Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electrode geometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Study of Influence of Electrode Geometry on Impedance Spectroscopy

Electrochemical Impedance Spectroscopy (EIS) is a powerful and proven tool for analyzing AC impedance response. A conventional three electrode EIS method was used to perform the investigation in the present study. Saturated potassium chloride solution was used as the electrolyte and three different material rods were used as working electrodes. Different configurations of electrode area were exposed to the electrolyte as an active area to investigate electrode geometry effects. Counter to working electrode distance was also altered while keeping the working electrode effective area constant to explore the AC response dependence on the variation of ion travel distance. Some controlled experiments were done to validate the experimental setup and to provide a control condition for comparison with experimental results. A frequency range of 100 mHz to 1 MHz was used for all experiments. In our analysis, we have found a noteworthy influence of electrode geometry on AC impedance response. For all electrodes, impedance decreases with the increase of effective area of the electrolyte. High frequency impedance is not as dependent on geometry as low frequency response. The observed phase shift angle drops in the high frequency region with increased working electrode area, whereas at low frequency the reverse is true. Resistance and capacitive reactance both decrease with an increase of area, but resistance response is more pronounce than reactance. For lower frequencies, small changes in working area produce very distinctive EIS variations. Electrode material as well as geometry was systematically varied in the present study. From these and other studies, we hope to develop a fundamental foundation for understanding specific changes in local geometry in fuel cell (and other) electrodes as a method of designing local morphology for specific performance.

30 DIRECT ENERGY CONVERSION↗

Circular electrode geometry metal-semiconductor-metal photodetectors

The invention comprises a high speed, metal-semiconductor-metal photodetector which comprises a pair of generally circular, electrically conductive electrodes formed on an optically active semiconductor layer. Various embodiments of the invention include a spiral, intercoiled electrode geometry and an electrode geometry comprised of substantially circular, concentric electrodes which are interposed. These electrode geometries result in photodetectors with lower capacitances, dark currents and lower inductance which reduces the ringing seen in the optical pulse response.

Mcaddo, James A.↗

Circular electrode geometry metal-semiconductor-metal photodetectors

The invention comprises a high speed, metal-semiconductor-metal photodetector which comprises a pair of generally circular, electrically conductive electrodes formed on an optically active semiconductor layer. Various embodiments of the invention include a spiral, intercoiled electrode geometry and an electrode geometry comprised of substantially circular, concentric electrodes which are interposed. These electrode geometries result in photodetectors with lower capacitances, dark currents and lower inductance which reduces the ringing seen in the optical pulse response.

Mcadoo, James A.↗

Two-phase flow numerical analysis of electrode geometry for alkaline water electrolyzers

Hydrogen is a promising component of a future energy-secure and efficient economy, but its competitiveness depends on reducing production costs. One strategy is to operate alkaline water electrolyzers at higher current densities to increase output. However, this intensifies performance losses due to gas bubble accumulation, which blocks transport pathways and deactivates electrochemically active surfaces. Enhancing bubble evacuation through electrode design is therefore essential. Previous studies have explored various approaches — such as modifying surface morphology, applying sonication or pressure modulation, and introducing surfactants — but these efforts have addressed a limited range of conditions due to the complexity of two-phase flow and electrode geometries. Experiments have also largely been focused on either cell level improvements, which lack the information necessary to isolate each contributing factor, or on modified geometries that are not relevant to practical cell operation. From a modeling perspective, conventional Eulerian multiphase models do not track the complex gas–liquid interfacial dynamics and often neglect surface tension and contact angle effects, reducing their predictive accuracy. To provide insights on the effects of different electrode geometries on the performance of alklaine water electrolyzers this work employs an immersed boundary volume-of-fluid method to simulate bubble behavior in 3D porous electrodes. Multiple base electrode geometries, typically used in practice, with varying porosity are evaluated under a constant surface gas generation rate. Simulation data is analyzed to quantify electrode gas coverage, bubble size dynamics and other relevant metrics. Results show that porosity strongly influences bubble accumulation on electrode surfaces, with higher porosity reducing gas coverage, and its not strictly dependent on the electrode geometry. However, the electrode’s base geometry significantly affects gas accumulation at the separator gap, independent of porosity. A foam electrode geometry resulted in the lowest gas coverage of all electrodes with a median volumetric gas coverage of 11%, but at the cost of a 70% reduction in active area compared with the largest surface area electrode, while gyroid electrodes showed the best trade-off between gas coverage, particularly at the separator surface, and electrochemically active area. In conclusion, the results highlight the need for holistic electrode design strategies.

Alkaline↗

Effect of Electrode Geometry on the Classification Performance of Rapid Evaporative Ionization Mass Spectrometric (REIMS) Bacterial Identification

The recently developed automated, high-throughput monopolar REIMS platform is suited for the identification of clinically important microorganisms. Although already comparable to the previously reported bipolar forceps method, optimization of the geometry of monopolar electrodes, at the heart of the system, holds the most scope for further improvements to be made. For this, sharp tip and round shaped electrodes were optimized to maximize species-level classification accuracy. Following optimization of the distance between the sample contact point and tube inlet with the sharp tip electrodes, the overall cross-validation accuracy improved from 77% to 93% in negative and from 33% to 63% in positive ion detection modes, compared with the original 4 mm distance electrode. As an alternative geometry, round tube shaped electrodes were developed. Geometry optimization of these included hole size, number, and position, which were also required to prevent plate pick-up due to vacuum formation. Additional features, namely a metal “X”-shaped insert and a pin in the middle were included to increase the contact surface with a microbial biomass to maximize aerosol production. Following optimization, cross-validation scores showed improvement in classification accuracy from 77% to 93% in negative and from 33% to 91% in positive ion detection modes. Supervised models were also built, and after the leave 20% out cross-validation, the overall classification accuracy was 98.5% in negative and 99% in positive ion detection modes. This suggests that the new generation of monopolar REIMS electrodes could provide substantially improved species level identification accuracies in both polarity detection modes. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling of the effects of non-equilibrium excitation and electrode geometry on H 2 /air ignition in a nanosecond plasma discharge

In this work, we present the results of two-dimensional modeling of the effects of non-equilibrium excitation and electrode geometry on H 2 /air ignition in a nanosecond plasma discharge. A multiscale adaptive reduced chemistry solver for plasma assisted combustion (MARCS-PAC) based on PASSKEy discharge modeling package and compressible multi-component reactive flow solver ASURF+ is developed and validated. This model is applied to simulate the impact of non-equilibrium plasma excitation and electrode geometry and heat loss on the dynamics of the discharge from streamer to spark and ignition kernel development in a H 2 /air mixture with a pair of cylindrical electrodes. The results show that the plasmagenerated species (N 2 (A), N 2 (B), N 2 (a'), N 2 (C), O( 1 D), O and H) in the spark and afterglow significantly accelerate the ignition kernel development. The increase of discharge voltage at the same total discharge energy promotes the non-equilibrium active species production. It is found that the production of electronically excited species at higher reduced electric field strength is more efficient in enhancing ignition in comparison to the vibrational excitation and heating. Moreover, the 2D simulation clearly reveals that the electric field and active species distribution are highly non-uniform. The streamers are initiated at the sharp outer edges of the negative and positive electrodes by a strong electric field while the electric field is much weaker at the centerline of the electrodes. Furthermore, the simulations reveal that the ignition enhancement is sensitive to the variation of electrode shape, diameter, and gap size due to the changes of electric field distribution and location of streamer formation. A cylindrical electrode produces a larger discharge volume and ignition kernel than the parabolic and spherical electrodes, when the discharge is localized near the axis of the gap. It is found that there is a non-monotonic dependence of ignition kernel size on the electrode diameter and inter-electrode distance. The increase of electrode diameter and gap size above the optimal conditions leads to the reduction of ignition kernel volume, due to the decrease of active species concentration and gas temperature. At a larger electrode surface area and electrode diameter as well as smaller electrode gap size, the heat loss to electrode plays a greater role in reducing the ignition kernel size and slowing ignition kernel development. This work provides insights and guidance to understand the kinetic enhancement of non-equilibrium plasma and the effects of electrode geometries on ignition for the optimization ignitors in advanced engines.

42 ENGINEERING↗

Effects of electrode geometry on the ion beam extraction of closed drift type anode layer linear ion source

Closed drift type anode layer linear ion source was investigated with focusing on the electrode geometry effects on ion beam emission and anode layer formation. In the electrode geometry, the discharge gap between anode and cathode plays an important role to control anode layer formation as well as electron generation. When the discharge gap is increased from 2 to 3 mm, the ion current density was enhanced from 0.9 to 1.35 mA/cm{sup 2}. Computational simulation by using an object oriented particle in cell showed that the discharge volume was extended due to enhanced electron generation and the electric field at the anode layer was enhanced from 1.32 to 1.52 MV/cm.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Why diamond dimensions and electrode geometry are crucial for small photon beam dosimetry

Recent use of very small photon beams (down to 4 mm) in stereotactic radiotherapy requires new detectors to accurately determine the delivered dose. Diamond detectors have been presented in the literature as an attractive candidate for this application, due to their small detection volume and the diamond atomic number (Z = 6) which is close to water effective atomic number (Zeff ∼ 7.42). However, diamond exhibits a density 3.51 times greater than that of water and recent studies using Monte Carlo simulations have demonstrated the drawback of a high-density detector on small beam output factors. The current study focuses on geometrical parameters of diamond detector, namely, the diamond dimensions and the electrode geometry, in order to solve the dosimetric issues still observed in small photon beams with diamond detectors. To give better insights to these open questions, we have used both computational method and experimental analysis. This study highlighted that reducing diamond dimensions is crucial for small beam output factor measurements and to limit the influence of its high density. Furthermore, electrodes covering the whole diamond surface were essential for a dose rate independence of the diamond detector. The optimal dosimeter derived from this work presented small diamond dimensions of approximately 1 × 1 × 0.15 mm{sup 3}, with diamond-like-carbon electrodes covering the whole diamond surface. A dose rate independence of this diamond detector (better than 0.5% over a wide range of dose rates available on a stereotactic dedicated facility) was obtained due to the electrode geometry. Concerning the output factor measurements, a good agreement (better than 1.1%) was observed between this carbon material detector and two types of passive dosimeters (LiF microcubes and EBT2 radiochromic films) for all beam sizes except the smallest field of 0.6 × 0.6 cm{sup 2} with a deviation of 2.6%. This new study showed the high performance of this diamond detector in small photon beams, in comparison with various commercially available passive and active dosimeters.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Approximations useful for the prediction of electrostatic discharges for simple electrode geometries

The report provides approximations for estimating the capacitance and the ratio of electric field strength to potential for a certain class of electrode geometries. The geometry consists of an electrode near a grounded plane, with the electrode being a surface of revolution about the perpendicular to the plane. Some examples which show the accuracy of the capacitance estimate and the accuracy of the estimate of electric field over potential can be found in the appendix. When it is possible to estimate the potential of the electrode, knowing the ratio of electric field to potential will help to determine if an electrostatic discharge is likely to occur. Knowing the capacitance will help to determine the strength of the discharge (the energy released by it) if it does occur. A brief discussion of discharge mechanisms is given. The medium between the electrode and the grounded plane may be a neutral gas, a vacuum, or an unchanged homogeneous isotropic dielectric.

Edmonds, L.↗

Approximations useful for the prediction of electrostatic discharges for simple electrode geometries

The report provides approximations for estimating the capacitance and the ratio of electric field strength to potential for a certain class of electrode geometries. The geometry consists of an electrode near a grounded plane, with the electrode being a surface of revolution about the perpendicular to the plane. Some examples which show the accuracy of the capacitance estimate and the accuracy of the estimate of electric field over potential can be found in the appendix. When it is possible to estimate the potential of the electrode, knowing the ratio of electric field to potential will help to determine if an electrostatic discharge is likely to occur. Knowing the capacitance will help to determine the strength of the discharge (the energy released by it) if it does occur. A brief discussion of discharge mechanisms is given. The medium between the electrode and the grounded plane may be a neutral gas, a vacuum, or an unchanged homogeneous isotropic dielectric.

Edmonds, Larry D.↗

Interdigitated electrode geometry variation and external quantum efficiency of GaN/AlGaN-based metal-semiconductor-metal UV photodetectors

Aluminum gallium-nitride (Al x Ga 1–x N)-based metal–semiconductor–metal (MSM) ultraviolet photodetectors photodetectors (PD’s) have been successfully designed and fabricated using conventional photolithography techniques and tested experimentally to study their spectral sensitivity across different Al content, x, with x varying from 0 to 0.3. (Al)GaN-based UV PD’s have wide and tunable direct band gaps. The ability to easily select the photodetected wavelength by simply varying the aluminum content of GaN thin film (Al x Ga 1–x N) is a significant advantage of these group III–V compounds. Typically, MSM PD’s grown on (Al)GaN thin films result in ultrafast photodetection because of their highly mobile carriers. These devices are limited by the carrier transit time due to the negligible capacitance presented by the interdigitated fingers. Various electrode geometries were fabricated to investigate the influence of metal contact shapes on the devices’ performance indices with emphasis on the response speed and bias-voltage–independent efficiency. Here, coupled with the independently measured Hall mobility and electric field, we computed the carrier transit time of the devices to be as short as 1.31 ps and the bias-voltage–independent external quantum efficiencies were as high as 70% at 60 V for n-doped and intrinsic devices when operated in the reverse bias regime. Here, (Al x )Ga 1–x N photodetectors were designed to explore spectral sensitivity by altering x from 0 to 0.3.

42 ENGINEERING↗

Boosting the External Quantum Efficiency of AlGaN-Based Metal–Semiconductor–Metal Ultraviolet Photodiodes by Electrode Geometry Variation

Fast aluminum-gallium-nitride–based metal–semiconductor–metal ultraviolet photodiodes were successfully designed, fabricated, and characterized using conventional photolithography techniques. Various electrode geometries were fabricated to investigate the influence of metal contact shapes on the device performance indices with emphasis on the response speed and bias-voltage–independent efficiency. Furthermore, based on the independently measured Hall mobility and electric field, we evaluated the carrier transit time of the devices as 1.31 ps with bias-voltage–independent external quantum efficiency of 1198% in photoconductive mode at 19.5 V and 70% at 60 V for n -doped and intrinsic devices, respectively.

42 ENGINEERING↗

Hysteresis in amplitudes of self-excited oscillations for co-axial electrode-geometry DC glow discharge plasma

Hysteresis in amplitudes of the self-excited oscillations of the floating potential and discharge current is observed in an unmagnetized co-axial electrode-geometry DC glow discharge plasma system. The nonlinearities of these oscillations are studied using standard dynamical analysis tools. The characterization revealed the transition of low-amplitude high-frequency period-n oscillations to a large amplitude low frequency period-1 oscillations through a chaotic intermediate route. The transition of the low amplitude, high frequency period-n oscillations to chaotic type is observed to be linked to the dynamical change in the plasma system, i.e., after a negative differential resistance (NDR) region, whereas the transition from chaotic to period-1 is observed to be linked to a discharge current threshold.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of Bubbles on Liquid Nitrogen Breakdown in Plane-Plane Electrode Geometry From 100-250 kPa

Liquid nitrogen (LN(2)) is used as the cryogen and dielectric for many high temperature superconducting, high voltage applications. When a quench in the superconductor occurs, bubbles are generated which can affect the dielectric breakdown properties of the LN(2). Experiments were performed using plane-plane electrode geometry where bubbles were introduced into the gap through a pinhole in the ground electrode. Bubbles were generated using one or more kapton heaters producing heater powers up to 30 W. Pressure was varied from 100-250 kPa. Breakdown strength was found to be relatively constant up to a given heater power and pressure at which the breakdown strength drops to a low value depending on the pressure. After the drop the breakdown strength continues to drop gradually at higher heater power. This is particularly illustrated at 100 kPa. After the drop in breakdown strength the breakdown is believed to be due to the formation of a vapor bridge. Also the heater power at which the breakdown strength changes from that of LN(2) to that of gaseous nitrogen increases with increasing pressure. The data can provide design constraints for high temperature superconducting fault current limiters (FCLs) so that the formation of a vapor bridge can be suppressed or avoided.

36 MATERIALS SCIENCE↗

Modeling the electrode geometry of co-planar capacitors for the microwave dielectric characterization of ceramic thin films

This paper describes the influence of co-planar electrode geometry on the measurement accuracy of microwave dielectric properties of sol-gel-derived Na{sub 0.5}Bi{sub 0.5}TiO{sub 3}-NaTaO{sub 3} thin films. The interdigital, co-planar capacitor configurations were prepared with E-beam lithography. A combination of analytical and numerical modelling was used for the optimization of co-planar, interdigital electrode structures for the thin-film characterization. We observed that the number of fingers, their length, as well as the gap between the fingers of the interdigital electrode structure of the co-planar capacitor have a pronounced influence on the accuracy of measurements.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Characteristics of low-energy ion beams extracted from a wire electrode geometry

Beams of argon ions with energies less than 50 eV were extracted from an ion source through a wire electrode extractor geometry. A retarding potential energy analyzer (RPEA) was constructed in order to characterize the extracted ion beams. The single aperture RPEA was used to determine the ion energy distribution function, the mean ion energy and the ion beam energy spread. The multi-cusp hot cathode ion source was capable of producing a low electron temperature gas discharge to form quiescent plasmas from which ion beam energy as low as 5 eV was realized. At 50 V extraction potential and 0.1 A discharge current, the ion beam current density was around 0.37 mA/cm{sup 2} with an energy spread of 3.6 V or 6.5% of the mean ion energy. The maximum ion beam current density extracted from the source was 0.57 mA/cm{sup 2} for a 50 eV ion beam and 1.78 mA/cm{sup 2} for a 100 eV ion beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗