Lasing in 15 atm CO 2 cell optically pumped by a Fe:ZnSe laser

10 µm lasing is studied in a compact CO 2 -He cell pressurized up to 15 atm when optically pumped by a ∼50 mJ Fe:ZnSe laser tunable around 4.3 µm. The optimal pump wavelength and partial pressure of CO 2 for generating 10 µm pulses are found to be ∼4.4 µm and 0.75 atm, respectively. Without cavity optimization, the optical-to-optical conversion efficiency reached ∼10% at a total pressure of 7 atm. The gain lifetime is measured to be ∼1 µs at pressures above 10 atm, indicating the feasibility of using high-pressure optically pumped CO 2 for the efficient amplification of picosecond 10 µm pulses.

Tovey, Dana↗

A laser head for simultaneous optical pumping of several dye lasers

Device accomplishes simultaneous optical pumping using single flashlamp and electrical driver. Dye lasers require relatively low energy to operate (low-threshold pumping requirement) and provide simple method for producing simultaneous independent laser output at number of different wavelengths.

Mumola, P. B.↗

Collisional narrowing by polyatomic buffer gases in an optically pumped CH3F laser

The gain linewidth of an optically pumped CH3F molecular laser is observed with the addition of various polyatomic buffer gases. This is interpreted as collisional (Dicke) narrowing. The measurement is the first observation of collisional narrowing by polyatomic buffer gases. It is also the first observation of the effect in a laser oscillator. The effect was observed using a heterodyne mixing technique at the laser emission frequency of 604 GHz. Collision cross sections for SF6-CH3F and CS2-CH3F are obtained.

Lawandy, N. M.↗

Optically pumped polarized 3 He ++ ion source development for RHIC/EIC

The proposed polarized 3 He ++ acceleration in RHIC and the future Electron-Ion Collider will require about 2×10 11 ions in the source pulse. A new technique had been proposed for production of high intensity polarized 3 He ++ ion beams. It is based on ionization and accumulation of the 3 He gas (polarized by metastability-exchange optical pumping and in the 5T high magnetic field) in the existing Electron Beam Ion Source (EBIS). A novel 3 He cryogenic purification and storage technique was developed to provide the required gas purity. An original gas refill and polarized 3 He gas injection to the EBIS long drift tubes, (which serves as the storage cell) were developed to ensure polarization preservation. An infrared laser system for optical pumping and polarization measurements in the high 3–5 T field has been developed. The 3 He polarization 80–85% (and sufficiently long ~30 min relaxation time) was obtained in the “open” cell configuration with refilling valve tube inlet and isolation valve closed. The development of the spin-rotator and 3 He 4 He absolute nuclear polarimeter at 6 MeV 3 He ++ beam energy is also presented here in this work.

43 PARTICLE ACCELERATORS↗

Optically pumped submillimeter-waves and applications

Rapid development of optically pumped lasers has shown the potential to be used as a source for a high resolution spectrometer. In this connection, a compact, stable FIR laser was designed, fabricated, and assembled, integrating both the pump laser and the FIR cavity in the same mechanical structure for its improved (both thermal and mechanical) stability and mobility. Performance of the mixer structure which was designed and constructed for the evaluation of the Schottky diodes was found to be satisfactory. The feasibility of generating tunable sideband for molecular spectroscopy studies was demonstrated.

Dutta, J. M.↗

A proposed optical pumping system requiring no electric power

A method for optically pumping a fluid without electrical power is described. The method is based on utilizing the radiation from a metal oxidant combustion reaction that is contained within a transparent tube that is immersed in the medium to be pumped. The reaction initiation and maintenance occurs by gas dynamically induced resonance within the transparent cavity. All that is required is a supply of high pressure oxidant and metallic powder. Materials that were successfully evaluated to date include aluminum, steel, magnesium, and titanium.

Phillips, B. R.↗

Assignment of the /Li-7/2 optically pumped laser transitions pumped by Ar/+/ and Kr/+/ laser lines

Welling and Wellegehausen (1977) have reported a list of Na2 and Li2 lines (belonging to B-X and A-X systems) which lase when vapors of these dimers are pumped with an Ar(+) or Kr(+) laser. A description is presented of a fluorescence study of the A-X system of the (Li-7)2 molecule excited by a Kr(+) laser (6471 A). The optically pumped laser lines are identified as P and R doublets in two different fluorescence series. The conditions which favor lasing action of these lines are pointed out. All but one of the known optically pumped laser lines of (Li-7)2 along with their assignments are presented in a table. For each pumping line, several additional wavelengths are listed which satisfy the condition for laser oscillations and which might well lase well under slightly improved conditions.

Verma, K. K.↗

Collisional narrowing in the optically pumped CH3OH and CH3F lasers

The gain linewidth of the optically pumped CH3F laser is observed to narrow and rebroaden with the addition of He. In addition, the same effect is observed in the CH3OH laser with the addition of the polyatomic buffer gases SF6 and CS2. These results offer conclusive evidence of the Dicke narrowing phenomena in these inverted pure rotational transitions. The effect is observed using a high harmonic mixing technique in a Schottky barrier diode.

Lawandy, N. M.↗

Optically pumped, radio-frequency atomic magnetometry with feedback stabilization

An optically pumped, atomic magnetometer incorporates a feedback system for stabilizing the magnetic bias field and suppressing unwanted background fields. The magnetic bias field is applied to a vapor cell containing host atoms of two different species, each of which resonates at a different Larmor frequency when both are subjected to the same magnetic bias field. One species provides the feedback for stabilizing the bias field, thereby creating a stabilizing magnetometer portion that nulls out the unwanted background fields. The other species provides magnetic field detection or signal reception on a radio communication frequency of interest, thereby creating a signal magnetometer portion that permits detection of the signal at the radio communication frequency.

Schwindt, Peter D. D.↗

Metastability exchange optical pumping of 3 He at low pressure and high magnetic field

We report systematic studies on metastability exchange optical pumping of 3 He nuclei have been performed at Jefferson Lab using a 1-torr sealed cell at magnetic fields from 2 to 4 T. The effects of the discharge intensity, pump laser power and pumping transition schemes on achievable nuclear polarization and pumping rate have been investigated. A maximum steady-state nuclear polarization of about 75% has been obtained. This work provides a baseline for the development of the novel polarized 3 He target for CLAS12 at Jefferson Lab.

47 OTHER INSTRUMENTATION↗

Optically pumped semiconductor laser based on a type-II CdS/ZnSe heterostructure

An optically pumped semiconductor laser based on a type-II CdS/ZnSe nanoheterostructure containing 10 quantum wells (QWs) was studied. The structure was grown by metal-organic vapour phase epitaxy on a GaAs substrate. The lifetime of electron-hole pairs at a low pump level was measured by luminescence decay to be ∼0 ns. The peak power of the microcavity semiconductor laser at room temperature and longitudinal pumping by a repetitively pulsed N{sub 2} laser was 7.2 W at a wavelength of 514 nm. The relatively low laser slope efficiency (0.35 %) is explained by amplified spontaneous emission propagating along the structure. The peak power and efficiency of the laser in the case of transverse pumping increase to 70 W and 3.5 %, respectively. (lasers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantum mechanical features of optically pumped CW FIR lasers

Quantum mechanical predictions for the gain of an optically pumped CW FIR laser are presented for cases in which one or both of the pump and FIR transitions are pressure or Doppler broadened. The results are compared to those based on the rate equation model. Some of the quantum mechanical predictions are verified in CH3OH.

Seligson, D.↗

Four-channel optically pumped magnetometer for a magnetoencephalography sensor array

We present a novel four-channel optically pumped magnetometer (OPM) for magnetoencephalography that utilizes a two-color pump/probe scheme on a single optical axis. We characterize its performance across 18 built sensor modules. The new sensor implements several improvements over our previously developed sensor including lower vapor-cell operating temperature, improved probe-light detection optics, and reduced optical power requirements. The sensor also has new electromagnetic field coils on the sensor head which are designed using stream-function-based current optimization. We detail the coil design methodology and present experimental characterization of the coil performance. The magnetic sensitivity of the sensor is on average 12.3 fT/rt-Hz across the 18 modules while the average gradiometrically inferred sensitivity is about 6.0 fT/rt-Hz. The sensor 3-dB bandwidth is 100 Hz on average. The on-sensor coil performance is in good agreement with the simulations.

Iivanainen, Joonas (ORCID:0000000160344604)↗

High-Sensitivity rf Detection Using an Optically Pumped Comagnetometer Based on Natural-Abundance Rubidium with Active Ambient-Field Cancellation

To detect a specific radio-frequency (rf) magnetic field, rf optically pumped magnetometers (OPMs) require a static magnetic field to set the Larmor frequency of the atoms equal to the frequency of interest. However, unshielded and variable magnetic field environments (e.g., an rf OPM on a moving platform) pose a problem for rf OPM operation. Here, we demonstrate the use of a natural-abundance rubidium vapor to make a comagnetometer to address this challenge. Our implementation builds upon the simultaneous application of several OPM techniques within the same vapor cell. First, we use a modified implementation of an OPM variometer based on 87 Rb to detect and actively cancel unwanted external fields at frequencies ≲60 Hz using active feedback to a set of field control coils. In this experiment, we exploit this stabilized field environment to implement a high-sensitivity rf magnetometer using 85 Rb. Using this approach, we demonstrate the ability to measure rf fields with a sensitivity of approximately 9 fT Hz -1/2 inside a magnetic shield in the presence of an applied field of approximately 20 μT along three mutually orthogonal directions. This demonstration opens up a path toward completely unshielded operation of a high-sensitivity rf OPM.

47 OTHER INSTRUMENTATION↗

Pressure effects on the frequency of continuous-wave optically pumped far-infrared lasers

The frequency of the 170.6-micron CW CH3OH optically pumped laser emission has been remeasured at different pressures without observing the pressure shift observed by Lawandy and Koepf (1980). The far-infrared frequency was synthesized with two stabilized CO2 lasers. No measurable pressure shift over the operating pressure range of the laser was observed, and the frequency was confirmed to be 1 757 526.3 MHz. However, competing lasing lines were found to produce spurious effects on the frequency. These effects may explain the apparent shifts.

Inguscio, M.↗

Amplification of 10 μm picosecond pulses in a compact optically pumped multiatmosphere CO 2 laser

Picosecond pulses, generated by a commercial mid-IR optical parametric source (∼0.5 ps, 1-5 μJ), have been regeneratively amplified to an energy of ≤2 mJ in a palm-size high-pressure CO 2 amplifier optically pumped by a Q-switched 2.8 μm Cr:Er:YSGG laser. The characteristics of the amplified pulses have been studied as a function of seed wavelength centered around 10.3 or 10.6 μm, and the pressure in the gain medium. The measured amplified pulse length is ∼5 ps. Numerical modeling suggests that pulses as short as ∼0.5 ps with multi-GW peak power can be generated in a mixture of CO 2 isotopes. Robustness of the output of a compact CO 2 regenerative amplifier to the seed and pump fluctuations measured at 3 Hz and a perfect Gaussian beam profile indicates the potential of such laser technology for producing high-power ultrashort long-wave infrared pulses at high repetition rates.