Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “manifold sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Water quality monitor

The preprototype water quality monitor (WQM) subsystem was designed based on a breadboard monitor for pH, specific conductance, and total organic carbon (TOC). The breadboard equipment demonstrated the feasibility of continuous on-line analysis of potable water for a spacecraft. The WQM subsystem incorporated these breadboard features and, in addition, measures ammonia and includes a failure detection system. The sample, reagent, and standard solutions are delivered to the WQM sensing manifold where chemical operations and measurements are performed using flow through sensors for conductance, pH, TOC, and NH3. Fault monitoring flow detection is also accomplished in this manifold assembly. The WQM is designed to operate automatically using a hardwired electronic controller. In addition, automatic shutdown is incorporated which is keyed to four flow sensors strategically located within the fluid system.

West, S.↗

Nanoscale Surface Plasmonics Sensor With Nanofluidic Control

Conventional quantitative protein assays of bodily fluids typically involve multiple steps to obtain desired measurements. Such methods are not well suited for fast and accurate assay measurements in austere environments such as spaceflight and in the aftermath of disasters. Consequently, there is a need for a protein assay technology capable of routinely monitoring proteins in austere environments. For example, there is an immediate need for a urine protein assay to assess astronaut renal health during spaceflight. The disclosed nanoscale surface plasmonics sensor provides a core detection method that can be integrated to a lab-on-chip device that satisfies the unmet need for such a protein assay technology. Assays based upon combinations of nanoholes, nanorings, and nanoslits with transmission surface plasmon resonance (SPR) are used for assays requiring extreme sensitivity, and are capable of detecting specific analytes at concentrations as low as picomole to femtomole level in well-controlled environments. The device operates in a transmission mode configuration in which light is directed at one planar surface of the array, which functions as an optical aperture. The incident light induces surface plasmon light transmission from the opposite surface of the array. The presence of a target analyte is detected by changes in the spectrum of light transmitted by the array when a target analyte induces a change in the refractive index of the fluid within the nanochannels. This occurs, for example, when a target analyte binds to a receptor fixed to the walls of the nanochannels in the array. Independent fluid handling capability for individual nanoarrays on a nanofluidic chip containing a plurality of nanochannel arrays allows each array to be used to sense a different target analyte and/or for paired arrays to analyze control and test samples simultaneously in parallel. The present invention incorporates transmission mode nanoplasmonics and nanofluidics into a single, microfluidically controlled device. The device comprises one or more arrays of aligned nanochannels that are in fluid communication with inflowing and outflowing fluid handling manifolds that control the flow of fluid through the arrays. The array acts as an aperture in a plasmonic sensor. Fluid, in the form of a liquid or a gas and comprising a sample for analysis, is moved from an inlet manifold through the nanochannel array, and out through an exit manifold. The fluid may also contain a reagent used to modify the interior surfaces of the nanochannels, and/or a reagent required for the detection of an analyte.

Wei, Jianjun↗

Ethylene monitoring and control system

A system that can accurately monitor and control low concentrations of ethylene gas includes a test chamber configured to receive sample gas potentially containing an ethylene concentration and ozone, a detector configured to receive light produced during a reaction between the ethylene and ozone and to produce signals related thereto, and a computer connected to the detector to process the signals to determine therefrom a value of the concentration of ethylene in the sample gas. The supply for the system can include a four way valve configured to receive pressurized gas at one input and a test chamber. A piston is journaled in the test chamber with a drive end disposed in a drive chamber and a reaction end defining with walls of the test chamber a variable volume reaction chamber. The drive end of the piston is pneumatically connected to two ports of the four way valve to provide motive force to the piston. A manifold is connected to the variable volume reaction chamber, and is configured to receive sample gasses from at least one of a plurality of ports connectable to degreening rooms and to supply the sample gas to the reactive chamber for reaction with ozone. The apparatus can be used to monitor and control the ethylene concentration in multiple degreening rooms.

Nelson, Bruce N.↗

Ethylene monitoring and control system

A system that can accurately monitor and control low concentrations of ethylene gas includes a test chamber configured to receive sample gas potentially containing an ethylene concentration and ozone, a detector configured to receive light produced during a reaction between the ethylene and ozone and to produce signals related thereto, and a computer connected to the detector to process the signals to determine therefrom a value of the concentration of ethylene in the sample gas. The supply for the system can include a four way valve configured to receive pressurized gas at one input and a test chamber. A piston is journaled in the test chamber with a drive end disposed in a drive chamber and a reaction end defining with walls of the test chamber a variable volume reaction chamber. The drive end of the piston is pneumatically connected to two ports of the four way valve to provide motive force to the piston. A manifold is connected to the variable volume reaction chamber, and is configured to receive sample gasses from at least one of a plurality of ports connectable to degreening rooms and to supply the sample gas to the reactive chamber for reaction with ozone. The apparatus can be used to monitor and control the ethylene concentration in multiple degreening rooms.

Nelson, Bruce N.↗

Low gravity exothermic heating/cooling apparatus

A low gravity exothermic heating/cooling apparatus is disclosed for processing materials in space which includes an insulated casing and a sample support carried within the casing which support a sample container. An exothermic heat source includes a plurality of segments of exothermic material stacked one upon another to produce a desired temperature profile when ignited. The sample container is arranged within the core of the stacked exothermic heating material. Igniters are spaced vertically along the axis of the heating material to ignite the exothermic material at spaced points to provide total rapid burn and release of heat. To rapidly cool and quench the heat, a source of liquid carbon dixoide is provided which is conveyed through a conduit and a metering orifice into a distribution manifold where the carbon dioxide is gasified and dispersed around the exothermic heating material and the sample container via tubes for rapidly cooling the material sample.

Poorman, R. M.↗

Development and Experimental Evaluation of Passive Fuel Cell Thermal Control

To provide uniform cooling for a fuel cell stack, a cooling plate concept was evaluated. This concept utilized thin cooling plates to extract heat from the interior of a fuel cell stack and move this heat to a cooling manifold where it can be transferred to an external cooling fluid. The advantages of this cooling approach include a reduced number of ancillary components and the ability to directly utilize an external cooling fluid loop for cooling the fuel cell stack. A number of different types of cooling plates and manifolds were developed. The cooling plates consisted of two main types; a plate based on thermopyrolytic graphite (TPG) and a planar (or flat plate) heat pipe. The plates, along with solid metal control samples, were tested for both thermal and electrical conductivity. To transfer heat from the cooling plates to the cooling fluid, a number of manifold designs utilizing various materials were devised, constructed, and tested. A key aspect of the manifold was that it had to be electrically nonconductive so it would not short out the fuel cell stack during operation. Different manifold and cooling plate configurations were tested in a vacuum chamber to minimize convective heat losses. Cooling plates were placed in the grooves within the manifolds and heated with surface-mounted electric pad heaters. The plate temperature and its thermal distribution were recorded for all tested combinations of manifold cooling flow rates and heater power loads. This testing simulated the performance of the cooling plates and manifold within an operational fuel cell stack. Different types of control valves and control schemes were tested and evaluated based on their ability to maintain a constant temperature of the cooling plates. The control valves regulated the cooling fluid flow through the manifold, thereby controlling the heat flow to the cooling fluid. Through this work, a cooling plate and manifold system was developed that could maintain the cooling plates within a minimal temperature band with negligible thermal gradients over power profiles that would be experienced within an operating fuel cell stack.

Fuel Cells↗

From Apollo to Artemis: How Processing ANGSA Core Samples 73001/2 Can Help to Prepare for Future Sample Return Missions to the Moon and Beyond.

Introduction: Apollo Sample 73001/2 is a ~71cm long double drive tube consisting of an upper part (73002) and a lower part (73001) that contains regolith collected near Lara Crater at the Apollo 17 site, Station 3. The double drive tube is believed to have penetrated a lunar landslide deposit that was transported from the slope of the South Massif into the Taurus-Littrow Valley [1]. As part of the ANGSA (Apollo Next Generation Sample Analyses) initiative, preparing a preliminary examination (PE) catalog of 73001/2 is a crucial first step for the early identification of material types such as rock fragments and potential stratigraphy within the core. Many new curation and scientific tools such as X-ray computed tomography (XCT) [3], multi-spectral imaging [4], and gas extraction manifold with piercing tool [5-7], have been applied to the ANGSA core to benefit curation strategy, PE efforts, sample allocation to the planetary science community, and ultimately help to prepare for future sample return missions like Artemis. 73001/2 Preliminary Examination and Processing: Sample 73002 was successfully opened and extruded in Nov. 2019 and fully dissected at the end of 2021. Sample 73001 (Fig. 1) was successfully extruded in March 2022 after careful planning before opening the Core Sample Vacuum Container (CSVC) that was holding the drive tube of 73001. XCT, as part of PE, was used to scan the bottom and top part of the 73001 core tube within the CSVC prior to opening it to 1) facilitate non-destructive, rapid detection of any contamination potentials due to piercing of the CSVC during gas extraction [7]; and 2) to aid in the Artemis sample tool development and provide data on the knife edge seal of the CSVC. This knowledge will help us connect the mechanics of the implemented design (i.e., XCT data) to the performance of the seal (i.e., data on the gas samples will tell us how well the seal preserved the volatile record of lunar samples). Both type of information will feed forward into Artemis tool and storage strategies for future samples. Results and Lessons learned: The XCT data of the CSVC and core tube within showed that the bottom Teflon cap was not pierced during gas extraction (Fig. 1c) and thus, the sample integrity remained guaranteed during piercing and subsequent gas extraction. However, the XCT scan of the top of the core (Fig. 1b) revealed that the drive tube was overfilled with lunar soil and the tool that keeps the soil constrained within the drive tube was not fully deployed. These preliminary data allowed us to implement the necessary steps to prevent loss of sample integrity, including any potential stratigraphy shifts during extrusion. Processing Apollo core 73001/2, creating an informative PE catalog, and applying new and refined tools and technologies for sample analyses are invaluable activities that will assist in circumventing any potential pitfalls, aid in the characterization of samples, and help in the assessment of how well any lunar material has been collected and preserved in the past. This will aid in designing future sample collections and curation procedures and help to prepare for future human exploration and sampling missions such as Artemis. References: [1] Schmitt H. (2017) Icarus 298, 2-33. [3] Zeigler et al. (2021) LPSC 52nd, #2632; [4] Sun et al. (2021), LPSC 52nd, #1789; [5] Parai et al. (2021), LPSC 52nd #2665; [6] Schild et al. (2021) LPSC 52nd #1888; [7] McDonald (2022) ESL 2022.

ANGSA↗

Isotopic and Geochemical Investigation of Two Distinct Mars Analog Environments Using Evolved Gas Techniques in Svalbard, Norway

The 2010 Arctic Mars Analog Svalbard Expedition (AMASE) investigated two distinct geologic settings on Svalbard, using methodologies and techniques to be deployed on Mars Science Laboratory (MSL). AMASErelated research comprises both analyses conducted during the expedition and further analyses of collected samples using laboratory facilities at a variety of institutions. The Sample Analysis at Mars (SAM) instrument suite on MSL includes pyrolysis ovens, a gas-processing manifold, a quadrupole mass spectrometer (QMS), several gas chromatography columns, and a Tunable Laser Spectrometer (TLS). An integral part of SAM development is the deployment of SAM-like instrumentation in the field. During AMASE 2010, two parts of SAM participated as stand-alone instruments. A Hiden Evolved Gas Analysis- Mass Spectrometer (EGA-QMS) system represented the EGA-QMS component of SAM, and a Picarro Cavity Ring Down Spectrometer (EGA-CRDS), represented the EGA-TLS component of SAM. A field analog of CheMin, the XRD/XRF on MSL, was also deployed as part of this field campaign. Carbon isotopic measurements of CO2 evolved during thermal decomposition of carbonates were used together with EGA-QMS geochemical data, mineral composition information and contextual observations made during sample collection to distinguish carbonates formation associated with chemosynthetic activity at a fossil methane seep from abiotic processes forming carbonates associated with subglacial basaltic eruptions. Carbon and oxygen isotopes of the basalt-hosted carbonates suggest cryogenic carbonate formation, though more research is necessary to clarify the history of these rocks.

Svalbard↗

Fluorescence branching ratios in nitric oxide - Emission from the A2 Sigma(+) (v prime = 1)

The most complete set of branching ratios from the v-prime = 1 level of the A-state in NO measured to data is reported. The assumption that virtually all of the emitted radiation has been sampled is used to extract Franck-Condon factors from the v-prime = 1 manifold. A comparison with previously published results indicates that, except for the (1,0) band, there is reasonably good agreement.

Mcgee, T. J.↗

Analysis of N-Nitrosodimethylamine and N-Nitrodimethylamine in Groundwater

A method for the analytical determination of N-nitrosodimethylamine (NDMA) and N-nitrodimethylamine (DMN) at parts-per-trillion (ppt) concentrations in groundwater is reported. The method uses a solid phase extraction (SPE) cartridge containing 2 g of activated coconut charcoal to extract a 500-mL water sample. NDMA and DMN are eluted from the SPE cartridge using acetone. The acetone is concentrated and brought to a final volume of 1.0 mL, which results in a theoretical 500-fold concentration of the analytes. The extracts are analyzed by gas chromatography (GC) with a nitrogenphosphorous detector (NPD), which is a highly sensitive and relatively inexpensive technique. The measured extraction efficiencies averaged 61 percent for NDMA and 74 percent for DMN. Extraction efficiencies were independent of NDMA and DMN concentrations from 40 to 2000 ppt. Several samples could be extracted then analyzed in a single day with the use of an extraction manifold and GC autosampler. A reporting limit of 10 ppt for NDMA and DMN was achieved. The MDLs for NDMA and DMN were 6.4 and 5.8 ppt, respectively. A typical turn-around time from beginning of extraction to reporting was 4 h. The method avoids the use of halogenated solvents, such as dichloromethane, and subsequent solvent exchange procedures necessary for use of the NPD detector.

Greene, Ben↗

Process and apparatus for analyzing specimens for the presence of microorganisms therein

Microorganisms in a specimen are detected, identified, and enumerated by introducing the specimen into a sampling cartridge and diluting the specimen with a known volume of water within the cartridge. The cartridge has a manifold and several cassettes attached to the manifold. Each cassette contains a serpentine flow channel having a series of filters therein and a detection cell located downstream from each filter. The flow channel in each cassette also contains a culture medium which is freeze dried and is highly selective in the sense that it promotes the growth of one type of microorganism, but not others. The mixture of the specimen and water flows from the manifold into the flow channel of each cassette where it rehydrates the culture medium therein and further flows through the filters. Each filter removes a known proportion of the microorganisms from the mixture of specimen, water and medium, thereby effecting a serial dilution. After the cassettes are heated to incubate the microoganisms, the detection cells are observed for growth of the microorganisms therein which is manifested in a change in the light transmitting characteristics of the mixtures within the cells.

Aldridge, Jr., Clifton↗

Sample Processor for Life on Icy Worlds (SPLIce): Design and Test Results

We report the design, development, and testing of the Sample Processor for Life on Icy Worlds (SPLIce) system, a microfluidic sample processor to enable autonomous detection of signatures of life and measurements of habitability parameters in Ocean Worlds. This monolithic fluid processing-and-handling system (Figure 1; mass 0.5 kg) retrieves a 50-L-volume sample and prepares it to supply a suite of detection instruments, each with unique preparation needs. SPLIce has potential applications in orbiter missions that sample ocean plumes, such as found in Saturns icy moon Enceladus, or landed missions on the surface of icy satellites, such as Jupiters moon Europa. Answering the question Are we alone in the universe? is captivating and exceptionally challenging. Even general criteria that define life very broadly include a significant role for water [1,2]. Searches for extinct or extant life therefore prioritize locations of abundant water whether in ancient (Mars), or present (Europa and Enceladus) times. Only two previous planetary missions had onboard fluid processing: the Viking Biology Experiments [3] and Phoenixs Wet Chemistry Laboratory (WCL) [4]. SPLIce differs crucially from those systems, including its capability to process and distribute L-volume samples and the integration autonomous control of a wide range of fluidic functions, including: 1) retrieval of fluid samples from an evacuated sample chamber; 2) onboard multi-year storage of dehydrated reagents; 3) integrated pressure, pH, and conductivity measurement; 4) filtration and retention of insoluble particles for microscopy; 5) dilution or vacuum-driven concentration of samples to accommodate instrument working ranges; 6) removal of gas bubbles from sample aliquots; 7) unidirectional flow (check valves); 8) active flow-path selection (solenoid-actuated valves); 9) metered pumping in 100 nL volume increments. The SPLIce manifold, made of three thermally fused layers of precision-machined cyclo-olefin polymer, supports all fluidic components (Figure 1) and integrated microchannels (125 x 250 m). Fluid is pumped by a stepper-motor-driven pump (Lee Co.). The functionality of the integrated MEMS pressure sensor (Honeywell) and passive check valves (Figure 2) were tested in conjunction with our newly designed integral bubble traps (Figure 3) and hydrophobic membrane-based concentrator (Figure 4). The concentrator (initially tested as a standalone component) demonstrated 5-fold vacuum-evaporative concentration. Polyethylene fused bead beds (PEFBBs; 50 porosity) store drylyophilized buffers, calibrants, and fluorescent dyes, and also promote mixing of sample with calibrant, dye, or H2O. Software-controlled automated tests demonstrated successful 1) fluid delivery to each component 2) valve and pump synchronization 3) sample aliquot delivery to instrument interface ports, and 4) rehydration of vacuum-dried fluorescent dye. In Figure 5, fluorescein on PEFBBs was rehydrated for 15 min using a pump-delivered water aliquot; it is displaced as H2O enters the bottom of the channel and pushes the dye into a check valve. Ultimately, SPLIce will fluorescently label amino acids in the sample for microchip-based electrophoretic (MCE) chiral separation and detection to seek and quantify key organic bio-signatures [5]; it will also deliver sample to a microfluidic version of WCL (mWCL) to measure soluble ions and redox-active species.

Life detection↗

Effect of degree of fuel vaporization on emissions for a premixed-prevaporized combustor system

The impact of the degree of fuel vaporization upon emission from a flametube combustor was studied using an inlet air pressure of 3 x 10 to the 5th power pascals, inlet air temperatures of 600K and 700K, a reference velocity of 35 meters per second and equivalence ratios of .6 and .72 using Jet A fuel. Incoming air was preheated to temperatures from 600K to 700K by a nonvitiating preheater. Jet A fuel was injected into this airstream through two different fuel injectors manifolded together and mounted in series upstream of a watercooled preforated plate flameholder. The fuel-air mixture burned in a watercooled combustor section. Samples of the fuel-air mixture upstream of the flameholder were obtained for analysis to determine the local degree of fuel vaporization and the fuel-air ratio. Samples of the combustion products were analyzed to determine gaseous emissions. The effects of vaporization on carbon monoxide and nitric on carbon monoxide and nitric oxide emissions are presented.

Cooper, L. P.↗

Topological analysis of chaotic orbits: Revisiting Hyperion

There is emerging interest in the possibility of chaotic evolution in astrophysical systems. To mention just one example, recent well-sampled ground-based observations of the Saturian satellite Hyperion strongly suggest that it is exhibiting chaotic behavior. We present a general technique, the method of close returns, for the analysis of data from astronomical objects believed to be exhibiting chaotic motion. The method is based on the extraction of pieces of the evolution that exhibit nearly periodic behavior-episodes during which the object stays near in phase space to some unstable periodic orbit. Such orbits generally act as skeletal features, tracing the topological organization of the manifold on which the chaotic dynamics takes place. This method does not require data sets as lengthy as other nonlinear analysis techniques do and is therefore well suited to many astronomical observing programs. Well sampled data covering between twenty and forty characteristic periods of the system have been found to be sufficient for the application of this technique. Additional strengths of this method are its robustness in the presence of noise and the ability for a user to clearly distinguish between periodic, random, and chaotic behavior by inspection of the resulting two-dimensional image. As an example of its power, we analyze close returns in a numerically generated data set, based on a model for Hyperion extensively studied in the literature, corresponding to nightly observations of the satellite. We show that with a small data set, embedded unstable periodic orbits can be extracted and that these orbits can be responsible for nearly periodic behavior lasting a substantial fraction of the observing run.

Boyd, Patricia T.↗

Investigation of loss processes of Tm and Tm,Ho in YAG

The loss of excitation from various manifolds of Tm and Tm,Ho in YAG as a function of temperature and concentration is studied. Two probable loss mechanisms - a Tm up-conversion and a Ho up-conversion - are identified. A 785-nm CW diode laser with 400-nW peak power was focused to a small spot on the sample. The emission from the sample observed at 90 deg was monitored through a monochromator with slits open to 3 mm. Intensity of emission was measured by varying the power of the excitation source using a set of neutral density filters. Power is reported as the percentage of the peak power, and the intensity curves were normalized below 20 percent of transmission. The fact that there is emission above the pump energy indicates an up-conversion from excited manifolds. Nonlinear changes in the intensity of the emission from the Tm 3F4 manifold with the pump power reveals a loss of excitation from this manifold. The linear dependence of the 5I7 manifold emission with pump power at low Tm and high Ho concentrations and the gain of energy in the 5I6 manifold of Ho indicate that the 5I7 manifold loss is due to the coupling of Tm and Ho ions.

Armagan, G.↗

The Space Shuttle, fluid dynamics, and computer graphics

Several samples are presented of CFD-generated flow ribbon images of fuel flow in the SSME. The images result from simulations of H2 flow through a design iteration of the main injector, the hot gas manifold and the fuel bowl section. The color-coded ribbons provide three-dimensional perspectives which indicate the direction and orientation of the flow and the velocity magnitude in intervals along the flow path.

Belie, R. G.↗

Air-Broadened Line Shapes in the 2n3 R Branch of 12ch4 Between 6014 and 6100 cm-1

Complete and accurate information on line shape parameters of 2?3 methane transitions for air broadening as a function of temperature is critical not only for the correct interpretation of the observed atmospheric spectra but also for the development of a reliable theoretical model. For this reason, we obtained a series of high-resolution, high S/N spectra of high-purity 12CH4 and 12CH4 broadened with dry air at temperatures in the 130 to 295 K range using the Bruker IFS 125HR Fourier transform spectrometer at JPL. Two absorption cells were used in the experiment, a White cell with path length of 13 m for room temperature spectra and a 21 m Herriott cella for cold sample spectra. The 15 spectra used in the analysis consisted of 3 low pressure (0.26 to 2.57 Torr) spectra with pure 12CH4 and 12 air-broadened spectra with total sample pressures of 79-805 Torr and volume mixing ratios of methane between 0.23 and 1%. A multispectrum least-squares fitting techniqueb was employed to fit all 15 spectra simultaneously. Preliminary results for select R(J) manifolds will be presented.

V Malathy Devi↗