. Designed for use with commercially available electromechanical drum-type ultrasonic immersion testing device used for nondestructive evaluation of variety of materials.

Taylor, E. C.↗

Isolation of Resistance-Bearing Microorganisms

To better exploit the principles of gas transport and mass transport during the processes of cell seeding of 3D scaffolds and in vitro culture of 3D tissue engineered constructs, the oscillatory cell culture bioreactor provides a flow of cell suspensions and culture media directly through a porous 3D scaffold (during cell seeding) and a 3D construct (during subsequent cultivation) within a highly gas-permeable closed-loop tube. This design is simple, modular, and flexible, and its component parts are easy to assemble and operate, and are inexpensive. Chamber volume can be very low, but can be easily scaled up. This innovation is well suited to work with different biological specimens, particularly with cells having high oxygen requirements and/or shear sensitivity, and different scaffold structures and dimensions. The closed-loop changer is highly gas permeable to allow efficient gas exchange during the cell seeding/culturing process. A porous scaffold, which may be seeded with cells, is fixed by means of a scaffold holder to the chamber wall with scaffold/construct orientation with respect to the chamber determined by the geometry of the scaffold holder. A fluid, with/without biological specimens, is added to the chamber such that all, or most, of the air is displaced (i.e., with or without an enclosed air bubble). Motion is applied to the chamber within a controlled environment (e.g., oscillatory motion within a humidified 37 C incubator). Movement of the chamber induces relative motion of the scaffold/construct with respect to the fluid. In case the fluid is a cell suspension, cells will come into contact with the scaffold and eventually adhere to it. Alternatively, cells can be seeded on scaffolds by gel entrapment prior to bioreactor cultivation. Subsequently, the oscillatory cell culture bioreactor will provide efficient gas exchange (i.e., of oxygen and carbon dioxide, as required for viability of metabolically active cells) and controlled levels of fluid dynamic shear (i.e., as required for viability of shear-sensitive cells) to the developing engineered tissue construct. This bioreactor was recently utilized to show independent and interactive effects of a growth factor (IGF-I) and slow bidirectional perfusion on the survival, differentiation, and contractile performance of 3D tissue engineering cardiac constructs. The main application of this system is within the tissue engineering industry. The ideal final application is within the automated mass production of tissue- engineered constructs. Target industries could be both life sciences companies as well as bioreactor device producing companies.

Venkateswaran, Kasthuri, J.↗

Oscillating Cell Culture Bioreactor

To better exploit the principles of gas transport and mass transport during the processes of cell seeding of 3D scaffolds and in vitro culture of 3D tissue engineered constructs, the oscillatory cell culture bioreactor provides a flow of cell suspensions and culture media directly through a porous 3D scaffold (during cell seeding) and a 3D construct (during subsequent cultivation) within a highly gas-permeable closed-loop tube. This design is simple, modular, and flexible, and its component parts are easy to assemble and operate, and are inexpensive. Chamber volume can be very low, but can be easily scaled up. This innovation is well suited to work with different biological specimens, particularly with cells having high oxygen requirements and/or shear sensitivity, and different scaffold structures and dimensions. The closed-loop changer is highly gas permeable to allow efficient gas exchange during the cell seeding/culturing process. A porous scaffold, which may be seeded with cells, is fixed by means of a scaffold holder to the chamber wall with scaffold/construct orientation with respect to the chamber determined by the geometry of the scaffold holder. A fluid, with/without biological specimens, is added to the chamber such that all, or most, of the air is displaced (i.e., with or without an enclosed air bubble). Motion is applied to the chamber within a controlled environment (e.g., oscillatory motion within a humidified 37 C incubator). Movement of the chamber induces relative motion of the scaffold/construct with respect to the fluid. In case the fluid is a cell suspension, cells will come into contact with the scaffold and eventually adhere to it. Alternatively, cells can be seeded on scaffolds by gel entrapment prior to bioreactor cultivation. Subsequently, the oscillatory cell culture bioreactor will provide efficient gas exchange (i.e., of oxygen and carbon dioxide, as required for viability of metabolically active cells) and controlled levels of fluid dynamic shear (i.e., as required for viability of shear-sensitive cells) to the developing engineered tissue construct. This bioreactor was recently utilized to show independent and interactive effects of a growth factor (IGF-I) and slow bidirectional perfusion on the survival, differentiation, and contractile performance of 3D tissue engineering cardiac constructs. The main application of this system is within the tissue engineering industry. The ideal final application is within the automated mass production of tissue- engineered constructs. Target industries could be both life sciences companies as well as bioreactor device producing companies.

Freed, Lisa E.↗

Measuring Hydrogen Concentrations in Metals

Commercial corrosion-measurement system adapted to electrochemical determination of hydrogen concentrations in metals. New technique based on diffusion of hydrogen through foil specimen of metal. In sample holder, hydrogen produced on one side of foil, either by corrosion reaction or by cathodic current. Hydrogen diffused through foil removed on other side by constant anode potential, which leads to oxidation of hydrogen to water. Anode current is measure of concentration of hydrogen diffusing through foil. System used to study hydrogen uptake, hydrogen elimination by baking, effect of heat treatment, and effect of electroplating on high-strength steels.

Danford, M. D.↗

In-Situ Transmission Electron Microscopy Study of the Evolution of Extended Defects in Oxide Nuclear Fuels

In-situ transmission electron microscopy (TEM) with simulated extreme environments is an effective tool for understanding and tracking microstructural changes down to the atomic scale. The objective of this research is to study the effect of temperature on the evolution of extended defects in ThO2 and UO2. Here, we present in-situ TEM isochronal thermal annealing experiments using a micro-electro-mechanical-system (MEMS)-based heating holder. ThO2 and UO2 single crystal specimens were grown inside an inert silver ampoule using hydrothermal synthesis. Both samples were irradiated using 2 MeV protons at 600oC up to 0.1 dpa at Texas A&M University’s Accelerator Laboratory. Fig. 1a shows a weak-beam dark field TEM image of ThO2 after irradiation, indicating the presence of faulted 1/3 <111> type dislocation loops. This presentation will discuss the effect of annealing temperature (600oC, 800oC, 1000oC, 1100oC, etc.) on dislocation loop density, size and distribution, loop nature (interstitial/vacancies) and Burgers vector, as well as the formation of voids in both ThO2 and UO2. This work will also discuss the interaction between defects during annealing. The in-situ TEM annealing cycle is shown in Fig 1b. This research significantly improves the understanding of defect behavior in oxide nuclear fuels with temperature and will aid computational modeling efforts. This work was supported as part of the Center for Thermal Energy Transport under Irradiation (TETI) Energy Frontier Research Center, funded by the U.S. Department of Energy Office of Science.

36 MATERIALS SCIENCE↗