At least 37 records · Page 2

Quantum imaging with positronium-decay-emitted gamma rays

The use of entangled gamma rays from positronium decay for quantum-enhanced imaging of dense materials is demonstrated. Quantum ghost images, where only one of the entangled 511-keV photons interacts with the object, are obtained for tantalum samples of varying density using a 210-ps time-resolution dual detector system and a Na-22 positron source. An analysis comparing both classical and quantum imaging modalities is employed to isolate true 511-keV events from background noise. Image quality is quantitatively assessed using transmission ratios and the Michelson contrast. Quantum-correlated images are found to exhibit superior (up to approximately 1.7x, from 0.49 to 0.83 in the thickest sample measured) contrast compared to classical methods and align well with theoretical expectations. These results suggest that quantum ghost imaging with positronium-based entangled gamma rays could significantly enhance noninvasive imaging of high-density objects, with potential applications in areas such as cargo inspection and security screening.

36 MATERIALS SCIENCE↗

Quantum-enhanced Imaging and Spectroscopy and their Relevance to International Safeguards

As a follow-up to our previous report on quantum sensing for safeguards, here we delve deeper into quantum-enhanced imaging & spectroscopy and address their relevance to international safeguards. Much of the approaches rely on entangled photons, a quantum phenomenon not possible with classical physics, although just correlated photons will work for some applications, such as ghost imaging. We provide a comprehensive survey of quantum approaches, including multiple entangled photon ghost imaging and spectroscopy techniques. Entangled photons for noise reduction are also described, as well as Non-Line-Of-Sight imaging, compressive techniques, and squeezed light. Of particular interest is the generation of entangled photons with large wavelength separation, such as infrared/visible entangled photon pairs. Such entangled pairs would allow interaction with objects in the IR, such as in the molecular “fingerprint” wavelength region, while the recording device captures the visible photons, thus leveraging the high efficiency and lower cost of visible detectors. Unfortunately, entangled x-ray photons are not practical, which would have been useful for safeguards to interrogate shielded materials. Entangled gamma rays are even further beyond reason. We provide our assessment for application of quantum-enhanced imaging & spectroscopy for international safeguards, including suggested improvements to existing IAEA instruments and destructive assay measurements that are done at IAEA lab facilities.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Two-dimensional correlation analysis for x-ray photoelectron spectroscopy

Abstract X-ray photoelectron spectroscopy (XPS) measures the binding energy of core-level electrons, which are well-localised to specific atomic sites in a molecular system, providing valuable information on the local chemical environment. The technique relies on measuring the photoelectron spectrum upon x-ray photoionisation, and the resolution is often limited by the bandwidth of the ionising x-ray pulse. This is particularly problematic for time-resolved XPS, where the desired time resolution enforces a fundamental lower limit on the bandwidth of the x-ray source. In this work, we report a novel correlation analysis which exploits the correlation between the x-ray and photoelectron spectra to improve the resolution of XPS measurements. We show that with this correlation-based spectral-domain ghost imaging method we can achieve sub-bandwidth resolution in XPS measurements. This analysis method enables XPS for sources with large bandwidth or spectral jitter, previously considered unfeasible for XPS measurements.

47 OTHER INSTRUMENTATION↗

The Role of Quantum Science Concepts in Enhancing Sensing and Imaging Technologies: Applications for Biology: Proceedings of a Workshop

Quantum concepts hold the potential to enable significant advances in sensing and imaging technologies that could be vital to the study of biological systems. The workshop Quantum Science Concepts in Enhancing Sensing and Imaging Technologies: Applications for Biology, held online March 8–10, 2021, was organized to examine the research and development needs to advance biological applications of quantum technology. Hosted by the National Academies of Sciences, Engineering, and Medicine, the event brought together experts working on state-of-the-art, quantum-enabled technologies and scientists who are interested in applying these technologies to biological systems. Through talks, panels, and discussions, the workshop facilitated a better understanding of the current and future biological applications of quantum-enabled technologies in fields such as microbiology, molecular biology, cell biology, plant science, mycology, and many others. The workshop was organized around three main themes. The first, quantum in biology, examined quantum concepts that are hypothesized to be important for life processes and that researchers are working to observe through biological imaging and sensing. The second, quantum for biology, addressed ways to use quantum concepts to enhance technologies for biological imaging and sensing. The third, biology for quantum, offered a wider discussion of how the frontiers of biological imaging and sensing could enable future study using quantum concepts, tools, or technologies. Throughout the workshop, participants identified a wide range of emerging approaches and opportunities at the intersection of quantum physics and biological sensing and imaging. During the workshop, there were some differences in how each speaker defined the term quantum. During one of the panels, Prem Kumar offered thoughts on what phenomena are classical versus quantum, explaining that techniques get progressively more quantum as you move from just having superposition to having superposition with measurement and entanglement. Another explanation from Clarice Aiello delineates the definition into several levels. This includes a base level of “quantum-ness,” which reflects that all matter is made of atoms, and when these particles are isolated they behave based on quantum mechanical principles. A second level is related to quantum coherence, where a single quantum object might be found in a coherent superposition state. A final level, which she described as the quantum-entangled level, involves multiple quantum systems which are entangled among themselves. Overall, the workshop touched on concepts such as superposition, entanglement, and squeezing and their potential implications for communication, computing, and simulation, in addition to the workshop’s main focal area, biological sensing and imaging. At the opening of the workshop, Thorsten Ritz of the University of California, Irvine, identified two questions at the heart of quantum biology: Is the machinery of life quantum mechanical, and can quantum mechanics be used to study the machinery of life in new ways? Participants highlighted systems in which researchers have explored these questions, from the vast array of molecular interactions involved in biological processes such as photosynthesis, to the mechanics involved in cellular functions such as differentiation and aggregation, to the role of oscillating magnetic fields in flight orientation among birds. Sensing and imaging technologies are crucial to biological research; these technologies could both enhance the study of quantum effects and be enhanced by quantum concepts. A critical challenge in biological research is to develop imaging and sensing tools that do not damage or interfere with the often fragile and fleeting systems being studied. Attendees discussed a variety of established and emerging technologies that could enhance noninvasive biological imaging, including single- and two-photon spectroscopy, single-molecule spectroscopy, quantum illumination, ghost imaging, and cryo-electron microscopy. One example came from Marlan Scully who gave a keynote address on the first day of the workshop. Scully emphasized the use of different laser technologies, which exhibit coherence and other quantum properties, in moving toward real-world biological applications, such as the detection of SARS-CoV-2. Both tools and theory will play an important role in advancing quantum biology research and applications. Several participants suggested theorists and experimentalists should work in tandem to understand and model biological processes. While physics often reduces systems to their simplest forms for fundamental insights, participants also noted the value of observing and understanding biological systems in all their “messiness,” capturing both the inner workings of biological systems and the complex interactions that occur within and between organisms. In discussions among participants, several attendees stressed the need to match emerging tools with the right scientific questions. Rather than developing quantum technologies as “a hammer looking for a nail,” participants emphasized a focus on exploring the problems these technologies are best suited to address. For example, it is important to consider the size of the phenomenon being studied, the timescales that are important in answering the scientific question, and other relevant considerations. Every tool along the spectrum from classical to quantum involves its own set of trade-offs. For example, Ted Laurence of the Lawrence Livermore National Laboratory said that quantum measurements, such as single photon counting, fluorescence transitions, and lasers, can take longer to produce the same results as classical measurements. These quantum measurements, however, do not require calibration and can enable new research questions to be answered. Prem Kumar, Northwestern University, noted that, despite their promise, quantum approaches should not be used simply for the sake of using quantum, especially in situations where classical approaches better meet the needs of the researcher. Understanding and applying quantum concepts could enable advances in a wide range of application areas including energy, synthetic biology, medicine, and sustainability. For example, Michelle O’Malley, University of California, Santa Barbara, described how improved noninvasive imaging approaches could help capture the complex interactions and functions involved in the breakdown of organic matter by microbial communities and lead to new technologies for capturing valuable products from plant waste. Several other participants discussed needs in tracking the movement of metabolites and molecules in microbial communities for insights into nutrient cycling in environments such as soil. Margaret Ahmad, Sorbonne University, discussed potential opportunities to leverage the magnetic properties of cryptochromes to advance new treatment approaches for diseases such as COVID-19 and cancer. Looking toward the future development of the field, participants discussed challenges to advancing quantum biology that arise from disciplinary disconnects between physicists and biologists. The siloing of academic research disciplines represents a significant barrier to progress. Disconnects in terminology, motivations and priorities, and structural barriers to collaborative work underscore the need for concerted efforts to bridge these divides. Attendees and speakers offered suggestions for resolving these divergences, establishing a shared language, moving the field forward, and fostering meaningful feedback between disciplines. Overall, participants stressed a need for balance, open communication, collaboration, unity, and clear dialogue on trade-offs between quantum and classical approaches. Keiko Torii, The University of Texas at Austin, said that the best collaborations happen when the project provides mutual advantages that can show off everyone’s talents, each team finds the work interesting, and partners develop a camaraderie to pursue new knowledge. To enable near- and long-term opportunities in this space, participants suggested that exploratory, high-risk funding could improve existing instrumentation to explore quantum enhancement collaboratively. They also emphasized the need for collaboration between quantum physicists and sensing/imaging scientists, which could be advanced through a dedicated quantum biology investigator program. People, even more than technology, will be crucial to the future of quantum biology. Participants explored training, education, and workforce needs to further develop this burgeoning field and cultivate the next generation of scientists. While many programs are still in their nascent stages, participants highlighted examples of approaches and programs being developed at various types of institutions to engage students and professional scientists in quantum biology research. Several participants stressed the need for an inclusive approach, spanning disciplines as well as communities to foster a diverse field fueled by the intellectual contributions of a wide range of people, including historically under-resourced schools and students. To increase awareness and excitement about quantum physics and related areas of biology, attendees suggested capitalizing on the “buzz” around quantum. Several participants emphasized the need to start early, introducing students to quantum concepts and their appealing “weirdness” in K–12 education. Engaging students early—before they become entrenched in traditional disciplinary siloes as typically happens in graduate school—could help to galvanize interest in the area and foster a generation of scientists with the interdisciplinary mindset and skills needed to advance this interdisciplinary field. While these efforts could be advanced at many levels and across multiple sectors, several participants suggested a national quantum biology center could be a valuable hub to coordinate and support quantum biology education and workforce development across academia, industry, and government.

59 BASIC BIOLOGICAL SCIENCES↗

Photofield electron emission from an optical fiber nanotip

In this work, we demonstrate a nanotip electron source based on a graded index multimode silica optical fiber, tapered at one end to a radius of curvature r ~50 nm and coated with a thin film of gold. We report observation of laser-induced electron photoemission at tip bias potentials below the onset of dark field emission. Single-photon photofield emission is identified as the emission mechanism that exhibits fast switching times with an upper limit on the order of 1 μ s. The explored fiber optic nanotips are flexible back-illuminated emitters, which can be operated in continuous wave and pulsed modes using lasers with photon energies in the visible range or higher. The mechanical flexibility of the source can facilitate externally controlled positioning. Multiple, individually addressable, nanotips may be assembled into a bundle for applications such as computational electron ghost imaging.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Two-photon X-ray ghost microscope

This article presents a non-classical imaging mechanism that produces a diffraction-limited and magnified ghost image of the internal structure of an object through the measurement of intensity fluctuation correlation formed by two-photon interference. In principle, the lensless X-ray ghost imaging mechanism may achieve a spatial resolution determined by the wavelength and the angular diameter of the X-ray source, ∼ λ /Δ θ s , with possible reduction caused by additional optics. In addition, it has the ability to image select “slices” deep within an object, which can be used for constructing 3D view of its internal structure.

Smith, Thomas A. (ORCID:0000000275427047)↗

In Situ Measurements of the Reflectances of the LSSTCam Optics and Assessing the Impact of Optical Ghosts

Optical ghosts are image artifacts caused by successive reflections of light between optical surfaces such as lenses, filters, and detectors. These artifacts are unavoidable due to the nonzero reflectances of optical elements and are a major source of contamination for low-surface-brightness science. We use optical ray tracing simulations tuned to observations from LSST Commissioning to quantify the impact of optical ghosts on the LSST data. In particular, we find that ~0.57% of the LSSTCam focal plane is impacted by optical ghosts when averaged across all bands. We also use data from the Collimated Beam Projector to measure the reflectances of various optical elements, generally confirming estimates of ~2% from the systems engineering throughput predictions.

Pai, Aashay↗

Advancing X-ray quantum imaging through Monte-Carlo simulations

Imaging with X-rays poses fundamental limits due to radiation damage of the highly energetic photons. This becomes problematic for sensitive biological systems such as subcellular structures. Lowering the radiation dose, without sacrificing the signal-to-noise ratio, would be desirable for any kind of imaging modalities involving X-rays. To achieve this goal, quantum imaging with entangled X-ray photons constitutes a promising route. Production of biphotons have been demonstrated in the X-ray regime by the process of Spontaneous Parametric Down-Conversion (SPDC). However, compared to SPDC in the regime of visible light, the production rate for X-ray biphotons is extremely low. With the introduction of new high average brightness X-ray sources, such as 4th generation synchrotrons and high repetition rate Free-Electron X-ray Lasers (XFEL), quantum imaging may become practical. We introduce a ray tracing approach using Monte-Carlo sampling, specifically designed for quantum imaging with entangled X-ray photons generated by SPDC. By simulation, the superior image quality of quantum over classical imaging methods is demonstrated using realistic experimental conditions available at high repetition rate XFELs. With these simulations, we can efficiently assist the design of future experiments at beam lines, which can substantially accelerate the advancement of X-ray quantum imaging and reduce costs.

Entangled Photons↗

A review of quantum imaging methods and enabling technologies

The field of quantum imaging has recently seen an explosion of new methods and techniques. At the heart of most quantum imaging approaches are three enabling technologies: the source of the quantum light, the detectors that turn sensing into imaging, and the method by which the quantum nature of light is leveraged to improve the desired measurement. This review addresses the dominant and emerging technologies in each of these components as well as details concerning the implementations of various quantum imaging methods.

36 MATERIALS SCIENCE↗

Using Mask R-CNN to detect and mask ghosting and scattered-light artifacts in astronomical images

Wide-field astronomical surveys are often affected by the presence of undesirable reflections (often known as “ghosting artifacts” or “ghosts”) and scattered-light artifacts. The identification and mitigation of these artifacts is important for rigorous astronomical analyses of faint and low-surface-brightness systems. In this work, we use images from the Dark Energy Survey (DES) to train, validate, and test a deep neural network (Mask R-CNN) to detect and localize ghosts and scattered- light artifacts. We find that the ability of the Mask R-CNN model to identify affected regions is superior to that of conventional algorithms that model the physical processes that lead to such artifacts, thus providing a powerful technique for the automated detection of ghosting and scattered-light artifacts in current and near-future surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

DeepGhostBusters: Using Mask R-CNN to Detect and Mask Ghosting and Scattered-Light Artifacts from Optical Survey Images

Wide-field astronomical surveys are often affected by the presence of undesirable reflections (often known as "ghosting artifacts" or "ghosts") and scattered-light artifacts. The identification and mitigation of these artifacts is important for rigorous astronomical analyses of faint and low-surface-brightness systems. However, the identification of ghosts and scattered-light artifacts is challenging due to a) the complex morphology of these features and b) the large data volume of current and near-future surveys. In this work, we use images from the Dark Energy Survey (DES) to train, validate, and test a deep neural network (Mask R-CNN) to detect and localize ghosts and scattered-light artifacts. We find that the ability of the Mask R-CNN model to identify affected regions is superior to that of conventional algorithms and traditional convolutional neural networks methods. We propose that a multi-step pipeline combining Mask R-CNN segmentation with a classical CNN classifier provides a powerful technique for the automated detection of ghosting and scattered-light artifacts in current and near-future surveys.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Collimated phase measuring deflectometry II: Re-design of the optical layout for high-curvature surfaces

Collimated phase measuring deflectometry (CPMD) is an optical metrology technique developed to improve upon traditional phase measuring deflectometry (PMD). CPMD utilizes telecentric imaging and collimated structured light illumination to eliminate the height-slope ambiguity present in traditional PMD measurements. After the publication of the first CPMD paper, efforts began to optimize the optical layout of the CPMD system. The first proposed change, and the one detailed in this work, was to move the Fourier transform (FT) lens closer to the surface under test (SUT). Moving the FT lens closer to the SUT meant that for a given FT lens diameter, a larger range of surface slopes on the SUT could be measured. This change to the optical layout was not trivial and introduced at least two concerns that had to be addressed: telecentricity in the imaging path and possible ghost reflections from the re-located FT lens. Here, in this work, we examine how these concerns were addressed and present results showing that the revised optical layout is capable of measurement results at least as good as the original CPMD optical layout. We also demonstrate the increased slope measuring range of the revised optical layout.

47 OTHER INSTRUMENTATION↗

Raytracing the long trace profiler

The optical design of the Long Trace Profiler optical system is explored with a commercial raytrace program, Zemax OpticStudio™ (ZOS)1, with the intent of finding and correcting sources of systematic error. ZOS provides both geometric raytracing tools and physical optics Gaussian beam propagation and diffraction image calculation tools, and two design modes, sequential component (SC) and non-sequential component (NSC) that are optimized for different aspects of the design process. The original LTP-II system employs a singlet lens with a 1250 mm focal length. It is optimized to provide minimum distortion over a surface slope angle range of ±5 mrad. Using the ZOS tools, we are able to simulate ghost rays that produce distortion in the beam spot image and can minimize the distortion by deliberate misalignment of the beamsplitter (BS) components. Unfortunately, the reference beam is compromised because of the component tilts. The most recent LTP500 system design simplifies the optical system and makes the reference beam usable again, even with misalignment of the polarizing beamsplitter (PBS). Two lenses are designed for the LTP500 - a cemented doublet that has been fabricated, and a singlet with one aspheric surface. Both have focal distances of 500 mm with an expanded angular measurement range of ±10 mrad. The aspheric singlet provides superior performance. ZOS allows the import of wavefront measurement data produced by commercial interferometer software. We apply the wavefront error measurement from the cemented doublet to the model to show that the 19nm RMS wavefront error needs to be improved by at least a factor of ten in order to reduce the systematic error to a level that will allow the LTP to approach its design limit of a few tens of nanoradians.

Takacs, Peter Z.↗

Chasing ghosts: characterization of artifact generation in coded aperture decoding due to experimental implementation

Coded aperture imaging is a form of lensless aperture imaging that projects multiple overlapping images of the source onto the detector, enhancing signal strength, which is advantageous for low-flux sources or high-resolution imaging. This technique requires decoding of the detector signal to reconstruct the original source, which involves convolving the detector data with the aperture pattern. When the signal is from a centered point source, the reconstructed source image is known as the point spread function (PSF). A clean PSF without artifacts is a Dirac delta function [Appl. Opt. 20, 1858 (1981)]. This paper examines the robustness of the decoding process against variations in experimental tolerances by analyzing artifact growth in the reconstructed PSF. We illustrate the effects of incorrect magnification, rotation, and detector size and find that aperture–detector rotational misalignment about the imaging axis is the most sensitive parameter, with significant artifact generation occurring with angular offsets of less than one degree. We discuss compensation methods for imperfect aperture placement, finding that small detector sizes produce uncompensatable artifact generation, and compare theoretical predictions with experimental PSF measurements of a rank , 6.8 mm thick (less than one mean free path) coded aperture with a 3.5 mm cell size, conducted at the MegaJOuLe Neutron Imaging Radiography dense plasma focus [IEEE Trans. Plasma Sci. 49, 3299 (2021)] using a 2.45 MeV neutron source. Based on our findings, we recommend using magnified coded apertures in the under-sampled regime, which allows for the inclusion of fiducial markers to characterize aperture–detector rotational offsets and the addition of mechanical coupling, where possible, to constrain rotational and magnification offsets.

Selwood, M. P. [Lawrence Livermore National Labora↗

Metal Halide Scintillators with Fast and Self‐Absorption‐Free Defect‐Bound Excitonic Radioluminescence for Dynamic X‐Ray Imaging

Abstract Scintillators for radiation detection are of great significance in medical imaging, security, and nondestructive inspection. The current challenge for scintillators is to simultaneously achieve high scintillation light yield, fast radioluminescence, simple film fabrication, large X‐ray attenuation efficiency as well as stable and nontoxic compositions; no previous scintillators fulfill all the above requirements. Here, metal halide Rb 2 AgBr 3 , possessing defect‐bound excitonic radioluminescence, is shown as efficient and fast scintillators. This nontoxic and stable scintillator emits from excitons bound to neutral bromine vacancies, enjoying an efficient and spin‐allowed fast emission with minimized self‐absorption. Rb 2 AgBr 3 thus has a high light yield (25 600 photons MeV −1 ), fast scintillation decay time (5.31 ns), and a record value of light yield versus decay time (4821 photons MeV −1 ns −1 ). The close‐space sublimation method is developed for fast and scalable fabrication of oriented Rb 2 AgBr 3 films. The scintillator film is further integrated with commercial flat‐panel imagers, and the spatial resolution reaches 10.2 line pairs per millimeter at the modulation transfer function of 0.2, doubling the resolution of conventional CsI:Tl flat‐panel detectors. The dynamic X‐ray imaging and its use to real‐time monitoring of bone movement without ghosting effect is also demonstrated.

Zhang, Muyi↗

Evaluating Machine Learning-Based MRI Reconstruction Using Digital Image Quality Phantoms

Quantitative and objective evaluation tools are essential for assessing the performance of machine learning (ML)-based magnetic resonance imaging (MRI) reconstruction methods. However, the commonly used fidelity metrics, such as mean squared error (MSE), structural similarity (SSIM), and peak signal-to-noise ratio (PSNR), often fail to capture fundamental and clinically relevant MR image quality aspects. To address this, we propose evaluation of ML-based MRI reconstruction using digital image quality phantoms and automated evaluation methods. Our phantoms are based upon the American College of Radiology (ACR) large physical phantom but created in k-space to simulate their MR images, and they can vary in object size, signal-to-noise ratio, resolution, and image contrast. Our evaluation pipeline incorporates evaluation metrics of geometric accuracy, intensity uniformity, percentage ghosting, sharpness, signal-to-noise ratio, resolution, and low-contrast detectability. We demonstrate the utility of our proposed pipeline by assessing an example ML-based reconstruction model across various training and testing scenarios. The performance results indicate that training data acquired with a lower undersampling factor and coils of larger anatomical coverage yield a better performing model. The comprehensive and standardized pipeline introduced in this study can help to facilitate a better understanding of the performance and guide future development and advancement of ML-based reconstruction algorithms.

47 OTHER INSTRUMENTATION↗