Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “focal”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A refined methodology for stress inversions of earthquake focal mechanisms: Refined Stress Inversion Methodology

We develop an improved methodology for reliable high-resolution inversions of focal mechanisms to background stress field orientation and stress ratio R in two or three dimensions. The earthquake catalog is declustered to remove events likely affected strongly by local stress interactions rather than reflecting the large-scale background stress field. The declustered data are discretized with the k-means algorithm into groups containing a number of focal mechanisms between a minimum number N min and 2N min . Synthetic tests indicate that N min ≈ 30 provides stable inversion results under different stress regimes and noise conditions when R ≈ 0.5, while N min ≈ 45 is needed for R near 0 or 1. Additional synthetic tests compare the performance of selecting the fault plane of each focal mechanism using (a) the plane with lowest misfit angle between the slip vector from the focal mechanism and shear traction from the stress tensor and (b) the plane with highest instability coefficient representing proximity to the optimally oriented fault for given stress field and friction coefficient. The instability criterion is found to provide more accurate inversion results under all tested stress regimes, stress ratios, and noise conditions. The refined inversion methodology combines selecting fault planes using the instability criterion iteratively with a damped simultaneous inversion of different focal mechanism groups. Results characterizing neighborhoods of discretized domains merged during the damped inversion provide high-resolution information independent of the discretization. Some aspects of the methodology are illustrated with focal mechanism data from the San Jacinto Fault Zone in Southern California.

58 GEOSCIENCES↗

In vivo epidermal migration requires focal adhesion targeting of ACF7

Turnover of focal adhesions allows cell retraction, which is essential for cell migration. The mammalian spectraplakin protein, ACF7 (Actin-Crosslinking Factor 7), promotes focal adhesion dynamics by targeting of microtubule plus ends towards focal adhesions. However, it remains unclear how the activity of ACF7 is regulated spatiotemporally to achieve focal adhesion-specific guidance of microtubule. To explore the potential mechanisms, we resolve the crystal structure of ACF7's NT (amino-terminal) domain, which mediates F-actin interactions. Structural analysis leads to identification of a key tyrosine residue at the calponin homology (CH) domain of ACF7, whose phosphorylation by Src/FAK (focal adhesion kinase) complex is essential for F-actin binding of ACF7. Using skin epidermis as a model system, we further demonstrate that the phosphorylation of ACF7 plays an indispensable role in focal adhesion dynamics and epidermal migration in vitro and in vivo . Altogether, our findings provide critical insights into the molecular mechanisms underlying coordinated cytoskeletal dynamics during cell movement.

59 BASIC BIOLOGICAL SCIENCES↗

WE-EF-BRA-07: High Performance Preclinical Irradiation Through Optimized Dual Focal Spot Dose Painting and Online Virtual Isocenter Radiation Field Targeting

Purpose: Advances in radiotherapy practice facilitated by collimation systems to shape radiation fields and image guidance to target these conformal beams have motivated proposals for more complex dose patterns to improve the therapeutic ratio. Recent progress in small animal radiotherapy platforms has provided the foundation to validate the efficacy of such interventions, but robustly delivering heterogeneous dose distributions at the scale and accuracy demanded by preclinical studies remains challenging. This work proposes a dual focal spot optimization method to paint spatially heterogeneous dose regions and an online virtual isocenter targeting method to accurately target the dose distributions. Methods: Two-dimensional dose kernels were empirically measured for the 1 mm diameter circular collimator with radiochromic film in a solid water phantom for the small and large x-ray focal spots on the X-RAD 225Cx microirradiator. These kernels were used in an optimization framework which determined a set of animal stage positions, beam-on times, and focal spot settings to optimally deliver a given desired dose distribution. An online method was developed which defined a virtual treatment isocenter based on a single image projection of the collimated radiation field. The method was demonstrated by optimization of a 6 mm circular 2 Gy target adjoining a 4 mm semicircular avoidance region. Results: The dual focal spot technique improved the optimized dose distribution with the proportion of avoidance region receiving more than 0.5 Gy reduced by 40% compared to the large focal spot technique. Targeting tests performed by irradiating ball bearing targets on radiochromic film pieced revealed the online targeting method improved the three-dimensional accuracy from 0.48 mm to 0.15 mm. Conclusion: The dual focal spot optimization and online virtual isocenter targeting framework is a robust option for delivering dose at the preclinical level and provides a new experimental option for unique radiobiological investigations This work is supported, in part, by the Natural Sciences and Engineering Research Council of Canada and a Mitacs-Accelerate fellowship. P.E. Lindsay, and D.A. Jaffray are listed as inventors of the system described herein. This system has been licensed to Precision X-Ray Inc. for commercial development.

60 APPLIED LIFE SCIENCES↗

Focal axis resolver for offset reflector antennas

Method and apparatus for determining the focal axis of an asymmetrical antenna such as an offset paraboloid reflector whose physical rim is not coincident with the boundary of the electrical aperture but whose focal point is known is provided. A transmitting feed horn array consisting of at least two feed horn elements is positioned asymmetrically on either side of an estimated focal axis which is generally inclined with respect to the boresight axis of the antenna. The feed horn array is aligned with the estimated focal axis so that the phase centers (CP sub 1, CP sub 2) of the two feed horn elements are located on a common line running through the focal point (F) orthogonally with respect to the estimated focal axis.

Schmidt, R. F.↗

Diagnostic accuracy of F-18 FDG PET/CT for characterization of colorectal focal FDG uptake: a systematic review and meta-analysis

Introduction: We aimed to explore the role of the diagnostic accuracy of F-18 fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) for characterization of incidental colorectal focal FDG uptake through a systematic review and meta-analysis. Methods: The MEDLINE, EMBASE, and Cochrane Library database, from the earliest available date of indexing through April 30, 2018, were searched for studies evaluating the diagnostic performance of F-18 FDG PET/CT for characterization of incidental colorectal focal FDG uptake. We determined the sensitivities and specificities across studies, calculated positive and negative likelihood ratios (LR+ and LR−), and constructed summary receiver operating characteristic curves. Results: Across 8 studies (1451 patients), the pooled sensitivity for F-18 FDG PET/CT was 0.87 (95% CI 0.82–0.90) without heterogeneity (χ{sup 2} = 10.84, p = 0.37) and a pooled specificity of 0.83 (95% CI 0.76–0.89) with heterogeneity (χ{sup 2} = 130.1, p = 0.00). Likelihood ratio (LR) syntheses gave an overall positive likelihood ratio (LR+) of 5.2 (95% CI 3.6–7.4) and negative likelihood ratio (LR−) of 0.16 (95% CI 0.12–0.22). The pooled DOR was 32 (95% CI 20–51). Conclusion: F-18 FDG PET/CT demonstrated good sensitivity and specificity for characterization of incidental colorectal focal FDG uptake. At present, the literature regarding the use of F-18 FDG PET/CT for characterization of incidental colorectal focal FDG uptake remains still limited; thus, further large multicenter studies would be necessary to substantiate the diagnostic accuracy of F-18 FDG PET/CT for characterization of incidental colorectal focal FDG uptake.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Focal mass-like cardiac uptake on oncologic FDG PET/CT: Real lesion or atypical pattern of physiologic uptake?

Background: Cardiac uptake on oncologic FDG PET/CT can be unpredictable. Focal or mass-like cardiac uptake not confined to normal pattern is a real challenge for interpretation due to great variability in physiologic uptake and rarity of either primary or metastatic cardiac neoplasms. Methods and Results: Eight patients with suspicious mass-like cardiac uptake on oncologic FDG PET/CT were retrospectively analyzed with correlation to cardiac workups including contrast CT, echocardiography, and repeat PET/CT. Four patients had real cardiac lesions or metastases. Focal uptake was benign and might represent papillary muscle in the other four. SUV{sub max} ratio between the cardiac focus and surrounding background cardiac uptake was statistically higher in the true-positive group than that in the false-positive group. In addition, the patients with true-positive cardiac uptake had more diffuse distant metastases compared to those with false-positive cardiac uptake. Conclusions: Focal suspicious cardiac uptake on oncology FDG PET/CT warranted further evaluation. SUV{sub max} ratio between the cardiac focus and surrounding background cardiac uptake and status of distant metastases might help to differentiate malignant from benign nature of the focal cardiac uptake on FDG PET/CT. Focal uptake of the right ventricle on oncologic FDG PET/CT is more likely suggestive of a neoplasm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Approximating large-basis coupled-cluster theory vibrational frequencies using focal-point approximations

The focal-point approximation can be used to estimate a high-accuracy, slow quantum chemistry computation by combining several lower-accuracy, faster computations. We examine the performance of focal-point methods by combining second-order Møller–Plesset perturbation theory (MP2) with coupled-cluster singles, doubles, and perturbative triples [CCSD(T)] for the calculation of harmonic frequencies and that of fundamental frequencies using second-order vibrational perturbation theory (VPT2). In contrast to standard CCSD(T), the focal-point CCSD(T) method approaches the complete basis set (CBS) limit with only triple-ζ basis sets for the coupled-cluster portion of the computation. The predicted harmonic and fundamental frequencies were compared with the experimental values for a set of 20 molecules containing up to six atoms. Here, the focal-point method combining CCSD(T)/aug-cc-pV(T + d)Z with CBS-extrapolated MP2 has mean absolute errors vs experiment of only 7.3 cm −1 for the fundamental frequencies, which are essentially the same as the mean absolute error for CCSD(T) extrapolated to the CBS limit using the aug-cc-pV(Q + d)Z and aug-cc-pV(5 + d)Z basis sets. However, for H 2 O, the focal-point procedure requires only 3% of the computation time as the extrapolated CCSD(T) result, and the cost savings will grow for larger molecules.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-speed Focal Plane Wave Front Sensing with an Optical Chopper

Focal plane wave front sensing and control is a critical approach to reducing noncommon path errors between a conventional astronomical adaptive optics (AO) wave front sensor (WFS) detector and a science camera. However, in addition to mitigating noncommon path errors, recent focal plane wave front sensing techniques have been developed to operate at speeds fast enough to enable "multi-WFS" AO, where residual atmospheric errors are further corrected by a focal plane WFS. Although a number of such techniques have been recently developed for coronagraphic imaging, here we present one designed for noncoronagraphic imaging. Utilizing conventional AO system components, this concept additionally requires (1) a detector imaging the focal plane of the WFS light source and (2) a pupil plane optical chopper device that is the noncommon path to the first WFS and is synchronized to the focal plane imager readout. These minimal hardware requirements enable the temporal amplitude modulation to resolve the sine ambiguity of even wave-front modes for low, mid, and high wave front spatial frequencies. Similar capabilities have been demonstrated with classical phase diversity by defocusing the detector, but such techniques are incompatible with simultaneous science observations. This optical chopping technique, however, enables science imaging at up to 50% duty cycle. In conclusion, we present both simulations and laboratory validation of this concept on SEAL, the Santa Cruz Extreme AO Laboratory testbed.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-G-206-02: Impact of Focal Spot Sizes On CT Image Quality

Purpose: To quantify a radiology team’s assessment of image quality differences between two CT scanner models currently in clinical use, with emphasis on spatial resolution that could be impacted by focal spot size. Methods: Modulation Transfer Functions (MTF) measurements were performed by scanning the impulse source insert module of the Catphan 600 at 120/140 kVp with both large (LFS) and small (SFS) focal spots and reconstructed to 2.5mm and 5.0mm thicknesses on a GE Discovery CT750 HD and a LightSpeed VCT CT scanner. MTFs were calculated by summing the 2D PSF along one-dimension to obtain line-spread-function (LSF), and calculating the Fourier Transform of the zero-padded and background corrected LSF. Spatial resolution performance was evaluated by comparing MTF curves, 50% and 10% MTF cutoff, and total area under the MTF curve (AUC). In addition, images of the Catphan high-contrast module and a Kagaku anthropomorphic body phantom were acquired from the HD scanner for visual comparisons. Results: For each scanner model, SFS was superior to LFS spatial resolution with respect to 50%/10% MTF cutoff and AUC. For the HD, 50%/10% cutoff was 4.29/7.22cm-1 for the LFS and 4.43/7.45cm-1 for the SFS. VCT outperformed HD, with 50%/10% cutoff of 4.40/7.29 cm-1 for LFS and 4.62/7.47cm-1 for SFS. Scanner model performance in order of decreasing AUC performance was VCT SFS (7.43), HD SFS (7.20), VCT LFS (7.09) and HD LFS (6.93). Visual evaluations of Kagaku phantom images confirmed that VCT outperformed HD. Conclusion: VCT outperformed HD and small focal spot is desired for either model over large focal spot in term of spatial resolution – in agreement with radiologist feedback of overall image quality. In-depth evaluations of clinical impact and focal spot selection mechanisms is currently being assessed.

60 APPLIED LIFE SCIENCES↗

Microseismic Focal Mechanisms and Implications for Changes in Stress during the 2014 Newberry EGS Stimulation

We adapt the relative polarity method from Shelly et al. (2016) to compute focal mechanisms for microearthquakes associated with the 2014 hydroshearing stimulation at the Newberry volcano geothermal site. We focus the analysis on events relocated by Aguiar and Myers (2018), who report that six event clusters predominantly comprise the 2014 sequence. Data quality allows focal mechanism analysis for four of the six event clusters. We use Hardebeck and Shearer (2002, 2003; hereafter HASH) to compute focal mechanisms based on first–motion polarities and S/P amplitude ratios. We manually determine P– and S–wave polarities for a well–recorded reference event in each cluster, then use waveform cross correlation to determine whether recordings of other events in the cluster are the same or reversed polarity at each network station. Here, most waveform polarities are consistent with the affiliated reference event, indicating similar focal mechanisms within each cluster. The deeper clusters are east–west–striking normal faults, whereas the shallower clusters, close to the top of the open–hole section of the borehole, are strike slip with east–west motion. Regional studies and prestimulation borehole breakouts find the maximum stress direction is vertical and maximum horizontal stress is approximately north–south. Fault geometry and focal mechanisms of microseismicity during the stimulation suggest that increased pressure from fluid injection predominantly caused changes in horizontal stress, consistent with predictions from numerical studies of stress change caused by fluid injection. At shallow depths, where previous studies suggest the difference between vertical and horizontal stress is lowest, injection appears to have rotated the direction of maximum stress from vertical to horizontal, resulting in strike–slip motion. At greater depth, vertical stress continued to be the dominant direction during the stimulation, but fault orientation indicates either reactivation of pre–existing fractures or rotation of the direction of maximum horizontal stress from approximately north–south to east–west.

15 GEOTHERMAL ENERGY↗

Inferring the Focal Depths of Small Earthquakes in Southern California Using Physics-Based Waveform Features

Determining the depths of small crustal earthquakes is challenging in many regions of the world, because most seismic networks are too sparse to resolve trade-offs between depth and origin time with conventional arrival-time methods. Precise and accurate depth estimation is important, because it can help seismologists discriminate between earthquakes and explosions, which is relevant to monitoring nuclear test ban treaties and producing earthquake catalogs that are uncontaminated by mining blasts. Here, we examine the depth sensitivity of several physics-based waveform features for ~8000 earthquakes in southern California that have well-resolved depths from arrival-time inversion. We focus on small earthquakes (2 < M L < 4) recorded at local distances (<150 km), for which depth estimation is especially challenging. We find that differential magnitudes (M w /M L –M c ) are positively correlated with focal depth, implying that coda wave excitation decreases with focal depth. We analyze a simple proxy for relative frequency content, Φ≡log 10 (M 0 )+3log 10 (f c ), and find that source spectra are preferentially enriched in high frequencies, or “blue-shifted,” as focal depth increases. Here, we also find that two spectral amplitude ratios Rg 0.5–2 Hz/Sg 0.5–8 Hz and Pg/Sg at 3–8 Hz decrease as focal depth increases. Using multilinear regression with these features as predictor variables, we develop models that can explain 11%–59% of the variance in depths within 10 subregions and 25% of the depth variance across southern California as a whole. We suggest that incorporating these features into a machine learning workflow could help resolve focal depths in regions that are poorly instrumented and lack large databases of well-located events. Some of the waveform features we evaluate in this study have previously been used as source discriminants, and our results imply that their effectiveness in discrimination is partially because explosions generally occur at shallower depths than earthquakes.

58 GEOSCIENCES↗

On-Orbit Measurement of the Focal Length of the SNPP VIIRS Instrument

The Visible Infrared Imaging Radiometer Suite (VIIRS) instrument is a whiskbroom system with 22 spectral bands split between 16 moderate resolution bands (M-bands), five imagery resolution bands (I-bands) and a panchromatic day-night band. Latitude and Longitude geolocation data are generated for each pixel at the M-band, I-band and day-night band spatial resolutions based upon various instrument parameters including focal length. In this study we measure the focal length of the VIIRS instrument from on-orbit data. This is achieved by simulating VIIRS band I2 using Landsat 8 OLI band 5 utilizing the VIIRS instrument system point spread function (PSF) and geolocation data generated with varying values of focal length. The focal length value that produces the highest spatial correlation between the original and simulated VIIRS data is taken to be the measured instrument focal length.

Image analysis↗

Focal adhesion kinase is involved in mechanosensing during fibroblast migration

Focal adhesion kinase (FAK) is a non-receptor protein tyrosine kinase localized at focal adhesions and is believed to mediate adhesion-stimulated effects. Although ablation of FAK impairs cell movement, it is not clear whether FAK might be involved in the guidance of cell migration, a role consistent with its putative regulatory function. We have transfected FAK-null fibroblasts with FAK gene under the control of the tetracycline repression system. Cells were cultured on flexible polyacrylamide substrates for the detection of traction forces and the application of mechanical stimulation. Compared with control cells expressing wild-type FAK, FAK-null cells showed a decrease in migration speed and directional persistence. In addition, whereas FAK-expressing cells responded to exerted forces by reorienting their movements and forming prominent focal adhesions, FAK-null cells failed to show such responses. Furthermore, FAK-null cells showed impaired responses to decreases in substrate flexibility, which causes control cells to generate weaker traction forces and migrate away from soft substrates. Cells expressing Y397F FAK, which cannot be phosphorylated at a key tyrosine site, showed similar defects in migration pattern and force-induced reorientation as did FAK-null cells. However, other aspects of F397-FAK cells, including the responses to substrate flexibility and the amplification of focal adhesions upon mechanical stimulation, were similar to that of control cells. Our results suggest that FAK plays an important role in the response of migrating cells to mechanical input. In addition, phosphorylation at Tyr-397 is required for some, but not all, of the functions of FAK in cell migration.

NASA Discipline Cell Biology↗

Long-Wavelength Infrared (LWIR) Quantum Dot Infrared Photodetector (QDIP) Focal Plane Array

We have exploited the artificial atomlike properties of epitaxially self-assembled quantum dots for the development of high operating temperature long wavelength infrared (LWIR) focal plane arrays. Quantum dots are nanometer-scale islands that form spontaneously on a semiconductor substrate due to lattice mismatch. QDIPs are expected to outperform quantum well infrared detectors (QWIPs) and are expected to offer significant advantages over II-VI material based focal plane arrays. QDIPs are fabricated using robust wide bandgap III-V materials which are well suited to the production of highly uniform LWIR arrays. We have used molecular beam epitaxy (MBE) technology to grow multi-layer LWIR quantum dot structures based on the InAs/InGaAs/GaAs material system. JPL is building on its significant QWIP experience and is basically building a Dot-in-the-Well (DWELL) device design by embedding InAs quantum dots in a QWIP structure. This hybrid quantum dot/quantum well device offers additional control in wavelength tuning via control of dot-size and/or quantum well sizes. In addition the quantum wells can trap electrons and aide in ground state refilling. Recent measurements have shown a 10 times higher photoconductive gain than the typical QWIP device, which indirectly confirms the lower relaxation rate of excited electrons (photon bottleneck) in QDPs. Subsequent material and device improvements have demonstrated an absorption quantum efficiency (QE) of approx. 3%. Dot-in-the-well (DWELL) QDIPs were also experimentally shown to absorb both 45 deg. and normally incident light. Thus we have employed a reflection grating structure to further enhance the quantum efficiency. JPL has demonstrated wavelength control by progressively growing material and fabricating devices structures that have continuously increased in LWIR response. The most recent devices exhibit peak responsivity out to 8.1 microns. Peak detectivity of the 8.1 micrometer devices has reached approx. 1 x 10(exp 10) Jones at 77 K. Furthermore, we have fabricated the first long-wavelength 640x512 pixels QDP focal plane array. This QDIP focal plane may has produced excellent infrared imagery with noise equivalent temperature difference of 40 mK at 60K operating temperature. In addition, we have managed to increase the quantum efficiency of these devices from 0.1% (according to the data published in literature) to 20% in discrete devices. This is a factor of 200 increase in quantum efficiency. With these excellent results, for the first time QDIP performance has surpassed the QWIP performance. Our goal is to operate these long-wavelength detectors at much higher operating temperature than 77K which can be passively achieved in space. This will be a huge leap in high performance infrared detectors specifically applicable to space science instruments.

infrared imaging↗

Towards Dualband Megapixel QWIP Focal Plane Arrays

Mid-wavelength infrared (MWIR) and long-wavelength infrared (LWIR) 1024 x 1024 pixel quantum well infrared photodetector (QWIP) focal planes have been demonstrated with excellent imaging performance. The MWIR QWIP detector array has demonstrated a noise equivalent differential temperature (NEDT) of 17 mK at a 95 K operating temperature with f/2.5 optics at 300 K background and the LWIR detector array has demonstrated a NEDT of 13 mK at a 70 K operating temperature with the same optical and background conditions as the MWIR detector array after the subtraction of system noise. Both MWIR and LWIR focal planes have shown background limited performance (BLIP) at 90 K and 70 K operating temperatures respectively, with similar optical and background conditions. In addition, we have demonstrated MWIR and LWIR pixel co-registered simultaneously readable dualband QWIP focal plane arrays. In this paper, we will discuss the performance in terms of quantum efficiency, NEDT, uniformity, operability, and modulation transfer functions of the 1024 x 1024 pixel arrays and the progress of dualband QWIP focal plane array development work.

Infrared detectors↗

MWIR and LWIR Megapixel QWIP Focal Plane Arrays

A mid-wavelength infrared (MWIR) and long-wavelength infrared (LWIR) 1024x1024 pixel quantum well infrared photodetector (QWIP) focal plane array has been demonstrated with excellent imagery. MWIR focal plane has given noise equivalent differential temperature (NETD) of 19 mK at 95K operating temperature with f/2.5 optics at 300K background and LWIR focal plane has given NEDT of 13 mK at 70K operating temperature with same optical and background conditions as MWIR array. Both of these focal plane arrays have shown background limited performance (BLIP) at 90K and 70K operating temperatures with the same optics and background conditions. In this paper, we will discuss their performance in quantum efficiency, NETD, uniformity, and operability.

multi band↗

Temporal changes in MRI appearance of the prostate after focal ablation

Purpose: The purpose of our study was to retrospectively evaluate and categorize temporal changes in MRI appearances of the prostate in patients who underwent focal therapy with MRI follow-up. Methods: The Institutional Review Board approved this retrospective study and waived the requirement for informed consent. Thirty-seven patients (median age 61; 48–70 years) with low-to-intermediate-risk, clinically organ-confined prostate cancer underwent focal ablation therapy from 2009 to 2014. Two radiologists reviewed post-treatment MRIs (n = 76) and categorized imaging features blinded to the time interval between the focal therapy and the follow-up MRI. Inter-reader agreement was assessed (kappa) and generalized linear regression was used to examine associations between an imaging feature being present/absent and days between ablation and MRI. Results: Inter-reader agreement on MRI features ranged from fair to substantial. Edema was found present at earlier times after ablation (median 16–25 days compared to MRIs without edema, median 252–514 days), as was rim enhancement of the ablation zone (18–22.5 days vs. 409–593 days), a hypointense rim around the ablation zone on T2-weighted images (53-57.5 days vs. 279–409 days) and the presence of an appreciable ablation cavity (48.5–60 days vs. 613–798 days, all p < 0.05). Enhancement of the ablation zone/scar (553–731 days vs. 61.5–162 days) and the formation of a T2-hypointense scar were found to be present on later MRI scans (514–553 days vs. 29–32 days, one reader). Conclusions: The MRI appearance of the prostate after focal ablation changes substantially over time. Identification of temporal patterns in the appearance of imaging features should help reduce image interpretation variability and errors when assessing post-therapeutic scans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization and performance of the second-year SPT-3G focal plane

The third-generation instrument for the 10-meter South Pole Telescope, SPT-3G, was first installed in January 2017. In addition to completely new cryostats, secondary telescope optics, and readout electronics, the number of detectors in the focal plane has increased by an order of magnitude from previous instruments to ~16,000. The SPT-3G focal plane consists of ten detector modules, each with an array of 269 trichroic, polarization-sensitive pixels on a six-inch silicon wafer. Within each pixel is a broadband, dual-polarization sinuous antenna; the signal from each orthogonal linear polarization is divided into three frequency bands centered at 95, 150, and 220 GHz by in-line lumped element filters and transmitted via superconducting microstrip to Ti/Au transition-edge sensor (TES) bolometers. Properties of the TES film, microstrip filters, and bolometer island must be tightly controlled to achieve optimal performance. For the second year of SPT-3G operation, we have replaced all ten wafers in the focal plane with new detector arrays tuned to increase mapping speed and improve overall performance. Here we discuss the TES superconducting transition temperature and normal resistance, detector saturation power, bandpasses, optical efficiency, and full array yield for the 2018 focal plane.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗