Engineering PapersSearch

SEARCH · Engineering Papers

Results for “hydrogen systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Nondestructive Evaluation of the Gimbal Joint Flowliner Slots in the Space Shuttle Main Propulsion System Hydrogen Feedline

Fatigue cracks were discovered in the STS-112 Liquid Hydrogen Feedline flowliners in 2002. This led to a development program aimed at providing nondestructive evaluation methods and techniques to verify the existence of these types of cracks in oval shaped slots cut into the ends of the feedlines above the bellows joints. These slots were used to improve flow dynamics and to facilitate cleaning in the bellow joint region. These types of fatigue cracks posed a possible metal debris ingestion threat for the Space Shuttle Main Engines, which attached to these particular joints. Results of this program produced three reliable inspection techniques utilizing the imaging of replisets with a Scanning Electron microscope, eddy current, and ultrasound. The program developed unique probes and fixtures and in the case of eddy current and ultrasound, provided qualification and certification of the particular techniques by various Design of Experiments and Probability of Detection studies utilizing multiple inspectors.

Suits, Michael W.

Scattering of Low Energy Electrons and Positrons from Hydrogenic Systems and Applications

While the electron scatters from the target, the target no longer stays in its original form. One of the first methods to take into account the distortion of the target at low incident energies is the method of polarized orbitals. In this method the wave function for the process is written using the first-order perturbation theory and the equation for the scattering function is derived from the Schradinger equation. This method has been very successful in calculating the phase shifts and therefore the cross sections at various energies. The total wave function can be used to calculate photoionization cross sections. The disadvantage of this approach is that the method is not variational and therefore does not provide bounds on the phase shifts. These difficulties can be overcome by using the Feshbach projection operator formalism. This approach has been employed for the scattering of electrons and positrons from targets. Results of various calculations will be discussed.

Bhatia, Anand K.

Project plan hydrogen energy systems technology. Phase 1: Hydrogen energy systems technology study

An overview of the potential need for hydrogen as a source of energy in the future was presented in order to identify and define the technology requirements for the most promising approaches to meet that need. The following study objectives were discussed: (1) determination of the future demand for hydrogen, based on current trends and anticipated new uses, (2) identification of the critical research and technology advances required to meet this need considering, to the extent possible, raw material limitations, economics, and environmental effects, and (3) definition and recommendation of the scope and space of a National Hydrogen Energy Systems Technology Program and outline of a Program Development Plan.

Source record

NASA Lewis 8- by 6-foot supersonic wind tunnel user manual

The 8- by 6-Foot Supersonic Wind Tunnel (SWT) at Lewis Research Center is available for use by qualified researchers. This manual contains tunnel performance maps which show the range of total temperature, total pressure, static pressure, dynamic pressure, altitude, Reynolds number, and mass flow as a function of test section Mach number. These maps are applicable for both the aerodynamic and propulsion cycle. The 8- by 6-Foot Supersonic Wind Tunnel is an atmospheric facility with a test section Mach number range from 0.36 to 2.0. General support systems (air systems, hydraulic system, hydrogen system, infrared system, laser system, laser sheet system, and schlieren system are also described as are instrumentation and data processing and acquisition systems. Pretest meeting formats are outlined. Tunnel user responsibility and personal safety requirements are also stated.

Soeder, Ronald H.

NASA Lewis 9- by 15-foot low-speed wind tunnel user manual

This manual describes the 9- by 15-Foot Low-Speed Wind Tunnel at the Lewis Research Center and provides information for users who wish to conduct experiments in this atmospheric facility. Tunnel variables such as pressures, temperatures, available tests section area, and Mach number ranges (0.05 to 0.20) are discussed. In addition, general support systems such as air systems, hydraulic system, hydrogen system, laser system, flow visualization system, and model support systems are described. Instrumentation and data processing and acquisition systems are also discussed.

Soeder, Ronald H.

User manual for NASA Lewis 10 by 10 foot supersonic wind tunnel

This manual describes the 10- by 10-Foot Supersonic Wind Tunnel at the NASA Lewis Research Center and provides information for users who wish to conduct experiments in this facility. Tunnel performance operating envelopes of altitude, dynamic pressure, Reynolds number, total pressure, and total temperature as a function of test section Mach number are presented. Operating envelopes are shown for both the aerodynamic (closed) cycle and the propulsion (open) cycle. The tunnel test section Mach number range is 2.0 to 3.5. General support systems, such as air systems, hydraulic system, hydrogen system, fuel system, and Schlieren system, are described. Instrumentation and data processing and acquisition systems are also described. Pretest meeting formats and schedules are outlined. Tunnel user responsibility and personnel safety are also discussed.

Soeder, Ronald H.

Use of Hydrogen Peroxide to Disinfect Hydroponic Plant Growth Systems

Hydrogen peroxide was studied as an alternative to conventional bleach and rinsing methods to disinfect hydroponic plant growth systems. A concentration of 0.5% hydrogen peroxide was found to be effective. Residual hydrogen peroxide can be removed from the system by repeated rinsing or by flowing the solution through a platinum on aluminum catalyst. Microbial populations were reduced to near zero immediately after treatment but returned to pre-disinfection levels 2 days after treatment. Treating nutrient solution with hydrogen peroxide and planting directly into trays being watered with the nutrient solution without replenishment, was found to be detrimental to lettuce germination and growth.

Barta, Daniel J.

Video System Highlights Hydrogen Fires

Video system combines images from visible spectrum and from three bands in infrared spectrum to produce color-coded display in which hydrogen fires distinguished from other sources of heat. Includes linear array of 64 discrete lead selenide mid-infrared detectors operating at room temperature. Images overlaid on black and white image of same scene from standard commercial video camera. In final image, hydrogen fires appear red; carbon-based fires, blue; and other hot objects, mainly green and combinations of green and red. Where no thermal source present, image remains in black and white. System enables high degree of discrimination between hydrogen flames and other thermal emitters.

Youngquist, Robert C.

Lunar Regolith Simulant Feed System for a Hydrogen Reduction Reactor System

One of the goals of In-Situ Resource Utilization (ISRU) on the moon is to produce oxygen from the lunar regolith which is present in the form of Ilmenite (FeTi03) and other compounds. A reliable and attainable method of extracting some of the oxygen from the lunar regolith is to use the hydrogen reduction process in a hot reactor to create water vapor which is then condensed and electrolyzed to obtain oxygen for use as a consumable. One challenge for a production system is to reliably acquire the regolith with an excavator hauler mobility platform and then introduce it into the reactor inlet tube which is raised from the surface and above the reactor itself. After the reaction, the hot regolith (-1000 C) must be expelled from the reactor for disposal by the excavator hauler mobility system. In addition, the reactor regolith inlet and outlet tubes must be sealed by valves during the reaction in order to allow collection of the water vapor by the chemical processing sub-system. These valves must be able to handle abrasive regolith passing through them as well as the heat conduction from the hot reactor. In 2008, NASA has designed and field tested a hydrogen reduction system called ROxygen in order to demonstrate the feasibility of extracting oxygen from lunar regolith. The field test was performed with volcanic ash known as Tephra on Mauna Kea volcano on the Big Island of Hawai'i. The tephra has similar properties to lunar regolith, so that it is regarded as a good simulant for the hydrogen reduction process. This paper will discuss the design, fabrication, operation, test results and lessons learned with the ROxygen regolith feed system as tested on Mauna Kea in November 2008.

Mueller, R. P.

Nickel-hydrogen bipolar battery systems

Nickel-hydrogen cells are currently being manufactured on a semi-experimental basis. Rechargeable nickel-hydrogen systems are described that more closely resemble a fuel cell system than a traditional nickel-cadmium battery pack. This has been stimulated by the currently emerging requirements related to large manned and unmanned low earth orbit applications. The resultant nickel-hydrogen battery system should have a number of features that would lead to improved reliability, reduced costs as well as superior energy density and cycle lives as compared to battery systems constructed from the current state-of-the-art nickel-hydrogen individual pressure vessel cells.

Thaller, L. H.

LaNi5 Hydrogen-Absorption Cryogenic System

Hydrogen-absorption refrigerating system provides about 650 mW of cooling at 20 to 29 K in continuous, closed-cycle operation. Three thermally cycled absorbers/desorbers act as compressors. System successfully tested below 29 K for over 1,000 h, while separate room-temperature hydride compressor operated continuously for 6,000 h. Due to lack of moving parts, lifetimes of 10 years or more eventually expected.

Jones, J. A.

Flight Operation of a Pump-Fed Liquid-Hydrogen Fuel System

A pump-fed liquid-hydrogen fuel system was developed and flight tested in a B57 bomber. The aircraft was flown to an altitude of 50,000 feet and a Mach number of 0.75 with JP-4 fuel in both engines. One engine was then switched to hydrogen operation for approximately 11 minutes. The liquid-hydrogen pump used for these flights was a five-cylinder positive-displacement type submerged in the bottom of the hydrogen tank. The hydrogen flow regulator was able to maintain a constant engine speed even though pump speed and discharge pressure oscillated.

David B. Fenn