Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “material analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Historical Material Analysis of DC745U Pressure Pads

As part of the Enhance Surveillance mission, it is the goal to provide suitable lifetime assessment of stockpile materials. This report is an accumulation of historical publication on the DC745U material and their findings. It is the intention that the B61 LEP program uses this collection of data to further develop their understanding and potential areas of study. DC745U is a commercially available silicone elastomer consisting of dimethyl, methyl-phenyl, and methyl-vinyl siloxane repeat units. Originally, this material was manufactured by Dow Corning as Silastic® DC745U at their manufacturing facility in Kendallville, IN. Recently, Dow Corning shifted this material to the Xiameter® brand product line. Currently, DC745U is available through Xiameter® or Dow Corning's distributor R. D. Abbott Company. DC745U is cured using 0.5 wt% vinyl-specific peroxide curing agent known as Luperox 101 or Varox DBPH-50. This silicone elastomer is used in numerous parts, including two major components (outer pressure pads and aft cap support) in the W80 and as pressure pads on the B61. DC745U is a proprietary formulation, thus Dow Corning provides limited information on its composition and properties. Based on past experience with Dow Corning, DC745U is at risk of formulation changes without notification to the costumer. A formulation change for DC745U may have a significant impact because the network structure is a key variable in determining material properties. The purpose of this report is to provide an overview of historical DC745U studies and identify gaps that need to be addressed in future work. Some of the previous studies include the following: 1. Spectroscopic characterization of raw gum stock. 2. Spectroscopic, thermal, and mechanical studies on cured DC745U. 3. Nuclear Magnetic Resonance (NMR) and solvent swelling studies on DC745U with different crosslink densities. 4. NMR, solvent swelling, thermal, and mechanical studies on thermally aged DC745U. 5. NMR, solvent swelling, thermal, and mechanical studies on radiolytically aged DC745U. Each area is reviewed and further work is suggested to improve our understanding of DC745U for systems engineering, surveillance, aging assessments, and lifetime assessment.

36 MATERIALS SCIENCE↗

Cameco UO 3 Materials Analysis

Uranium trioxide (UO 3 ) was characterized using a variety of techniques to better understand its physical properties. Scanning electron microscope (SEM) images were collected to examine particle morphology, which consisted of semi-spherical particles that tended to agglomerate before sonication. Particle size analysis revealed a singular mode distribution with a mean particle size of 43.0 {micro}m. After sonication a bimodal distribution was produced with peak particle sizes at 0.226 μm and 9.43 μm. The O/U ratio was measured to be 3.09 by Cameco in 2009, by gravimetric analysis. X-ray diffraction (XRD) showed that the sample was mostly Υ-UO 3 (87.1%) with a small amount of UO 3 ̣ 0.80 H 2 O (12.9%). Bulk and tap densities were determined to be 3.678 ±} 0.2 and 4.81 ± 0.2 g/cm 3 }, respectively (crystalline density is 7.3 g/cm 3 ). The stoichiometry was measured to be 2.99 in 2012.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Delivering real-time multi-modal materials analysis with enterprise beamlines

Contemporary advancements in low-cost automation and computation, reduced barrier to entry in developing artificial intelligence/machine learning (AI/ML), and increased ability to represent complex materials in digital form have led to a number of accelerated materials discovery platforms. However, many of these approaches operate with completely rigid vertical integration in an isolated feedback loop using limited modalities. In order to make a substantial impact on discovering new energy materials, AI-driven experiments must operate collaboratively with each other and researchers and over multiple measurement modalities. Herein, we describe the potential for an “internet of things” approach to self-driving enterprise beamlines that merges core information technologies, robotics, and multi-modal AI. The approach will enable full utility of light sources, collaborate effectively with other remote materials acceleration platforms, and help stride toward the world’s energy future.

36 MATERIALS SCIENCE↗

Material analysis of metal hydrides for bulk hydrogen storage

The United States Department of Energy (DOE) Hydrogen Storage Engineering Center of Excellence (HSECoE), 2009–2014, was established to evaluate the viability of material-based hydrogen storage for light duty vehicles. The HSECoE concluded that there were no metal hydrides that simultaneously met the DOE targets for gravimetric and volumetric capacity, and rate of onboard refueling. However, it was noted by the DOE that potential applications existed for stationary hydrogen storage systems. An application of particular interest is using a metal-hydride to store a hydrogen supply for fuel cell backup power to a 5 MWe data center. A generalized numerical model that coupled mass and energy conservation, chemical kinetics and thermodynamics was developed to simulate the discharge process for a given metal-hydride. The model was applied to an interstitial and a complex metal-hydride. In conclusion, it was found that the interstitial metal-hydride, which is discharged by a pressure swing is preferrable in a practical sense to the complex metal-hydride, which requires a temperature swing discharge process.

08 HYDROGEN↗

Neutron tomographic analysis: Material characterization of silver and electrum coins from the 6th and 5th centuries BCE

Neutron tomography was applied to study a set of Greek silver coins and a single Lydian electrum coin minted in the 6 and 5th centuries BCE. The investigation was conducted at the new neutron imaging station DINGO at ANSTO in order to demonstrate capabilities and to explore limits of this non-invasive method in characterizing numismatic materials. From the reconstructed volume of each sample, the morphology, porosity, inclusions, and presence of composite structures can be revealed and evaluated. This information can be used to elucidate ancient minting technology and to prove authenticity. Moreover, the state of conservation, corrosion processes and attempts to repair the coins can be determined. - Highlights: •Pre-Roman coins •Non-destructive analysis •Neutron tomography: limit and capability.

36 MATERIALS SCIENCE↗

Material analysis of Bottom ash from waste-to-energy plants

Bottom ash (BA) from waste-to-energy (WtE) plants contains valuable components, particularly ferrous (Fe) and non-ferrous (NFe) metals, which can be recovered. To assess the resource recovery potential of BA in the Czech Republic, it was necessary to obtain its detailed material composition. This paper presents the material composition of BA samples from all three Czech WtE plants. It was found that the BA contained 9.2–22.7% glass, 1.8–5.1% ceramics and porcelain, 0.2–1.0% unburnt organic matter, 10.2–16.3% magnetic fraction, 6.1–11.0% Fe scrap, and 1.3–2.8% NFe metals (in dry matter). The contents of individual components were also studied with respect to the BA granulometry and character of the WtE waste collection area.

54 ENVIRONMENTAL SCIENCES↗

Film Deposition, Cryogenic RF Testing and Materials Analysis of a Nb/Cu Single Cell SRF Cavity

In this study, we present preliminary results on using a cathodic-arc-discharge Nb plasma ion source to establish a Nb film-coated single-cell Cu cavity for SRF research. The polycrystalline Cu cavity was fabricated and mirror-surface-finished by a centrifugal barrel polishing (CBP) process at Jefferson Lab. Special pre-coating processes were conducted, in order to create a template-layer for follow-on Nb grain thickening. A sequence of cryogenic RF testing demonstrated that the Nb film does show superconductivity. But the quality factor of this Nb/Cu cavity is low as a result of high residual surface resistance. We are conducting a thorough materials characterization to explore if some microstructural defects or hydrogen impurities, led to such a low quality factor.

Zhao, Xin↗

Improving qubit coherence time through detailed materials analysis

This study investigates the defects, imperfections, and variations in superconducting Nb thin films deposited on sapphire substrates. Two samples, W114 and W118, were fabricated using DC Magnetron Sputtering and Electron Cyclotron Resonance (ECR), respectively. Each sample was analyzed at five distinct spots to compare elemental homogeneity and thickness variations. Scanning Electron Microscopy (SEM) was employed to examine surface morphology, while Energy Dispersive X-ray Spectroscopy (EDS) and X-ray Photoelectron Spectroscopy (XPS) provided elemental and chemical state analyses. SEM revealed distinct structures in W114 and a uniform surface in W118. EDS showed higher aluminum and oxygen signals in W118, indicating a thicker film. XPS detected a higher Nb₂O₅ signal in W118, attributed to a thicker oxygen layer. These findings highlight the critical role of precise material characterization in advancing quantum computing technologies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

MHK Levelized Cost of Energy (LCOE) Guidance and Techno-Economic Analysis Materials

Useful information and tools for calculating the Levelized Cost of Energy (LCOE) and MHK Cost Breakdown Structure. Includes a structure for calculating the capital expenditures and operating costs of a marine energy technology or device, reference resource data for both wave and tidal, and LCOE reporting guidance. These tools are meant to be used to help calculate the Levelized Cost of Energy (LCOE) for an MHK or MRE technology or device.

16 TIDAL AND WAVE POWER↗

Improving Qubit Coherence Time Through Detailed Materials Analysis

This study investigates the defects, imperfections, and variations in Nb thin films deposited on sapphire substrates. Two samples, W114 and W118, were fabricated using DC Magnetron Sputtering and Electron Cyclotron Resonance (ECR), respectively. Each sample was analyzed at five distinct spots to compare elemental homogeneity and variations in oxide layers. Scanning Electron Microscopy (SEM) was employed to examine surface morphology, while Energy Dispersive X-ray Spectroscopy (EDS) and X-ray Photoelectron Spectroscopy (XPS) provided elemental and chemical state analyses. SEM revealed distinct structures in W114 and a uniform surface in W118. EDS showed higher aluminum signals in W118, indicating a thinner film in comparison to W114. XPS detected a higher Nb₂O₅ signal in W118, in comparison to W114, which can be attributed to the presence of a thicker Nb₂O₅ layer in W118. These findings highlight the critical role of precise material characterization in advancing quantum computing technologies.

Rosado Bonilla, Cristy M.↗

Examining Graphite Degradation in Molten Salt Environments: A Chemical, Physical, and Material Analysis

Molten-salt reactors (MSRs) are Generation IV nuclear reactors that use liquid salt as a coolant and/or fuel. In several MSR designs, graphite serves as a moderator and/or reflector. However, due to limited experimental data and operational experience, our understanding of graphite behavior in molten salt environments remains incomplete. This report aims to identify the degradation mechanisms of nuclear graphite in MSRs, detail the mechanisms of each factor, and provide an initial assessment of their impact on the structural integrity of graphite components. This assessment is based on an extensive literature review and insights from subject matter experts. Furthermore, given the limited data, a modeling strategy using existing Grizzly software is proposed for a more thorough analysis where appropriate. Additionally, it presents mitigation strategies where applicable. The report covers physical degradation mechanisms such as infiltration, erosion, and abrasion, as well as chemical degradation mechanisms including fluorination, intercalation, corrosion, and oxidation. Molten salt can infiltrate the porous structure of graphite, leading to several detrimental effects. Entrapment of fissile products within the graphite pores can cause radiation damage and could pose challenges in the handling and disposal of contaminated components. The differential thermal expansion between the infiltrated salt and graphite, along with internal stress from pressurized molten salt and volumetric heating, can compromise the structural integrity of graphite. To mitigate these effects, employing ultra-fine graphite grades and applying sealants and coatings are effective strategies. A computational model based on coupled solid mechanics and heat transfer phenomena could be used to predict the internal stresses using Grizzly software. In pebble-bed MSRs, graphite fuel pebbles can cause abrasion against reactor components due to friction and wear. The severity of wear is influenced by various factors such as temperature, environment, and the presence of lubricants. Tribological studies reveal that higher temperatures and molten salt environments, such as FLiBe, significantly reduce wear rates compared to dry conditions. Additionally, the chemical composition of the salt can further optimize graphite's tribological performance. Long-term wear effects can be modeled by incorporating surface defects into the geometry and predict stresses under thermal and radiation effects using Grizzly software. Chemical degradation of graphite in a molten salt environment can occur through fluorination and intercalation. Fluorination can occur via replacement of hydrogen or oxygen atoms, or at the active sites, but does not cause structural degradation. Intercalation, on the other hand, can lead to exfoliation, where layers of graphite separate and peel away, damaging the graphite. Protective coatings can enhance graphite's resistance to intercalation. Graphite generally exhibits good chemical stability in molten salt environments, though it can corrode under specific conditions, particularly in the presence of impurities or oxidants. Studies have shown that protective coatings, such as plasma-sprayed partially stabilized zirconia (PSZ), can effectively prevent such degradation. Corrosion behavior varies significantly with different graphite grades and coating applications, underscoring the need for detailed studies on uncoated and coated graphite to understand and mitigate corrosion mechanisms in MSRs. Research indicates that the presence of oxidants and impurities can accelerate graphite degradation in molten salts, making it essential to explore acceptable impurity limits. Oxidation is another critical degradation mechanism, leading to weight loss and structural damage due to the formation of CO and CO 2 from the reaction of carbon atoms with oxygen. This process creates new porosity and compromises graphite's integrity. While extensive research on graphite oxidation has been conducted for gas-cooled reactors, studies specific to MSRs are limited. Findings from the coal industry suggest that molten alkali metal salts can significantly accelerate graphite oxidation, a hypothesis worth exploring for fluoride salts in MSRs. Understanding oxidation behavior in MSRs is vital for developing protective measures. The analysis of post-irradiated graphite from the MSRE experiment demonstrated exceptional chemical compatibility with molten fluoride salt, suggesting that the extent of chemical attack on graphite largely depends on the salt's infiltration capability. Therefore, the use of ultra-fine grade graphite could help mitigate chemical degradation effects. Existing oxidation modeling capabilities in Grizzly, which use reaction-diffusion equations to model graphite-air interactions, could be adapted to simulate the chemical degradation effects of graphite in molten salt environments.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

PUMP-STORAGE HYDROPOWER DESIGN IN A WASTEWATER TREATMENT FACILITY WITH AN AERATING RUNNER, ADDITIVE MANUFACTURED MATERIAL ANALYSIS, AND TESTING OF HYDROKINETIC TURBINE RUNNER.

The feasibility and design of a novel pumped storage system in a wastewater treatment facility is investigated. Analysis covers the added benefit of aeration, costs, and specifications. For the given sub-megawatt system, off-the-shelf runner designs are not available. This research builds on an existing pump-turbine research and design through a combination of introducing aeration into the operating processes, analysis of large format metal additive manufacturing, and testing and validation of a hydrokinetic turbine runner that uses the same response surface optimization methodology as the discussed pump-turbine design. Two concepts are generated and proposed along with a baseline scenario. Two potential site locations are provided with relevant information The Stickney Wastewater Reclamation Plant and The Navy Wastewater Treatment Plant, Joint Base Pearl Harbor-Hickam, Oahu Hawaii. Results show that aeration is the primary benefit of such a system. The system is capable of meeting the required dissolved oxygen (DO) levels in wastewater treatment. The system produces volume averaged DO levels between 1.2 and 1.4 mg/l. The system is shown to be a scalable open-loop system that can be sized for application. Area requirements of the system are acceptable due to the use of a single pedestal elevated tank The implementation timeline and nuances of this system are largely unknown. In attempt to reduce costs, advanced manufacturing methods are investigated. Investigation into advanced methods showed that mechanical properties of additive manufactured metals using a GMAW system produce equal results to wrought materials and have the potential to produce custom wear properties.

additive manufacturing↗

Enhanced Functionality for Materials Analysis in the DTEM

The recent explosion in the use of pump–probe studies on picosecond and shorter timescales to investigate structural and electronic phase transitions and the dynamics of chemical reactions has been based largely on laser–induced reactions coupled with laser interrogation techniques, or on laser induced reactions coupled with synchrotron radiation interrogation techniques. Much less attention has been given to approaches based on laser–induced (or electron–beam–induced) reactions coupled with electron interrogation methods, despite the fact that electron sources are brighter, and their interactions with matter stronger (thereby giving higher signal levels). The use of electrons as temporal probes has great potential for the study of complex transient events not only because of the high temporal resolution attainable by ultrafast electron diffraction (UED) but also the potential for direct high spatial resolution imaging using dynamic transmission electron microscopy (DTEM). However, taking this potential for electron interrogation methods and turning it into a routine nanoscale characterization technique requires several key aspects of the instrumentation used for electron microscopy/diffraction to be optimized. In this work, several approaches to instrument optimization for DTEM and UED (to be performed in the same instrument) are being addressed.

99 GENERAL AND MISCELLANEOUS↗

An outbreak of renal failure in asian dogs due to s-triazine adulteration of pet food raw material: Analysis of unique, green kidney stones formed as a result

Renoliths were removed at necropsy from dogs that had died from acute kidney injury in Asia in 2004 and submitted to our laboratories for analysis including elemental composition, mass spectrometry, and microprobe analysis. The presence of a mixed s-triazine matrix comprising melamine, cyanuric acid, and ammelide, but no detectable ammeline, was found in the stone samples we analyzed. The unusual and unique green coloration of these stones was determined to be due to the presence of biliverdin. The occurrence of these green stones distinguished the 2004 incident from another incident in 2007 in the USA and other reported cases. The presence of crystals was reported in renal tubules and collecting ducts in both outbreaks, but no stones were reported in the 2007 incident. Here, this difference suggested a variation in the disease process caused by mixed s- triazine ingestion. Careful monitoring of food additives is warranted to prevent future problems in animals and humans.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗