Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power modeling and estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

The DESI DR1 peculiar velocity survey: Growth rate measurements from the galaxy power spectrum

The large-scale structure of the Universe and its evolution encapsulate a wealth of cosmological information. A powerful means of unlocking this knowledge lies in measuring the auto-power spectrum and/or the cross-power spectrum of the galaxy density and momentum fields, followed by the estimation of cosmological parameters based on these spectrum measurements. In this study, we generalize the cross-power spectrum model to accommodate scenarios in which the density and momentum fields are derived from distinct galaxy surveys. The growth rate of the large-scale structures of the Universe, commonly represented as fσ 8 , was extracted by jointly fitting the monopole and quadrupole moments of the auto-density power spectrum, the monopole of the auto-momentum power spectrum, and the dipole of the cross-power spectrum. Our estimators, theoretical models, and parameter-fitting framework were tested using mocks, confirming their robustness and accuracy in retrieving the fiducial growth rate from simulation. These techniques were then applied to analyse the power spectrum of the DESI Bright Galaxy Survey and Peculiar Velocity Survey. The fit result of the growth rate is fσ8 = 0.440$^{+0.080}_{−0.096}$ at effective redshift zeff = 0.07. By synthesizing the fitting outcomes from correlation functions, maximum likelihood estimation, and the power spectrum, a consensus value is yielded of fσ 8 (z eff = 0.07) = 0.450$^{+0.055}_{−0.055}$, and correspondingly we obtain γ = 0.580$^{+0.110}_{−0.110}$, Ω m = 0.301$^{+0.011}_{−0.011}$, and σ 8 = 0.834$^{+0.032}_{−0.032}$. The measured fσ8 and γ are consistent with the prediction of the Λ cold dark matter model and general relativity.

79 ASTRONOMY AND ASTROPHYSICS↗

The DESI DR1 Peculiar Velocity Survey: Growth Rate Measurements from the Galaxy Power Spectrum

The large-scale structure of the Universe and its evolution encapsulate a wealth of cosmological information. A powerful means of unlocking this knowledge lies in measuring the auto-power spectrum and/or the cross-power spectrum of the galaxy density and momentum fields, followed by the estimation of cosmological parameters based on these spectrum measurements. In this study, we generalize the cross-power spectrum model to accommodate scenarios where the density and momentum fields are derived from distinct galaxy surveys. The growth rate of the large-scale structures of the Universe, commonly represented as $fσ_8$, is extracted by jointly fitting the monopole and quadrupole moments of the auto-density power spectrum, the monopole of the auto-momentum power spectrum, and the dipole of the cross-power spectrum. Our estimators, theoretical models and parameter-fitting framework have been tested using mocks, confirming their robustness and accuracy in retrieving the fiducial growth rate from simulation. These techniques are then applied to analyze the power spectrum of the DESI Bright Galaxy Survey and Peculiar Velocity Survey, and the fit result of the growth rate is $fσ_8=0.440^{+0.080}_{-0.096}$ at effective redshift $z_{\rm eff}=0.07$. By synthesizing the fitting outcomes from correlation functions, maximum likelihood estimation and power spectrum, yields a consensus value of $fσ_8(z_{\rm eff}=0.07) = 0.450 ^{+0.055}_{-0.055}$, and correspondingly we obtain $γ=0.580^{+0.110}_{-0.110}$, $Ω_\mathrm{m}=0.301^{+0.011}_{-0.011}$ and $σ_8=0.834^{+0.032}_{-0.032}$. The measured $fσ_8$ and $γ$ are consistent with the prediction of the $Λ$ Cold Dark Matter Model and General Relativity.

Qin, F. [Marseille, CPPM] (ORCID:0000000179507864)↗

Social vulnerability and power loss mitigation: A case study of Puerto Rico

The increasing occurrence of extreme weather events urges us to reevaluate the resiliency and vulnerability aspects of our most critical infrastructures — such as power grids — as their failures result in both economic loss and severe human hardship. Seen through the lens of alleviating human suffering, it is crucial to be able to identify critical system components of the infrastructure for targeted hardening given resource constraints. This effort is of particular importance in islanded areas such as Puerto Rico where hurricanes are frequent and resources are limited, and where the spatially diverse effects of power loss on human suffering are all the more severe. Recent studies on evaluating infrastructure networks during extreme weather events have taken a simulation based approach that incorporates a variety of component models, such as weather realizations, topological network models, fragility models, and power flow models to estimate expected loss of service. Here, in this work, we expand such a Component Based Event Simulation (CBES) methodology proposed in the literature and integrate it with a social vulnerability modeling component. This paradigm-advancing approach of synthesizing the cutting edge capability of power network modeling and the social impacts of the power transmission network failure is demonstrated for the island of Puerto Rico. Our work exemplifies the efficacy of this integrated modeling framework in developing a decision metric for targeted transmission line hardening.

24 POWER TRANSMISSION AND DISTRIBUTION↗

AOI 3 Life Modelling of Critical Steam Cycle Components in Coal-Fueled Power Plants

Microstructural damage accumulation models have been used to produce calibrated life estimation models for a DR22/P22 steel wye-block welds, and a Jethete stainless steel turbine blade (bucket). The calibrated life estimation models will aid the power plant operator in determining optimal maintenance and operation schedules based upon historical operational data as well as current, or future operation schemes. The impact of this project will enable existing coal-fueled power plants to operate safely for longer periods of time and at higher efficiencies, thereby reducing the economic and environmental impact of the existing coal power plant fleet. Testing, characterization, and modelling indicates that the operating life of P22 pipelines and their welds are dominated by fatigue damage mechanisms. Specifically, fatigue is of no concern in these materials when operating under realistic conditions manifesting in the main steam piping of coal-fueled power plants. However, if a low-temperature overload ever occurs during operation, fatigue will manifest as a damage mechanism of interest. Primary impact provided by the completion of this work is in the manifestation of a detailed ABAQUS solid model providing accurate boundary conditions to enable the prediction of operational stresses and strains. The completed plant solid model, in conjunction with the calibrated fatigue and creep life models provide definitive confirmation that creep is the dominant damage mechanism during operational conditions. Jethete life modelling has been completed by the manifestation of a material-specific, and temperature-specific, Kitagowa diagram. The Kitagowa diagram provides maintenance and operation decision making with scientifically-based go/no-go support based upon the crack-like features that have been identified by use of inspection.

01 COAL, LIGNITE, AND PEAT↗

Statistical Behavior of Low-Amplitude Power System Point-on-Wave Measurements

The power grid is undergoing massive changes to ensure resiliency and reliability in a more decentralized world. Distributed energy resources are becoming a prominent source of generation, potentially leading to a lack of centralized generation sources. Due to these new behaviors and system topologies, it is important to install measurement devices that are 1) accurate and 2) self-aware of their measurement quality. In this paper, a residential-scale microgrid is used to generate voltage and current waveforms, captured by Verivolt and National Instruments measurement equipment. A least-squares approach is used to separate the “clean” signals from the noise. Finally, Gaussian mixture modeling is used to approximate noise distributions, and it is shown these higher-order distribution estimates are a better fit to voltage and current noise profiles than single-mode Gaussian estimates.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Comparing Parameter Estimation Techniques for an Electrical Power Transformer Oil Temperature Prediction Model

This paper examines various sources of error in MIT's improved top oil temperature rise over ambient temperature model and estimation process. The sources of error are the current parameter estimation technique, quantization noise, and post-processing of the transformer data. Results from this paper will show that an output error parameter estimation technique should be selected to replace the current least squares estimation technique. The output error technique obtained accurate predictions of transformer behavior, revealed the best error covariance, obtained consistent parameter estimates, and provided for valid and sensible parameters. This paper will also show that the output error technique should be used to minimize errors attributed to post-processing (decimation) of the transformer data. Models used in this paper are validated using data from a large transformer in service.

Morris, A. Terry↗

Effects of random forest modeling decisions on biogeochemical time series predictions

Abstract Random forests (RF) are an increasingly popular machine learning approach used to model biogeochemical processes in the Earth system. While RF models are robust to many assumptions that complicate deterministic models, there are several important parameterization decisions for appropriate use and optimal model fit. We explored the role that parameter decisions, including training/testing data splitting strategies, variable selection, and hyperparameters play on RF goodness‐of‐fit by constructing models using 1296 unique parameter combinations to predict concentrations of nitrate, a key nutrient for biogeochemical cycling in aquatic ecosystems. Models were built on long‐term, publicly available water quality and meteorology time series collected by the National Estuarine Research Reserve monitoring network for two contrasting ecosystems representing freshwater and brackish estuaries. We found that accounting for temporal dependence when splitting data into training and testing subsets was key for avoiding over‐estimation of model predictive power. In addition, variable selection, the ratio of training to testing data, and to a lesser degree, variables per split and number of trees, were significant parameters for optimizing RF goodness‐of‐fit. We also explored how model parameter decisions influenced interpretation of the relative importance of predictors to the model, and model predictor‐dependent variable relationships, with results suggesting that both data structure and model parameterization influence these factors. Because much of the current RF literature is written for the computational and statistical science communities, the primary goal of this study is to provide guidelines for aquatic scientists new to machine learning to apply RF techniques appropriately to aquatic biogeochemical datasets.

54 ENVIRONMENTAL SCIENCES↗

Cable/Antenna Bounds Connecting Field Levels To Personnel Safety And Electronic Upset Thresholds

We use bounding models to estimate the power delivered to interior ordnance as well as the pin level voltages along a cable at interior electronic components. The procedures underlying these estimates are described in some detail. Conservation of steady-state power in a linear passive system underpins the power estimate, whereas, losses and quality factor limits underpin the limits on voltage transformations. The final levels are compared to no-fire threshold power and to minimum upset voltage levels in an example using a canonical slot aperture and cavity to estimate interior fields.

42 ENGINEERING↗

A Multi-Fidelity Gaussian Process Regression Method for Probabilistic Wind Farm Power Curve Estimation

Accurate estimation of the power curve for wind turbines or wind farms is crucial to ensure their efficient operation and management. However, conventional methods for power curve estimation rely either on expensive and infrequent measurements or on low-quality numerical simulations. Moreover, the majority of previous studies on power curve estimation for wind turbines or wind farms focused on deterministic estimation, which provides a point estimate of the relationship between wind speed and power generation. Nevertheless, the deterministic approach fails to consider the inherent uncertainty associated with wind energy production resulting from varying turbine characteristics. This can lead to inaccurate power generation estimation and suboptimal decisions regarding energy management. In this paper, a kernel density estimation (KDE) based Multi-Fidelity Gaussian Process Regression (MFGPR) model is proposed to fuse theoretical power curve data and the ground true measurements to create a mapping of wind speed and wind power. By conducting a case study on an actual wind farm in China, the efficacy of the proposed MFGPR model was demonstrated in characterizing the variability of wind power. The probabilistic MFGPR model was also able to generate confidence intervals that encompassed the measured power, thereby improving the accuracy and confidence in wind power estimation or wind resource assessment. Overall, the proposed MFGPR model offers a reliable approach to integrate high-fidelity ground measurements and theoretical power curve data, resulting in precise wind resource assessment and power estimation.

Gaussian process regression↗

A General Method for Estimating Zonal Transmission Interface Limits from Nodal Network Data: Preprint

Capacity expansion models for the electric power system often employ zonal (rather than nodal) resolution, necessitating estimates of aggregate power transfer limits across the interfaces between model zones. Interface limits between planning areas are sometimes published, but they are not generalizable to arbitrary zone shapes. There is thus a need for a reproducible method for estimating interface transfer limits (ITLs) between user-defined zones directly from nodal transmission system data. Here, we present a simple method for estimating ITLs using a DC power flow approximation via the power transfer distribution factor (PTDF) matrix. Linear optimization is performed to identify the distribution of power flows that maximizes the total flow on interface-crossing lines, subject to individual line ratings, limits on bus injection/withdrawal, and the relationships among flows, injections, and withdrawals imposed by the PTDF matrix. We demonstrate the application of the method on a 134-zone ~65000-bus system, and we explore the influence of flow direction, contingency level, and zone size on the estimated ITLs. There is significant heterogeneity in the ratio of the ITL to the sum of interface-crossing line ratings, which highlights the importance of accounting for the physical constraints on power flows imposed by Kirchhoff's laws when estimating zonal ITLs.

17 WIND ENERGY↗

Image-based solar estimates

An example device is configured to determine, based on a sky image of a portion of sky over a power distribution network and using a convolutional neural network (CNN)-based image regression model, an estimated global horizontal irradiance (GHI) value and manage or control the power distribution network using the estimated GHI value. The device may also be configured to determine, based on GHI values and aggregate load values for at least a portion of the power distribution network, using a Bayesian Structural Time Series model, an estimated photovoltaic power output value for the at least a portion of the power distribution network. The device may manage or control the power distribution network using the estimated photovoltaic power output value.

Bernstein, Andrey↗

Integrated hydrological, power system and economic modelling of climate impacts on electricity demand and cost

Impacts of climate-related water stress and temperature changes can cascade through energy systems, although models have yet to capture this compounding of effects. Here, we employ a coupled water–power–economy model to capture these important interactions in a study of the exceedance of water temperature thresholds for power generation in the western United States. We find that not all reductions in reserve electricity-generation capacity result in impacts, and that when they occur, intermittent interruptions in electricity supply at critical times of the day, week and year account for much of the economic impacts. Finally, we find that impacts may be in different locations from the original water stress. Herein, we estimate that the consumption loss can be up to 0.3% annually and the drivers identified in coupled modelling can increase the average cost of electricity by up to 3%. Integrated models will be needed to capture the cascading effects of climate change through climatic, water, energy and economic systems. Webster et al. now develop a coupled hydrologic–power-production–economic model to estimate water-stress impacts on electricity cost.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The fundamental structure function of oscillator noise models

Continuous-time models of oscillator phase noise x(t) usually have stationary nth differences, for some n. The covariance structure of such a model can be characterized in the time domain by the structure function: D sub n (t;gamma sub 1, gamma sub 2) = E delta (n) sub gamma sub 1 x(s+t) delta(n) sub gamma sub 2 x (s). Although formulas for the special case D sub 2 (0;gamma,gamma) (the Allan variance times 2 gamma(2)) exist for power-law spectral models, certain estimation problems require a more complete knowledge of (0). Exhibited is a much simpler function of one time variable, D(t), from which (0) can easily be obtained from the spectral density by uncomplicated integrations. Believing that D(t) is the simplest function of time that holds the same information as (0), D(t) is called the fundamental structure function. D(t) is computed for several power-law spectral models. Two examples are D(t) = K/t/(3) for random walk FM, D(t) = Kt(2) 1n/t/ for flicker FM. Then, to demonstrate its use, a BASIC program is given that computes means and variances of two Allan variance estimators, one of which incorporates a method of frequency drift estimation and removal.

Greenhall, C. A.↗

Observability Analysis of a Power System Stochastic Dynamic Model Using a Derivative-Free Approach

Serving as a prerequisite to power system dynamic state estimation, the observability analysis of a power system dynamic model has recently attracted the attention of many power engineers. However, because this model is typically nonlinear and large-scale, the analysis of its observability is a challenge to the traditional derivative-based methods. Indeed, the linear-approximation-based approach may provide unreliable results while the nonlinear-technique-based approach inevitably faces extremely complicated derivations. Furthermore, because power systems are intrinsically stochastic, the traditional deterministic approaches may lead to inaccurate observability analyses. In this work, facing these challenges, we propose a novel polynomial-chaos-based derivative-free observability analysis approach that not only is free of any linear approximations, but also accounts for the stochasticity of the dynamic model while bringing a low implementation complexity. Furthermore, this approach enables us to quantify the degree of observability of a stochastic model, what conventional deterministic methods cannot do. The excellent performance of the proposed method has been demonstrated by performing extensive simulations using a synchronous generator model with IEEE-DC1A exciter and the TGOV1 turbine governor.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Model-Reference Adaptive Direct-Power Control Scheme for Grid-Interactive Inverters

This paper develops an adaptive direct power control scheme for grid-interactive inverters while the control parameters are adaptively adjusted as the grid and filter parameters vary under different conditions. To demonstrate the efficacy and robustness of the adaptive operation, the performance of the adaptive controller is compared with a typical direct power controller by estimating the filter and grid impedances using a model reference parameter estimation technique with small signal injection. The simulation results verify that the developed methodology can track the reference power setpoints under output circuit parameter uncertainties while the typical design leads to instability. To improve the performance of the adaptive technique and eliminate the need for filter parameter estimation, a Lyapunov stability criterion-based model-reference adaptive direct power controller is designed to track the filter impedance. The developed method was tested using MATLAB/Simulink software to demonstrate the effectiveness of the proposed method. The results verify that adaptively tuning the control parameter can still maintain stable operation if the control gains are poorly selected while applying the classical method leads to abnormal operation or instability.

Gursoy, Mehmetcan↗