Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power allocation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A Unified Design Theory for Multi-Port Polyphase Transformers Enabling Scalable Power-Multiplexed EV Fleet Charging Systems

This paper presents a unified analytical design theory for multi-port polyphase transformers, targeting scalable and isolated high-power Electric Vehicle (EV) fleet charging systems with power multiplexing capability. As fleet electrification accelerates, conventional one-to-one charger architectures face significant challenges in infrastructure cost, peak power demand, and low utilization of installed power electronics. Power-multiplexed charging architectures, which dynamically distribute power from a shared pool of converter modules across multiple vehicles, have emerged as a promising solution. However, such architectures require scalable, isolated multi-port power interfaces capable of routing energy among multiple inputs and outputs, whose design remains complex and dependent on iterative modeling. To address this gap, the proposed theory provides closed-form expressions for self-inductance, leakage inductance, and mutual coupling terms for arbitrary multi-phase, multi-port transformer structures. The formulation enables direct synthesis of isolated multi-input and multi-output resonant converter systems without reliance on geometry-specific finite-element analysis or extensive parameter extraction. This capability is particularly critical for power-multiplexed systems, where modular converter structures must interface with multiple vehicles while maintaining galvanic isolation and flexible power allocation. The effectiveness of the proposed framework is demonstrated through the design of a 360 kW multi-phase system operating over a 700–900 VDC input and 400–1250 VDC output range. PLECS simulation results confirm accurate prediction of system behavior and validate the applicability of the approach to multi-port, power-multiplexed charging scenarios. The proposed method significantly reduces design complexity while enabling scalable, cost-effective, and fully utilized EV fleet charging infrastructure.

Asa, Erdem [ORNL] (ORCID:0000000190884812)↗

A systematic solution to quantify economic values of vehicle grid integration

We report Vehicle-Grid-Integration (VGI) supplies one of the potential benefit extensions for electric vehicles (EVs) to make use of their parking time, which enables the EVs to provide grid services while still meeting consumer driving needs. However, the costs, benefits and risks of VGI still remain unclear, which limits the development of the VGI to promote the interaction between the EV and grid. In this study, we propose an integrated framework to quantify and utilize the aggregate flexibility of the EVs to supply the grid services in electricity markets. The integrated solution includes five sub-modules that cover end-to-end functionalities from individual EV energy consumption estimation to final monetary values calculation of providing grid services. Both wholesale market and local level charging management are formulated in the optimization module. A predictive control algorithm is proposed to allocate power to individual vehicles in real time, considering uncertainties from dispatch signal and travel behavior. Simulation results from 10,000 EVs indicate that the proposed optimization methods can significantly reduce the system cost in both wholesale market and retail market. Local tariff optimization reduces the electricity cost by 24.4% compared to uncontrolled charging. Wholesale market optimization results show that $\$$691 and $\$$255 revenues can be captured by each EV in ERCOT and CAISO markets per year, although with a conservative assumption on battery throughput cost at 0.16$\$$/kWh.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Model-Free Control of Grid-Interactive Efficient Buildings Under Communication Time Delays

Grid-interactive efficient buildings (GEBs) have recently been used to enhance the reliability and stability of the electric grid through demand response (DR) programs. However, most existing DR control strategies require accurate modeling of the various building thermostatically controlled loads (TCLs) and are computationally expensive. To address these challenges, a model-free control (MFC)-based strategy has recently been introduced for coordinating and controlling GEBs. MFC is a data-enabled control strategy that is computationally efficient and does not require the analytical models of the various building equipment. In this paper, we numerically investigate the impact of communication time delays on the performance of MFC in maintaining the TCLs' temperatures within the desired comfort levels while meeting the assigned power allocation constraint.

Telsang, Bhagyashri [University of Tennessee, Knox↗

Flexible allocation of energy storage in power grids

Methods and apparatus provide flexible allocation and regulation of scheduled energy transfers between energy storage devices (“batteries”) and a power grid. Piecewise mappings having at least one sloping segment enable gradual variations in scheduled energy transfers as cleared values of a medium of energy exchange deviate from predicted values of the medium of energy exchange. Thereby deviations from a battery's predicted energy transfer schedule can be reduced, and overall smoother operation of a power grid can be achieved. Two sloping linear segments can be separated by a dead band, a portion of the mapping in which the scheduled energy transfer amount is invariant. A dead zone can increase the likelihood of a battery meeting its predicted schedule.

Bhattarai, Bishnu P.↗

A Novel Modular, Reconfigurable Battery Energy Storage System: Design, Control, and Experimentation

This paper presents a novel modular, reconfigurable battery energy storage system. The proposed design is characterized by a tight integration of reconfigurable power switches and DC/DC converters. This characteristic enables isolation of faulty cells from the system and allows fine power control for individual cells toward optimal system-level performance. An optimal power management approach is developed to extensively exploit the merits of the proposed design. Based on receding-horizon convex optimization, this approach aims to minimize the total power losses in charging/discharging while allocating the power in line with each cell’s condition to achieve state of-charge (SoC) and temperature balancing. By appropriate design, the approach manages to regulate the power of a cell across its full SoC range and guarantee the feasibility of the optimization problem. Here, we perform extensive simulations and further develop a lab-scale prototype to validate the proposed system design and power management approach.

25 ENERGY STORAGE↗

Adaptive Reinforcement Learning Control for Power Distribution in Multi-Output Resonant Converters

This paper presents an adaptive reinforcement learning (ARL)-based control framework for efficient power distribution in a multi-output resonant converter for UAV applications. The proposed system is based on a high-frequency isolated resonant architecture, where a single energy source supplies multiple propulsion loads through independently controlled output rectifiers, addressing the need for coordinated multi-motor power management. The ARL framework dynamically allocates output power by learning optimal phase-shift control actions under varying load demands and operating conditions. The agent autonomously determines control parameters that maximize conversion efficiency while ensuring accurate power sharing among multiple outputs. In addition, the proposed approach enables adaptive operation without requiring detailed system modeling or manual tuning. Experimental results demonstrate stable and efficient performance over a wide range of operating conditions, confirming the effectiveness and robustness of the learning-based control strategy for multi-output resonant converter system.

Asa, Erdem [ORNL] (ORCID:0000000190884812)↗

Hybrid prioritized resource allocation in thermally-or power-constrained computing devices

Various embodiments comprise prioritizing frequency allocations in thermally- or power-constrained computing devices. Computer elements may be assigned ‘weights’ based on their priorities. The computer elements with higher weights may receive higher frequency allocations to assure they receive priority in processing more quickly. The computer elements with lower weights may receive lower frequency allocations and suffer a slowdown in their processing. Elements with the same weight may be grouped together for the purpose of frequency allocation.

Al-Rawi, Asma↗

Dynamic Modeling of Power Conversion Stages for an Exascale Supercomputer

In this paper a power conversion and energy consumption model for an exascale supercomputer is investigated. Power consumption, energy loss and efficiency are derived for the 27.2 MW liquid-cooled, centralized, High Performance Computing (HPC) power system, which is supplied directly from the 480 V three-phase mains. Two energy conversion stages are analyzed, measured and modeled. The model is developed in order to be adapted and implemented in a digital twin platform utilizing a Resource Allocator and Power Simulator (RAPS) module. RAPS enables estimation of potential energy savings in the direct AC power supply architecture via both conventional rectifier load sharing (commonly used in HPC systems), as well as smart rectifier load sharing. Moreover, besides the direct AC supply architecture analysis, the full direct DC supply architecture with with 1 kV DC bus were also studied. Comparison of 10 hour time frame operation of the system, with direct 480 V AC voltage supply with conventional and smart load sharing and medium dc voltage supply were done. For the direct AC supply architecture, with conventional and smart load sharing the predicted power loss was approximately 840 kW and 820 kW, respectively and the predicted total system efficiency was 92.87% and 93.05%, respectively. For the direct DC supply architecture with the 1000 V DC supply bus power loss was approximately 340 kW and the predicted total system efficiency was 97.02%.

Wojda, Rafal↗

Power Sharing-Based Framework for Allocating Automatic Generation Control in Distributed Energy Resources: Preprint

The recent proliferation of distributed energy resources (DERs) in the power network along with the retirement of conventional generators has made it challenging to regulate system frequency. In this paper, we present a centralized control framework to leverage the potential of DERs in the distribution network in provisioning secondary frequency control services to the grid. The proposed framework is based on network volt-watt sensitivity analysis and takes into account DER operational and network-imposed constraints to allocate the automatic generation control (AGC) request among the aggregated units. The proposed framework was implemented on the IEEE 8500-node test feeder and results were validated against a standard linear programming-based scheme. Numerical results indicate that the proposed framework can successfully utilize the available power production headroom of the network to meet the AGC request while maintaining nodal voltages within acceptable limits.

distributed energy resources↗

Can Food–Energy–Water Nexus Research Keep Pace with Agricultural Innovation?

The interconnection among food–energy–water (FEW) systems in meeting societal demands is broadly acknowledged. Similarly, competitive or synergistic allocations of water and energy resources for agricultural production, manufacturing, and human consumption are understood, and their economic impacts can be predicted. Far less appreciated and understood are the outcomes of the FEW nexus in response to operation changes in agricultural practices and the associated technological innovations for future generations. Also, the inter-scale and feedback effects of emerging technology-driven resource reallocation and decision-making on FEW systems are largely unknown. For example, how do the agroeconomic feedbacks of intelligent technologies influence the FEW nexus of agricultural production under environmental and demographic changes? How does the necessary water allocation for powering non-powered dams and pumped-storage hydropower generation influence agricultural production and municipal water supply maintenance? How do solar and wind energy farms influence land use for agriculture and the rural economy? In turn, how can the generated solar and wind energy help reduce the cost of groundwater extraction or water desalination?

42 ENGINEERING↗

A Digital Twin Framework for Liquid-cooled Supercomputers as Demonstrated at Exascale

We present ExaDigiT, an open-source framework for developing comprehensive digital twins of liquid-cooled supercomputers. It integrates three main modules: (1) a resource allocator and power simulator, (2) a transient thermo-fluidic cooling model, and (3) an augmented reality model of the supercomputer and central energy plant. The framework enables the study of "what-if" scenarios, system optimizations, and virtual prototyping of future systems. Using Frontier as a case study, we demonstrate the framework's capabilities by replaying six months of system telemetry for systematic verification and validation. Such a comprehensive analysis of a liquid-cooled exascale supercomputer is the first of its kind. ExaDigiT elucidates complex transient cooling system dynamics, runs synthetic or real workloads, and predicts energy losses due to rectification and voltage conversion. Throughout our paper, we present lessons learned to benefit HPC practitioners developing similar digital twins. We envision the digital twin will be a key enabler for sustainable, energy-efficient supercomputing.

Brewer, Wes↗

ExaDigiT/RAPS

ExaDigiT is a framework for developing comprehensive digital twins of liquid-cooled supercomputers, which has three main modules: (1) a python-based Resource Allocator and Power Simulator (RAPS), (2) a Modelica-based Thermo-Fluidic cooling model, and (3) a C++-based augmented reality model built on Unreal Engine 5. RAPS either simulates workloads or replays historical workloads from system telemetry, and is able to predict dynamic energy consumption, as well as interact with the cooling model to predict cooling system behavior. Such a tool can be used together with reinforcement learning algorithms to provide an end-to-end optimization tool for data centers.

Brewer, Wesley [Oak Ridge National Laboratory (ORN↗

datacenterCoolingModel

ExaDigiT is a framework for developing comprehensive digital twins of liquid-cooled supercomputers, which has three main modules: (1) a python-based Resource Allocator and Power Simulator (RAPS), (2) a Modelica-based Thermo-Fluidic cooling model, and (3) a C++-based augmented reality model built on Unreal Engine 5. The Modelica-based cooling model is primarily built-on the open-source Transient Simulation Framework of Reconfigurable Models (TRANSFORM) library and the open-source autocsm library. The library follows the templating architecture developed in the TRANSFORM and the autocsm libraries. This tool can be easily extended to model other Frontier-like liquid cooled supercomputers.

Kumar, Vineet [Oak Ridge National Laboratory (ORNL↗

Model of metabolism and gene expression predicts proteome allocation in Pseudomonas putida

Abstract The genome-scale model of metabolism and gene expression (ME-model) forPseudomonas putidaKT2440,iPpu1676-ME, provides a comprehensive representation of biosynthetic costs and proteome allocation. Compared to a metabolic-only model,iPpu1676-ME significantly expands on gene expression, macromolecular assembly, and cofactor utilization, enabling accurate growth predictions without additional constraints. Multi-omics analysis using RNA sequencing and ribosomal profiling data revealed translational prioritization inP. putida, with core pathways, such as nicotinamide biosynthesis and queuosine metabolism, exhibiting higher translational efficiency, while secondary pathways displayed lower priority. Notably, the ME-model significantly outperformed the M-model in alignment with multi-omics data, thereby validating its predictive capacity. Thus,iPpu1676-ME offers valuable insights intoP. putida’s proteome allocation and presents a powerful tool for understanding resource allocation in this industrially relevant microorganism.

Mathematical & Computational Biology↗

Addressing Function Allocation for the Digital Transformation of Existing Nuclear Power Plants

The existing nuclear power plants in the United States (U.S.) have a vital role in providing carbon-free electricity. For the existing nuclear power plant fleet to remain economically viable, a significant digital transformation that fundamentally changes the way in which these plants are operated, maintained, and supported ought to be seriously considered. Safe and reliable automation is needed. This work describes important considerations and challenges that come with function allocation for the adoption of new automation at existing nuclear power plants. Specifically, this work reviews the state-of-the-art in function allocation guidance and highlights how it can be used within the U.S. nuclear industry. An objective of this work is to present the current challenges and proposed approaches to the human factors community to support future research and development that ultimately supports the effective use of function allocation in the digital transformation of existing nuclear power plants.

99 GENERAL AND MISCELLANEOUS↗

Techno-Economic Viability of Flexible Dispatch of Unconventional Geothermal Systems

Flexible geothermal operations could boost project returns through the allocation of improved power purchase agreements and/or exploitation of power price arbitrage opportunities. In this study, we investigated the techno-economic feasibility of variable flow rate control and time-of-day pricing in closed-loop geothermal systems. We considered U-shaped multilateral system configurations and modeled a variety of technical system parameters. These designs were simulated using a slender-body theory (SBT) model for transient heat transfer and fluid flow. This subsurface model was integrated into the flexible geothermal economic model (FGEM) tool to evaluate the overall flexible geothermal system techno-economics. Future hourly ambient temperature conditions were based on the Sup3rCC dataset. Published datasets were used for future hourly wholesale electricity prices. We analyzed four operating strategies: 1) baseload operation, 2) seasonal dispatch (high flow rate during summer and nominal flow rate during the rest of the year), 3) net generation maximization by varying flow rate to maximize net power output, and 4) revenue maximization by varying flow rate to maximize revenue. We ran all four scenarios for a multiloop configuration with 12 lateral passes, 7-km vertical depth and 87-km total drilling length. Furthermore, we assumed a 60 degrees C/km geothermal gradient and ambient temperature and wholesale electricity prices for New Mexico as a typical state location. The nominal flow rate was set to 80 kg/s. When considering drilling costs of $1,000/m and a discount rate of 7%, the generation maximization scenario resulted in the lowest levelized cost of electricity (LCOE) of ~$150/MWh. When considering project return on investment (ROI), defined as lifetime net income divided by upfront capital costs, all flexible operation scenarios performed better than the base case scenario. The highest ROI of 80% was obtained with the revenue maximization scenario. With drilling costs of $200/m and a discount rate of 5%, the generation maximization scenario resulted in LCOE of $49/MWh.

flexible geothermal↗

Hybridization Assessment of Trybrid Pumped Storage Hydropower System—Part 1: A Case Study of Corral Summit

This report is a part of the deliverables for technical assistance provided to Cat Creek Energy for the Coral Summit Trybrid (Triple Hybrid-Pumped Storage Hydropower, Battery Energy Storage System, and photovoltaic solar energy) energy project. This report explores the operational benefits and challenges of hybridizing an open loop PSH (200MW) located at Mackay, Custer County, Idaho with solar PV (Ground mount 300MW and floating 40MW) and battery (720MWhr). This document reports two activities performed as a part of the hybridization assessment task 1) optimal resource allocation and energy management strategy, and 2) power quality and reliability assessment. From optimal resource allocation and energy management strategy (activity 1), the following key findings can be observed: • Conventional PSH (CPSH) with two reversible pump turbines and separate penstocks can provide required flexibility equivalent to that from two ternary PSH with separate penstock. With single unit CPSH, upper reservoir head cannot be maintained accurately, the variation of water level is rapid and pump mode flexibility is not available. These disadvantages can be overcome by single unit TPSH. However, using two CPSH units with separate penstocks also overcome these disadvantages with the formation of the hydraulic short circuit between two conventional units. • Flooding of the lower reservoir is a severe concern when considering continuous operation for black start. This limits the duration of continuous operation from PSH alone to around 50 hours. Due to the complementary PV and battery action, the duration of continuous operation and smooth power output can be extended. • An optimization problem is framed that maximizes the power output on an hourly basis while minimizing constraint violations and respecting seasonal variations of solar PV and load profiles . Two value streams, arbitrage and baseload generation are served by this profile. It was uncovered that for smooth power output during regular operation, PV curtailment will be required, or the battery capacity needs to be increased above 90MW to accommodate additional PV. From power quality and reliability assessment (activity 2) the following takeaway points can be observed: • The Trybrid, when integrated at the Lost River bus, and limited to 250MW in generation mode and -150MW in the pump mode, causes no violation of voltage or flow.

13 - HYDRO ENERGY↗