Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “shot optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Optimally tuned starting point for single-shot GW calculations of solids

The dependence of ab initio many-body perturbation theory within the $\textit{GW}$ approximation on the eigensystem used in calculating quasiparticle corrections limits this method's predictive power. Here, we investigate the accuracy of the recently developed Wannier-localized optimally tuned screened range-separated hybrid (WOT-SRSH) functional as a generalized Kohn-Sham starting point for single-shot $\textit{GW}$ ($G_0W_0$) calculations for a range of semiconductors and insulators. Comparison to calculations based on well-established functionals, namely, PBE, PBE0, and HSE, as well as to self-consistent GW schemes and to experiment, shows that band gaps computed via $G_0W_0$@WOT-SRSH have a level of precision and accuracy that is comparable to that of more advanced methods such as quasiparticle self-consistent $\textit{GW}$ and eigenvalue self-consistent $\textit{GW}$. In this work, we also find that $G_0W_0$@WOT-SRSH improves the description of states deeper in the valence band manifold. Finally, we show that $G_0W_0$@WOT-SRSH significantly reduces the sensitivity of computed band gaps to ambiguities in the underlying WOT-SRSH tuning procedure.

36 MATERIALS SCIENCE↗

Laser-system model for enhanced operational performance and flexibility on OMEGA EP

The development of laser performance models having real-time prediction capability for the OMEGA EP laser system has been essential in meeting requests from its user community for increasingly complex pulse shapes that span a wide range of energies. The laser operations model PSOPS provides rapid and accurate predictions of OMEGA EP laser-system performance in both forward and backward directions, a user-friendly interface and rapid optimization capability between shots. We describe the model’s features and show how PSOPS has allowed real-time optimization of the laser-system configuration in order to satisfy the demands of rapidly evolving experimental campaign needs. We also discuss several enhancements to laser-system performance accuracy and flexibility enabled by PSOPS.

42 ENGINEERING↗

Toward monochromated sub-nanometer UEM and femtosecond UED

A preliminary design of a mega-electron-volt (MeV) monochromator with 10 –5 energy spread for ultrafast electron diffraction (UED) and ultrafast electron microscopy (UEM) is presented. Such a narrow energy spread is advantageous in both the single shot mode, where the momentum resolution in diffraction is improved, and the accumulation mode, where shot-to-shot energy jitter is reduced. In the single-shot mode, we numerically optimized the monochromator efficiency up to 13% achieving 1.3 million electrons per pulse. In the accumulation mode, to mitigate the efficiency degradation caused by the shot-to-shot energy jitter, an optimized gun phase yields only a mild reduction of the single-shot efficiency, therefore the number of accumulated electrons nearly proportional to the repetition rate. Inspired by the recent work of Qi et al. (Phys Rev Lett 124:134803, 2020), a novel concept of applying reverse bending magnets to adjust the energy-dependent path length difference has been successfully realized in designing a MeV monochromator to achieve the minimum energy-dependent path length difference between cathode and sample. Thanks to the achromat design, the pulse length of the electron bunches and the energy-dependent timing jitter can be greatly reduced to the 10 fs level. The introduction of such a monochromator provides a major step forward, towards constructing a UEM with sub-nm resolution and a UED with ten-femtosecond temporal resolution. The one-to-one mapping between the electron beam parameter and the diffraction peak broadening enables a real-time nondestructive diagnosis of the beam energy spread and divergence. The tunable electric–magnetic monochromator allows the scanning of the electron beam energy with a 10 –5 precision, enabling online energy matching for the UEM, on-momentum flux maximizing for the UED and real-time energy measuring for energy-loss spectroscopy. A combination of the monochromator and a downstream chicane enables “two-color” double pulses with femtosecond duration and the tunable delay in the range of 10 to 160 fs, which can potentially provide an unprecedented femtosecond time resolution for time resolved UED.

36 MATERIALS SCIENCE↗

Spatialyze: A Geospatial Video Analytics System with Spatial-Aware Optimizations

Videos that are shot using commodity hardware such as phones and surveillance cameras record various metadata such as time and location. We encounter suchgeospatial videoson a daily basis and such videos have been growing in volume significantly. Yet, we do not have data management systems that allow users to interact with such data effectively. In this paper, we describe Spatialyze, a new framework for end-to-end querying of geospatial videos. Spatialyze comes with a domain-specific language where users can construct geospatial video analytic workflows using a 3-step, declarative,build-filter-observeparadigm. Internally, Spatialyze leverages the declarative nature of such workflows, the temporal-spatial metadata stored with videos, and physical behavior of real-world objects to optimize the execution of workflows. Our results using real-world videos and workflows show that Spatialyze can reduce execution time by up to 5.3×, while maintaining up to 97.1% accuracy compared to unoptimized execution.

Computer Science↗

Optimal constraints on local primordial non-Gaussianity from the two-point statistics of large-scale structure

One of the main signatures of primordial non-Gaussianity of the local type is a scale-dependent correction to the bias of large-scale structure tracers such as galaxies or clusters, whose amplitude depends on the bias of the tracers itself. The dominant source of noise in the power spectrum of the tracers is caused by sampling variance on large scales (where the non-Gaussian signal is strongest) and shot noise arising from their discrete nature. Recent work has argued that one can avoid sampling variance by comparing multiple tracers of different bias, and suppress shot noise by optimally weighting halos of different mass. Here we combine these ideas and investigate how well the signatures of non-Gaussian fluctuations in the primordial potential can be extracted from the two-point correlations of halos and dark matter. On the basis of large N-body simulations with local non-Gaussian initial conditions and their halo catalogs we perform a Fisher matrix analysis of the two-point statistics. Compared to the standard analysis, optimal weighting and multiple-tracer techniques applied to halos can yield up to 1 order of magnitude improvements in f{sub NL}-constraints, even if the underlying dark matter density field is not known. In this case one needs to resolve all halos down to 10{sup 10}h{sup -1}M{sub sun} at z=0, while with the dark matter this is already achieved at a mass threshold of 10{sup 12}h{sup -1}M{sub sun}. We compare our numerical results to the halo model and find satisfactory agreement. Forecasting the optimal f{sub NL}-constraints that can be achieved with our methods when applied to existing and future survey data, we find that a survey of 50h{sup -3} Gpc{sup 3} volume resolving all halos down to 10{sup 11}h{sup -1}M{sub sun} at z=1 will be able to obtain {sigma}{sub f{sub N{sub L}}}{approx}1 (68% cl), a factor of {approx}20 improvement over the current limits. Decreasing the minimum mass of resolved halos, increasing the survey volume or obtaining the dark matter maps can further improve these limits, potentially reaching the level of {sigma}{sub f{sub N{sub L}}}{approx}0.1. This precision opens up the possibility to distinguish different types of primordial non-Gaussianity and to probe inflationary physics of the very early Universe.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optimization of laser energy deposition for single-shot high aspect-ratio microstructuring of thick BK7 glass

We investigate the generation of high aspect ratio microstructures across 0.7 mm thick glass by means of single shot Bessel beam laser direct writing. We study the effect on the photoinscription of the cone angle, as well as of the energy and duration of the ultrashort laser pulse. The aim of the study is to optimize the parameters for the writing of a regular microstructure due to index modification along the whole sample thickness. By using a spectrally resolved single pulse transmission diagnostics at the output surface of the glass, we correlate the single shot material modification with observations of the absorption in different portions of the retrieved spectra, and with the absence or presence of spectral modulation. Numerical simulations of the evolution of the Bessel pulse intensity and of the energy deposition inside the sample help us interpret the experimental results that suggest to use picosecond pulses for an efficient and more regular energy deposition. Picosecond pulses take advantage of nonlinear plasma absorption and avoid temporal dynamics effects which can compromise the stationarity of the Bessel beam propagation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of barren plateaus on gradient-free optimization

Barren plateau landscapes correspond to gradients that vanish exponentially in the number of qubits. Such landscapes have been demonstrated for variational quantum algorithms and quantum neural networks with either deep circuits or global cost functions. For obvious reasons, it is expected that gradient-based optimizers will be significantly affected by barren plateaus. However, whether or not gradient-free optimizers are impacted is a topic of debate, with some arguing that gradient-free approaches are unaffected by barren plateaus. Here we show that, indeed, gradient-free optimizers do not solve the barren plateau problem. Our main result proves that cost function differences, which are the basis for making decisions in a gradient-free optimization, are exponentially suppressed in a barren plateau. Hence, without exponential precision, gradient-free optimizers will not make progress in the optimization. We numerically confirm this by training in a barren plateau with several gradient-free optimizers (Nelder-Mead, Powell, and COBYLA algorithms), and show that the numbers of shots required in the optimization grows exponentially with the number of qubits.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Referenceless, grating-based, single shot X-ray phase contrast imaging with optimized laser-driven K-α sources

With its ability to efficiently probe low-Z materials, X-ray phase imaging methods have recently raised high interest in multiple fields from biology and medical applications to high energy density (HED) physics. Initially developed with synchrotron light and X-ray tubes, we present a novel grating based Talbot X-ray deflectometer (TXD) diagnostic that was coupled with laser-generated K-α X-ray sources. The multi-terawatt laser (I > 1 × 10 14 W cm -2 ) was used as a testbed for diagnostic development. It was found that X-ray source chromaticity plays an important role in TXD. Indeed, the broadband spectrum of laser-generated X-ray sources may strongly impact image quality and thus diagnostic performance. We qualified X-ray emission from different laser-produced sources and determined laser, target, and deflectometer parameters that optimize TXD performance. We present the first results of referenceless grating-based X-ray imaging at high-power laser facilities and discuss the implications of this new development in HED research.

47 OTHER INSTRUMENTATION↗

A framework to evaluate machine learning crystal stability predictions

The rapid adoption of machine learning in various scientific domains calls for the development of best practices and community agreed-upon benchmarking tasks and metrics. We present Matbench Discovery as an example evaluation framework for machine learning energy models, here applied as pre-filters to first-principles computed data in a high-throughput search for stable inorganic crystals. We address the disconnect between (1) thermodynamic stability and formation energy and (2) retrospective and prospective benchmarking for materials discovery. Alongside this paper, we publish a Python package to aid with future model submissions and a growing online leaderboard with adaptive user-defined weighting of various performance metrics allowing researchers to prioritize the metrics they value most. To answer the question of which machine learning methodology performs best at materials discovery, our initial release includes random forests, graph neural networks, one-shot predictors, iterative Bayesian optimizers and universal interatomic potentials. We highlight a misalignment between commonly used regression metrics and more task-relevant classification metrics for materials discovery. Accurate regressors are susceptible to unexpectedly high false-positive rates if those accurate predictions lie close to the decision boundary at 0 eV per atom above the convex hull. The benchmark results demonstrate that universal interatomic potentials have advanced sufficiently to effectively and cheaply pre-screen thermodynamic stable hypothetical materials in future expansions of high-throughput materials databases.

Riebesell, Janosh↗

A sensitive EUV Schwarzschild microscope for plasma studies with sub-micrometer resolution

We present an extreme ultraviolet (EUV) microscope using a Schwarzschild objective which is optimized for single-shot sub-micrometer imaging of laser-plasma targets. The microscope has been designed and constructed for imaging the scattering from an EUV-heated solid-density hydrogen jet. Here, imaging of a cryogenic hydrogen target was demonstrated using single pulses of the free-electron laser in Hamburg (FLASH) free-electron laser at a wavelength of 13.5 nm. In a single exposure, we observe a hydrogen jet with ice fragments with a spatial resolution in the sub-micrometer range. In situ EUV imaging is expected to enable novel experimental capabilities for warm dense matter studies of micrometer-sized samples in laser-plasma experiments.

42 ENGINEERING↗

Pentagonal prism spherical hohlraums for OMEGA

A new configuration is proposed for spherical hohlraums on OMEGA in which seven laser entrance holes (LEHs) are used—five around the equator and one at each pole [Farmer et al., Phys. Plasmas 26, 032701 (2019)]. This is known as the PEPR (pentagonal prism) hohlraum. A new view-factor code LORE is used to model the PEPR hohlraum and compare its performance with tetrahedral hohlraums shot on OMEGA. With optimization of beam pointings, the PEPR hohlraum produces a nonuniformity ranging from 1.1% (rms) at low albedos to 0.6% at high albedos. The tradeoffs between hohlraum-to-capsule ratio, uniformity, and background radiation temperature have been explored, and it has been shown that larger LEH radii on the poles can result in a modest improvement in uniformity. Here, the seven-hole PEPR hohlraum is well matched to the OMEGA symmetry and promises to provide insight into the performance of spherical hohlraums including octahedral (six-LEH) hohlraums.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

BioCARS: a synchrotron resource for time-resolved X-ray science

BioCARS, a NIH-supported national user facility for macromolecular time-resolved X-ray crystallography at the Advanced Photon Source (APS), has recently completed commissioning of an upgraded undulator-based beamline optimized for single-shot laser-pump X-ray-probe measurements with time resolution as short as 100 ps. The source consists of two in-line undulators with periods of 23 and 27 mm that together provide high-flux pink-beam capability at 12 keV as well as first-harmonic coverage from 6.8 to 19 keV. A high-heat-load chopper reduces the average power load on downstream components, thereby preserving the surface figure of a Kirkpatrick-Baez mirror system capable of focusing the X-ray beam to a spot size of 90 {micro}m horizontal by 20 {micro}m vertical. A high-speed chopper isolates single X-ray pulses at 1 kHz in both hybrid and 24-bunch modes of the APS storage ring. In hybrid mode each isolated X-ray pulse delivers up to {approx}4 x 10{sup 10} photons to the sample, thereby achieving a time-averaged flux approaching that of fourth-generation X-FEL sources. A new high-power picosecond laser system delivers pulses tunable over the wavelength range 450-2000 nm. These pulses are synchronized to the storage-ring RF clock with long-term stability better than 10 ps RMS. Monochromatic experimental capability with Biosafety Level 3 certification has been retained.

43 PARTICLE ACCELERATORS↗

Shot-by-shot Spectrum Model for Rod-pinch, Pulsed Radiography Machines

A simplified model of bremsstrahlung production is developed for determining the x-ray spectrum output of a rod-pinch radiography machine, on a shot-by-shot basis, using the measured voltage, V(t), and current, I(t). The motivation for this model is the need for an agile means of providing shot-by-shot spectrum prediction, from a laptop or desktop computer, for quantitative radiographic analysis. Simplifying assumptions are discussed, and the model is applied to the Cygnus rod-pinch machine. Output is compared to wedge transmission data for a series of radiographs from shots with identical target objects. Resulting model enables variation of parameters in real time, thus allowing for rapid optimization of the model across many shots. “Goodness of fit” is compared with output from LSP Particle-In-Cell code, as well as the Monte Carlo Neutron Propagation with Xrays (“MCNPX”) model codes, and is shown to provide an excellent predictive representation of the spectral output of the Cygnus machine. In conclusion, improvements to the model, specifically for application to other geometries, are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser-initiated p – 11 B fusion reactions in petawatt high-repetition-rate laser facilities

Driving of the nuclear fusion reaction p + 11 B → 3α + 8.7 MeV under laboratory conditions by interaction between high-power laser pulses and matter has become a popular field of research, owing to its numerous potential applications: as an alternative to deuterium–tritium for fusion energy production, astrophysics studies, and alpha-particle generation for medical treatment. One possible scheme for laser-driven p– 11 B reactions is to direct a beam of laser-accelerated protons onto a boron (B) sample (the so-called “pitcher-catcher” scheme). This technique has been successfully implemented on large high-energy lasers, yielding hundreds of joules per shot at low repetition. We present here a complementary approach, exploiting the high repetition rate of the VEGA III petawatt laser at CLPU (Spain), aiming at accumulating results from many interactions at much lower energy, to provide better control of the parameters and the statistics of the measurements. Despite a moderate energy per pulse, our experiment allowed exploration of the laser-driven fusion process with tens (up to hundreds) of laser shots. The experiment provided a clear signature of the reactions involved and of the fusion products, accumulated over many shots, leading to an improved optimization of the diagnostics for experimental campaigns of this type. In this paper, we discuss the effectiveness of laser-driven p– 11 B fusion in the pitcher–catcher scheme, at a high repetition rate, addressing the challenges of this experimental scheme and highlighting its critical aspects. Our proposed methodology allows evaluation of the performance of this scheme for laser-driven alpha particle production and can be adapted to high-repetition-rate laser facilities with higher energy and intensity.

Alpha particles↗

Holographic phase retrieval and reference design

Here, a general mathematical framework and recovery algorithm is introduced for the holographic phase retrieval problem. In this problem, which arises in holographic coherent diffraction imaging, a 'reference' portion of the signal to be recovered via phase retrieval is a priori known from experimental design. A generic formula is additionally derived for the expected recovery error when the measurement data is corrupted by Poisson shot noise. This facilitates an optimization perspective towards reference design and analysis. We employ this optimization perspective towards quantifying the performance of various reference choices.

97 MATHEMATICS AND COMPUTING↗

High-sensitivity three-mode optomechanical transducer

Three-mode optomechanical interactions have been predicted to allow the creation of very high sensitivity transducers in which very strong optical self-cooling and strong optomechanical quantum entanglement are predicted. Strong coupling is achieved by engineering a transducer in which both the pump laser and a single signal sideband frequency are resonantly enhanced. Here we demonstrate that very high sensitivity can be achieved in a very simple system consisting of a Fabry-Perot cavity with CO{sub 2} laser thermal tuning. We demonstrate a displacement sensitivity of {approx}1x10{sup -17} m/{radical}(Hz), which is sufficient to observe a thermally excited acoustic mode in a 5.6 kg sapphire mirror with a signal-to-noise ratio of more than 20 dB. It is shown that a measurement sensitivity of {approx}2x10{sup -20} m/{radical}(Hz) limited by the quantum shot noise is achievable with optimization of the cavity parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation of the Prompt Dose Environment in the NIF during High Yield Shots

The National Ignition Facility (NIF) at Lawrence Livermore National Laboratory is the world's largest and most energetic laser system for inertial confinement fusion. NIF is a 192-laser beam facility, capable of producing 1.8 MJ, 500 TW of ultraviolet light. The main laser systems are installed in two laser bays. Each laser bay delivers 96 beams into one of two switchyards. Sets of turning mirrors in each Switchyard (SY) redirect the beams into the Target Bay (TB). Additional sets of optics in the TB will align and focus the beams onto the target in the center of the Target Chamber (TC). The 192 beams enter the TC through 48 indirect-drive beam ports. Laser beams are then focused to enter a small metal can (hohlraum) held at the center of the TC creating thermal x-rays that heat the surface of the fusion capsule contained within. The Target Bay has a cylindrical design with an inner radius of 15.24 m, 1.83-m-thick concrete walls and 1.37-m-thick concrete roof. A total of 239 and 121 penetrations are present in the Target Bay and switchyard walls, respectively. Figure 1 shows the facility's layout. There are seven floor levels within the TB at elevations of -33'9'', -21'9'', -3'6'', 17'6'', 29'6'', 40'0'', and 50'6'' with respect to the ground level. The TC is positioned in the middle of the TB with its center at elevation of 23'0'' from the ground level. The NIF will routinely utilize deuterium-tritium (D-T) targets with up to 20 MJ yield per shot, and maximum annual yield of 1200 MJ. This summary focuses on analyzing the expected prompt dose environment during the NIF's high yield phase of operations. Previous publications evaluated the expected doses associated with lower yield phases of operation. During shots, the Target Bay, Switchyards, and Laser Bays are interlocked and unoccupied. On the other hand, Personnel can be present inside the Operations Support Building (OSB), the control room, and the visitor center during the shots. The radiation shielding has been optimized to meet the NIF radiological design goals and the Department of Energy (DOE) limits. The goal is to limit the maximum prompt dose in any potentially occupied area to less than 50 {mu}Sv per shot as well as limiting the annual dose to individuals in the occupied areas to less than 1 mSv.

61 RADIATION PROTECTION AND DOSIMETRY↗