Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “resistivity measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Evidence of Superconductivity in Electrical Resistance Measurements of Hydrides Under High Pressure

In the standard van der Pauw four-probe configuration commonly used for electrical resistance measurements, including those of hydrogen-rich samples at high pressures, the application of electrical current through one pair of leads while measuring voltage difference across another pair is a fundamental practice (see the inset in Fig. 1c). In the scenario described in Ref. [5], where electrical resistance vanishes due to disconnection between current and voltage probes or due to an onset of giant magnetoresistance in parts of the sample, it is crucial to consider the implications across different probe orientations: while one orientation may indeed result in vanishing electrical resistance, a divergence of the electrical resistance towards infinity will be observed in an alternative orientation where the applied current pattern is rotated a quarter turn (see the scheme on the inset in Fig. 1c). It is imperative to acknowledge that experimental data encompassing all possible probe orientations are essential for eliminating artifacts and assessing sample homogeneity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Proposed Modifications to Engineering Design Guidelines Related to Resistivity Measurements and Spacecraft Charging

A key parameter in modeling differential spacecraft charging is the resistivity of insulating materials. This determines how charge will accumulate and redistribute across the spacecraft, as well as the time scale for charge transport and dissipation. Existing spacecraft charging guidelines recommend use of tests and imported resistivity data from handbooks that are based principally upon ASTM methods that are more applicable to classical ground conditions and designed for problems associated with power loss through the dielectric, than for how long charge can be stored on an insulator. These data have been found to underestimate charging effects by one to four orders of magnitude for spacecraft charging applications. A review is presented of methods to measure the resistive of highly insulating materials, including the electrometer-resistance method, the electrometer-constant voltage method, the voltage rate-of-change method and the charge storage method. This is based on joint experimental studies conducted at NASA Jet Propulsion Laboratory and Utah State University to investigate the charge storage method and its relation to spacecraft charging. The different methods are found to be appropriate for different resistivity ranges and for different charging circumstances. A simple physics-based model of these methods allows separation of the polarization current and dark current components from long duration measurements of resistivity over day- to month-long time scales. Model parameters are directly related to the magnitude of charge transfer and storage and the rate of charge transport. The model largely explains the observed differences in resistivity found using the different methods and provides a framework for recommendations for the appropriate test method for spacecraft materials with different resistivities and applications. The proposed changes to the existing engineering guidelines are intended to provide design engineers more appropriate methods for consideration and measurements of resistivity for many typical spacecraft charging scenarios.

Dennison, J. R.↗

Screening candidate supplementary cementitious materials under standard and accelerated curing through time-series surface resistivity measurements and change-point detection

Time-series surface resistivity (SR) measurements are evaluated as an indicator of pozzolanicity in concretes containing 13 materials of both known and unknown pozzolanicity, under standard and accelerated curing conditions, and the results were validated against portlandite consumption obtained through thermogravimetric analysis. Change-point detection (CPD) analysis is applied to the data to provide a rigorous indicator of hydration age of the onset and rate of the pozzolanic reaction, if occurring. The SR measurements were able to capture the onset of the pozzolanic reactions in concretes curing at elevated temperature regimes, which allows determination of pozzolanicity weeks earlier than at standard curing temperatures. Using CPD along with slope analysis allows a comprehensive analysis of a material's reactivity and determination of pozzolanicity in as quickly as two days. Time-series SR measurements at elevated curing conditions, along with limits on material composition, are recommended for determination of pozzolanic reactivity in novel or variable materials.

36 MATERIALS SCIENCE↗

Method for contact resistivity measurements on photovoltaic cells and cell adapted for such measurement

A method is disclosed for scribing at least three grid contacts of a photovoltaic cell to electrically isolate them from the grid contact pattern used to collect solar current generated by the cell, and using the scribed segments for determining parameters of the cell by a combination of contact end resistance (CER) measurements using a minimum of three equally or unequally spaced lines, and transmission line modal (TLM) measurements using a minimum of four unequally spaced lines. TLM measurements may be used to determine sheet resistance under the contact, R.sub.sk, while CER measurements are used to determine contact resistivity, .rho..sub.c, from a nomograph of contact resistivity as a function of contact end resistance and sheet resistivity under the contact. In some cases, such as the case of silicon photovoltaic cells, sheet resistivity under the contact may be assumed to be equal to the known sheet resistance, R.sub.s, of the semiconductor material, thereby obviating the need for TLM measurements to determine R.sub.sk.

Burger, Dale R.↗

Nondestructive evaluation of printed wiring boards by microhm resistance measurements

Application of the microhm measuring circuit to measurement of plated-through hole resistances, when combined with appropriate probes, provides data that can be related to the quality of copper plating on printed wiring boards. Acceptance limits can be established and continuous inspection performed, with plating defects causing abnormal readings.

Stiefeld, B.↗

Temperature dependent striction effect in a single crystalline Nd 2 Fe 14 B revealed using a novel high temperature resistivity measurement technique

In this work, we studied the temperature dependence of resistivity in a single crystalline Nd 2 Fe 14 B using a newly developed high temperature probe. This novel probe employs mechanical pin connectors instead of conducting glue/paste. From warming and cooling curves, the Curie temperature was consistently measured around T c = 580 K. In addition, anomalous discrete jumps were found only in cooling curves between 400 and 500 K, but not shown in warming curves. More interestingly, when the jumps occurred during cooling, the resistivity was increased. This phenomenon could possibly be due to a temperature dependent striction effect induced by the re-orientation of magnetic domains well below the Curie temperature. Further microscopic study is needed to confirm this effect.

permanent magnet↗

Estimating Permafrost Distribution Using Co‐Located Temperature and Electrical Resistivity Measurements

Abstract Assessing the lateral and vertical extent of permafrost is critical to understanding the fate of Arctic ecosystems under climate change. Yet, direct measurements of permafrost distribution and temperature are often limited to a small number of borehole locations. Here, we assess the use of co‐located shallow temperature and electrical resistivity tomography (ERT) measurements to estimate at high‐resolution the distribution of permafrost in three watersheds underlain by discontinuous permafrost. Synthetic modeling shows that co‐located temperature and ERT measurements allow for supervised classification schemes that provide 60% higher accuracy compared to unsupervised methods. Linking resistivity and size of the identified permafrost bodies to surface observations, we show that tall vegetation (>0.5 m) and gentle slopes (<15°) are related to warmer and smaller permafrost bodies, and a more frequent occurrence of taliks.

54 ENVIRONMENTAL SCIENCES↗

Air resistance measurements on actual airplane parts

For the calculation of the parasite resistance of an airplane, a knowledge of the resistance of the individual structural and accessory parts is necessary. The most reliable basis for this is given by tests with actual airplane parts at airspeeds which occur in practice. The data given here relate to the landing gear of a Siemanms-Schuckert DI airplane; the landing gear of a 'Luftfahrzeug-Gesellschaft' airplane (type Roland Dlla); landing gear of a 'Flugzeugbau Friedrichshafen' G airplane; a machine gun, and the exhaust manifold of a 269 HP engine.

Weiselsberger, C↗

Co-located temperature and electrical resistivity measurements for permafrost mapping, Teller 27, Teller 47 and Kougarok 64, Seward Peninsula, Alaska, late summers of 2018, 2019, 2021, and 2022

This data set contains co-located shallow soil (0.8m below ground level) and electrical resistivity at various depth extracted from Electrical Resistivity Tomography (ERT) measurements. Data were acquired at three watersheds on the southern Seward Peninsula during the late summers of 2018, 2019, 2021, and 2022. The three watersheds are located along the Nome-Teller Highway at mile markers 27 and 47, and along Kougarok Road mile marker 64. The co-located temperature and electrical resistivity data were used to (1) map the spatial extend of near surface permafrost, and (2) for supervised classification of permafrost bodies. This dataset contains .csv, .txt, .srv files and flmd reporting format with data dictionary. Find information about the .srv files at "https://e4d-userguide.pnnl.gov/e4d_guide/elec/e4d_e4d-survey.html". The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Tape-in-tape-out (TITO): a new approach for in-situ contact resistance measurements in high temperature superconducting CORC® cables

One of the ongoing development challenges with ReBCO high-temperature superconducting (HTS) cables is normal zone initiation and local heating, which is associated with over-critical current flowing through and around local performance reductions in individual tapes. Although inter-tape contact resistances are well-reported for individual tapes and HTS cables, these measurements are a challenge in CORC® cables as current percolates through much of the cable. In this work, developments in tape-in-tape-out (TITO) automated individual tape powering experiments are presented, and a simplified modeling approach for current percolation in CORC® cables is developed. An optimization is formulated to fit the model parameters to a large set of TITO experiments on a single cable, allowing the layer-dependent inter-tape contact resistance to be extracted. Measurements are presented and discussed for a straight CORC® cable and a cable bent to a 152 mm and 76 mm radius. The approach provides both quantitative insight and facilitates better understanding of current sharing phenomena in HTS cables.

Teyber, Reed↗

Inflight resistance measurement on high-T(sub c) superconducting thin films exposed to orbital atomic oxygen on CONCAP-2 (STS-46)

In 1992, UAH (University of Alabama in Huntsville) conducted a unique experiment on STS-46 in which YBa2Cu3O7 (commonly known as '1-2-3' superconductor) high-T(c) superconducting thin film samples prepared at three different laboratories were exposed to 5 eV atomic oxygen in low Earth orbit on the ambient and 320 C hot plate during the first flight of the CONCAP-2 (Complex Autonomous Payload) experiment carrier. The resistance of the thin films was measured in flight during the atomic oxygen exposure and heating cycle. Superconducting properties were measured in the laboratory before and after the flight by the individual experimenters. Films with good superconducting properties, and which were exposed to the oxygen flux, survived the flight including those heated to 320 C (600 K) with properties essentially unchanged, while other samples which were heated but not exposed to oxygen were degraded. The properties of other flight controls held at ambient temperature appear unchanged and indistinguishable from those of ground controls, whether exposed to oxygen or not.

Gregory, J. C.↗

Dynamics of graphite fiber intercalation: In situ resistivity measurements with a four point probe

The dynamics of ferric chloride intercalation of single graphite fibers were studied, in situ, using a four point dc bridge. Measurements before, during and after the intercalation showed that the intercalation occurred within minutes at 200 C. Changes in fiber resistivity after exposure to air suggested hydration of the graphite intercalation compound. Deintercalation of the ferric chloride was initiated at temperatures in excess of 400 C. cycling the intercalant into and out of the graphite fiber gave no improvements in fiber resistivity. The activation energy of the ferric chloride intercalation reaction was found to be 17 + or - 4 kcal/mol 1 consistent with the concept of a preliminary nucleation step in the intercalation reaction.

Jaworske, D. A.↗

New flange correction formula applied to interfacial resistance measurements of ohmic contacts to GaAs

A quasi-two-dimensional analytical model is developed to account for vertical and horizontal current flow in and adjacent to a square ohmic contact between a metal and a thin semiconducting strip which is wider than the contact. The model includes side taps to the contact area for voltage probing and relates the 'apparent' interfacial resistivity to the (true) interfacial resistivity, the sheet resistance of the semiconducting layer, the contact size, and the width of the 'flange' around the contact. This relation is checked against numerical simulations. With the help of the model, interfacial resistivities of ohmic contacts to GaAs were extracted and found independent of contact size in the range of 1.5-10 microns.

Lieneweg, Udo↗

Influence of Fiber Content, Thermal Cycles and Creep on Electrical Resistivity Measurements of SiCf/SiC Minicomposites

Fiber-reinforced Ceramic Matrix Composites (CMCs) are currently being used in high-temperature applications such as jet engine components. In such extreme environment applications, materials are exposed to many mechanical and thermal loading cycles during the life of the component. This exposure can degrade the component, and thus, components need to be monitored and inspected during service. The electrical resistivity nondestructive evaluation technique has been shown to be very sensitive to damage in CMCs, and although its performance is highly dependent on temperature, this temperature-dependence is still not well understood. Therefore, this current study aims to establish the influence of thermal cycles, creep, CVI-SiC matrix cracks and fiber volume fraction on the electrical resistance of Hi Nicalon and Hi-Nicalon Type S SiC fiber-reinforced minicomposites with BN interphases. Minicomposites with 97% CVI-SiC matrix volume fraction were used to characterize the electrical resistivity of the CVI-SiC matrix. Next, models were constructed to calculate fiber resistivity and onset and evolution of damage during tensile testing at room-temperature. The thermal cycles were achieved by heating as-received and precracked specimens to 1200°C and then cooling them to room temperature, with or without applied stress on fibers.

creep↗

A reevaluation of the interrupter technique for airway resistance measurement

An attempt was made to obtain a better insight into the actual transient response of airway opening pressure (Pao) following rapid occlusion. With this knowledge it was hoped to be able to clarify the reason for the overestimations found by other investigators, and possibly to obtain a more accurate method of estimating alveolar pressure just prior to interruption. This would result in an improved method for estimating airway resistance. Use of an extrapolation method was found to provide an improved correlation between resistances determined by the interruptor technique and those found by the plethysmograph in normal subjects.

Jackson, A. C.↗