Engineering Papers⌕ Search

DOE OSTI · 1835455

Two-dimensional correlation analysis for x-ray photoelectron spectroscopy

Abstract

Abstract X-ray photoelectron spectroscopy (XPS) measures the binding energy of core-level electrons, which are well-localised to specific atomic sites in a molecular system, providing valuable information on the local chemical environment. The technique relies on measuring the photoelectron spectrum upon x-ray photoionisation, and the resolution is often limited by the bandwidth of the ionising x-ray pulse. This is particularly problematic for time-resolved XPS, where the desired time resolution enforces a fundamental lower limit on the bandwidth of the x-ray source. In this work, we report a novel correlation analysis which exploits the correlation between the x-ray and photoelectron spectra to improve the resolution of XPS measurements. We show that with this correlation-based spectral-domain ghost imaging method we can achieve sub-bandwidth resolution in XPS measurements. This analysis method enables XPS for sources with large bandwidth or spectral jitter, previously considered unfeasible for XPS measurements.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Li, S. (ORCID:0000000212626292), Driver, T. (ORCID:0000000237616883), Al Haddad, A., Champenois, E. G., Agåker, M., Alexander, O., Barillot, T., Bostedt, C., Garratt, D., Kjellsson, L. (ORCID:0000000195453579), Lutman, A. A., Rubensson, J-E, Sathe, C., Marinelli, A., Marangos, J. P., Cryan, J. P. (ORCID:0000000277760919). 2021-08-12. Two-dimensional correlation analysis for x-ray photoelectron spectroscopy. https://doi.org/10.1088/1361-6455%2Fabcdf1

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

High Multiplicity Trigger for long-lived particles in CMS detector

Searches for long-lived particles (LLPs) at the CMS experiment often involve unconventional event topologies that are difficult to efficiently select using standard trigger strategies. To improve sensitivity to such signatures during LHC Run 3 operation, a dedicated High Multiplicity Trigger (HMT) has been developed and deployed in the CMS trigger system. The trigger targets events containing unusually large numbers of hits in the CMS cathode strip chamber (CSC) muon detectors, a characteristic signature of several LLP scenarios involving displaced decays in the muon system. The HMT implementation, trigger logic, rate dependence with pileup, and operational stability are described. Optimized hit multiplicity thresholds are used to maintain acceptable trigger rates under high-luminosity and high-pileup conditions while preserving high efficiency across a broad range of LLP lifetimes and kinematic regimes. The trigger performance is evaluated using both simulated event samples and proton-proton collision data collected during Run 3 of the LHC. The HMT substantially extends the CMS sensitivity to non-standard signatures associated with LLP decays and provides a flexible platform for future searches for physics beyond the Standard Model.

47 OTHER INSTRUMENTATION↗