Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “segmented scintillation detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Neutron detection efficiency of the Neutron dEtector with Xn Tracking (NEXT)

An efficient neutron detection system with good energy resolution is required to correctly characterize decays of neutron-rich nuclei where β-delayed neutron emission is a dominant decay mode. The Neutron dEtector with Xn Tracking (NEXT) has been designed to measure β-delayed neutron emitters. By segmenting the detector along the neutron flight path, NEXT reduces the associated uncertainties in neutron time-of-flight measurements, improving energy resolution while maintaining detection efficiency. Detector prototypes are comprised of optically separated segments of a neutron-gamma discriminating plastic scintillator coupled to position-sensitive photomultiplier tubes. In this work we discuss how the first performance studies of this detector showed that high intrinsic neutron detection efficiency could be achieved while retaining good energy resolution. The results from the efficiency measurements using neutrons from direct reactions are presented

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LLE Diagnostic Resource Team for Innovative Fusion Concepts (Final Report)

The LLE Diagnostic Resource Team for Innovative Fusion Concepts provided travelling neutron diagnostics, consultancy on neutron diagnostics, and consultancy on tritium handling to fusion companies. An existing neutron detector was recalibrated for low yields and two detectors were built based on designs proven on the Omega Laser Facility. The three detectors allow measurements over a wide range of yields (from 10 to 1E7 incident neutrons). The detectors were calibrated for DD neutrons on a dedicated OMEGA shot day. Neutron detectors from the company MIFTI were also calibrated on OMEGA. MIFTI is currently using their detectors and two of our detectors on staged Z-pinch experiments at UCSD. The Team acted as consultants for the development of a liquid scintillator array to detect neutrons from muon induced fusion by NK Labs. Segments of NK Labs’ detector were tested at the LLE using radioactive sources and a DD neutron generator. The Team also acted as consultants for the design of a tritium handling system for NK Labs. A new type of neutron spectrometer was designed and built, and has completed preliminary testing.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Compact single-shot soft X-ray photon spectrometer for free-electron laser diagnostics

The photon spectrum from free-electron laser (FEL) light sources offers valuable information in time-resolved experiments and machine optimization in the spectral and temporal domains. We have developed a compact single-shot photon spectrometer to diagnose soft X-ray spectra. The spectrometer consists of an array of off-axis Fresnel zone plates (FZP) that act as transmission-imaging gratings, a Ce:YAG scintillator, and a microscope objective to image the scintillation target onto a two-dimensional imaging detector. This spectrometer operates in segmented energy ranges which covers tens of electronvolts for each absorption edge associated with several atomic constituents: carbon, nitrogen, oxygen, and neon. The spectrometer’s performance is demonstrated at a repetition rate of 120 Hz, but our detection scheme can be easily extended to 200 kHz spectral collection by employing a fast complementary metal oxide semiconductor (CMOS) line-scan camera to detect the light from the scintillator. This compact photon spectrometer provides an opportunity for monitoring the spectrum downstream of an endstation in a limited space environment with sub-electronvolt energy resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Large area position sensitive detector for thermal neutrons

Large area thermal neutron detectors are applied in many fields including industrial imaging, nuclear safeguarding, neutron scattering, and fundamental science. Historically, these detectors were based on 3 He gas proportional counters despite the limitations of 3 He detectors such as high cost, limited supply, non-uniform spatial resolution, and depth of absorption problems. Two alternatives to 3 He detectors are 6 Li-loaded glass scintillators, and powdered ZnS(Ag) scintillators mixed with 6LiF neutron converters. The 6 LiF/ZnS(Ag) scintillator has advantages over 6 Li glass as it is less expensive and can be produced in larger areas, although its self-absorption presents a problem. In this work, we developed a large area thermal neutron detector based on 6 LiF/ZnS(Ag) scintillator coupled with wavelength shifting fibers. The detector uses resistive charge divider-based position encoding. We further modified and improved the method by 2D segmentation of the detector using modular multichannel readout electronics. This segmentation approach allows for a combination of large detector area, improved spatial resolution, and increased count rate. Furthermore, spatial resolution can be variable across the detector area by adjusting the segment size.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of $\nu_\mu$ CC Interactions With Two-Proton Final State in MINERvA

This dissertation presents a measurement of charged–current (CC) muon–neutrino interactions with exactly two protons and no pions in the final state (CC~$2p\,0\pi$), using data collected by the MINERvA detector in the NuMI medium–energy beam at Fermilab. Such two–proton topologies are a sensitive probe of nuclear dynamics in the few–GeV regime, including multi–nucleon correlations (npnh, notably $2p2h$) and intranuclear final–state interactions (FSI) such as pion absorption and nucleon rescattering. A precise experimental characterization of these processes is essential both for neutrino–interaction theory and for reducing systematic uncertainties in oscillation experiments that rely on accurate modeling of neutrino–nucleus interactions. Events are selected by requiring a $\nu_\mu$ CC interaction with a reconstructed $\mu^-$ and two proton tracks originating from a common vertex in MINERvA’s finely segmented scintillator tracker, with no reconstructed mesons. Muon charge and momentum are constrained by matching to the MINOS Near Detector, while proton identification exploits energy–loss profiles and stopping–proton features. Backgrounds from pion–producing channels that enter the signal region through FSI or reconstruction effects are constrained with data–driven sidebands (Michel–electron and isolated–cluster “blob” samples) and tuned via a simultaneous fit across signal and sideband regions. To correct detector resolution and acceptance effects, the analysis employs iterative Bayesian unfolding with extensive validation: statistical pseudo–experiments, and robustness checks against generator systematic “universes” and additional strong shape warps. Single–differential cross sections are reported for three observables tailored to the two–proton final state: the opening–angle cosine $\cos\!\left(\theta_{pp}\right)$, the leading–proton momentum, and the subleading–proton momentum. Systematic uncertainties include contributions from neutrino flux, interaction modeling (e.g., npnh and resonance parameters, pion FSI), and detector response (calibration, reconstruction efficiencies). The resulting distributions provide targeted constraints on the interplay of multi–nucleon dynamics and FSI that shape CC~$2p\,0\pi$ final states on hydrocarbon. Comparisons to modern GENIE–based simulations highlight kinematic regions where model components require refinement. These measurements thus inform generator tuning and improve the reliability of neutrino–energy reconstruction strategies for current and future long–baseline oscillation programs.

Syrotenko, Vladyslav S. [Tufts U.]↗

Long-length Scintillating Fibers for Nuclear Geological Repositories

This research focuses on the usage of plastic scintillating fibers as ruggedized detectors in long-length sections coupled to long-length standard optical fiber segments for the purpose of radiation detection and monitoring. This technology addresses a need for monitoring radiation in difficult-to-access or inaccessible areas, such as monitoring: radioactive waste within geological repositories, nuclear material storage facilities, spent fuel dry storage areas, inaccessible areas within nuclear facilities including reactors and reprocessing facilities, decommissioning of nuclear facilities, and other similar areas. The fiber can be placed along the tunnels of a geological repository to monitor the radiation field along its length. This can detect an increase of radiation due to movement, leakage, or unexpected opening of the containers, as well as decrease in the radiation due to removal of material. These capabilities have been demonstrated at INL’s Radioactive Scrap Waste Facility by successfully detecting the removal of an interim storage containers from the storage area. The poster focuses on explaining the technology and its capability in monitoring deep geological repositories (DGRs), especially in the domain of safety and international safeguards. As more countries consider the development of DGRs, technologies such as the one being presented can help establish continuity of knowledge of the material, maintain public confidence, and ensure safe operation of the facility. Furthermore, the poster looks at the future steps of the technology and its potential role in the international safeguards regime.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

Assembly and Testing of Scintillator Tile Modules for the CMS High-Granularity Calorimeter Upgrade

The High-Granularity Calorimeter (HGCAL), part of the upgrade to the Compact Muon Solenoid (CMS) experiment, employs silicon and scintillator tile modules in the endcaps to maintain detector performance during the High-Luminosity Large Hadron Collider (HL-LHC) era, scheduled to operate from 2030 to 2040. The upgraded calorimeter will provide highly segmented three-dimensional imaging, energy measurements, and precise timing for particle shower reconstruction. Approximately half of the HGCal plastic scintillator tile modules (1,834 total) will be assembled at Fermilab using an automated pick-and-place (PnP) machine. Following assembly, each tile module undergoes quality control (QC) procedures such as electrical validation, thermal testing, and physics validation using cosmic rays. This poster/talk presents the QC procedures and results from the tile module production in 2026, demonstrating the performance and quality of the assembled tile modules.

Bazimya, Jean Luc [Grambling State U.]↗

A monolithic antineutrino detector for non-intrusive reactor monitoring

Recent advances in organic detection media have found applications in reactor antineutrino physics. One example is the Precision Oscillation and Spectrum Experiment (PROSPECT), which leveraged pulse-shape sensitivity to enable a successful surface deployment at the High Flux Isotope Reactor (HFIR), achieving a signal to background of 4:1. PROSPECT utilized almost 4 tonnes of 6 Li-doped pulse-shape sensitive liquid scintillator in a two-dimensional segmented array. It used a combination of pulse-shape sensitivity and position sensitivity via segmentation to reduce the most prominent form of correlated background for surface detectors — cosmogenic fast neutrons. These new liquids may enable detector designs that bring additional tools for reducing backgrounds while reducing engineering complexity. In this paper, we present an investigation into a detector design that exploits properties of these liquids by maximizing spectral and pulse-shape sensitivity via highly efficient photon detection. The detector utilizes photomultiplier tubes (PMTs) placed at the top and bottom of a right cylinder, with highly reflective white walls. This design sacrifices some position sensitivity for maximal photon efficiency. In conclusion, the design choice has consequences for the identification of the background and antineutrino sensitivity, which we examine.

Pulse shape↗

GENESIS: Gamma Energy Neutron Energy Spectrometer for Inelastic Scattering

Improved neutron inelastic scattering cross section data are needed to inform integral benchmark studies and advance applications in a wide variety of areas including nuclear energy, stockpile stewardship, nonproliferation, and space exploration. Neutron inelastic scattering also serves as a non-selective probe of low-lying nuclear structure. To help meet these needs, the Gamma Energy Neutron Energy Spectrometer for Inelastic Scattering (GENESIS) was constructed at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. This array couples high-resolution γ-ray detectors and fast neutron detectors to achieve single and coincident n/γ detection over a broad energy range. The current configuration of the array includes 26 organic liquid scintillators and four high-purity germanium detectors (two single-crystal and two four-crystal CLOVER detectors with two-fold segmentation). The array was constructed with minimal supporting material and designed to cover a wide range of secondary particle angles and energies with limited inter-element scattering. Data acquisition is accomplished using Mesytec MDPP-16 multi-channel high-resolution digital pulse processing modules. The array characteristics, including γ-ray and neutron energy resolution, timing resolution, and detection efficiency were measured and used to validate a Geant4 model of the array. Furthermore, the primary sources of neutron background and the uncertainties in the determination of incident and secondary neutron energy were assessed. GENESIS provides a new capability to address nuclear data needs and facilitates the advancement of a wide range of nuclear applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Strip-based Scintillation Detector for Dual-readout High-granularity Calorimetry

New calorimeter technology is being developed for future collider experiments. We are developing a calorimeter that integrates two technologies, a high-granularity calorimeter and a dual-readout calorimeter, and has high time resolution at a picosecond level. The proposed calorimeter is a sampling calorimeter based on scintillation and Cherenkov detectors with high-granularity readout. The Cherenkov detector has a picosecond level time resolution. For the high-granularity scintillation detector, scintillator strips of 300mm × 30mm ×3mm-thick are aligned horizontally and vertically to realize an effective 30mm-square-cell segmentation. Prototype strips with different designs and scintillator materials were tested to compare the performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multiplicity trigger detector for the S π RIT experiment

A multiplicity trigger detector (MTD) was developed for the SπRIT experiment that aims to probe the high- density symmetry energy via heavy-ion collisions (HICs). The MTD is designed to measure the charged-particle multiplicity in HICs to provide a trigger signal that can be used to select high-multiplicity events induced by central collisions. The MTD consists of two side-walls segmented into 30 plastic scintillation paddles, each equipped with a multi-pixel photon counter. A custom board with EASIROC front-end ASIC is used as readout electronics. A multiplicity logic signal is generated by an on-board FPGA that processes the discriminated signals from EASIROCs. The overall latency of the whole detector system for outputting the trigger is less than 100 ns, including 52 ns of electronics latency for processing the signals. During the measurement of 112 Sn + 124 Sn reactions at an incident energy of 270 MeV/nucleon, the minimum multiplicity threshold of the MTD was set to 4, where the overall trigger efficiency was obtained to be about 39 % for inclusive nuclear reactions. Furthermore, a simulation study with a numerical calculation of HICs found that the central collisions of impact parameters of less than 4 fm can be triggered with a high efficiency of more than 95 % by the experimental trigger condition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electromagnetic energy calibration of the SoLid detector with horizontal muons

SoLid is a neutrino experiment at very-short baselinesearching for active-to-sterile oscillations of reactorantineutrinos. The detection principle is based on the pairing oftwo types of solid scintillators: polyvinyl toluene and $^{6}$Li:ZnS(Ag), which is a new technology used in this field ofPhysics. In addition to good neutron-gamma discrimination, thissetup allows the detector to be highly segmented; the basicdetection unit is a 5 cm cube. High segmentation provides numerousadvantages including precise localisation of the Inverse Beta Decay(IBD) products, the derivation of an antineutrino energy estimatorbased on the isolated positron energy, and a powerful backgroundreduction tool that relies on the topological signature of thesignal. Finally, the system is read out by a network ofwavelength-shifting fibres coupled to photosensors. A relativeelectromagnetic calibration is performed with horizontal cosmicmuons. This source poses the simplest calibration problem in which asingle detection unit is involved. In addition, large muon energydeposits allow us to perform a calibration at the most detailedlevel (i.e. per fibre) and to accurately define the fraction ofenergy escaping to neighbouring detection cells. A statisticalprecision at the sub-percent level is reached. The paper alsodiscusses two methods to calibrate the absolute energy scale andpresents their implementation and results. The first method relieson horizontal muons, though the precision is limited to around 10%because of the uncertainty in the energy distribution of suchmuons. A novel, alternative method based on the radioactiveamericium-beryllium source is proposed. It takes advantage of theelectron-positron pair-production process and provides a calibrationpoint at 3.4 MeV (i.e. in the core of the IBD positronspectrum). The paper is concluded with various cross-check includinga determination of the energy spectrum of the standard cosmogenicbackground candle: $^{12}$B.

Abreu, Y. [Antwerp U.]↗

Development of High-Granularity Dual-Readout Calorimetry with psec Timing

Dual-readout and particle flow algorithm (PFA) are technologies proposed for precise jet energy measurement in future colliders. While PFA requires highly granular calorimeters, dual-readout has mainly been used with fiber-based calorimeters that do not have highly segmented capabilities. It is still non-trivial to combine these two technologies in one calorimeter system because of the use of fibers in most of the dualreadout calorimeters, which is not compatible with the high granularity requirement of PFA technologies. The aim of this study is to develop a novel calorimetry that combines dual-readout and PFA by adopting a highly segmented tile-based configuration. This paper compares the improvement of energy resolution using dual-readout approach across several configurations of highly granular hadron calorimeters through simulation. Results indicate that setups with fine sampling and close placement of scintillators and Cherenkov detectors improve dual-readout performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Operation of a Modular 3D-Pixelated Liquid Argon Time-Projection Chamber in a Neutrino Beam

The 2x2 Demonstrator, a prototype for the Deep Underground Neutrino Experiment (DUNE) liquid argon (LAr) Near Detector, was exposed to the Neutrinos from the Main Injector (NuMI) neutrino beam at Fermi National Accelerator Laboratory (Fermilab). This detector is a prototype of a new modular design for a liquid argon time-projection chamber (LArTPC), comprising a two-by-two array of four modules, each further segmented into two optically isolated LArTPCs. The 2x2 Demonstrator features a number of pioneering technologies, including a low-profile resistive field shell to establish drift fields, native 3D ionization pixelated imaging, and a high-coverage dielectric light readout system. The 2.4-tonne active mass detector is flanked upstream and downstream by supplemental solid-scintillator tracking planes, repurposed from the MINERvA experiment, which track ionizing particles exiting the argon volume. The antineutrino beam data collected by the detector over a 4.5 day period in 2024 include over 30,000 neutrino interactions in the LAr active volume—the first neutrino interactions reported by a DUNE detector prototype. During its physics-quality run, the 2x2 Demonstrator operated at a nominal drift field of 500 V/cm and maintained good LAr purity, with a stable electron lifetime of approximately 1.25 ms. This paper describes the detector and supporting systems, summarizes the installation and commissioning, and presents the initial validation of collected NuMI beam and off-beam self-triggers. In addition, it highlights observed interactions in the detector volume, including candidate muon antineutrino events.

47 OTHER INSTRUMENTATION↗

Search for very-short-baseline oscillations of reactor antineutrinos with the SoLid detector

In this paper we report the first scientific result based on antineutrinos emitted from the BR2 reactor at SCK CEN. The SoLid experiment uses a novel type of highly granular detector whose basic detection unit combines two scintillators, polyvinyl toluene (PVT) and Li 6 F : ZnS ( Ag ) , to measure antineutrinos via their inverse- β -decay products. An advantage of PVT is its highly linear response as a function of deposited particle energy. The full-scale detector comprises 12 800 voxels and operates over a very short 6.3–8.9 m baseline from the reactor core. The detector segmentation and its three-dimensional imaging capabilities facilitate the extraction of the positron energy from the rest of the visible energy, allowing the latter to be utilized for signal-background discrimination. We present a result obtained from 280 reactor-on days (55 MW mean power) and 172 reactor-off days, respectively, of live data taking. A total of 29 479 ± 603 (stat) antineutrino candidates have been selected, corresponding to an average rate of 105 events per day and a signal-to-background ratio of 0.27. A search for disappearance of antineutrinos to a sterile state has been conducted using complementary model-dependent frequentist and Bayesian fits, providing constraints on the allowed region of the reactor antineutrino anomaly.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Automated integration gate selection for Gaussian mixture model pulse shape discrimination

Pulse shapes differ between neutron and gamma particles when measured with detector devices employing pulse shape discriminating (PSD) scintillators. Digitized waveforms can be used in detection systems to perform pulse shape discrimination for this application. Prior Gaussian Mixture Model (GMM) methods require access to the pulse full-waveform. Reducing the waveform to a smaller set of combined samples reduces computational cost while affecting PSD performance. In this work, we develop a method for selecting the best performing combination of integration gates, or contiguous summed segments of the digitized pulse for PSD. The method uses a discrimination score based on the GMM PSD approach. Furthermore, the final selection is performed using Bayesian Optimization. PSD detection results are compared with varying numbers of selected gates on time-of-flight (TOF) data. This method can be used to fully automate the selection of gates in an unsupervised (without ground truth labels) setting.

42 ENGINEERING↗

Performance of the CMS High Granularity Calorimeter prototype to charged pion beams of 20–300 GeV/c

The upgrade of the CMS experiment for the high luminosity operation of the LHC comprises the replacement of the current endcap calorimeter by a high granularity sampling calorimeter (HGCAL). The electromagnetic section of the HGCAL is based on silicon sensors interspersed between lead and copper (or copper tungsten) absorbers. The hadronic section uses layers of stainless steel as an absorbing medium and silicon sensors as an active medium in the regions of high radiation exposure, and scintillator tiles directly read out by silicon photomultipliers in the remaining regions. As part of the development of the detector and its readout electronic components, a section of a silicon-based HGCAL prototype detector along with a section of the CALICE AHCAL prototype was exposed to muons, electrons and charged pions in beam test experiments at the H2 beamline at the CERN SPS in October 2018. The AHCAL uses the same technology as foreseen for the HGCAL but with much finer longitudinal segmentation. The performance of the calorimeters in terms of energy response and resolution, longitudinal and transverse shower profiles is studied using negatively charged pions, and is compared to GEANT4 predictions. This is the first report summarizing results of hadronic showers measured by the HGCAL prototype using beam test data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improving ICARUS track reconstruction algorithms

The ICARUS experiment is part of the Short-Baseline Neutrino program at Fermilab. Its primary objective is to explore the possible existence of sterile neutrinos in the O(1 eV) mass range and to clarify the anomalies observed in the Liquid Scintillator Neutrino Detector and MiniBooNE experiments. The ICARUS-T600 detector is a Liquid Argon Time Projection Chamber, capable of producing high-resolution 3D images and precise calorimetric measurements of ionizing particles. This technology allows for a detailed study of neutrino interactions across a broad energy range, from a few keV to several hundred GeV. The track reconstruction is achieved through a software framework that applies a series of pattern recognition algorithms, transforming raw detector signals into fully reconstructed event topologies. This process involves identifying interaction vertices, particle tracks, and electromagnetic showers within the TPC. However, in certain cases, these algorithms may mistakenly break a single particle track into several shorter segments, interpreting each as a distinct particle. Since track length is used to estimate the particle's energy, such fragmentation can result in an energy underestimation of several hundred MeV. Furthermore, when a track is split into multiple segments, the particle identification (which relies on analyzing the energy loss as a function of the residual range) may fail, potentially leading to the loss of the entire event. To mitigate this problem, we have developed a dedicated algorithm designed to identify and reconnect (“stitch”) the tracks that were erroneously divided into multiple segments.

Ricci, Alessandro Maria [Pisa U.; INFN, Pisa] (ORC↗