Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “noble liquids”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Installation and Commissioning of the SBC-LAr10 Detector at Fermilab

This report describes the progress towards a scalable detector capable of quasi-background-free detection of sub-keV nuclear recoils under DOE award DE-SC0024254. Work supported by this award follows two distinct thrusts: (1) the first calibration of sensitivity to sub-keV nuclear recoils in a liquid-noble bubble chamber, based on data taken in a prototype liquid xenon bubble chamber run previously at Northwestern University, and (2) the successful assembly and installation of the 10-kg liquid argon bubble chamber SBC-LAr10 in the MINOS underground area at Fermilab. These accomplishments have paved the way for the precision calibration of SBC-LAr10 in the MINOS underground area at Fermilab in the coming year, which will use novel calibration techniques to measure the potential of the liquid noble bubble chamber technology for the detection of GeV-scale dark matter particles and the measurement of coherent elastic nuclear scattering by reactor anti-neutrinos (CEvNS).

47 OTHER INSTRUMENTATION↗

Calibration plan for the SBC 10-kg liquid argon detector with 100 eV target threshold

The Scintillating Bubble Chamber (SBC) Collaboration is designing a new generation of low background, noble liquid bubble chamber experiments with sub-keV nuclear recoil threshold. These experiments combine the electronic recoil blindness of a bubble chamber with the energy resolution of noble liquid scintillation, and maintain electron recoil discrimination at higher degrees of superheat (lower nuclear recoil thresholds) than Freon-based bubble chambers. A 10-kg liquid argon bubble chamber has the potential to set world leading limits on the dark matter nucleon cross-section for 𝒪(GeV/c 2 ) masses, and to perform a high statistics coherent elastic neutrino nuclear scattering measurement with reactor neutrinos. This work presents a detailed calibration plan to measure the detector response of these experiments, combining photoneutron scattering with two new techniques to induce sub-keV nuclear recoils: nuclear Thomson scattering and thermal neutron capture.

Dark Matter detectors (WIMPs, axions, etc.)↗

Readout of Large Capacitance SiPMs by Weak Coupling to Charge Sensitive Amplifier

Large area and large capacitance silicon photomultiplier (SiPM) arrays are employed to collect scintillation light in noble liquid time projection chambers (TPC) such as DarkSide, nEXO, MEGII, protoDUNE and DUNE. Light readout using ASICs designed for operation in noble liquids is a solution for large meter-scale photon detectors. However, conventional readout requires a high voltage decoupling capacitor larger than SiPM capacitance (in the range of tens of nF) to achieve full charge transfer to the preamplifier. Here, we demonstrate a readout concept by weakly coupling (via a capacitor lower by an order of magnitude than SiPM capacitance) to a charge sensitive amplifier, LArASIC in this case, without any loss in the signal to noise ratio (S/N). The single-photoelectron detection, signal-to-noise ratio, timing resolution, and coincidence detection are experimentally characterized.

47 OTHER INSTRUMENTATION↗

Measurements of electron transport in liquid and gas Xenon using a laser-driven photocathode

Measurements of electron drift properties in liquid and gaseous xenon are reported. The electrons are generated by the photoelectric effect in a semitransparent gold photocathode driven in transmission mode with a pulsed ultraviolet laser. The charges drift and diffuse in a small chamber at various electric fields and a fixed drift distance of 2.0 cm. At an electric field of 0.5 kV/cm, the measured drift velocities and corresponding temperature coefficients respectively are 1.97 ± 0.04 mm/µs and (-0.69 ± 0.05)%/K for liquid xenon, and 1.42 ± 0.03 mm/µs and (+0.11 ± 0.01)%/K for gaseous xenon at 1.5 bar. In addition, we measure longitudinal diffusion coefficients of 25.7±4.6 cm2/s and 149±23 cm2/s, for liquid and gas, respectively. The quantum efficiency of the gold photocathode is studied at the photon energy of 4.73 eV in liquid and gaseous xenon, and vacuum. These charge transport properties and the behavior of photocathodes in a xenon environment are important in designing and calibrating future large scale noble liquid detectors.

Njoya, Oumarou↗

Modeling impurity concentrations in liquid argon detectors

Impurities in noble liquid detectors used for neutrino and dark matter experiments can significantly impact the quality of data. We present an experimentally verified model for describing the dynamics of impurity distributions in liquid argon (LAr) detectors. The model considers sources, sinks, and transport of impurities within and between the gas and liquid argon phases. Measurements of oxygen concentrations in a 20-L LAr multi-purpose test stand are compared to calculations made with this model to show that an accurate description of the concentrations under various operational conditions can be obtained. A result of this analysis is a determination of Henry’s coefficient for oxygen in LAr. Additionally, these calculations also show that some processes have small effects on the impurity dynamics and excluding them yields a solution as a sum of two exponential terms. This solution provides a simple way to extract Henry’s coefficient with negligible approximation error. It is applied to the data and the Henry’s coefficient for oxygen in LAr is obtained as 0.84 +0.09 -0.05 , consistent with literature results. Finally, based on the analysis of the data with the model, we further suggest that, for a large liquid argon detector, barriers to flow (“baffles”) installed in the gas phase to restrict flow can help reduce the ultimate impurity concentration in the LAr.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Scintillating Bubble Chambers for Direct Dark Matter Detection, and an Update on SBC-LAr10

The Scintillating Bubble Chamber (SBC) Collaboration aims to use the liquid-noble bubble chamber technology as a low-threshold detector for dark matter particles of 1-10 GeV/c2. The detector combines the remarkable electron recoil (ER) discrimination of the bubble chamber with the event-by-event energy resolution provided by liquid argon (LAr) scintillation, with the crucial added benefit that ER discrimination in liquid-noble bubble chambers extends to much lower thresholds than in past freon-filled bubble chambers, with the potential for quasi-background-free operation at thresholds of 100 eV in nuclear recoil (NR) energy. SBC has developed two functionally identical 10 kg detectors: SBC-LAr10 at Fermilab will calibrate low-threshold performance, while the radio-pure SBC-SNOLAB chamber will execute SBC s first deep-underground dark matter search. SBC-LAr10 at Fermilab was recently installed in the MINOS tunnel 100 meters underground, and the first bubbles are expected this fall. I will present the current status of SBC-LAr10 and describe the suite of gamma and neutron calibrations we will execute. The calibrations will confirm the physics reach of this new technology, motivating not just the SBC-SNOLAB chamber now being assembled but also future searches into the solar neutrino fog at 1 GeV/c2.

Sheng, Zhiheng↗

Scintillating Bubble Chambers for Direct Dark Matter Detection, and an Update on SBC-LAr10

The Scintillating Bubble Chamber (SBC) Collaboration aims to use the liquid-noble bubble chamber technology as a low-threshold detector for dark matter particles of 1-10 GeV/c2. The detector combines the remarkable electron recoil (ER) discrimination of the bubble chamber with the event-by-event energy resolution provided by liquid argon (LAr) scintillation, with the crucial added benefit that ER discrimination in liquid-noble bubble chambers extends to much lower thresholds than in past freon-filled bubble chambers, with the potential for quasi-background-free operation at thresholds of 100 eV in nuclear recoil (NR) energy. SBC has developed two functionally identical 10 kg detectors: SBC-LAr10 at Fermilab will calibrate low-threshold performance, while the radio-pure SBC-SNOLAB chamber will execute SBC s first deep-underground dark matter search. SBC-LAr10 at Fermilab was recently installed in the MINOS tunnel 100 meters underground, and the first bubbles are expected this fall. I will present the current status of SBC-LAr10 and describe the suite of gamma and neutron calibrations we will execute. The calibrations will confirm the physics reach of this new technology, motivating not just the SBC-SNOLAB chamber now being assembled but also future searches into the solar neutrino fog at 1 GeV/c2.

Sheng, Zhiheng↗

Characterization of spurious-electron signals in the double-phase argon TPC of the DarkSide-50 experiment

Spurious-electron signals in dual-phase noble-liquid time projection chambers have been observed in both xenon and argon Time Projection Chambers (TPCs). This paper presents the first comprehensive study of spurious electrons in argon, using data collected by the DarkSide-50 experiment at the INFN Laboratori Nazionali del Gran Sasso (LNGS). Understanding these events is a key factor in improving the sensitivity of low-mass dark matter searches exploiting ionization signals in dual-phase noble liquid TPCs. We find that a significant fraction of spurious-electron events, ranging from 30 to 70% across the experiment's lifetime, are caused by electrons captured from impurities and later released with delays of order 5-50 ms. The rate of spurious-electron events is found to correlate with the operational condition of the purification system and the total event rate in the detector. Finally, we present evidence that multi-electron spurious electron events may originate from photo-ionization of the steel grid used to define the electric fields. These observations indicate the possibility of reduction of the background in future experiments and hint at possible spurious electron production mechanisms.

Agnes, P. [GSSI, Aquila; Gran Sasso]↗

SCGSR Final Report

Dual phase noble liquid time projection chambers (TPCs) have an unprecedented sensitivity towards dark matter searches and neutrinos, owing to their ability to detect single electrons. When a particle deposits energy into one of these detectors, electrons are released and drifted into a gaseous region of high electric field. In the gas, the electrons are accelerated to produce extra light into what is called an S2 pulse. This light is far easier to detect than the current induced from a single electron. The two widely used elements for noble liquid detectors are Xe and Ar. Xe has a larger chance of being hit by neutrinos or dark matter, but ends with a lower (i.e. harder to detect) energy when struck. However, Ar light is hard to reflect and detect due to its short wavelength which is absorbed by most materials. While one may use TPB to re-emit this light at a longer wavelength, spatial variations of TPB thickness can smear the amount of re-emitted light, and thus cause a poor S2 energy resolution and spatial resolution. Furthermore, a single electron pulse in Ar is spread over a much longer time than one in Xe, which makes it harder to identify single electrons in Ar. The goal of Xe doping is to combine the best aspects of Ar with the best aspects of Xe. More specifically, this means a detector with a larger yield of photons and electrons produced per energy deposition, an ability to collect more of the light given by those signals, and a narrower pulse from the electron signal. During this project, we developed and operated a detector that can overcome the thermodynamic challenges of Xe doping – namely, preventing Xe from freezing. In the first experimental run during this award period, we found that we can achieve at least 5% of Xe in LAr, and measure the Xe concentration in the gas. In the second run, we installed our detector and saw the first S2 pulses in a dual phase Xe doped LAr TPC. With the data we took, we quantified the effect of Xe doping on the detectability of wavelength-shifted light produced in a Xe doped Ar mixture, as well as the single electron pulse shape. While the Ar light has successfully been wavelength shifted, we learned that much to our surprise, Xe doping actually makes the S2 pulse wider before it makes it narrower.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Flow and thermal modelling of the argon volume in the DarkSide-20k TPC

The DarkSide-20k dark matter experiment, currently under construction at LNGS, features a dual-phase time projection chamber (TPC) with a ∼ 50 t argon target from an underground well. At this scale, it is crucial to optimise the argon flow pattern for efficient target purification and for fast distribution of internal gaseous calibration sources with lifetimes of the order of hours. To this end, we have performed computational fluid dynamics simulations and heat transfer calculations. The residence time distribution shows that the detector is well-mixed on time-scales of the turnover time (∼ 40 d). Notably, simulations show that despite a two-order-of-magnitude difference between the turnover time and the half-life of 83m Kr of 1.83 h, source atoms have the highest probability to reach the centre of the TPC 13 min after their injection, allowing for a homogeneous distribution before undergoing radioactive decay. We further analyse the thermal aspects of dual-phase operation and define the requirements for the formation of a stable gas pocket on top of the liquid. We find a best-estimate value for the heat transfer rate at the liquid-gas interface of 62 W with an upper limit of 144 W and a minimum gas pocket inlet temperature of 89 K to avoid condensation on the acrylic anode. This study also informs the placement of liquid inlets and outlets in the TPC. The presented techniques are widely applicable to other large-scale, noble-liquid detectors.

47 OTHER INSTRUMENTATION↗

A study of DC electrical breakdown in liquid helium through analysis of the empirical breakdown field distributions

Here we report results from a study on electrical breakdown in liquid helium using near-uniform-field stainless steel electrodes with a stressed area of ~0.7cm 2 . The distribution of the breakdown field is obtained for temperatures between 1.7 K and 4.0 K, pressures between the saturated vapor pressure and 626 Torr, and with electrodes of different surface polishes. A data-based approach for determining the electrode-surface-area scaling of the breakdown field is presented. The dependence of the breakdown probability on the field strength as extracted from the breakdown field distribution data is used to show that breakdown is a surface phenomenon closely correlated with Fowler–Nordheim field emission from asperities on the cathode. We show that the results from this analysis provide an explanation for the supposed electrode gap-size effect and also allow for a determination of the breakdown-field distribution for arbitrary shaped electrodes. Most importantly, the analysis method presented in this work can be extended to other noble liquids to explore the dependencies for electrical breakdown in those media.

74 ATOMIC AND MOLECULAR PHYSICS↗

Using Simulation to Interpret LArS's Results

Scintillation light analysis in liquid argon based neutrino detectors is restrained in capability due to uncertainty in fundamental constants critical to the analysis process. One such property is the Rayleigh scattering length of liquid argon. In the fall of 2023, the TallBo cryostat, located in the Noble Liquid Testing Facility (NLTF) at Fermilab, was used to study the scattering length of liquid argon in the Liquid Argon Scattering (LArS) experiment. Due to systematic errors unknown during measurement analysis, LArS s measurements were quite uncertain. By simulating the LArS experiment, we found that the downturn in detector count rate as a function of liquid argon height at low heights was caused by a misplaced silicon photo multiplier (SiPM). With concentrated effort, we may be able to successfully correct this effect by understanding the relationship between the specified Rayleigh scattering length and the measured attenuation length. With this information and further progression in analysis, we may be able to extract corrected measurements from the LArS data and attain a tangible experimental measurement of the scattering length of liquid argon.

Breaux, Auto D. [Tulane U.]↗

Influence of Surfactants on Noble Metal Liquid-Gas Interface Mass Transfer in Molten Salt Reactors

Noble metals, a group of insoluble fission products (FPs), can accumulate in molten salt reactors (MSRs) and influence system performance and safety through deposition. Upon generation in fission, noble metals are transported by circulating salt and may either deposit on structural surfaces or enter the circulating gas bubble interfaces. While sparging was primarily designed for xenon and krypton removal, the mass transfer of noble metals into bubble interfaces highlights a potential pathway for their transport and partial extraction. The properties of the liquid-gas interface therefore play an important role in noble metal deposition and removal behaviors. Observations from earlier studies suggest that noble metals accumulated at the bubble interface can act as surfactants, making the bubble interface partially immobile. This behavior reduces the mass transfer capacity of circulating bubbles and affects both the overall distribution of noble metals in the loop and their removal efficiency. To investigate the influence of surfactants on noble metal transport, deposition, and extraction behaviors in MSRs, a previously developed and validated species transport model incorporating noble metal interphase mass transfer was used to simulate these behaviors. Two designed cases were studied to predict the distribution of 132Te along the Molten Salt Reactor Experiment (MSRE) loop under different bubble interface conditions. The results show that the mass transfer coefficients at the liquid-gas interface, determined by bubble interface characteristics, significantly influence noble metal distribution within the reactor loop. These findings emphasize the importance of continuously introducing fresh circulating bubbles into the molten salt to improve the removal efficiency of insoluble FPs from the MSR primary loop.

MSR↗

Overview of Collaborative Research Between UNICAMP in Brazil and Fermilab in Cryogenics

The Long-Baseline Neutrino Facility (LBNF) situated at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, serves as the host for the Deep Underground Neutrino Experiment (DUNE), employing cryostats with nearly 70,000 metric tons of high purity liquid argon (LAr). The integrity of LAr quality is pivotal in determining the electron lifetime within DUNE, directly impacting its signal-to-noise ratio. Specifically, Far Detector 1 (FD-1) in cryostat 1 requires an electron lifetime over 3 ms within its 3.5 m drift, corresponding to less than 100 parts-per-trillion (ppt) Oxygen equivalent contamination. Far Detector 2 (FD-2) in cryostat 2 demands over 6 ms electron lifetime within its 6.0 m drift, corresponding to less than 50 ppt Oxygen equivalent contamination. Nitrogen (N2) absorption of LAr scintillation light, known as quenching, necessitates N2 contamination in LAr to remain below 1 ppm to minimize photon loss and enhance energy reconstruction. Studies indicate that at 1 ppm N2, approximately 20% of scintillation light is lost, highlighting the importance of minimizing N2 contamination. Brazil State University of Campinas's (UNICAMP) contribution to LBNF focuses on developing argon purification and regeneration for DUNE FD-1 and FD-2. To that effect, they constructed a test facility to perform studies on LAr purification at a smaller scale, the Purification Liquid Argon Cryostat (PuLArC) with approximately 90 liters of LAr. One of the filtration materials was considered and tested Li-FAU molecular sieve. Value engineering on argon purification media was conducted, leading to the identification of Li-FAU zeolite's ability to effectively capture N2 impurities during LAr circulation. Testing at UNICAMP's PuLArC facility demonstrated that 1 kg of Li-FAU is capable of reducing N2 contamination from 20-50 ppm to 0.1-1.0 ppm within 1-2 hours of circulation. In October 2023, testing at the Iceberg cryostat in Fermilab's Noble Liquid Test Facility (NLTF), with approximately 2,625 liters of LAr, confirmed the efficacy of 3 kg of Li-FAU in reducing N2 contamination from ~ 5 ppm of injected N2 down to less than 1 ppm over 96-hour cycles, showcasing its potential for larger-scale LAr cryostats. Further tests are planned to validate Li-FAU's use as a possible alternative to Molecular Sieve 4A in LBNF-DUNE and related liquid argon experiments. This contribution will describe how the research was performed and present the test setups and results in detail. This advancement not only has the potential to enhance DUNE's precision but also to elevate liquid argon experiments globally, showcasing the power of international scientific collaboration.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

LArCADe | Liquid Argon Charge Amplification Devices

The Liquid Argon Charge Amplification Devices (LArCADe) project is an R$\&$D effort aimed at developing instrumentation capable of lowering detection thresholds for ionization signatures in liquid and gaseous argon detectors and achieving O(100 $\mu$m) position resolution. The core concept is the use of sharp “tip arrays” that generate strong local electric-field enhancement, enabling charge amplification and collection with improved spatial resolution. A key physics motivation for this work is to enhance the experimental sensitivity of Coherent Elastic Neutrino-Nucleus Scattering (CEvNS) measurements to low-energy nuclear recoils by enabling spatially resolved charge reconstruction at reduced ionization thresholds, with the goal of achieving event-by-event energy reconstruction for interactions originating from localized accelerator or astrophysical neutrino sources. This poster will present the current status of the instrumentation R$\&$D, which leverages Fermilab’s Noble Liquid Test Facility and UC Santa Barbara’s Nanofabrication Facility, and will discuss the potential physics impact of this technology.

Antonakis, Alexander [UC, Santa Barbara]↗

Numerical Investigation of Fluid Flow and Space Charge in Liquid Argon Time Projection Chamber (LArTPC) Detectors

Overview This project focused on developing a high-fidelity numerical framework to simulate the multiphysics environment within Liquid Argon Time Projection Chamber (LArTPC) detectors. The primary objective was to characterize the complex interplay between ion transport, background fluid dynamics, and electric field distortions—a critical factor for the calibration and sensitivity of next-generation High Energy Physics experiments, such as DUNE. Technical Achievements The research successfully yielded a hybrid numerical space-charge solver utilizing a Cell-Centered Finite Volume Method (FVM) for ion transport coupled with a Finite Element Method (FEM) for electric potential. Key accomplishments include: • Verification & Validation: The 3-D solver was rigorously verified against 1-D analytical solutions, demonstrating high numerical accuracy in predicting space-charge-induced field deviations. • Field Distortion Analysis: 3D simulations revealed that space charge effects introduce significant non-uniformities in the electric field. Critically, the research identified that background LAr flow velocities, when comparable to ion drift velocities, markedly exacerbate these distortions. • Technology Transfer: The resulting source code and comprehensive user manuals were successfully transferred to collaborators at Fermilab, providing a portable computational tool for the broader scientific community. Challenges and Future Directions While the space-charge solver achieved all performance metrics, the integrated fluid dynamics modeling encountered convergence challenges stemming from the extreme 200-fold disparity in length scales between the detector's 37 mm inlet pipes and the 8-meter global domain. To address this, the project has identified a clear technical pivot toward Hierarchical Geometric Adaptive Mesh Refinement (HG-AMR). By implementing an h-type refinement strategy with hanging nodes, future iterations of this solver will be capable of resolving localized high-gradient inlet flows without the prohibitive computational costs of regular grids. This advancement, combined with data-driven uncertainty quantification based on MicroBooNE-style calibration, will enable the precise modeling of detector responses in large-scale cryogenic environments where direct measurement remains difficult. Impact The computational tools developed under this award provide a foundation for enhancing the energy resolution and spatial reconstruction of noble liquid detectors. By bridging the gap between theoretical fluid dynamics and experimental field calibration, this work supports the DOE’s mission to advance the frontiers of neutrino physics and dark matter detection.

42 ENGINEERING↗

Scintillating Bubble Chambers for Rare Event Searches

The Scintillating Bubble Chamber (SBC) collaboration is developing liquid-noble bubble chambers for the detection of sub-keV nuclear recoils. These detectors benefit from the electron recoil rejection inherent in moderately-superheated bubble chambers with the addition of energy reconstruction provided from the scintillation signal. The ability to measure low-energy nuclear recoils allows the search for GeV-scale dark matter and the measurement of coherent elastic neutrino-nucleus scattering on argon from MeV-scale reactor antineutrinos. The first physics-scale detector, SBC-LAr10, is in the commissioning phase at Fermilab, where extensive engineering and calibration studies will be performed. In parallel, a functionally identical low-background version, SBC-SNOLAB, is being built for a dark matter search underground at SNOLAB. SBC-SNOLAB, with a 10 kg-yr exposure, will have sensitivity to a dark matter–nucleon cross section of 2×10 –42 cm 2 at 1 GeV/c 2 dark matter mass, and future detectors could reach the boundary of the argon neutrino fog with a tonne-yr exposure. In addition, the deployment of an SBC detector at a nuclear reactor could enable neutrino physics investigations including measurements of the weak mixing angle and searches for sterile neutrinos, the neutrino magnetic moment, and the light Z’ gauge boson.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Molecular hydrodynamic theory of the velocity autocorrelation function

The velocity autocorrelation function (VACF) encapsulates extensive information about a fluid’s molecular-structural and hydrodynamic properties. We address the following fundamental question: How well can a purely hydrodynamic description recover the molecular features of a fluid as exhibited by the VACF? To this end, we formulate a bona fide hydrodynamic theory of the tagged-particle VACF for simple fluids. Our approach is distinguished from previous efforts in two key ways: collective hydrodynamic modes and tagged-particle self-motion are modeled by linear hydrodynamic equations; the fluid’s spatial velocity power spectrum is identified as a necessary initial condition for the momentum current correlation. This formulation leads to a natural physical interpretation of the VACF as a superposition of products of quasinormal hydrodynamic modes weighted commensurately with the spatial velocity power spectrum, the latter of which appears to physically bridge continuum hydrodynamical behavior and discrete-particle kinetics. The methodology yields VACF calculations quantitatively on par with existing approaches for liquid noble gases and alkali metals. Furthermore, we obtain a new, hydrodynamic form of the self-intermediate scattering function whose description has been extended to low densities where the Schmidt number is of order unity; various calculations are performed for gaseous and supercritical argon to support the general validity of the theory. Excellent quantitative agreement is obtained with recent MD calculations for a dense supercritical Lennard-Jones fluid.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗