Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “focal”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

1024x1024 Pixel MWIR and LWIR QWIP Focal Plane Arrays and 320x256 MWIR:LWIR Pixel Colocated Simultaneous Dualband QWIP Focal Plane Arrays

Mid-wavelength infrared (MWIR) and long-wavelength infrared (LWIR) 1024x1024 pixel quantum well infrared photodetector (QWIP) focal planes have been demonstrated with excellent imaging performance. The MWIR QWIP detector array has demonstrated a noise equivalent differential temperature (NE(Delta)T) of 17 mK at a 95K operating temperature with f/2.5 optics at 300K background and the LWIR detector array has demonstrated a NE(Delta)T of 13 mK at a 70K operating temperature with the same optical and background conditions as the MWIR detector array after the subtraction of system noise. Both MWIR and LWIR focal planes have shown background limited performance (BLIP) at 90K and 70K operating-temperatures respectively, with similar optical and background conditions. In addition, we are in the process of developing MWIR and LWIR pixel collocated simultaneously readable dualband QWIP focal plane arrays.

quantum wells↗

Single-shot, phase-diversity phase retrieval for high-energy beam focal-spot diagnostics

A single-shot, phase-diversity phase-retrieval method is demonstrated for directly characterizing the on-target focal spot at kilojoule energy in the OMEGA 60-beam laser. A 2D holographic grating that introduces diversity focal spots is installed in an existing on-target focal-spot diagnostic to obtain a single-shot diversity focal-spot image. A nonlinear optimization phase-retrieval algorithm with four diversity focal spots is employed to determine modal coefficients for the incident wavefront. The agreement between the measured and calculated focal spots is excellent. Furthermore, this approach can be easily adapted for other high-energy focal-spot diagnostics.

47 OTHER INSTRUMENTATION↗

Acoustic Amplification in the Far Infrared Focal Plane Assembly of the Composite Infrared Spectrometer (CIRS) for the Cassini Mission to Saturn

The Composite Infrared Spectrometer (CIRS) of the Cassini mission to Saturn has two interferometers covering the far infrared FIR and mid infrared, MIR wavelength region. The FIR is a polarizing Michelson interferometer which presents a collimated output beam to the FIR focal plane. The focal plane consists of a parabolic focus mirror and an analyzer grid, which splits the output beams into transmitted and reflected components. The two polarizations are focussed onto two thermopile detectors; each consisting of a gold black foil welded to the top of two bismuth pyramids. The gold black is 30 microns thick, and the weld area is approximately 2 microns in diameter. The detectors are extremely fragile and the weld can be broken with a miniscule amount of airflow. The detectors consistently passed acoustic testing to qualification levels that simulated the launch environment of the Titan IV launch vehicle. However, they experienced a 50% failure rate when installed in the focal plane assembly during instrument level acoustic tests. A test focal plane was developed with small pressure transducers in the nominal detector locations. These tests indicated over 10 dB of acoustic amplification in the focal plane within the instrument during testing. New techniques were developed to allow testing of the focal plane without over testing the instrument, and modifications were made the focal plane assembly to successfully attenuate the amplification.

Hagopian, John G.↗

Curved-Focal-Plane Arrays Using Deformed-Membrane Photodetectors

A versatile and simple approach to the design and fabrication of curved-focal-plane arrays of silicon-based photodetectors is being developed. This approach is an alternative to the one described in "Curved Focal-Plane Arrays Using Back- Illuminated High-Purity Photodetectors" (NPO-30566), NASA Tech Briefs, Vol. 27, No. 10 (October 2003), page 10a. As in the cited prior article, the basic idea is to improve the performance of an imaging instrument and simplify the optics needed to obtain a given level of performance by making an image sensor (in this case, an array of photodetectors) conform to a curved focal surface, instead of designing the optics to project an image onto a flat focal surface. There is biological precedent for curved-focal-surface designs: retinas - the image sensors in eyes - conform to the naturally curved focal surfaces of eye lenses. The present approach is applicable to both front-side- and back-side-illuminated, membrane photodetector arrays and is being demonstrated on charge-coupled devices (CCDs). The very-large scale integrated (VLSI) circuitry of such a CCD or other array is fabricated on the front side of a silicon substrate, then the CCD substrate is attached temporarily to a second substrate for mechanical support, then material is removed from the back to obtain the CCD membrane, which typically has a thickness between 10 and 20 m. In the case of a CCD designed to operate in back-surface illumination, delta doping can be performed after thinning to enhance the sensitivity. This approach is independent of the design and method of fabrication of the front-side VLSI circuitry and does not involve any processing of a curved silicon substrate. In this approach, a third substrate would be prepared by polishing one of its surfaces to a required focal-surface curvature. A CCD membrane fabricated as described above would be pressed against, deformed into conformity with, and bonded to, the curved surface. The technique used to press and bond the CCD membrane would depend on the nature of the supporting material (see figure). For example, if the third substrate were made of quartz frit, the substrate would be prepared by suffusing it with epoxy. Then one would take advantage of the porosity of the frit by applying a partial vacuum to the opposite surface of the frit, causing atmospheric pressure to push the CCD membrane against the curved surface. The curing of the epoxy would bond the CCD membrane to the curved surface. Alternatively, if the third substrate were made of a nonporous material, the curved substrate surface would be prepared by coating it with a wax or an uncured epoxy. The CCD membrane would be pressed against the coated, curved surface by use of a suitably pressurized balloon. The CCD membrane would then become bonded to the curved surface by curing of the epoxy or freezing of the wax.

Nikzad, Shouleh↗

Curved Focal-Plane Arrays Using Back-Illuminated High-Purity Photodetectors

Curved-focal-plane arrays of back-illuminated silicon-based photodetectors are being developed. The basic idea is to improve the performance of an imaging instrument and simplify the optics needed to obtain a given level of performance by making an image sensor (e.g., a photographic film or an array of photodetectors) conform to a curved focal surface, instead of following the customary practice of designing the optics to project an image onto a flat focal surface. Eyes are natural examples of optical systems that have curved focal surfaces on which image sensors (retinas) are located. One prior approach to implementation of this concept involves the use of curved-input-surface microchannel plates as arrays of photodetectors. In comparison with microchannel plates, these curved-focal-plane arrays would weigh less, operate at much lower voltages, and consume less power. It should also be possible to fabricate the proposed devices at lower cost. It would be possible to fabricate an array of photodetectors and readout circuitry in the form of a very-large-scale integrated (VLSI) circuit on a curved focal surface, but it would be difficult and expensive to do so. In a simple and inexpensive alternate approach, a device (see figure) would have (1) a curved back surface, onto which light would be focused; and (2) a flat front surface, on which VLSI circuitry would be fabricated by techniques that are well established for flat surfaces. The device would be made from ultrapure silicon, in which it is possible to form high-resistivity, thick photodetectors that are fully depleted through their thicknesses. (As used here, "thick means having a thickness between a fraction of a millimeter and a few millimeters.) The back surface would be polished to the curvature of the focal surface of the intended application. To enable the collection of charge carriers excited by photons near the back surface or in the bulk of the device, it would be necessary to form a transparent or semitransparent back-surface electrode, possibly by delta doping. [Delta doping is so named because its density-vs.-depth characteristic is reminiscent of the Dirac function (impulse function): the dopant is concentrated in a very thin layer - nominally, a single atomic layer.]

Nikzad, Shouleh↗

Performance of an Achromatic Focal Plane Mask for Exoplanet Imaging Coronagraphy

Coronagraph technology combined with wavefront control is close to achieving the contrast and inner working angle requirements in the lab necessary to observe the faint signal of an Earth-like exoplanet in monochromatic light. An important remaining technological challenge is to achieve high contrast in broadband light. Coronagraph bandwidth is largely limited by chromaticity of the focal plane mask, which is responsible for blocking the stellar PSF. The size of a stellar PSF scales linearly with wavelength; ideally, the size of the focal plane mask would also scale with wavelength. A conventional hard-edge focal plane mask has a fixed size, normally sized for the longest wavelength in the observational band to avoid starlight leakage. The conventional mask is oversized for shorter wavelengths and blocks useful discovery space. Recently we presented a solution to the size chromaticity challenge with a focal plane mask designed to scale its effective size with wavelength. In this paper, we analyze performance of the achromatic size-scaling focal plane mask within a Phase Induced Amplitude Apodization (PIAA) coronagraph. We present results from wavefront control around the achromatic focal plane mask, and demonstrate the size-scaling effect of the mask with wavelength. The edge of the dark zone, and therefore the inner working angle of the coronagraph, scale with wavelength. The achromatic mask enables operation in a wider band of wavelengths compared with a conventional hard-edge occulter.

Focal Plane Mask↗

Focal axis resolver for offset reflector antennas

Method and apparatus for determining the focal axis of an asymmetrical antenna such as an offset paraboloid reflector whose physical rim is not coincident with the boundary of the electrical aperture but whose focal point is known is provided. A transmitting feed horn array consisting of at least two feed horn elements is positioned asymmetrically on either side of an estimated focal axis which is generally inclined with respect to the boresight axis of the antenna. The feed horn array is aligned with the estimated focal axis so that the phase centers (CP sub 1, CP sub 2) of the two feed horn elements are located on a common line running through the focal point (F) orthogonally with respect to the estimated focal axis.

Schmidt, R. F.↗

Diagnostic accuracy of F-18 FDG PET/CT for characterization of colorectal focal FDG uptake: a systematic review and meta-analysis

Introduction: We aimed to explore the role of the diagnostic accuracy of F-18 fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) for characterization of incidental colorectal focal FDG uptake through a systematic review and meta-analysis. Methods: The MEDLINE, EMBASE, and Cochrane Library database, from the earliest available date of indexing through April 30, 2018, were searched for studies evaluating the diagnostic performance of F-18 FDG PET/CT for characterization of incidental colorectal focal FDG uptake. We determined the sensitivities and specificities across studies, calculated positive and negative likelihood ratios (LR+ and LR−), and constructed summary receiver operating characteristic curves. Results: Across 8 studies (1451 patients), the pooled sensitivity for F-18 FDG PET/CT was 0.87 (95% CI 0.82–0.90) without heterogeneity (χ{sup 2} = 10.84, p = 0.37) and a pooled specificity of 0.83 (95% CI 0.76–0.89) with heterogeneity (χ{sup 2} = 130.1, p = 0.00). Likelihood ratio (LR) syntheses gave an overall positive likelihood ratio (LR+) of 5.2 (95% CI 3.6–7.4) and negative likelihood ratio (LR−) of 0.16 (95% CI 0.12–0.22). The pooled DOR was 32 (95% CI 20–51). Conclusion: F-18 FDG PET/CT demonstrated good sensitivity and specificity for characterization of incidental colorectal focal FDG uptake. At present, the literature regarding the use of F-18 FDG PET/CT for characterization of incidental colorectal focal FDG uptake remains still limited; thus, further large multicenter studies would be necessary to substantiate the diagnostic accuracy of F-18 FDG PET/CT for characterization of incidental colorectal focal FDG uptake.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Focal mass-like cardiac uptake on oncologic FDG PET/CT: Real lesion or atypical pattern of physiologic uptake?

Background: Cardiac uptake on oncologic FDG PET/CT can be unpredictable. Focal or mass-like cardiac uptake not confined to normal pattern is a real challenge for interpretation due to great variability in physiologic uptake and rarity of either primary or metastatic cardiac neoplasms. Methods and Results: Eight patients with suspicious mass-like cardiac uptake on oncologic FDG PET/CT were retrospectively analyzed with correlation to cardiac workups including contrast CT, echocardiography, and repeat PET/CT. Four patients had real cardiac lesions or metastases. Focal uptake was benign and might represent papillary muscle in the other four. SUV{sub max} ratio between the cardiac focus and surrounding background cardiac uptake was statistically higher in the true-positive group than that in the false-positive group. In addition, the patients with true-positive cardiac uptake had more diffuse distant metastases compared to those with false-positive cardiac uptake. Conclusions: Focal suspicious cardiac uptake on oncology FDG PET/CT warranted further evaluation. SUV{sub max} ratio between the cardiac focus and surrounding background cardiac uptake and status of distant metastases might help to differentiate malignant from benign nature of the focal cardiac uptake on FDG PET/CT. Focal uptake of the right ventricle on oncologic FDG PET/CT is more likely suggestive of a neoplasm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Approximating large-basis coupled-cluster theory vibrational frequencies using focal-point approximations

The focal-point approximation can be used to estimate a high-accuracy, slow quantum chemistry computation by combining several lower-accuracy, faster computations. We examine the performance of focal-point methods by combining second-order Møller–Plesset perturbation theory (MP2) with coupled-cluster singles, doubles, and perturbative triples [CCSD(T)] for the calculation of harmonic frequencies and that of fundamental frequencies using second-order vibrational perturbation theory (VPT2). In contrast to standard CCSD(T), the focal-point CCSD(T) method approaches the complete basis set (CBS) limit with only triple-ζ basis sets for the coupled-cluster portion of the computation. The predicted harmonic and fundamental frequencies were compared with the experimental values for a set of 20 molecules containing up to six atoms. Here, the focal-point method combining CCSD(T)/aug-cc-pV(T + d)Z with CBS-extrapolated MP2 has mean absolute errors vs experiment of only 7.3 cm −1 for the fundamental frequencies, which are essentially the same as the mean absolute error for CCSD(T) extrapolated to the CBS limit using the aug-cc-pV(Q + d)Z and aug-cc-pV(5 + d)Z basis sets. However, for H 2 O, the focal-point procedure requires only 3% of the computation time as the extrapolated CCSD(T) result, and the cost savings will grow for larger molecules.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-speed Focal Plane Wave Front Sensing with an Optical Chopper

Focal plane wave front sensing and control is a critical approach to reducing noncommon path errors between a conventional astronomical adaptive optics (AO) wave front sensor (WFS) detector and a science camera. However, in addition to mitigating noncommon path errors, recent focal plane wave front sensing techniques have been developed to operate at speeds fast enough to enable "multi-WFS" AO, where residual atmospheric errors are further corrected by a focal plane WFS. Although a number of such techniques have been recently developed for coronagraphic imaging, here we present one designed for noncoronagraphic imaging. Utilizing conventional AO system components, this concept additionally requires (1) a detector imaging the focal plane of the WFS light source and (2) a pupil plane optical chopper device that is the noncommon path to the first WFS and is synchronized to the focal plane imager readout. These minimal hardware requirements enable the temporal amplitude modulation to resolve the sine ambiguity of even wave-front modes for low, mid, and high wave front spatial frequencies. Similar capabilities have been demonstrated with classical phase diversity by defocusing the detector, but such techniques are incompatible with simultaneous science observations. This optical chopping technique, however, enables science imaging at up to 50% duty cycle. In conclusion, we present both simulations and laboratory validation of this concept on SEAL, the Santa Cruz Extreme AO Laboratory testbed.

79 ASTRONOMY AND ASTROPHYSICS↗

Microseismic Focal Mechanisms and Implications for Changes in Stress during the 2014 Newberry EGS Stimulation

We adapt the relative polarity method from Shelly et al. (2016) to compute focal mechanisms for microearthquakes associated with the 2014 hydroshearing stimulation at the Newberry volcano geothermal site. We focus the analysis on events relocated by Aguiar and Myers (2018), who report that six event clusters predominantly comprise the 2014 sequence. Data quality allows focal mechanism analysis for four of the six event clusters. We use Hardebeck and Shearer (2002, 2003; hereafter HASH) to compute focal mechanisms based on first–motion polarities and S/P amplitude ratios. We manually determine P– and S–wave polarities for a well–recorded reference event in each cluster, then use waveform cross correlation to determine whether recordings of other events in the cluster are the same or reversed polarity at each network station. Here, most waveform polarities are consistent with the affiliated reference event, indicating similar focal mechanisms within each cluster. The deeper clusters are east–west–striking normal faults, whereas the shallower clusters, close to the top of the open–hole section of the borehole, are strike slip with east–west motion. Regional studies and prestimulation borehole breakouts find the maximum stress direction is vertical and maximum horizontal stress is approximately north–south. Fault geometry and focal mechanisms of microseismicity during the stimulation suggest that increased pressure from fluid injection predominantly caused changes in horizontal stress, consistent with predictions from numerical studies of stress change caused by fluid injection. At shallow depths, where previous studies suggest the difference between vertical and horizontal stress is lowest, injection appears to have rotated the direction of maximum stress from vertical to horizontal, resulting in strike–slip motion. At greater depth, vertical stress continued to be the dominant direction during the stimulation, but fault orientation indicates either reactivation of pre–existing fractures or rotation of the direction of maximum horizontal stress from approximately north–south to east–west.

15 GEOTHERMAL ENERGY↗

Inferring the Focal Depths of Small Earthquakes in Southern California Using Physics-Based Waveform Features

Determining the depths of small crustal earthquakes is challenging in many regions of the world, because most seismic networks are too sparse to resolve trade-offs between depth and origin time with conventional arrival-time methods. Precise and accurate depth estimation is important, because it can help seismologists discriminate between earthquakes and explosions, which is relevant to monitoring nuclear test ban treaties and producing earthquake catalogs that are uncontaminated by mining blasts. Here, we examine the depth sensitivity of several physics-based waveform features for ~8000 earthquakes in southern California that have well-resolved depths from arrival-time inversion. We focus on small earthquakes (2 < M L < 4) recorded at local distances (<150 km), for which depth estimation is especially challenging. We find that differential magnitudes (M w /M L –M c ) are positively correlated with focal depth, implying that coda wave excitation decreases with focal depth. We analyze a simple proxy for relative frequency content, Φ≡log 10 (M 0 )+3log 10 (f c ), and find that source spectra are preferentially enriched in high frequencies, or “blue-shifted,” as focal depth increases. Here, we also find that two spectral amplitude ratios Rg 0.5–2 Hz/Sg 0.5–8 Hz and Pg/Sg at 3–8 Hz decrease as focal depth increases. Using multilinear regression with these features as predictor variables, we develop models that can explain 11%–59% of the variance in depths within 10 subregions and 25% of the depth variance across southern California as a whole. We suggest that incorporating these features into a machine learning workflow could help resolve focal depths in regions that are poorly instrumented and lack large databases of well-located events. Some of the waveform features we evaluate in this study have previously been used as source discriminants, and our results imply that their effectiveness in discrimination is partially because explosions generally occur at shallower depths than earthquakes.

58 GEOSCIENCES↗

On-Orbit Measurement of the Focal Length of the SNPP VIIRS Instrument

The Visible Infrared Imaging Radiometer Suite (VIIRS) instrument is a whiskbroom system with 22 spectral bands split between 16 moderate resolution bands (M-bands), five imagery resolution bands (I-bands) and a panchromatic day-night band. Latitude and Longitude geolocation data are generated for each pixel at the M-band, I-band and day-night band spatial resolutions based upon various instrument parameters including focal length. In this study we measure the focal length of the VIIRS instrument from on-orbit data. This is achieved by simulating VIIRS band I2 using Landsat 8 OLI band 5 utilizing the VIIRS instrument system point spread function (PSF) and geolocation data generated with varying values of focal length. The focal length value that produces the highest spatial correlation between the original and simulated VIIRS data is taken to be the measured instrument focal length.

Image analysis↗

Focal adhesion kinase is involved in mechanosensing during fibroblast migration

Focal adhesion kinase (FAK) is a non-receptor protein tyrosine kinase localized at focal adhesions and is believed to mediate adhesion-stimulated effects. Although ablation of FAK impairs cell movement, it is not clear whether FAK might be involved in the guidance of cell migration, a role consistent with its putative regulatory function. We have transfected FAK-null fibroblasts with FAK gene under the control of the tetracycline repression system. Cells were cultured on flexible polyacrylamide substrates for the detection of traction forces and the application of mechanical stimulation. Compared with control cells expressing wild-type FAK, FAK-null cells showed a decrease in migration speed and directional persistence. In addition, whereas FAK-expressing cells responded to exerted forces by reorienting their movements and forming prominent focal adhesions, FAK-null cells failed to show such responses. Furthermore, FAK-null cells showed impaired responses to decreases in substrate flexibility, which causes control cells to generate weaker traction forces and migrate away from soft substrates. Cells expressing Y397F FAK, which cannot be phosphorylated at a key tyrosine site, showed similar defects in migration pattern and force-induced reorientation as did FAK-null cells. However, other aspects of F397-FAK cells, including the responses to substrate flexibility and the amplification of focal adhesions upon mechanical stimulation, were similar to that of control cells. Our results suggest that FAK plays an important role in the response of migrating cells to mechanical input. In addition, phosphorylation at Tyr-397 is required for some, but not all, of the functions of FAK in cell migration.

NASA Discipline Cell Biology↗

Long-Wavelength Infrared (LWIR) Quantum Dot Infrared Photodetector (QDIP) Focal Plane Array

We have exploited the artificial atomlike properties of epitaxially self-assembled quantum dots for the development of high operating temperature long wavelength infrared (LWIR) focal plane arrays. Quantum dots are nanometer-scale islands that form spontaneously on a semiconductor substrate due to lattice mismatch. QDIPs are expected to outperform quantum well infrared detectors (QWIPs) and are expected to offer significant advantages over II-VI material based focal plane arrays. QDIPs are fabricated using robust wide bandgap III-V materials which are well suited to the production of highly uniform LWIR arrays. We have used molecular beam epitaxy (MBE) technology to grow multi-layer LWIR quantum dot structures based on the InAs/InGaAs/GaAs material system. JPL is building on its significant QWIP experience and is basically building a Dot-in-the-Well (DWELL) device design by embedding InAs quantum dots in a QWIP structure. This hybrid quantum dot/quantum well device offers additional control in wavelength tuning via control of dot-size and/or quantum well sizes. In addition the quantum wells can trap electrons and aide in ground state refilling. Recent measurements have shown a 10 times higher photoconductive gain than the typical QWIP device, which indirectly confirms the lower relaxation rate of excited electrons (photon bottleneck) in QDPs. Subsequent material and device improvements have demonstrated an absorption quantum efficiency (QE) of approx. 3%. Dot-in-the-well (DWELL) QDIPs were also experimentally shown to absorb both 45 deg. and normally incident light. Thus we have employed a reflection grating structure to further enhance the quantum efficiency. JPL has demonstrated wavelength control by progressively growing material and fabricating devices structures that have continuously increased in LWIR response. The most recent devices exhibit peak responsivity out to 8.1 microns. Peak detectivity of the 8.1 micrometer devices has reached approx. 1 x 10(exp 10) Jones at 77 K. Furthermore, we have fabricated the first long-wavelength 640x512 pixels QDP focal plane array. This QDIP focal plane may has produced excellent infrared imagery with noise equivalent temperature difference of 40 mK at 60K operating temperature. In addition, we have managed to increase the quantum efficiency of these devices from 0.1% (according to the data published in literature) to 20% in discrete devices. This is a factor of 200 increase in quantum efficiency. With these excellent results, for the first time QDIP performance has surpassed the QWIP performance. Our goal is to operate these long-wavelength detectors at much higher operating temperature than 77K which can be passively achieved in space. This will be a huge leap in high performance infrared detectors specifically applicable to space science instruments.

infrared imaging↗

Towards Dualband Megapixel QWIP Focal Plane Arrays

Mid-wavelength infrared (MWIR) and long-wavelength infrared (LWIR) 1024 x 1024 pixel quantum well infrared photodetector (QWIP) focal planes have been demonstrated with excellent imaging performance. The MWIR QWIP detector array has demonstrated a noise equivalent differential temperature (NEDT) of 17 mK at a 95 K operating temperature with f/2.5 optics at 300 K background and the LWIR detector array has demonstrated a NEDT of 13 mK at a 70 K operating temperature with the same optical and background conditions as the MWIR detector array after the subtraction of system noise. Both MWIR and LWIR focal planes have shown background limited performance (BLIP) at 90 K and 70 K operating temperatures respectively, with similar optical and background conditions. In addition, we have demonstrated MWIR and LWIR pixel co-registered simultaneously readable dualband QWIP focal plane arrays. In this paper, we will discuss the performance in terms of quantum efficiency, NEDT, uniformity, operability, and modulation transfer functions of the 1024 x 1024 pixel arrays and the progress of dualband QWIP focal plane array development work.

Infrared detectors↗