Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “microchannel plate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Performance of microchannel plate based detectors for <25 keV x rays: Monte Carlo simulations and comparisons with experimental results

We present the results of Monte Carlo simulations of the microchannel plate (MCP) response to x rays in the 250 eV to 25 keV energy range as a function of both x-ray energy and impact angle and their comparisons with the experimental results from the X8A beamline at the National Synchrotron Light Source at Brookhaven National Laboratory. Incoming x rays interact with the lead glass of the microchannel plate, producing photoelectrons. Transport of the photoelectrons is neglected in this model, and it is assumed that photoelectrons deposit all their energy at the point they are created. This deposition leads to the generation of many secondary electrons, some fraction of which diffuse to the MCP pore surface where they can initiate secondary electron cascades in the pore under an external voltage bias. X-ray penetration through multiple MCP pore walls is increasingly important above 5 keV, and the effect of this penetration on MCP performance is studied. In agreement with past measurements, we find that the dependence of MCP sensitivity with angle relative to the pore bias changes from a cotangent dependence to angular independence and then proceeds to a secant dependence as the x-ray energy increases. We also find that with the increasing x-ray energy, the MCP gain sensitivity as a function of bias voltage decreases. The simulations also demonstrate that for x rays incident normal to the MCP surface, spatial resolution shows little dependence on the x-ray energy but degrades with the increasing x-ray energy as the angle of incidence relative to the surface normal increases. This agrees with experimental measurements. Simulation studies have also been completed for MCPs gated with a subnanosecond voltage pulse. In this work, we find that the optical gate profile width increases as the x-ray energy is increased above 5 keV, a consequence of increased x-ray penetration at energies >5 keV. Simulations of the pulsed dynamic range show that the dynamic range varies between ~100 and 1000 depending on x-ray energy and peak voltage.

47 OTHER INSTRUMENTATION↗

Microchannel Plate Imaging Detectors for the Ultraviolet

There has been significant progress over the last few years in the development of technologies for microchannel plate imaging detectors in the Ultraviolet (UV). Areas where significant developments have occurred include enhancements of quantum detection efficiency through improved photocathodes, advances in microchannel plate performance characteristics, and development of high performance image readout techniques. The current developments in these areas are summarized, with their applications in astrophysical instrumentation.

Siegmund, O. H. W.↗

Dead-time effects in microchannel-plate imaging detectors

The observed counting rates of microchannel plate (MCP) based detectors for high resolution observations of celestial EUV and X-ray sources vary over many orders of magnitude; the counting capability of an individual channel, however, is not high, and is associated with dead-times ranging from 0.1 msec to 1 sec. The dead-time increases with the area illuminated; attention is presently given to laboratory determinations of the count rate characteristics of a MCP detector as a function of illuminated area, and a model is developed for these results' use in the interpretation of space observations.

Zombeck, Martin V.↗

Performance characteristics of a new helical-channel microchannel plate

An advanced version of the 'helical-channel' microchannel plate (MCP) is presented. This MCP is composed of four channels per fiber with each channel having a diameter of 50 microns. The dynamic range, pulse-height distribution, and gain characteristics of this MCP are discussed. It is found that increasing the twist density of the channels makes it possible to increase the detection efficiency and further improve the suppression of ion-feedback providing a tighter saturated pulse-height distribution and improved high-voltage characteristics.

Slater, David C.↗

Investigations of bonded and curved microchannel plate stacks

The technique of fusing, or bonding, individual microchannel plate (MCP) stacks together offers the possibility of improving the uniformity of MCP stack operating characteristics and provides a convenient monolithic format. Here, the effectiveness of bonded MCP stacks and stacks of MCPs with curved surfaces is investigated to determine if MCP requirements for future astrophysical detectors can be achieved. The results show that both configurations give superior MCP performance characteristics. However, some problems remain with regard to the fabrication of bonded MCP stacks resulting in poor flat field characteristics and increased background.

Siegmund, O. H. W.↗

Microchannel plate life tests

The behavior of the gain of a microchannel plate (MCP) during operation of the latter at moderate output currents was investigated. The total charge per unit area, Q, extracted from the MCP is shown to be the relevant quantity for evaluating MCP performance. The shape of the gain versus Q curve provides information on the gain decay process. Long periods of stable gain, frequently exhibited by channeltrons, were not observed in the present experiment.

Sandel, B. R.↗

Investigation of large format microchannel plate Z configurations

The performance of triplet (Z) stacks of microchannel plates (MCPs) has been studied as a part of the instrument development for the Extreme Ultraviolet Explorer (EUVE) satellite mission. Relatively large MCPs with a 60-mm diameter and having a large 80:1 channel length to diameter (L:D) ratio were used in several configurations. The MCPs were used in the EUVE prototype imaging detector to provide more than 512 x 512 pixels with low image distortion (less than 1 percent). The gain and pulse height characteristics of the MCPs were examined, showing that both high gains (more than 2 x 10 to the 7th) and tight output pulse height distributions (less than 30 percent FWHM) may be achieved. Simple distribution techniques have also allowed low intrinsic background event rates (less than 0.15 events per sq cm/s) to be obtained. Variation of the quantum efficiency of the MCPs over the wavelength range 160-1216 A has been investigated for a range of angles of incidence. The effect of temperature variations on MCP operating characteristics has also been evaluated.

Siegmund, O. H. W.↗

Delay line anodes for microchannel-plate spectrometers

A photon-counting readout system for microchannel-plate spectrometers is described that uses a delay line and timing circuit for the wavelength coordinate and a wedge-wedge charge division system for the orthogonal spatial coordinate. A novel zigzag layout allows these two anode patterns to coexist on a common planar substrate and share the charge from each photoevent, thereby simultaneously localizing the photon in each of its two dimensions. Unlike wedge-and-strip or resistive anode encoders, the delay line offers a spatial resolution that is relatively independent of the format length. Unlike discrete anode systems, the delay line readout system's complexity is also independent of the field of view size. These facts make the delay line readout system advantageous in large format detectors. A testbed detector having a delay line propagation speed of 2.2 mm/ns and a time resolution of 33 ps FWHM has been assembled. Ultraviolet testing shows a Gaussian event distribution having a 70-micron FWHM width; the readout system blur contribution is less than 50-micron FWHM.

Lampton, M.↗

A simple approach for characterizing the spatially varying sensitivity of microchannel plate detectors

Herein we present a simple approach to characterize the spatial variation of the gain in microchannel plate (MCP) coupled to phosphor detectors using single electron or photon hits. The technique is easy to implement and general enough to be extended to other kinds of detectors. We demonstrate the efficacy of the approach on both laboratory and Monte Carlo generated datasets. Furthermore, we use the approach to measure the variation in gain over time as the MCP is exposed to an increasing number of electrons.

47 OTHER INSTRUMENTATION↗

Delay-Line Anode For Microchannel-Plate Spectrometer

Photon-counting read-out system for microchannel-plate spectrometer includes delay line and timing circuit to measure wavelength coordinate and wedge/wedge charge-division system to measure orthogonal spatial coordinate. System proves advantageous for portable two-dimensional spectrometers having large image planes and for which design requirements include simplicity, reliability, low power consumption, and low mass.

Lampton, M.↗

Characteristics of square pore and low noise microchannel plate stacks

An evaluation is conducted of several square-pore microchannel plates (MCPs) with either 25- or 85-micron diameter pores and 80:1 or 50:1 channel length/diameter ratio. Flat field measurements show that the 25-micron-pored MCPs, unlike those with 85-micron pores, exhibit periodic modulation; this may be due to the MCP stacking configurations. Attention is given to the relative quantum detection efficiency advantages of the two MCPs.

Siegmund, Oswald H. W.↗

Performance comparison of high speed microchannel plate photomultiplier tubes

The transit time spread characteristics of high speed microchannel photomultipliers has improved since the upgrade of the NASA CDSLR network to MCP-PMT's in the mid-1980's. The improvement comes from the incorporation of 6 micron (pore size) microchannels and offers significant improvement to the satellite ranging precision. To examine the impact on ranging precision, two microchannel plate photomultiplier tubes (MCP-PMT) were evaluated for output pulse characteristics and temporal jitter. These were a Hamamatsu R 2566 U-7 MCP-PMT (6 micron) and an ITT 4129f MCP-PMT (12 micron).

Varghese, Thomas↗

Study of Static Microchannel Plate Saturation Effects for the Fast Plasma Investigation Dual Electron Spectrometers on NASA's Magnetospheric MultiScale Mission

Imaging detecting systems based on microchannel plates (MCPs) are the most common for low energy plasma measurements for both space borne and ground applications. One of the key parameters of these detection systems is the dynamic range of the MCP's response to the input fluxes of charged particles. For most applications the dynamic range of the linear response should be as wide as possible. This is especially true for the Dual Electron Spectrometers (DESs) of the Fast Plasma Investigation (FPI) on NASA's Magnetospheric MultiScale (MMS) mission because a wide range of input fluxes are expected. To make use of the full available dynamic range, it is important to understand the MCP response behavior beyond the linear regime where the MCPs start to saturate. We have performed extensive studies of this during the characterization and calibration of the DES instruments and have identified several saturation effects of the detection system. The MCP itself exhibits saturation when the channels lack the ability to replenish charge sufficiently rapidly. It is found and will be shown that the ground system can significantly impact the correct measurement of this effect. As the MCP starts to saturate, the resulting pulse height distribution (PHD) changes shape and location (with less pulse height values), which leads to truncation of the PHD by the threshold set on the detection system discriminator. Finally, the detection system pulse amplifier exhibits saturation as the input flux drives pulse rates greater than its linear response speed. All of these effects effectively change the dead time of the overall detection system and as a result can affect the quality and interpretation of the flight data. We present results of detection system saturation effects and their interaction with special emphasis on the MCP related effects.

detecting system↗

Extreme ultraviolet quantum efficiency of opaque alkali halide photocathodes on microchannel plates

Comprehensive measurements are presented for the quantum detection efficiency (QDE) of the microchannel plate materials CsI, KBr, KCl, and MgF2, over the 44-1800 A wavelength range. QDEs in excess of 40 percent are achieved by several materials in specific wavelength regions of the EUV. Structure is noted in the wavelength dependence of the QDE that is directly related to the valence-band/conduction-band gap energy and the onset of atomic-like resonant transitions. A simple photocathode model allows interpretation of these features, together with the QDE efficiency variation, as a function of illumination angle.

Siegmund, O. H. W.↗

Planar double delay-line readout technique for microchannel plate detectors

A two-dimensional position-sensitive electrical readout system for microchannel plate detectors in spectroscopic applications has been devised. Two adjacent parallel coplanar delay lines are used. The difference in time of arrival of the electron event signal between the ends of the delay lines gives one coordinate of the centroid of each event pulse. The ratio of the event amplitudes on the two delay lines gives the orthogonal coordinate by means of charge partitioning. The performance characteristics of operational double delay lines for systems of this type are presented.

Lampton, M.↗

Imaging at soft X-ray wavelengths with high-gain microchannel plate detector systems

Multianode microchannel array (MAMA) detector systems with formats of 256 x 1024 pixels and active areas of 6 x 26 mm are now under evaluation at visible, UV and soft X-ray wavelengths. Very-large-format versions of the MAMA detectors with formats of 2048 x 2048 pixels and active areas of 52 x 52 mm are under development for use in the NASA Goddard Space Telescope Imaging Spectrograph (STIS). Open-structure versions of these detectors with Cs I photocathodes can provide a high-resolution imaging capability at EUV and soft X-ray wavelengths and can deliver a maximum count rate from each array in excess of 10 to the 6th counts/s. In addition, these detector systems have the unique capability to determine the arrival time of a detected photon to an accuracy of 100 ns or better. The construction, mode of operation, and performance characteristics of the MAMA detectors are described, and the program for the development of the very-large-format detectors is outlined.

Timothy, J. Gethyn↗

Multi-Anode Square Microchannel Plate Photomultiplier Tube

Photek has developed a high performance 4096-anode photomultiplier tube using microchannel plates as the gain medium. Additionally, the detector has been designed in a square format to maximise the active area and allow for easy tiling to cover large areas using multiple units. This paper analyses the detector performance in terms of gain and photocathode uniformity, single photon timing accuracy, count rate capability, cross talk and magnetic field susceptibility.

47 OTHER INSTRUMENTATION↗

A new approach to large area microchannel plate manufacture

Methods of manufacture of twisted single elements as the base for producing microchannel plates (MCP) are discussed. Initial evaluations validated the off-axis channel concept and no technological roadblocks were identified which would prevent fabrication of high gain, high spatial resolution, large format MCP's using this technique. The first MP's have operated at stable gains of 3 million with pulse height resolution superior to results obtained by standard chevron MCP's.

Source record↗