Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fenestration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

31 records · Page 2

Assessing Methodologies for Detecting Water Intrusion in Wall Systems: Phase 2

Studies by the University of Florida, the Environmental Protection Agency (EPA) and the U.S. Department of Housing (HUD) have revealed that there is a substantial fraction of commercial and residential buildings that have been exposed to moisture resulting in damage or durability problems. Water intrusion into building envelope components leads to a variety of undesirable conditions such as mold, wood rot, corrosion, and aesthetic damage. Tests methods that are presently used to evaluate the amount of water intrusion into a building envelope component are usually qualitative in nature. For example, ASTM E 331, Standard Test Method for Water Penetration of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference requires that you “observe and record points of water leakage, if any.” This test was originally developed to assess the performance of fenestration products but is commonly adapted to evaluate other enclosure assemblies. However, when it is typically used for walls, this procedure is limited to recognizing if the moisture is visually observable from the backside side of the sheathing. It does not address moisture that is absorbed in the layers of the building envelope component, which could impact the durability of the assembly. Clearly a quantitative means of determining water penetration would improve the quality of this type of test and assist with better understanding the resultant impact on enclosure assemblies. In 2018-20, Oak Ridge National Laboratory, in conjunction with the Air Barrier Association of America, initiated a research project to address this issue. The purpose of that study was to evaluate nine different methods of detecting moisture intrusion through a wall assembly. air and water barrier. The wall assemblies included metal frame construction faced with gypsum sheathing and both self-adhered and fluid applied air and water barriers (AWB) were evaluated for this exercise. This project did not test the efficacy of the different AWBs, rather, fasteners were purposely installed in various ways to foster water penetration and activate the different methods of detection. Each detection method was evaluated for five features that included simplicity of use, cost of implementation, whether the method was quantitative or subjective, accuracy, and applicability. A scale of green/yellow/red was used to assess each feature where green was acceptable, yellow was borderline, and red was not to be pursued at this time. This report covers additional research that has been undertaken to extend the activities initiated in this earlier project with refinements for specific detection methods and considerations for expansion related to field versus laboratory testing standards.

42 ENGINEERING↗

Improved Manufacturability and Throughput of Ultra- Transparent, Super-Insulating Aerogels

AeroShield Materials produces a novel silica aerogel material with exemplary thermal performance and unprecedented optical clarity, offering the potential for super-insulating fenestration and insulated glass to reduce thermal losses in the built environment by billions of dollars every year. One of the most significant challenges facing AeroShield today is the total amount of time that is required to produce large monolithic aerogel samples. This overall process can require as much as 144 hours total, which can significantly hinder scale-up to an economically viable product. The purpose of this Phase 1 research was to continue development of our novel aerogel manufacturing process to reduce material processing time by up to 10x, greatly improving product throughput and reducing cost. AeroShield’s manufacturing process can be divided into 4 major stages, each with their own distinct set of parameters and time requirements. Under this Phase 1 award, AeroShield was able to identify and optimize a number of these parameters, including molding materials, solvent rinse conditions, critical point drying time, and annealing conditions. AeroShield also performed thorough analyses on how these optimized parameters affected important final characteristics of the gels, including optical clarity, thermal conductivity, and dimensional stability. This campaign culminated in the production of laboratory scale aerogel samples using significantly lower process times of both 36 and 18 total hours, which represent Phase 1 Target and Stretch goals. In order to achieve widespread market adoption, monolithic sheets of the aerogel material must be made to industry-standard sizes (8’ x 12’) at a cost that provides 5-7 year or less breakeven energy savings for consumers (<$2 sq/ft). The work performed under this Phase 1 award shows that time and materials required to make aerogel samples, which make up a significant portion of their overall cost, can be greatly reduced without sacrificing quality. AeroShield plans to use these optimized processes to produce larger, product-relevant sized aerogels in order to achieve target final material costs.

Wilke, Kyle↗

Energy and Comfort Impacts of High Performance Facades in Office Buildings

Building facades have a major effect on energy use, occupant comfort, and well-being. Yet adoption of high-performance facades is often slowed by limited data and unclear cost benefits. To address this gap, Oak Ridge National Laboratory, in collaboration with the Facade Tectonics Institute, conducted whole-building energy simulations to evaluate fenestration technologies for small and medium office buildings across three weather locations: hot (Tampa, Florida, weather zone 2A), mixed (New York, New York, weather zone 4A), and cold (Rochester, Minnesota, weather zone 6A). The simulations included parametric variations in window-to-wall ratio (30%–70%), U-values (0.1–1 Btu/h∙ft 2 ∙°F), solar heat gain coefficients (0.2–0.8), and solar control strategies and devices (e.g., interior shades and switchable glazing). Performance metrics included annual cooling, heating, and total heating, ventilation and air-conditioning (HVAC) energy use intensity, as well as nonenergy factors such as useful daylight illuminance, glare frequency, and thermal comfort during typical office hours (8 a.m.–6 p.m.). Results indicate that cooling energy consumption is most sensitive to solar heat gain coefficient (SHGC) in hot weather, whereas heating energy consumption is strongly influenced by U-value in cold weather. Total HVAC reflects these trade-offs, showing up to 60% difference for a window in total HVAC energy use intensity between different combinations of U-value and SHGC. Daylight dimming generally reduces cooling loads but can increase heating demands in colder locations. Interior solar shades improve useful daylight and reduce discomfort glare, whereas switchable glazing delivers the largest cooling reductions in hot weather but may increase heating loads in winter by limiting passive solar gains. Thermal comfort improves with lower window-to-wall ratios and lower SHGC in hot locations and with lower U-values in cold locations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of Energy Efficiency Performance of Heated Windows

Fenestration systems are widely used across the world. There is expansive research on window configurations, frames, and glazing technology, but not enough research has been published on reducing window heat loss through heat application to a pane. The presented study attempted to evaluate the performance of heated windows by developing an experimental setup to test a window at various temperatures by varying the power input to the window. Heated double pane window was installed in an insulated box. A temperature gradient was developed across the window by cooling one side of the window using gel-based ice packs. The other face of the window was heated by enabling power at different wattages through the window. The temperature of the inside and outside panes, current and voltage input, and temperature of the room and box were recorded. The data was used to calculate the apparent effective resistance of the window when not being heated vs. when being heated. The study concluded that, when window temperature was maintained close to the room temperature, the heated double pane window is effective in reducing heat loss by as much as 50% as compared to a non-heated double pane window. When temperature of the window was much higher than the room temperature, the heat loss through the window increased beyond that of a non-heated window. The issues encountered during the current stages of experiments are noted, and recommendations are provided for future studies.

42 ENGINEERING↗

Towards Energy-Positive Buildings through a Quality-Matched Energy Flow Strategy

Current strategies for net-zero buildings favor envelopes with minimized aperture ratios and limiting of solar gains through reduced glazing transmittance and emissivity. This load-reduction approach precludes strategies that maximize on-site collection of solar energy, which could increase opportunities for net-zero electricity projects. To better leverage solar resources, a whole-building strategy is proposed, referred to as “Quality-Matched Energy Flows” (or Q-MEF): capturing, transforming, buffering, and transferring irradiance on a building’s envelope—and energy derived from it—into distributed end-uses. A mid-scale commercial building was modeled in three climates with a novel Building-Integrated, Transparent, Concentrating Photovoltaic and Thermal fenestration technology (BITCoPT), thermal storage and circulation at three temperature ranges, adsorption chillers, and auxiliary heat pumps. BITCoPT generated electricity and collected thermal energy at high efficiencies while transmitting diffuse light and mitigating excess gains and illuminance. The balance of systems satisfied cooling and heating demands. Relative to baselines with similar glazing ratios, net electricity use decreased 71% in a continental climate and 100% or more in hot-arid and subtropical-moderate climates. Total EUI decreased 35%, 83%, and 52%, and peak purchased electrical demands decreased up to 6%, 32%, and 20%, respectively (with no provisions for on-site electrical storage). Decreases in utility services costs were also noted. These results suggest that with further development of electrification the Q-MEF strategy could contribute to energy-positive behavior for projects with similar typology and climate profiles.

54 ENVIRONMENTAL SCIENCES↗

The Structure of the Mammalian Area Postrema

The area postrema in mammals other than rodents and lagomorphs is a bilateral mound of gelatinous-appearing tissue that protrudes into the caudal fourth ventricle on either side of the obex. In rodents and lagomorphs it is a single midline structure at the apex of the calamus scriptorius. The vasculature is derived mainly from the posterior inferior cerebellar arteries and consists mainly of sinusoidal capillaries. It appears to constitute a portal system, at least in the rat. Many of the capillaries are fenestrated, and many large perivascular spaces with both vascular and parenchymal basal laminae are present. The cell population is composed of flattened ependymal cells exhibiting microvilli, and of small neurons, normal astrocytes, glialoid cells, and a very few oligodendroglia. Mast cells are occasionally present. The glialoid cells appear to be the predominant cell type and exhibit great numbers of vascular podia. Axodendritic synapses are numerous and axosomatic synapses are occasionally seen in the parenchyma. Synaptic vesicles are mainly of the clear-cored type but large dense-cored vesicles are commonly observed in some axon terminals.

Brizzee, K. R.↗

Localized infusion of IGF-I results in skeletal muscle hypertrophy in rats

Insulin-like growth factor I (IGF-I) peptide levels have been shown to increase in overloaded skeletal muscles (G. R. Adams and F. Haddad. J. Appl. Physiol. 81: 2509-2516, 1996). In that study, the increase in IGF-I was found to precede measurable increases in muscle protein and was correlated with an increase in muscle DNA content. The present study was undertaken to test the hypothesis that direct IGF-I infusion would result in an increase in muscle DNA as well as in various measurements of muscle size. Either 0.9% saline or nonsystemic doses of IGF-I were infused directly into a non-weight-bearing muscle of rats, the tibialis anterior (TA), via a fenestrated catheter attached to a subcutaneous miniosmotic pump. Saline infusion had no effect on the mass, protein content, or DNA content of TA muscles. Local IGF-I infusion had no effect on body or heart weight. The absolute weight of the infused TA muscles was approximately 9% greater (P < 0.05) than that of the contralateral TA muscles. IGF-I infusion resulted in significant increases in the total protein and DNA content of TA muscles (P < 0.05). As a result of these coordinated changes, the DNA-to-protein ratio of the hypertrophied TA was similar to that of the contralateral muscles. These results suggest that IGF-I may be acting to directly stimulate processes such as protein synthesis and satellite cell proliferation, which result in skeletal muscle hypertrophy.

Non-NASA Center↗

A Python Library for Radiance Matrix-based Simulation Control and EnergyPlus Integration

Radiance matrix-based methods enable efficient parametric simulations, allowing users to vary sky conditions, fenestration systems, and other model parameters at a minimal cost to computation. However, the steep learning curve and complex workflow hinder the widespread adoption of matrix-based methods. The frads Python library with a series of command-line tools was developed to automate the entire matrix-based simulation process, lowering entry barriers and reducing human error. Co-simulation between EnergyPlus and Radiance was also enabled using the Python library from EnergyPlus. Key Innovations • Command-line based automation of Radiance matrix-based simulation methods • Python library facilitates broader adoption of Radiance matrix-based simulation methods • Radiance EnergyPlus run-time integration enabling the modeling of advanced control systems Practical Implications The frads library, with associated command-line tools, provides practitioners with the capability to easily adopt and use Radiance matrix-based simulation methods for various daylighting, solar control, and energy-related evaluations. Frads' current form is designed for 1) users familiar with a command-line interface and 2) software developers to integrate the matrix-based methods into existing software packages.

Wang, Taoning↗

Long term performance of vacuum insulation panels integrated into building components

Vacuum insulation panels provide much greater resistance to heat transfer than conventional insulation materials, making them ideal for building applications, especially where space is a constraint. Of particular interest is energy retrofits where high insulation values are required with very little or no modifications to existing building envelope elements such as fenestrations and service penetrations. To facilitate the use of vacuum insulation panels (VIPs) in residential and commercial construction, this study investigates the performance of VIPs integrated into polyisocyanurate foam board and vinyl siding after several years of service. Vacuum insulation panels integrated with polyisocyanurate boards were studied in mixed humid and cold climates. The integration of VIPs with vinyl siding was investigated in a mixed humid climate. Periods of service were between two and five years. In all cases, the integrated building components outperformed conventional materials by almost 40 percent during heating and cooling periods. However, the percent reduction in heat gains and losses of the integrated building components decreased with time at a rate between approximately 4% and 10% per year during the service period. In some cases, the rate seems to converge to a steady -state value. Measurements are ongoing to determine if a steady-state value is attained or the panel's insulation value continues to decrease with time. This study is critical in addressing the service life and durability of the building envelope with VIP integrated building components. The effect of these changes will be reviewed in the context of an exterior retrofit.

Aldykiewicz Jr, Antonio↗

Online Calculator to Evaluate the Impact of Airtightness on Residential Building Energy Consumption and Moisture Transfer

Energy consumption in residential buildings is primarily driven by space conditioning applications. Space heating and cooling, on average, consume approximately 50% of the energy in the residential buildings in the U.S. The primary energy use due to infiltration is more than 2.8 Quads, which is 29% of primary energy consumption attributable to fenestration and building envelope components in residential buildings in US in 2010. There are advanced air barrier technologies and construction practices to reduce air leakage in buildings, which are currently available in the market. However, the lack of adequate information on their impact on energy consumption and the durability of buildings has caused the slow adoption of these technologies and methods. In the past, the authors developed an online calculator that estimates the potential energy and cost savings in major U.S., Canadian and Chinese cities from improvement in airtightness in commercial buildings. In 2018–2019, the calculator was expanded to add moisture transfer calculations, given that air leakage through the building envelope can have a significant impact on moisture transfer. The calculator is again being expanded by adding residential and additional commercial building data. In this paper, we present the impact of airtightness in residential buildings on energy consumption and moisture transfer. The study includes the analysis of airtightness in 52 major cities in the U.S. and five cities in Canada on a residential building that includes a crawlspace and has a gas furnace.

Kunwar, Niraj↗

Potential annual daylighting performance of a high-efficiency daylight redirecting slat system

While the primary role of window attachments is often to moderate glare and solar heat gains, they are also able to provide additional daylight to interior spaces. For this purpose, a variety of daylight-redirecting window systems have been developed over the past 150 years. Fixed reflective systems (slats/light shelves) or prismatic systems that rely on total internal reflection work well under specific solar conditions, but generally sacrifice performance over a much wider range of incident solar angles and sky conditions. Dynamic systems - typically reflective slats - are more responsive to sun angles but have not been able to achieve optimal performance for glare and daylight redirection efficiency. A previous investigation into an adjustable, reflective blind concept first conceived of in the late 1970s showed promise but was not reduced to practice due to lack of adequate simulation and analysis tools. In this paper, this concept is further developed and its energy and visual comfort performance evaluated for four mid-latitude, temperate climates using ray-tracing simulation techniques. Overall, results indicate significant potential lighting energy savings when compared with conventional automated reflective blinds (2.1–4.9 kWh/(m 2 ·a), or 14%–42%, depending on climate and orientation) or, especially, manually-operated matte white venetian blinds (1.4–7.9 kWh/(m 2 ·a), or 9%–54%, depending on climate and orientation), while maintaining acceptable or better visual comfort conditions throughout the interior space.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multi-cell, triple pane, vacuum insulated glazing

A novel Triple Pane Vacuum Insulated Glazing (TPVIG) architecture consisting of three panes of glass separated by two offset grids is described. The grids are made of frit-coated fibers fused with the glass panes in a vacuum to create many independent hermetic cells. Unlike traditional VIGs, which are separated by support pillars, these cells significantly increase the redundancy in sealing, and the additional bonds formed by the grid lines reduce the stresses on the edge bonds thereby increasing VIG reliability. A numerical thermal analysis was conducted to determine the thermal performance of the VIG and suggested U-values below 0.5 W/m 2 -K (greater than R=11.4 hr-ft 2 -°F/Btu) can be obtained. A prototype of the VIG unit consisting of three glass panes (5.7 mm, 1.1 mm and 5.7 mm thick with low-e coating on two surfaces) was fabricated and tested for thermal performance using the hot box method. The experimental center of glass U-value for the VIG was found to be 0.42 W/m 2 K (R=13.2 hr-ft 2 -°F/Btu). Furthermore, this U-value is about four times lower than a typical Argon filled double pane window.

14 SOLAR ENERGY↗