Engineering PapersSearch

SEARCH · Engineering Papers

Results for “flux”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Probabilistic flux limiters

The stable numerical integration of shocks in compressible flow simulations relies on the reduction or elimination of Gibbs phenomena (unstable, spurious oscillations). A popular method to virtually eliminate Gibbs oscillations caused by numerical discretization in under-resolved simulations is to use a flux limiter. A wide range of flux limiters have been studied in the literature, with recent interest in their optimization via machine learning methods trained on high-resolution datasets. The common use of flux limiters in numerical codes as plug-and-play blackbox components makes them key targets for design improvement. Even for deterministic dynamical models, numerical uncertainty is introduced via coarse-graining required by insufficient computational power to solve all scales of motion. Conventional flux limiters are deterministic and lack the capacity to address uncertainties, both aleatoric (inherent randomness) and epistemic (modeling uncertainty due to limited knowledge), which arise in coarse-grained numerical simulations. Here, we introduce a conceptually distinct type of flux limiter that is designed to handle the effects of randomness in the model and uncertainty in model parameters. Unlike traditional single-function flux limiters, these new probabilistic flux limiters incorporate multiple flux limiting functions, each applied with a learned probability drawn from high-resolution data to mitigate the effects of uncertainty in numerical simulations. This approach departs from traditional single-function limiters by explicitly modeling and incorporating uncertainty into the shock capturing process. Using the example of Burgers' equation as a testbed, we show that a machine learned, probabilistic flux limiter may be used in a shock capturing code to more accurately capture shock profiles. In particular, we show that our probabilistic flux limiter outperforms standard limiters and can be successively improved upon (up to a point) by expanding the set of probabilistically chosen flux limiting functions.

97 MATHEMATICS AND COMPUTING

Investigation of Flux Spreading in a Light-Trapping, Planar-Cavity Receiver for Enclosed Solar Particle Heating

Concentrating solar thermal power (CSP) technology development has recently focused on increasing the operating temperatures to accommodate high efficiency power cycles and thermochemical processes. Inert solid particles as heat transfer media enable solar receivers to operate above 700 degrees Celsius resulting in increased system thermal efficiency compared to the conventional molten salt based CSP system. An open-cavity falling-particle solar receiver that can efficiently heat particles by direct heating from concentrated solar radiation faces challenges with large particle losses from wind and unable to support thermochemical reactions. A light-trapping, planar cavity reiver (LTPCR) where particles are indirectly heated can significantly minimize the particle losses during the operation, support thermochemical reactions, and offer scalability potential. The LTPCR features an array of vertical planar receiver/absorber panels arranged within a cavity configuration. Concentrated solar radiation from heliostats is focused onto the receiver walls, where heat is indirectly transferred to solid particles flowing inside the receiver channels. Heat transfer occurs through direct contact between the receiver panel walls and particles, and can be enhanced by fluidizing particles with air. This fluidization increases particle-wall contact and extends particle residence time, maximizing heat transfer efficiency. The unique vertical planar receiver structure originated from a near-blackbody tubular light absorber, effectively distributing the incoming solar beam spread across the panel walls and trapping light. This flux spreading effect, driven by cosine projection, converts high incident solar flux into a lower, more uniform heat flux on the panel walls. This redistribution enhances heat transfer efficiency between particle-wall or reaction gases-wall, while preventing localized overheating of the receiver panel. Indirect planar cavity solar receivers completely separate solid particles from the ambient environment that can greatly reduce the thermal losses in heated particles resulting in high efficiency at high temperatures above 700 degrees Celsius. This design ensures no particle losses to the environment during the operation while open-cavity designs can experience significant particle losses from wind. An experimental investigation was conducted to observe flux spreading on the receiver panel wall. A lab-scale prototype planar receiver, fabricated using Haynes 230 alloy, was tested under direct concentrated solar radiation using the high-flux solar furnace (HFSF) facility at NREL. The experiment was performed under normal peak radiative heat fluxes ranging from 800 to 1900 kW/m2. A temperature distribution on the panel wall was measured using a thermal imaging camera (FLIR A 6600). To prevent overheating at the receiver front tip, prism-shaped heat shields (Zircar UNIFROM C1) were placed in front of the receiver, and their influence on flux spreading was also studied. Absorbed flux distribution on the panel wall was modeled using SolTrace. The total solar power and flux distributions delivered from HFSF were determined based on the heliostat mirror optical properties, direct normal irradiance (DNI) on the on-sun testing days, peak flux measurement during the on-sun testing, and shutter/attenuator settings Due to the large incident angles of the solar beam on the panel wall, the angular optical properties of Haynes 230 alloy and Zircar heat shields were incorporated into the model. This flux distribution model was then integrated into a computational fluid dynamics (CFD) simulation to predict the receiver panel wall temperature, which was compared with the experimental measurements. Both prediction and measurements identified a temperature hotspot at the backside of the panel, indicating that the incident solar beam can fully reach to the rear of the receiver. The heat shields positioned at the front of the receiver effectively reduced the excessive temperature rise at the receiver front tip. Overall, the temperature was well distributed over the panel wall, with a minor hotspot at the back of the receiver. The model slightly overpredicted the temperature, possibly due to discrepancies in optical properties of the panel and an underprediction of thermal loss in the receiver. The advancement of the particle LTPCR offers a viable alternative to open-cavity receivers by addressing particle loss issues. Additionally, it presents a pathway for enabling solar thermochemical processes, extending CSP technology beyond power generation to fuel and chemical production.

14 SOLAR ENERGY

Is There a Scalar Atmospheric Surface Layer Within a Convective Boundary Layer? Implications for Flux Measurements

Top‐down entrainment shapes the vertical gradients of sensible heat, latent heat, and CO 2 fluxes, influencing the interpretation of eddy covariance (EC) measurements in the unstable atmospheric surface layer (ASL). Using large eddy simulations for convective boundary layer flows, we demonstrate that decreased temperature gradients across the entrainment zone increase entrainment fluxes by enhancing the entrainment velocity, amplifying the asymmetry between top‐down and bottom‐up flux contributions. These changes alter scalar flux profiles, causing flux divergence or convergence and leading to the breakdown of the constant flux layer assumption (CFLA) in the ASL. As a result, EC‐measured fluxes either underestimate or overestimate “true” surface fluxes during divergence or convergence phases, contributing to energy balance non‐closure. The varying degrees of the CFLA breakdown are a fundamental cause for the non‐closure issue. These findings highlight the underappreciated role of entrainment in interpreting EC fluxes, addressing non‐closure, and understanding site‐to‐site variability in flux measurements.

eddy covariance fluxes of scalars

3D modeling of n = 1 RMP driven heat fluxes on the SPARC tokamak PFCs using HEAT

3D heat flux calculations at the lower outer divertor plate of SPARC using the HEAT code show that 3D fields generated from error field correction coils can lead to enhanced peak heat fluxes up to 15 times larger compared to the axisymmetric case. Previously employed to simulate axisymmetric heat flux on 3D plasma facing components, the HEAT code can now predict 3D heat flux generated by non-axisymmetric plasmas. This is achieved via a new HEAT module which leverages the 3D field line tracing capabilities of MAFOT starting from an M3D-C1 (MHD resistive code) perturbed equilibria. The resulting heat flux is assigned using the magnetic footprint and the heat flux layer model, an extension of the 2D heat flux model also known as the Eich, to 3D non-axisymmetric plasmas. For SPARC, the new capabilities of HEAT are used to calculate the 3D heat loads resulting from n = 1 perturbation fields (with n indicating the toroidal periodicity) applied through a toroidal array of six picture frame coils with different amplitude. The comparison with the unperturbed case shows significant changes in shape and intensity of the heat flux profile. The results show that the application of n = 1 3D field leads to a localized enhancement of the heat flux peak, influenced by the wetted area impacted by the magnetic footprint, and the appearance of a secondary heat flux peak, whose intensity depends on amplitude of the applied 3D field and toroidal location.

3D heat flux

Methane fluxes in tidal marshes of the conterminous United States

Abstract Methane (CH 4 ) is a potent greenhouse gas (GHG) with atmospheric concentrations that have nearly tripled since pre‐industrial times. Wetlands account for a large share of global CH 4 emissions, yet the magnitude and factors controlling CH 4 fluxes in tidal wetlands remain uncertain. We synthesized CH 4 flux data from 100 chamber and 9 eddy covariance (EC) sites across tidal marshes in the conterminous United States to assess controlling factors and improve predictions of CH 4 emissions. This effort included creating an open‐source database of chamber‐based GHG fluxes ( https://doi.org/10.25573/serc.14227085 ). Annual fluxes across chamber and EC sites averaged 26 ± 53 g CH 4 m −2 year −1 , with a median of 3.9 g CH 4 m −2 year −1 , and only 25% of sites exceeding 18 g CH 4 m −2 year −1 . The highest fluxes were observed at fresh‐oligohaline sites with daily maximum temperature normals (MATmax) above 25.6°C. These were followed by frequently inundated low and mid‐fresh‐oligohaline marshes with MATmax ≤25.6°C, and mesohaline sites with MATmax >19°C. Quantile regressions of paired chamber CH 4 flux and porewater biogeochemistry revealed that the 90th percentile of fluxes fell below 5 ± 3 nmol m −2 s −1 at sulfate concentrations >4.7 ± 0.6 mM, porewater salinity >21 ± 2 psu, or surface water salinity >15 ± 3 psu. Across sites, salinity was the dominant predictor of annual CH 4 fluxes, while within sites, temperature, gross primary productivity (GPP), and tidal height controlled variability at diel and seasonal scales. At the diel scale, GPP preceded temperature in importance for predicting CH 4 flux changes, while the opposite was observed at the seasonal scale. Water levels influenced the timing and pathway of diel CH 4 fluxes, with pulsed releases of stored CH 4 at low to rising tide. This study provides data and methods to improve tidal marsh CH 4 emission estimates, support blue carbon assessments, and refine national and global GHG inventories.

54 ENVIRONMENTAL SCIENCES

Development of Readily Available & Robust High Heat Flux Gardon Gauges

Concentrated solar power (CSP) technologies deliver concentrated solar energy as a heat source to industrial processes, power generation cycles, and chemical cycles. CSP systems require accurate and reliable high flux measurements, and next generation CSP systems will require flux measurement up to 1000 W/cm2. Existing flux measurement devices do not comprehensively meet the flux rating, cycle life, cost, and lead-time needs of stakeholders, necessitating the development of an improved flux sensor. In this study, Sandia National Laboratories (SNL) partnered with Hukseflux Thermal Sensors to develop a low-cost, short lead-time, and robust flux sensor rated to 250 W/cm2. Three prototype circular foil gauge designs were assessed for performance at the National Solar Thermal Test Facility (NSTTF) at SNL. Each gauge design measured flux up to 250 W/cm2 with <5% measurement error. Following baseline error quantification, gauges were exposed to flux above 500 W/cm2 to assess gauge failure mechanisms. Gauges physically survived >500 W/cm2 flux exposure, but measurement error was found to increase after foil coatings reached 400 °C. The results of this study suggest that coating optical properties change at excessive temperatures and that foil coating temperature, rather than heat flux level, dictates the acceptable gauge measurement range.

McLaughlin, Luke (ORCID:0000000303711310)

Quantification of regional net CO 2 flux errors in the Orbiting Carbon Observatory-2 (OCO-2) v10 model intercomparison project (MIP) ensemble using airborne measurements

Inverse model intercomparison projects (MIPs) provide a chance to assess the uncertainties in inversion estimates arising from various sources. However, accurately quantifying ensemble CO 2 flux errors remains challenging and often relies on the ensemble spread. This study proposes a method for quantifying the errors in regional net surface–atmosphere CO 2 flux estimates from models taken from the Orbiting Carbon Observatory-2 (OCO-2) v10 MIP by using independent airborne CO 2 measurements for the period 2015–2017. We first calculate the root mean square error (RMSE) between the ensemble mean of posterior CO 2 concentrations and airborne observations and then isolate the CO 2 concentration errors caused solely by the ensemble mean of posterior net fluxes by subtracting the observation, representation, and transport errors from seven regions. Our analysis reveals that the flux errors projected onto CO 2 space account for 55 %–85 % of the regional average RMSE over the 3 years, ranging from 0.88 to 1.91 ppm. In five regions, the error estimates based on observations exceed those computed from the ensemble spread of posterior fluxes by a factor of 1.33–1.93, implying an underestimation of the actual flux errors, while their magnitudes are comparable in two regions. The adjoint sensitivity analysis identifies that the underestimation of flux errors is prominent where the magnitudes of fossil fuel emissions exceed those of terrestrial-biosphere fluxes by a factor of 3–31 over the 3 years. This suggests the presence of systematic biases in the inversion estimates associated with errors in the prescribed fossil fuel emissions common to all models. Our study emphasizes the value of airborne measurements for quantifying regional errors in ensemble net CO 2 flux estimates.

54 ENVIRONMENTAL SCIENCES

Annual carbon dioxide flux over seasonal sea ice in the Canadian Arctic

Continuous measurements of carbon dioxide (CO 2 ) flux were collected from a 10 m eddy covariance tower in a coastal-marine environment in the Canadian Arctic Archipelago over the course of a 17-month period. The extended length of data collection resulted in a unique dataset that includes measurements from two spring melt and summer seasons and one autumn freeze-up. These field observations were used to verify findings from previous theoretical and laboratory experiments investigating air-sea gas exchange in connection with sea ice. The results corroborated previous findings showing that thick ice cover under winter conditions acts as a barrier to gas exchange. In the spring, CO 2 fluxes were downward (uptake) in both the presence of melt ponds and during ice break-up. However, diurnal cycles were present throughout the early spring melt period, corresponding to the opposing influences of freezing and melting at the ice surface. Fluxes measured during melt periods confirmed previous laboratory tank measurements that showed a gas transfer coefficient of melting ice of 0.4 mol m −2 d −1 atm −1 . Open water CO 2 fluxes showed outgassing in early summer and uptake in mid-to-late summer, tied closely to trends in surface water temperature and its effect on the partial pressure of CO 2 in the water. The autumn period of the field campaign represents the first eddy covariance CO 2 fluxes measured over naturally forming sea ice. Our measurements showed mean upward fluxes (outgassing) of 1.1±1.5 mmol m −2 d −1 associated with the freezing of ice – the same order of magnitude found by previous laboratory tank experiments. However, peak flux periods during ice formation had measured fluxes that were a factor of 3 higher than the tank experiments, suggesting the importance of natural conditions (e.g., wind) on air-ice gas exchange. Conducting an Arctic-wide extrapolation we estimate CO 2 outgassing from the freezing period to be a counterbalance equivalent to 5 to 15 % of the magnitude of the estimated Arctic CO 2 sink. Overall, there was no evidence of dramatically enhanced gas exchange in marginal ice conditions as proposed by previous studies. Although the different seasons showed active CO 2 exchange, there was a balance between upward and downward fluxes at this specific location, resulting in a small net CO 2 uptake over the annual cycle of −0.3 g C m −2 .

54 ENVIRONMENTAL SCIENCES

Role of microstructure on flux expulsion of superconducting radio frequency cavities

The trapped residual magnetic flux during the cool-down due to the incomplete Meissner state is a significant source of radio frequency losses in superconducting radio frequency cavities. Here, in this study, we clearly correlate the niobium microstructure in elliptical cavity geometry and flux expulsion behavior. In particular, a traditionally fabricated Nb cavity half-cell from an annealed poly-crystalline Nb sheet after an 800 °C heat treatment leads to a bi-modal microstructure that ties in with flux trapping and inefficient flux expulsion. This non-uniform microstructure is related to varying strain profiles along the cavity shape. A novel approach to prevent this non-uniform microstructure is presented by fabricating a 1.3 GHz single cell Nb cavity with a cold-worked sheet and subsequent heat treatment leading to better flux expulsion after 800 °C/3 h. Microstructural evolution by electron backscattered diffraction-orientation imaging microscopy on cavity cutouts, and flux pinning behavior by dc-magnetization on coupon samples confirms a reduction in flux pinning centers with increased heat treatment temperature. The heat treatment temperature-dependent mechanical properties and thermal conductivity are reported. The significant impact of cold work in this study demonstrates clear evidence for the importance of the microstructure required for high-performance superconducting cavities with reduced losses caused by magnetic flux trapping.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND

Development and validation of non-axisymmetric heat flux simulations with 3D fields using the HEAT code

A new comprehensive module to simulate heat fluxes from three-dimensional (3D) magnetic fields has been implemented in the HEAT code. Especially compact tokamaks like SPARC require tools to predict and manage large heat fluxes. Existing release versions of HEAT can only simulate axisymmetric heat flux on 3D plasma facing components. The new module uses an M3D-C1 perturbed equilibrium and the MAFOT code to trace field lines of the perturbed 3D magnetic field. Heat flux is then assigned to the resulting footprints via a 3D layer model. The model distinguishes between the scrape-off layer, the magnetic lobes and the private flux region, and employs only 0D parameters like the layer width, diffusive spread and the last closed flux surface position in the perturbed edge to generate a heat flux profile. The magnitude is normalized to the total input power. Resulting heat flux simulations are compared and validated against infrared measurements in the DIII-D tokamak with applied 3D fields; good agreement is found for several cases. The new module can now be applied to the SPARC tokamak; a preliminary result for applied rotating 3D fields is shown.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Meteoric 10Be Flux Calibration Data for the East River Watershed, Colorado, USA

This data package contains tabular and geospatial data used to quantify and model meteoric beryllium-10 fluxes in the East River watershed, Colorado, USA. The tabular component includes calibration-site data from five glacial moraine sites and includes environmental variables used to evaluate spatial controls on meteoric 10Be delivery, including elevation, mean annual precipitation (MAP), mean snow depth, and mean snow water equivalent (SWE). These site-level data were used to compare observed fluxes with environmental gradients across the watershed and to evaluate the effects of erosion correction on flux estimates. The package also includes supporting slope and curvature values used to assess topographic inputs to the erosion analysis. A second component of the data package contains updated manuscript tables and regression outputs used to summarize the relationships between meteoric 10Be flux and environmental predictors. These tables include meteoric 10Be sample information and AMS results, site-level environmental values, site-level meteoric 10Be inventory and flux values, watershed-averaged predicted fluxes, soil bulk density measurements, fine-fraction values, soil pH measurements, and regression statistics including slope, intercept, coefficient of determination, and p-value. The regression products include both standard linear regressions and regressions in which the intercept is constrained to pass through zero, and they support the analyses presented in the companion manuscript. Together, these tabular files provide the numerical basis for the manuscript tables and the regression-based interpretation of meteoric 10Be flux variability in a snow-dominated mountain watershed. The geospatial component of the package consists of GeoTIFF raster files used to generate the map products presented in Figures 2 and 6 of the companion manuscript. These rasters represent watershed-scale spatial layers for environmental variables and regression-based predictions of meteoric 10Be flux. This dataset contains comma-separated values files (.csv), Microsoft Excel files (.xlsx), GeoTIFF raster files (.tif), and upporting metadata files, including CSV data dictionaries and readme text files (.csv, .txt). The tabular files can be opened with standard spreadsheet software, and the raster files can be viewed and analyzed in GIS software such as ArcGIS Pro or QGIS. Together, these files document the numerical and spatial datasets used to calibrate and predict meteoric 10Be delivery in the East River watershed.

East River

An intercomparison of wall fluxes in a turbulent thermal convection chamber: Direct numerical simulations and wall-modeled large-eddy simulations enhanced by machine learning

Thermal convection in a closed chamber is driven by a warm bottom, a cold top, and side walls at various temperatures. Although wall fluxes are the source of convection energy, accurately modeling these fluxes (i.e., the wall model) is challenging. In large-eddy simulations (LESs), many wall models are traditionally derived from the canonical boundary layer, which may be unsuitable for thermal convection bounded by both horizontal and vertical walls. This study conducts a model intercomparison of dry convection in a cubic-meter chamber using three direct numerical simulations (DNSs) and four LESs with different wall models. The LESs employ traditional wall models, a new wall model employing physics-aware neural networks, and a refined grid near the walls. The experiment involves four cases with varying sidewall temperatures. Our results show that LESs capture the main flow features and the trends of mean fluxes. The physics-aware neural networks and refined wall grids can improve the temporally averaged local fluxes when the large-scale circulation has a preferred direction. Even without the local improvement of wall fluxes, the LES flow quantities (temperature and velocities) can still largely match those in DNSs, provided the mean flux largely matches the DNSs. Additionally, DNSs reveal that a variation in corner treatments has minimal impacts on the flow quantities away from corners. Finally, LESs underestimate the mean fluxes of the entire wall due to their inability to resolve corner regions, but their mean flux away from the corner can better match DNS.

54 ENVIRONMENTAL SCIENCES

The Atlantic Meridional Overturning Circulation’s Response to CO2 Increase: Assessing the Roles of Surface Flux and Oceanic Advection Feedbacks

Abstract The Atlantic meridional overturning circulation (AMOC) is projected to slow down in climate models due to greenhouse gas emissions. However, the physical mechanisms determining the rate of the projected AMOC slowdown remain unclear. Accordingly, this study isolates the roles of oceanic advection and surface flux feedbacks that might accelerate or decelerate the AMOC’s weakening using carbon dioxide (CO 2 ) quadrupling simulations in the CESM1.2 model. Surface flux feedbacks are isolated in partially coupled experiments in which either all surface flux components or the momentum flux responses to AMOC’s weakening that might provide feedback are suppressed, while a tracer decomposition of ocean density anomalies isolates the advection feedbacks. Comparing the ocean density components in the experiments shows that the AMOC’s response is initially determined by CO 2 -induced anomalous surface heat fluxes, and afterward, feedbacks determine its response. In the fully coupled case, surface heat flux feedback strongly promotes AMOC slowdown and causes its near shutdown, while a weaker but active AMOC is maintained when the surface flux feedback is inhibited in the partially coupled case. The positive surface heat flux feedback works by canceling out the negative oceanic heat advection feedback on deep-water formation in the subpolar North Atlantic (SPNA). With the heat advection feedback thus reduced, the positive salinity advection feedback becomes the dominant contributor to SPNA density changes and deep-water formation. In the partially coupled case, negative ocean heat advection feedback and the CO 2 -induced subtropical Atlantic saline anomalies imported into the SPNA play a stabilizing role. The results highlight the importance of SPNA salinity gradients and gyre circulation strength in determining the AMOC’s response rate or recovery.

54 ENVIRONMENTAL SCIENCES

On the predictability of turbulent fluxes from land: PLUMBER2 MIP experimental description and preliminary results

Accurate representation of the turbulent exchange of carbon, water, and heat between the land surface and the atmosphere is critical for modelling global energy, water, and carbon cycles in both future climate projections and weather forecasts. Evaluation of models' ability to do this is performed in a wide range of simulation environments, often without explicit consideration of the degree of observational constraint or uncertainty and typically without quantification of benchmark performance expectations. We describe a Model Intercomparison Project (MIP) that attempts to resolve these shortcomings, comparing the surface turbulent heat flux predictions of around 20 different land models provided with in situ meteorological forcing evaluated with measured surface fluxes using quality-controlled data from 170 eddy-covariance-based flux tower sites. Predictions from seven out-of-sample empirical models are used to quantify the information available to land models in their forcing data and so the potential for land model performance improvement. Sites with unusual behaviour, complicated processes, poor data quality, or uncommon flux magnitude are more difficult to predict for both mechanistic and empirical models, providing a means of fairer assessment of land model performance. When examining observational uncertainty, model performance does not appear to improve in low-turbulence periods or with energy-balance-corrected flux tower data, and indeed some results raise questions about whether the energy balance correction process itself is appropriate. In all cases the results are broadly consistent, with simple out-of-sample empirical models, including linear regression, comfortably outperforming mechanistic land models. In all but two cases, latent heat flux and net ecosystem exchange of CO 2 are better predicted by land models than sensible heat flux, despite it seeming to have fewer physical controlling processes. Land models that are implemented in Earth system models also appear to perform notably better than stand-alone ecosystem (including demographic) models, at least in terms of the fluxes examined here. The approach we outline enables isolation of the locations and conditions under which model developers can know that a land model can improve, allowing information pathways and discrete parameterisations in models to be identified and targeted for future model development.

54 ENVIRONMENTAL SCIENCES

Impact of error fields and error field correction on heat fluxes in SPARC

Using a single toroidal array of coils to reduce the m,n = 2,1 resonant error field (EF) produced by the misalignment of the axisymmetric coils in SPARC can result in the enhancement of the local divertor heat fluxes. Managing high divertor heat fluxes (q ∥ $\simeq$ 10 GW m -2 ) poses a challenge for compact tokamak devices such as SPARC. The presence of non-axisymmetric magnetic field perturbations adds complexity to the problem by generating intricate 3D edge magnetic topologies that alter the heat flux distributions on the target plates. The aim of this work is to investigate the impact of the EF correction (EFC) on the heat fluxes at the divertor plates in SPARC. The MHD code M3DC1 has been used to simulate the 3D magnetic perturbations generated by the shift and tilt of several axisymmetric coils within specified tolerances, as well as from the array of EFC coils located at the midplane. Using a heuristic model that extends the concept of an axisymmetric heat flux layer to 3D plasmas, the resultant heat flux distributions is derived from magnetic footprints calculated with the MAFOT code. The results show that the EFC could either decrease or further enhance the local heat flux when used to correct the m,n = 2,1 resonant EF to enhance the core plasma performance.

3D fields

Permeate fluxes from desalination of brines and produced waters: A reactive transport modeling study

The increasing interest in the use of membrane systems to desalinate inland brackish water, agricultural drainage, and industrially produced wastewater demands improved means of predicting desalination system performance under variable feedwater compositions. The interaction among water flow, solute transport, and chemical composition in these systems impacts permeate flux evolution. Here, an established multicomponent reactive transport simulator that accounts for these coupled processes is applied to compute osmotic pressure and permeate fluxes in reverse osmosis (RO) systems. The model is first validated by predicting permeate fluxes for a set of benchtop crossflow experiments subject to a range of feed flow rates and compositions, under fouling and non-fouling conditions. Results compare favorably with measured data that show that solutions with similar total dissolved solids concentrations but different compositions result in different permeate fluxes. The model is then applied to predict permeate fluxes from the desalination of produced waters using a commercial spiral wound RO module. For NaCl-dominant brines, at total dissolved salt concentrations (TDS) below about 70 g/L, permeate fluxes are inversely proportional to water mole fraction as the latter is a reasonable approximation of water activity (i.e. ideal mixing). In the case of Ca–Cl-, Na–CO3- and Na–SO4-dominant brines below about 70 g/L TDS, this relationship does not hold as well and tends to overpredict osmotic pressure and thus underpredict permeate fluxes. However, the opposite becomes true at higher TDS values for typical produced waters. The scaling potential of these waters is also computed by allowing the precipitation of minerals above their saturation limit on the RO membrane. This work demonstrates how reactive transport models developed for the analysis of waters from geological systems can be extended to improve process design, optimization, and control in desalination systems from produced waters and beyond.

Molins, Sergi

Inferring the scrape-off layer heat flux width in a divertor with a low degree of axisymmetry

Plasma facing components (PFCs) in the next generation of tokamak devices will operate in challenging environments, with heat loads predicted to exceed 10 MWm -2 . The magnitude of these heat loads is set by the width of the channel, the ‘scrape-off layer’ (SOL), into which heat is exhausted, and can be characterised by an e-folding length scale for the decay of heat flux across the channel. It is expected this channel will narrow as tokamaks move towards reactor relevant conditions. Understanding the processes involved in setting the SOL heat flux width is imperative to be able to predict the heat loads PFCs must handle in future devices. Measurements of the SOL width are performed on the high-field spherical tokamak, ST40, using a newly commissioned infrared thermography system. With its high on-axis toroidal magnetic field (≥1.5 T) ST40 is uniquely positioned to investigate the influence of toroidal field on the heat flux width in spherical tokamaks, whilst also extending measurements of the SOL width in spherical tokamaks to increased poloidal field (≥0.3 T). Due to the divertor on ST40 having a low degree of axisymmetry, it is necessary for a set of radial measurements of the heat flux to be taken across the divertor, made possible using an automated toolchain that fully incorporates its 3D geometry. These radial profiles are combined with the magnetic geometry of the plasma to infer the width of the SOL, with both Eich and double exponential profiles of heat flux observed. A reduction in the heat flux is observed toroidally across part of the divertor, along with increased heat loads observed locally around the edges of the tiles. Future work in characterising the impact of tile misalignment and uncertainties in the reconstructed divertor magnetic geometry is required in order to further understand the observed heat flux patterns, as are additional investigations into the role potentially being played by an inhomogeneous sheath electric field.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

fluxfinder: An R Package for Reproducible Calculation and Initial Processing of Greenhouse Gas Fluxes From Static Chamber Measurements

Fluxes of greenhouse gases are a critical component of the earth's natural climate, but anthropogenic emissions have created an imbalance and resulted in global climate change. Quantifying the emission of these gases is vital to our understanding of their sources and sinks, both natural and anthropogenic. The static chamber method, in which a system of interest is enclosed, and gas concentrations are measured over time, is widely used to estimate fluxes of greenhouse gases. With the development of instruments such as infrared gas analyzers (IRGAs) supporting high-frequency concentration data, there is a growing need for open-source workflows to calculate fluxes. Here we present fluxfinder, an R package designed to support reproducible calculations and processing of greenhouse gas fluxes measured with the static chamber method. The package includes raw data file parsing from widely used IRGAs, metadata matching, unit conversion, flux estimations, and initial quality assurance/quality control (QA/QC). Diagnostic graphical plots provide a transparent way to differentiate between measurement issues and nonlinear behavior. The package is also designed to be easily integrated with the gasfluxes package for further fitting of nonlinear concentration-time models, allowing alternative or additional flux QA/QC. The fluxfinder package offers a flexible workflow that is easily adaptable to promote open and reproducible greenhouse gas flux estimations.

Wilson, Stephanie J.