Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fenestration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Commercial Building Fenestration Market Study

This study characterizes and assesses the U.S. commercial fenestration market. It analyzes a groundbreaking amount of data that will ultimately support an estimate of national savings potential of energy efficient fenestration products in commercial applications to demonstrate the benefits of efficient façade and fenestration systems. This study provides data and analysis on: commercial fenestration market and fenestration selection process, installed commercial fenestration stock across the U.S. and fenestration sales estimates, and current commercial building fenestration codes and market trends of installation to or above code.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Advanced Fenestration Controller (AFC) v1.0

The Advanced Fenestration Controller is the result of 5+ years of R&D to develop an advanced control system for Dynamic Facades (e.g., automated shades, blinds, etc.), electric lighting, and HVAC system in buildings. It can dynamically control those technologies to reduce electricity cost while increasing comfort. The work in FY22 focused on open-sourcing our development, per agreement with DOE.

Gehbauer, Christoph↗

Durability Evaluation of Advanced Fenestration Technologies

In the U.S., more than 40% of primary energy and 70% of electricity is consumed in residential and commercial buildings, resulting in annual energy costs of more than $430 billion. Approximately 35% of this consumption can be attributed to losses through the building envelope, of which windows are currently the weakest link. Multiple technologies are under development to improve this performance. This includes dynamic and photovoltaic glazing as well as emerging highly insulating technologies including vacuum insulating glass (VIG), aerogels and thin-glass based multi-pane configurations. While windows are specified based on expected performance as installed, the energy savings realized by high performance windows are delivered over time. This makes it critical to understand and maximize the durability of high-performance windows to ensure those projected energy savings are delivered. Present methods for evaluating durability are based on existing technologies. These methods may not apply or be adequate for newer emerging technologies which often present novel failure mechanisms that need to be understood and evaluated differently. In this presentation, we will discuss our efforts to define appropriate methods to improve the evaluation of many existing technologies as well as evaluate the durability of emerging window technologies. This work results from the combination of an extensive review of various international standards as well as existing scientific literature. In addition, input was gathered from multiple industry stakeholders regarding present practice as well as feedback on proposed improvements to existing methods. Here we will share these findings and present proposed improvements to developing and existing durability evaluation protocols.

building envelope↗

Experimental demonstration and performance evaluation of a complex fenestration system for daylighting and thermal harvesting

Two significant design strategies for mitigating building energy consumption are daylight redirection and solar energy harvesting. Effective daylighting implementation enhances the amount of useful natural light within a space and offsets the need for electric lighting. Solar energy harvesting systems can mitigate energy costs from mechanical systems by managing incoming thermal loads or capturing solar energy that can be used to supplement thermal systems in the building. While there are many available façade-based technologies that can perform daylighting or solar thermal energy harvesting, there remains a limitation in available systems that can perform both of them simultaneously. This paper, describes the design and experimental demonstration of a Liquid Filled Prismatic Louver (LFPL) system, which combines both energy-saving strategies. The LFPL system was installed in a south-facing room in New York City and evaluated for indoor daylight penetration and potential for thermal energy harvesting. Daylight redirection is achieved through the prismatic louver geometry and proper orientation, whereas thermal energy harvesting is achieved through IR absorption from the liquid (e.g., water) within the prisms. Daylighting performance was evaluated by illuminance measurements at key locations within the space, whereas thermal harvesting performance was evaluated through temperature measurements and thermal imaging analysis. We show that the LFPL system, with all prismatic elements oriented at the same angle, achieve a 2-fold and 8-fold enhancement in daylight redirection to the ceiling, for prism orientations of 10° and 20°, respectively. We also demonstrate the system’s capability to adjust to specific lighting needs, within the space, through the dynamic individual orientation of prismatic elements; thus, achieving a concentrated ceiling illuminance enhancement of ~100 times and ~200 times at 2.5 and 4.3 m away from the window sill, providing workplane illuminance enhancement of 6 and 2 times more than in the case of the control room with regular windows. Furthermore, we illustrate a reduction of potential heating loads at locations close to the window from the combination of infrared absorption in the water volume and the redirection of the incoming solar radiation, leading to a reduction of the workplane temperature by an average of 7–10 °C.

14 SOLAR ENERGY↗

Operating Hardware Impact on the Heat Transfer Properties of Windows

Despite significant advancements in fenestration technology in the last two decades, the thermal transmittance of fenestration products is still significantly higher than that of walls. This corresponds to 60% of the total energy loss of a modern building envelope through the windows. Hence, further development and improvements of fenestration products are necessary. Increasingly stringent codes and standards for fenestration stimulate industry to work on improved solutions. Thus, it is crucial that assessment techniques are able to account for innovations accurately. The thermal effects of non-continuous hardware in window frames are currently ignored by international rating procedures. A preliminary investigation conducted by our team showed significant performance degradation in two of the three out-opening casement profiles caused by the presence of operating hardware. Frames with the structure made of vinyl and fiberglass consist of many air cavities that are penetrated by operating hardware made of highly conductive materials. In these frames, in order to have an accurate assessment, it may be required to employ three-dimensional modeling due to the convective nature of heat transfer within the cavities. However, in this study, we demonstrate that the three-dimensional (3D) effects of non-continuous hardware can be approximated accurately with simpler two-dimensional (2D) simulations. We then develop a simplified model based on weighted average capable of replacing the time- and computation-intensive 3D simulations with 2D simulations and validate it against market available frames and their corresponding hardware. Validation results show that our approximation technique results in discrepancies lower than 0.05 W/(m2K), or 3% of the total thermal transmittance. Thus, we conclude that simplified 2D simulation models may be used for predicting hardware impact in window frames with reasonable accuracy. As windows and glazing structures are becoming ever better thermally insulated, it is becoming even more important to be able to model the impact of the operating hardware on the total thermal performance in order to design the best windows possible and not let the operating hardware ruin an otherwise well-proven design, which is hence addressed in this study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Identification and quantitation of morphological cell types in electrophoretically separated human embryonic kidney cell cultures

Four major cell types were identified by phase microscopy in early passage human embryonic kidney cell cultures. They are small and large epithelioid, domed, and fenestrated cells. Fibroblasts are also present in some explants. The percent of each cell type changes with passage number as any given culture grows. As a general rule, the fraction of small epithelioid cells increases, while the fraction of fenestrated cells, always small, decreases further. When fibroblasts are present, they always increase in percentage of the total cell population. Electrophoretic separation of early passage cells showed that the domed cells have the highest electrophoretic mobility, fibroblasts have an intermediate high mobility, small epithelioid cells have a low mobility, broadly distributed, and fenestrated cells have the lowest mobility. All cell types were broadly distributed among electrophoretic subfractions, which were never pure but only enriched with respect to a given cell type.

Williams, K. B.↗

BSDF Data generation for daylight applications: A call for international standardization

Standardized methods for generating angle-dependent, bidirectional, solar-optical properties for complex fenestration systems do not exist, which means that energy and daylight evaluations in building performance simulations often suffer from major inaccuracies. This position paper provides an overview of state-of-the-art data-driven methods for characterizing light scattering properties of fenestration materials and blind systems (e.g. fabrics, metal slats, patterned glazing), validation via laboratory, simulation and field tests, and salient issues in support of standardization of such methods via the International Standardization Organization (ISO). The ISO standard is intended to provide the fundamental underpinnings for recently mandated daylight standards that rely on bidirectional scattering distribution function data for climate-based daylight modelling and building performance simulations.

Geisler-Moroder, D.↗

Multi-Variable Parametric Analysis of Prototype Building Energy Performance Using Current and Future Weather Scenarios For Data-Driven Market Transformation Support

This project aimed to develop a public building simulation data set that may be used to inform building code development and guidelines for building innovation. The data set consists of several common building types and many representative locations across the United States. A parametric design of building properties was developed to create a range of building energy models that represent common building design decisions with a particular focus on fenestration options. The US Department of Energy prototype building energy models were altered according to a parametric building design and simulated using both current weather data and future weather estimates derived from global climate models. The resulting data set allows for pertinent exploration of building design parameters, including fenestration, within different environments across the United States in the broader context of climate change.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

OpenFacadeControl: enabling integration of automated facades with other building systems

Automated facades are, for the most part, still considered as separate from other building systems throughout the design, installation, commissioning, operation, and maintenance cycle. This takes place despite the fact that their energy and comfort performance are deeply interlinked with the operation of lighting and HVAC systems. Over the last two decades, research has shown that there are significant advantages from operating facades as an integrated system with the rest of the building. Nevertheless, significant barriers prevent this type of integration becoming more common. One of them is the lack of a platform that is inexpensive to implement and that easily allows the practical implementation of integrated control algorithms across fenestration and other building systems, using a variety of communications protocols. This is particularly challenging when automated facades are installed in existing buildings, where interaction with legacy building systems that were installed over the past lifetime of the building can require a high degree of interoperability. OpenFacadeControl (OFC) is an open-source controls framework aimed at unified control of facades and other building systems, including the sharing of third-party sensor information. Through leveraging the Volttron controls platform, it allows the integration of systems and sensors that are manufactured by different companies and that use different communications protocols into an ensemble that functions as a single system. OFC is designed to enable integrated control algorithms of varying degrees of complexity, ranging from simple, heuristic controls to more sophisticated approaches like model-predictive control. Use of a research version to test advanced lighting and shading strategies in a full-scale experimental testbed has demonstrated the ease of deploying advanced control solutions using OpenFacadeControl. This paper presents the structure of OpenFacadeControl and a demonstration case showing the use of OFC in laboratory tests of advanced lighting and fenestration controls that coordinated motorized shades communicating via the BACnet building communications standard and lights communicating via internet-protocol-based application programming interface (API), based on the readings of a shared light level sensor communicating via a different API.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Morphology of human embryonic kidney cells in culture after space flight

The ability of human embyronic kidney cells to differentiate into small epithelioid, large epithelioid, domed, and fenestrated morphological cell types following space flight is examined. Kidney cells exposed to 1 day at 1 g, then 1 day in orbit, and a 12 minute passage through the electrophoretic separator are compared with control cultures. The data reveal that 70 percent of small epithelioid, 16 percent of large epithelioid, 9 percent of dome-forming, and 5 percent of fenestrated cells formed in the space exposed cells; the distributions correlate well with control data. The formation of domed cells from cells cultured from low electrophoretic mobility fractions and small epithelioid cells from high mobility fractions is unaffected by space flight conditions. It is concluded that storage under microgravity conditions does not influence the morphological differentiation of human embryonic kidney cells in low-passage culture.

Todd, P.↗

Coastal lithofacies and biofacies associated with syndepositional dolomitization and silicification (Draken Formation, Upper Riphean, Svalbard)

The Draken Formation (120-250 m) of northeast Spitsbergen (Svalbard) forms part of a thick Upper Proterozoic carbonate platform succession. It consists predominantly of intraformational dolomitic conglomerates, with excellent textural preservation. Six main lithofacies were recognized in the field: quartz sandstones, stromatolitic mats, conglomerates with silicified intraclasts, dolostone conglomerates with desiccated mudrocks, oolitic/pisolitic grainstones and fenestral dolostones. A series of five main gradational biofacies were recognized from silicified (and rare calcified) microfossils. Biofacies 1 represents low-energy subtidal benthos (erect filaments) and plankton (acritarchs and vase-shaped microfossils) whereas biofacies 2 to 5 are microbial mat assemblages (with filamentous mat-builders, and associated dwellers and washed-in plankton) ranging from basal intertidal to high intertidal/supratidal. Colour values (a measure of the lightness of the colour shade) of sawn rock samples were quantified using a Munsell chart, and exhibit a pronounced variation (means of major groups varying from 4.0 to 5.95) across the spectrum of subtidal to supratidal sediments as inferred from other criteria. The lightening in progressively more exposed sediments is related to lowering of organic carbon contents, probably mainly by oxidation. Six types of early cement have been recognized. Calcite microspar (type 1) is common as a subtidal cement in many Proterozoic formations, whereas types 2 (subtidal isopachous fringes), 3 (subtidal hardground dolomicrite) and 4 (intertidal meniscus dolomicrite) are very similar to Phanerozoic examples except for their dolomitic mineralogy. Types 5 and 6 are complex and variable dolomite growths associated with expansion and replacive phenomena. They characterize the fenestral lithofacies and compare with modern supratidal cements. Consideration of diagenetic fabrics and truncation textures of intraclasts indicates that leaching, dolomitization, silicification were all significant syndepositional processes altering the original metastable carbonates. The data set provides evidence for a spectrum of peritidal environments including ooid shoals, protected subtidal, tidal sandflats and protected carbonate mudflats. Different sections show a preponderance of particular facies. The coastal lithofacies continuum was completely dolomitized, unlike offshore to ooid shoal facies of adjacent formations. Dolomitization thus bears a relationship to depositional bathymetry. Although hydrodynamics clearly have a role, the potential importance of whiting precipitation in raising Mg/Ca in marginal marine environments is also stressed.

Non-NASA Center↗

Field validation of isotropic analytical models for simulating fabric shades

Fabric roller shades are common shading materials used in commercial and residential buildings. Accurately characterizing and modeling shades helps practitioners select the appropriate product and its control strategy based on climate and occupants' priorities, such as visual comfort and view to outdoors. Previous studies established a generalized method for modeling complex fenestration systems using data-driven tabulated bidirectional scattering distribution functions. However, deploying such a method at scale to all fabric shading products on the market is too costly and time-consuming. Analytical models that are based on a limited set of measurements (e.g., normal-normal and normal-hemispherical visible transmittance and reflectance, and directional cut-off angles) can be used to model the wide variety of shading products on the market. This study evaluates the performance of two isotropic analytical models, Roos-Wienold and Modified-Kotey, for modeling fabric roller shades, with a focus on the model's ability to predict occupant visual comfort. The performance evaluation was conducted through laboratory and field measurements and simulations. The results showed that both models are sufficient for predicting vertical illuminance at seated eye-level. Roos-Wienold model was able to predict binary visual comfort classification (glare/no-glare) under a wide range of luminance conditions, while Modified-Kotey model did not perform as well under high-contrast low-adaptation conditions. Both models are insufficient in predicting visual comfort at a four-point scale (e.g., imperceptible, perceptible, disturbing, intolerable). The two isotropic models become less accurate when the fabric exhibits high anisotropy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Daylight simulation workflows incorporating measured bidirectional scattering distribution functions

Daylight predictions of architectural spaces depend on good estimates of light transfer through skylights, windows and other fenestration systems. For clear glazing and painted surfaces, parametric transmission and reflection models have proven adequate, but there are many cases where light-scattering, semi-specular shading and daylighting materials defy simple characterization. Something as commonplace as fabric roller shades and venetian blinds may turn daylight prediction into guesswork, and numerous advanced systems on the market tuned specifically to enhance daylight are not sufficiently characterized to distinguish their performance. In this paper, we describe new tools available to handle novel and specialized fabrics, materials, and devices using data-driven modelling of bi-directional scattering distribution functions (BSDFs). These representations are usually tabulated at constant or adjustable angular resolution for efficient point-in-time and annual daylight simulations. We describe a variety of BSDF simulation workflows, including some of the tools and methods that make advanced analysis possible, and highlight some of the current challenges. We conclude with a discussion of future work and how such data might be created and shared worldwide.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field validation of data-driven BSDF and peak extraction models for light-scattering fabric shades

Shading and daylighting systems affect cooling, heating, and lighting energy use by modulating solar radiation through the building façade. Characterizing shading systems holistically and accurately helps designers and engineers evaluate shading systems to achieve energy and non-energy performance goals. These complex fenestration systems can be modeled using Bidirectional Scattering Distribution Functions (BSDF), which map incident radiation to hemispherical distributions of outgoing radiation. Data-driven, tabulated BSDFs are derived from interpolated goniophotometer measured data, then sampled during the raytracing calculation. A peak extraction (PE) algorithm was developed to circumvent limits in BSDF angular resolution, where the specular peak is extracted during simulation by evaluating the BSDF in the through direction and surrounding region. The objective of this study was to validate this measurement and modeling workflow using field monitored data from a full scale testbed with eleven installed fabrics of different weaves, openness factors, and colors and assess the accuracy of the workflow under different adaptation and contrast conditions. Test conditions were limited to clear sky conditions with the sun in the field of view. Results showed that, for tensor tree datasets, vertical illuminance, solar luminance (2.5° apex), and daylight glare probability (DGP) were predicted to within a mean bias error (MBE) error of -456 lx (-12.3%), -3.46e5 (-38.4%), and -0.042 (-7.8%) when full PE occurred. With a binary classification of glare/ no glare, DGP was predicted accurately with a true positive rate of 0.98 and true negative rate of 1.0 using tensor tree data and less accurately with Klems BSDF data, particularly for cases of no glare. The workflow may be of insufficient accuracy to distinguish borderline performance between fabrics using the four-point glare scale, particularly under low adaptation, high contrast daylit conditions. Errors were due to reductions in peak shape and intensity across the BSDF interpolation and data reduction workflow. Future work is needed to better preserve measurement fidelity during interpolation and sampling, which in turn will improve PE performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Automated Production of Optimization-Based Control Logics for Dynamic Facade Systems, with Experimental Application to Two-Zone External Venetian Blinds

The primary goal of this research is to devise a system that produces controllers for complex fenestration systems that perform nearly as well as Model Predictive Control but at a level of cost and implementation complexity that rivals simple heuristic controls. To this end, a cloud-based automated controller production system has been set up for a motorized external Venetian blind device, with a simple web interface that can be used by non-experts. The computation cost per controller is in the range of a few dollars, and the control logic is simple enough to be implemented on small and cheap distributed controllers. The web interface allows the user to specify some details of their particular building and window configuration, including orientation, latitude, interior geometries, and lighting and HVAC system parameters. Upon submittal, a cloud-based system configures the necessary files and commands, and then runs thousands of optimizations with them. Once the calculations are finished, the system produces a lookup table and interpolation-based controller scripts that can be used on a simple and cheap distributed controller. This paper describes the underlying models and optimization processes. It also describes the resulting control logics for two cases tested at Lawrence Berkeley National Laboratory’s Advanced Windows Testbed Facility: illuminance maximization subject to glare constraints; and lighting + HVAC energy minimization. The performance of the model-based controllers produced by the automated web-based system are compared to a heuristic ‘block beam’ controller in physical experiments at the Testbed. The experimental results are supplemented by simulation experiments with the same configuration as the Testbed. The results show the illuminance maximizing controller significantly outperforms the heuristic controller in terms of glare avoidance, and also outperforms it in terms of hours of daylight autonomy. The energy minimizing controller also outperforms the heuristic controller. This paper also discusses how the web-based system may be extended to consider other configurations, such as electrochromic windows and thermally massive HVAC systems. Potential roles for this type of system within the building design and construction industry are discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transformative Building Envelope Retrofit Using Insulation-Inflatable Walls Assisted by Automation

This work highlights the effort to develop a low-cost envelope retrofit for homes built prior to the implementation of energy conservation measures established by the Department of Energy. Inflatable structures were constructed to conform to the exterior envelope (a corner wall construction with a fenestration was used as a prototype). The structures were then filled with spray polyurethane foam insulation. The flexibility in construction and the ability to fill with spray polyurethane foam insulation were demonstrated. In addition, hygrothermal simulations showed that the installation of these systems does not compromise the moisture durability of uninsulated and insulated building envelopes across eight climate zones from hot humid to subarctic. Preliminary cost estimates, based on retail pricing, of the inflatable retrofit including 3 inches of spray foam insulation (insulation value of approximately R 20) is $\$ 4.25$ per square foot uninstalled. The installed cost was calculated using two labor rates, the labor rate for the installation of a weather resistive barrier and the installation of spray foam insulation. Aggregating those values into one labor rate results in an installed cost between $\$ 11$ and $\$ 28$ per square foot. The low end includes the installation of vinyl siding as the exterior cladding. The higher value includes an exterior stucco finish.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Guidelines and Specifications for Enhanced Durability Evaluation of Insulating Glass and Vacuum Insulating Glass Units

The National Renewable Energy Laboratory (NREL) has conducted research into durability of advanced fenestration technologies for almost thirty years. NREL has recently begun to research potential methods to enhance durability evaluation of present market insulating glass units (IGU). This document outlines a proposed process flow for adoption of these methods by interested parties. The proposed evaluation process flow described below is still a topic of active research at NREL as well as with industry partners. NREL will periodically update this document based on research results, both internal and external to NREL that may inform development of improved durability evaluation. This document is also meant to serve as a guideline for interested parties who may wish to engage in enhanced durability evaluation of IGU's both internally or with external testing laboratories. NREL will work to support adoption of the suggestions in this guideline by interested partners in the hope that these practices are more broadly adopted by the industry. Further research into this area will continue to inform both adaptations of this guideline as well as development of improved durability evaluation standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗