Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electrode geometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Shape Matters: Understanding the Effect of Electrode Geometry on Cell Resistance and Chemo-Mechanical Stress

Rechargeable batteries that incorporate shaped three-dimensional electrodes have been shown to have increased power and energy densities when compared to a conventional geometry, i.e. a planar cathode and anode that sandwich an electrolyte. Electrodes can be shaped to enable a higher active material loading, while keeping ion transport distances small. However, the relationship between electrical and mechanical performance of shaped electrodes remains poorly understood. Many electrode designs have been explored, where the electrodes are individually shaped or intertwined, and advances in manufacturing and shape/topology optimization have made such designs a reality. Here, we explore sinusoidal half cells and interdigitated full cells. First, we use a simple electrostatics model to understand the cell resistance as a function of shape. Here we focus on low-temperature conditions, where the electrolyte conductivity decreases relative to that of the electrode; here, LiPF 6 EC:DMC electrolyte and MnO 2 electrode are considered. Next, we use a chemo-mechanics model to examine the stress that arises due to intercalation-driven volume expansion. We show that shaped electrodes provide a significant reduction in resistance in low-temperature conditions, however, they exhibit unfavorable stress concentrations. Overall, we find that the fully interdigitated electrodes may provide the best balance with respect to this resistance-stress trade-off.

25 ENERGY STORAGE↗

Dependence of hydrogen arcjet operation on electrode geometry

The dependence of 2kW hydrogen arcjet performance on cathode to anode electrode spacing was evaluated at specific impulses of 900 and 1000 s. Less than 2 absolute percent change in efficiency was measured for the spacings tested which did not repeat the 14 absolute percent variation reported in earlier work with similar electrode designs. A different nozzle configuration was used to quantify the variation in hydrogen arcjet performance over an extended range of electrode spacing. Electrode gap variation resulted in less than 3 absolute percent change in efficiency. These null results suggested that electrode spacing is decoupled from hydrogen arcjet ignition. The dependence of breakdown voltage on mass flow rate and electrode agreed with Paschen curves for hydrogen. Preliminary characterization of the dependence of hydrogen arcjet ignition on rates of pulse repetition and pulse voltage rise were also included for comparison with previous results obtained using simulated hydrazine.

Pencil, Eric J.↗

Dependence of hydrogen arcjet operation on electrode geometry

The dependence of 2 kW hydrogen arcjet performance on cathode to anode electrode spacing was evaluated at specific impulses of 900 and 1000 s. Less than 2 absolute percent change in efficiency was measured for the spacings tested which did not repeat the 14 absolute percent variation reported in earlier work with similar electrode designs. A different nozzle configuration was used to quantify the variation in hydrogen arcjet performance over an extended range of electrode spacing. Electrode gap variation resulted in less than 3 absolute percent change in efficiency. These null results suggested that electrode spacing is decoupled from hydrogen arcjet performance considerations over the ranges tested. Initial studies were conducted on hydrogen arcjet ignition. The dependence of breakdown voltage on mass flow rate and hydrogen arcjet ignition on rates of pulse repetition and pulse voltage rise were also included for comparison with previous results obtained using simulated hydrazine.

Pencil, Eric J.↗

Electrode geometry for electrostatic generators and motors

An electrostatic (ES) device is described with electrodes that improve its performance metrics. Devices include ES generators and ES motors, which are comprised of one or more stators (stationary members) and one or more rotors (rotatable members). The stator and rotors are configured as a pair of concentric cylindrical structures and aligned about a common axis. The stator and rotor are comprised of an ensemble of discrete, longitudinal electrodes, which are axially oriented in an annular arrangement. The shape of the electrodes described herein enables the ES device to function at voltages significantly greater than that of the existing art, resulting in devices with greater power-handling capability and overall efficiency. Electrode shapes include, but are not limited to, rods, corrugated sheets and emulations thereof.

25 ENERGY STORAGE↗

Using a 3D Porous Flow-Through Electrode Geometry for High-Rate Electrochemical Reduction of CO 2 to CO in Ionic Liquid

Three-dimensional porous flow-through electrodes promise the realization of higher current densities in the electrochemical carbon dioxide reduction reaction (CO 2 RR) by overcoming mass-transport limitations associated with the diffusion of dissolved CO 2 in the bulk electrolyte. Using an ionic-liquid-based electrolyte, [EMIM]BF 4 , offers the additional benefit of higher CO 2 solubility compared to water-based electrolytes. Here, we quantitatively evaluated the effects of flow-driven reactant transport on electrode activity and selectivity for the electrochemical CO 2 RR in [EMIM]BF4. High-surface-area porous flow-through electrodes were fabricated by wet-chemical deposition of Ag nanoflowers on commercial macroporous Al foams. At the highest electrolyte flow-through rate of 100 mL min –1 , we observed a 70-fold increase in partial CO current density, and a 7-fold increase in the Faradaic efficiency toward CO, from 10% without flow to 75% with flow. At the same time, the selectivity changed from oxalate as the main product without flow to CO in the electrolyte flow-through configuration. These results demonstrate that the flow-through approach provides a promising path forward to control selectivity and to overcome mass-transport limitations of the electrochemical CO 2 RR.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microstructural Investigations in Metals Using Atom Probe Tomography with a Novel Specimen-Electrode Geometry

In this work, a new atom probe design is presented along with data showing spectral performance and selected microstructural characterization examples. The instrument includes a curved reflectron, a 532-nm laser, and an integrated, fixed-position, counter electrode in a configuration with moderate electric field enhancement that includes improvements in ease of use and cost of ownership. Both voltage-pulsed and laser-pulsed performance is shown for a variety of materials including Al, Si, W, 316 stainless steel, Inconel 718, and GaN. Characterization of grain boundaries and phase boundaries, including correlation with transmission electron backscatter diffraction results in Inconel 718, is shown. Lastly, a detailed case study of the resultant microstructure between laser-beam and electron-beam additive manufacturing paths in Inconel 718 is also presented.

36 MATERIALS SCIENCE↗

Effect of Approach Speed and Electrode Geometry on Electrostatic Discharges Off Floating Dielectrics

With the damaging effects of electrostatic discharges (ESDs), it is important to study them within various parameter regimes relevant to real-world scenarios. One such scenario studied here is a floating dielectric with no nearby ground plane with a grounded object approaching at a high rate of speed. One may encounter this scenario when moving objects by hand. Discharge current and radiated fields are captured for discharges drawn from polytetrafluoroethylene (PTFE) and poly methyl methacrylate (PMMA) with approach speeds ranging from 20 to 100 mm/s. Previous studies have shown that at lower speeds in metal-to-metal or metal-to-ground backed dielectric geometries, the peak current and discharge distance decrease with increasing speed. However, in the speed range studied here, an increase in distance and current are observed for increasing speed. Namely, the highest speeds coincide with the highest peak currents and discharge distances of approximately 800 mA and up to 24 mm. Further, with no grounded backing, as opposed to setups in other ESD studies, the electric field between the dielectric and an approaching electrode has a more uniform distribution with highest fields at the electrode, which is elucidated to be the driving factor in the differences revealed in this study. Two spheres of differing diameters and a conical electrode are used to draw discharges off the dielectric surfaces. Captured radiated fields via B-dot sensor, plasma imagery via intesified charge-coupled device (ICCD), and mapping of surface potential reveal that a majority of the energy lost during a discharge goes to gas losses and radiated fields.

36 MATERIALS SCIENCE↗

Effect of Coaxial Electrode Geometry on the Electric Field Enhancement Factor for a High Voltage Vacuum Gap

We present an experimental analysis of the change in the electric field enhancement factor with varying gap size and penetration depth (P.D) of cathode into anode for a coaxial vacuum gap, diagnosed using Fowler–Nordheim analysis and optical imaging via scanning electron microscope (SEM) and time integrated Digital single lens reflex camera (DSLR). Data were collected on the Coaxial Gap Breakdown Machine (240 A, 25 kV, 150 ns, 0.1 Hz). Experiments using five different gap sizes at nine different P.Ds are compared over runs comprising 50 shots for each case. The results show a strong link between enhancement factor and gap size, with P.D and surface topology. For large gap sizes, 150, 330, and 700 μm, the average enhancement factor value increases with increasing P.D. For smaller gap sizes, 50 and 100 μm, the average enhancement factor decreases with P.D. SEM imaging before and after plasma formation for each gap size allows for quantifying surface finish, microprotrusion growth, average blast diameter, and an estimation of the surface area breakdowns occupy. Time integrated DSLR imaging analysis of the gap at each shot allows for a determination of the distribution of breakdowns about the circumference of the gap for each case tested. Here, the Fowler–Nordheim analysis allows for a quantitative analysis of the surface roughness of all gap sizes tested. Results show that for large gap sizes, the gap geometry and increasing area of breakdown is the main cause for increasing average enhancement factor. For small gap sizes, the dominant driving factor for small average enhancement factors—that subsequently decrease with P.D—is significant changes in surface topology due to an increased number of breakdowns.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Trak Investigation of Focusing Electrode Geometries for the DARHT Axis-I Diode

An investigation was carried out on the effects of different cathode shroud geometries of the DARHT Axis-1 diode using the Trak ray tracing software. Pierce angles of 20, 30, 45, 60, and 67.5 degrees were investigated. For each geometry the current density with respect to radial position will be presented as it evolves in the longitudinal direction. In addition the emittances for each geometry are compared and this information is used to determine the optimal geometry from the selected angles. These results are compared to the baseline geometry currently employed at DARHT of a simple 2.5mm recessed velvet cathode. Of the selected angles it was found that 45 degrees produced the lowest normalized emittance value, whereas 60 degrees produced the most uniform current density profile at 1cm away from the emission surface. For the purpose of this investigation the effects of the bucking coil and solenoid around the hollow anode of the DARHT Axis I injector are neglected.

47 OTHER INSTRUMENTATION↗

Compact multiwire proportional counters for the detection of fission fragments

Two large area multistep position sensitive (two dimensional) multiwire proportional counters have been developed for experiments involving study of fission dynamics using general purpose scattering chamber facility at IUAC. Both detectors have an active area of 20x10 cm{sup 2} and provide position signals in horizontal (X) and vertical (Y) planes, timing signal for time of flight measurements and energy signal giving the differential energy loss in the active volume. The design features are optimized for the detection of low energy heavy ions at very low gas pressures. Special care was taken in setting up the readout electronics, constant fraction discriminators for position signals in particular, to get optimum position and timing resolutions along with high count rate handling capability of low energy heavy ions. A custom made charge sensitive preamplifier, having lower gain and shorter decay time, has been developed for extracting the differential energy loss signal. The position and time resolutions of the detectors were determined to be 1.1 mm full width at half maximum (FWHM) and 1.7 ns FWHM, respectively. The detector could handle heavy ion count rates exceeding 20 kHz without any breakdown. Time of flight signal in combination with differential energy loss signal gives a clean separation of fission fragments from projectile and target like particles. The timing and position signals of the detectors are used for fission coincidence measurements and subsequent extraction of their mass, angular, and total kinetic energy distributions. This article describes systematic study of these fission counters in terms of efficiency, time resolution, count rate handling capability, position resolution, and the readout electronics. The detector has been operated with both five electrode geometry and four electrode geometry, and a comparison has been made in their performances.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In situ electrochemical high-energy X-ray diffraction using a capillary working electrode cell geometry

The ability to generate new electrochemically active materials for energy generation and storage with improved properties will likely be derived from an understanding of atomic-scale structure/function relationships during electrochemical events. Here, the design and implementation of a new capillary electrochemical cell designed specifically for in situ high-energy X-ray diffraction measurements is described. By increasing the amount of electrochemically active material in the X-ray path while implementing low- Z cell materials with anisotropic scattering profiles, an order of magnitude enhancement in diffracted X-ray signal over traditional cell geometries for multiple electrochemically active materials is demonstrated. This signal improvement is crucial for high-energy X-ray diffraction measurements and subsequent Fourier transformation into atomic pair distribution functions for atomic-scale structural analysis. As an example, clear structural changes in LiCoO 2 under reductive and oxidative conditions using the capillary cell are demonstrated, which agree with prior studies. Accurate modeling of the LiCoO 2 diffraction data using reverse Monte Carlo simulations further verifies accurate background subtraction and strong signal from the electrochemically active material, enabled by the capillary working electrode geometry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electrochemical impedance spectroscopy and finite element analysis modeling of a 4-electrode humidity sensor for natural gas transportation pipelines

Reliable corrosion monitoring of natural gas transmission lines is a major tool providing a foundation for safe management of natural gas infrastructures. Through the development of membrane-based electrochemical sensors which are able to function in low-conductivity gas environments, corrosion monitoring practices can be further strengthened by real-time monitoring of key risk factors such as relative humidity and corrosion rates of corrodible structures. In this work, we demonstrate and validate how a 4-electrode conductivity sensor can provide a means to monitor relative humidity in gases via electrochemical impedance spectroscopy through finite element analysis (FEA). For a relative humidity range of 5%–55%, the impedance response varied from 1 kΩ to 66 kΩ, showing a high sensitivity for gas humidity. To confirm that the measured impedance values reliably interpreted relative humidity, it was found that precise estimation of the sensor’s cell constant was needed. FEA was used to assess how the cell constant depended on the electrode geometry, membrane geometry, and electrode placement within the sensor. Through this approach, assumptions about the characteristic area and length were validated using electrolyte equipotential and current density vector mapping. This reduced possible cell constant uncertainties by 70%. Here, with a cell constant of 14.84 cm –1 , obtained via FEA, membrane conductivity values were in good agreement with published data.

47 OTHER INSTRUMENTATION↗

Proximity Ferroelectricity in Compositionally Graded Structures

Proximity ferroelectricity is a novel paradigm for inducing ferroelectricity in a non-ferroelectric polar material, such as AlN or ZnO that are typically unswitchable with an external field below their dielectric breakdown field. When placed in direct contact with a thin switchable ferroelectric layer (such as Al 1-x Sc x N or Zn 1-x Mg x O), they become a practically switchable ferroelectric. Using the thermodynamic Landau-Ginzburg-Devonshire theory, in this work, we perform the finite element modeling of the polarization switching in the compositionally graded AlN-Al 1-x Sc x N, ZnO-Zn 1-x Mg x O, and MgO-Zn 1-x Mg x O structures sandwiched in both a parallel-plate capacitor geometry as well as in a sharp probe-planar electrode geometry. We reveal that the compositionally graded structure allows the simultaneous switching of spontaneous polarization in the whole system by a coercive field significantly lower than the electric breakdown field of unswitchable polar materials. The physical mechanism is the depolarization electric field determined by the gradient of chemical composition “x”. The field lowers the steepness of the switching barrier in the otherwise unswitchable parts of the compositionally graded AlN-Al 1-x Sc x N and ZnO-Zn 1-x Mg x O structures. In the MgO-like regions of the compositionally graded MgO-Zn 1-x Mg x O structure, a shallow double-well free energy potential emerges. Proximity ferroelectric switching of the compositionally graded structures placed in the probe-electrode geometry occurs due to nanodomain formation under the tip. We predict that a gradient of chemical composition “x” significantly lowers effective coercive fields of the compositionally graded AlN-Al 1-x Sc x N and ZnO-Zn 1-x Mg x O structures compared to the coercive fields of the corresponding multilayers with a uniform chemical composition in each layer. A tip-induced switching further lowers the coercive field, enabling control of ferroelectric domains in otherwise unswitchable compositionally graded structures, which can provide nanoscale domain control for memory, actuation, sensing, and optical applications.

36 MATERIALS SCIENCE↗

Self-Supporting, Hydrophobic, Ionic Liquid-Based Reference Electrodes Prepared by Polymerization-Induced Microphase Separation

Interfaces of ionic liquids and aqueous solutions exhibit stable electrical potentials over a wide range of aqueous electrolyte concentrations. This makes ionic liquids suitable as bridge materials that separate in electroanalytical measurements the reference electrode from samples with low and/or unknown ionic strengths. However, methods for the preparation of ionic liquid-based reference electrodes have not been explored widely. We have designed a convenient and reliable synthesis of ionic liquid-based reference electrodes by polymerization-induced microphase separation. This technique allows for a facile, single-pot synthesis of ready-to-use reference electrodes that incorporate ion conducting nanochannels filled with either 1-octyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide or 1-dodecyl-3-methylimidazolium bis(trifluoromethyl sulfonyl)imide as ionic liquid, supported by a mechanically robust cross-linked polystyrene phase. This synthesis procedure allows for the straightforward design of various reference electrode geometries. These reference electrodes exhibit a low resistance as well as good reference potential stability and reproducibility when immersed into aqueous solutions varying from deionized, purified water to 100 mM KCl, while requiring no correction for liquid junction potentials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Novel methods for improvement of a Penning ion source for neutron generator applications

Penning ion source performance for neutron generator applications is characterized by the atomic ion fraction and beam current density, providing two paths by which source performance can be improved for increased neutron yields. We have fabricated a Penning ion source to investigate novel methods for improving source performance, including optimization of wall materials and electrode geometry, advanced magnetic confinement, and integration of field emitter arrays for electron injection. Effects of several electrode geometries on discharge characteristics and extracted ion current were studied. Additional magnetic confinement resulted in a factor of two increase in beam current density. First results indicate unchanged proton fraction and increased beam current density due to electron injection from carbon nanofiber arrays.

43 PARTICLE ACCELERATORS↗

Fully Coupled Simulation of Lithium Ion Battery Cell Performance

Lithium-ion battery particle-scale (non-porous electrode) simulations applied to resolved electrode geometries predict localized phenomena and can lead to better informed decisions on electrode design and manufacturing. This work develops and implements a fully-coupled finite volume methodology for the simulation of the electrochemical equations in a lithium-ion battery cell. The model implementation is used to investigate 3D battery electrode architectures that offer potential energy density and power density improvements over traditional layer-by-layer particle bed battery geometries. Advancement of micro-scale additive manufacturing techniques has made it possible to fabricate these 3D electrode microarchitectures. A variety of 3D battery electrode geometries are simulated and compared across various battery discharge rates and length scales in order to quantify performance trends and investigate geometrical factors that improve battery performance. The energy density and power density of the 3D battery microstructures are compared in several ways, including a uniform surface area to volume ratio comparison as well as a comparison requiring a minimum manufacturable feature size. Significant performance improvements over traditional particle bed electrode designs are observed, and electrode microarchitectures derived from minimal surfaces are shown to be superior. A reduced-order volume-averaged porous electrode theory formulation for these unique 3D batteries is also developed, allowing simulations on the full-battery scale. Electrode concentration gradients are modeled using the diffusion length method, and results for plate and cylinder electrode geometries are compared to particle-scale simulation results. Additionally, effective diffusion lengths that minimize error with respect to particle-scale results for gyroid and Schwarz P electrode microstructures are determined.

25 ENERGY STORAGE↗

The smooth transition from field emission to a self-sustained plasma in microscale electrode gaps at atmospheric pressure

We report on the existence of a smooth transition from field emission to a self-sustained plasma in microscale electrode geometries at atmospheric pressure. This behavior, which is not found at macroscopic scales or low pressures, arises from the unique combination of large electric fields that are created in microscale dimensions to produce field-emitted electrons and the high pressures that lead to collisional ionization of the gas. Using a tip-to-plane electrode geometry, currents less than 10 μA are measured at onset voltages of ∼200 V for gaps less than 5 μm, and analysis of the current–voltage (I-V) relationship is found to follow Fowler–Nordheim behavior, confirming field emission. As the applied voltage is increased, gas breakdown occurs smoothly, initially resulting in the formation of a weak, partial-like glow and then a self-sustained glow discharge. Remarkably, this transition is essentially reversible, as no significant hysteresis is observed during forward and reverse voltage sweeps. In contrast, at larger electrode gaps, no field emission current is measured and gas breakdown occurs abruptly at higher voltages of ∼400 V, absent of any smooth transition from the pre-breakdown condition and is characterized only by glow discharge formation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗