Laser induced spark ignition of methane-oxygen mixtures

The use of laser-induced spark ignition in liquid-propellant rocket engines is investigated by studying the ignition of mixtures of methane and oxygen. Specific attention is given to minimum ignition energy, spark efficiency, the effect of ignition energy on flame kernels, the effect of laser wavelength, and comparisons with electrode-spark ignition. A pulsed frequency-doubled Nd:YAG laser is tested at atmospheric pressure and 296 K under both laminar-premixed and turbulent-incompletely-mixed conditions. Laser sparks of 10 and 40 mJ and an electrode spark of 6 mJ are measured for flame-kernel radius as a function of time with pulsed laser shadowgraphy. Initially, the flame-kernel size is similar to those predicted by the Taylor spherical-blast-wave model, and subsequent growth is characterized by rapid acceleration. The growth rate is significantly affected by the effect of incomplete fuel-oxidizer mixing.

Lee, T. W.↗

Evaluation of 2-μm Pulsed Integrated Path Differential Absorption Lidar for Carbon Dioxide Measurement—Technology Developments, Measurements, and Path to Space

The societal benefits of understanding climate change through the identification of global carbon dioxide sources and sinks led to the recommendation for NASA's Active Sensing of Carbon Dioxide Emissions over Nights, Days, and Seasons space-based mission for global carbon dioxide measurements. For more than 15 years, the NASA Langley Research Center has developed several carbon dioxide active remote sensors using the differential absorption lidar technique operating at 2-μm wavelength. Recently, an airborne double-pulsed integrated path differential absorption lidar was developed, tested, and validated for atmospheric carbon dioxide measurement. Results indicated 1.02% column carbon dioxide measurement uncertainty and 0.28% bias over the ocean. Currently, this technology is progressing toward triple-pulse operation targeting both atmospheric carbon dioxide and water vapor-the dominant interfering molecule on carbon dioxide remote sensing. Measurements from the double-pulse lidar and the advancement of the triple-pulse lidar development are presented. In addition, measurement simulations with a space-based IPDA lidar, incorporating new technologies, are also presented to assess feasibility of carbon dioxide measurements from space.

Singh, Upendra N.↗

Twelve-crystal prototype of Li 2 MoO 4 scintillating bolometers for CUPID and CROSS experiments

An array of twelve 0.28 kg lithium molybdate (LMO) low-temperature bolometers equipped with 16 bolometric Ge light detectors, aiming at optimization of detector structure for CROSS and CUPID double-beta decay experiments, was constructed and tested in a low-background pulse-tube-based cryostat at the Canfranc underground laboratory in Spain. Performance of the scintillating bolometers was studied depending on the size of phonon NTD-Ge sensors glued to both LMO and Ge absorbers, shape of the Ge light detectors (circular vs. square, from two suppliers), in different light collection conditions (with and without reflector, with aluminum coated LMO crystal surface). The scintillating bolometer array was operated over 8 months in the low-background conditions that allowed to probe a very low, μBq/kg, level of the LMO crystals radioactive contamination by 228 Th and 226 Ra.

47 OTHER INSTRUMENTATION↗

A first test of CUPID prototypal light detectors with NTD-Ge sensors in a pulse-tube cryostat

CUPID is a next-generation bolometric experiment aiming at searching for neutrinoless double-beta decay with ~250 kg of isotopic mass of 100 Mo. It will operate at ~10 mK in a cryostat currently hosting a similar-scale bolometric array for the CUORE experiment at the Gran Sasso National Laboratory (Italy). CUPID will be based on large-volume scintillating bolometers consisting of 100 Mo-enriched Li 2 MoO 4 crystals, facing thin Ge-wafer-based bolometric light detectors. In the CUPID design, the detector structure is novel and needs to be validated. In particular, the CUORE cryostat presents a high level of mechanical vibrations due to the use of pulse tubes and the effect of vibrations on the detector performance must be investigated. In this paper we report the first test of the CUPID-design bolometric light detectors with NTD-Ge sensors in a dilution refrigerator equipped with a pulse tube in an above-ground lab. Light detectors are characterized in terms of sensitivity, energy resolution, pulse time constants, and noise power spectrum. Despite the challenging noisy environment due to pulse-tube-induced vibrations, we demonstrate that all the four tested light detectors comply with the CUPID goal in terms of intrinsic energy resolution of 100 eV RMS baseline noise. Indeed, we have measured 70–90 eV RMS for the four devices, which show an excellent reproducibility. We have also obtained high energy resolutions at the 356 keV line from a 133 Ba source, as good as Ge semiconductor γ detectors in this energy range.

47 OTHER INSTRUMENTATION↗

The efficiency of photovoltaic cells exposed to pulsed laser light

Future space missions may use laser power beaming systems with a free electron laser (FEL) to transmit light to a photovoltaic array receiver. To investigate the efficiency of solar cells with pulsed laser light, several types of GaAs, Si, CuInSe2, and GaSb cells were tested with the simulated pulse format of the induction and radio frequency (RF) FEL. The induction pulse format was simulated with an 800-watt average power copper vapor laser and the RF format with a frequency-doubled mode-locked Nd:YAG laser. Averaged current vs bias voltage measurements for each cell were taken at various optical power levels and the efficiency measured at the maximum power point. Experimental results show that the conversion efficiency for the cells tested is highly dependent on cell minority carrier lifetime, the width and frequency of the pulses, load impedance, and the average incident power. Three main effects were found to decrease the efficiency of solar cells exposed to simulated FEL illumination: cell series resistance, LC 'ringing', and output inductance. Improvements in efficiency were achieved by modifying the frequency response of the cell to match the spectral energy content of the laser pulse with external passive components.

Lowe, R. A.↗

PSMC Upgrade Development Documentation and Functional Testing

The functional verification consists of verifying that the calibration (a.k.a. gain matching) is accurate and that there is no double pulsing or signal cross talk and interference. The calibration is shown to be satisfactory from the plateau plots on the right. The absence of double pulsing and cross talk can be seen in the time-interval diagram below. Both phenomena are manifested by spikes in the time interval distribution around 1µs to 5µs. No such spike is present.

3-He detector electronics↗

Holographic flow visualization at NASA Langley

Holographic flow visualization systems at two NASA Langley facilities, a hypersonic blow-down tunnel using CF4 gas and an expansion tube with very short test time, are described. A pulsed ruby laser is used at a CF4 tunnel for single pulse holography, double pulse with several minutes between exposures, and dual plate holographic interferometry. Shadowgraph, schlieren, and interferograms are reconstructed from the holograms in a separate reconstruction lab. At the expansion tube the short run time of 200 microseconds requires precise triggering of its double pulsed ruby laser. With double pulse capability of 20 to 1200 microseconds pulse separation, one pulse can occur before and one later after flow is established to obtain fringe free background interferograms (perfect infinite fringe) or both pulses can occur during flow in order to study flow instabilities. Holograms are reconstructed at the expansion tube with an in-place setup which makes use of a high power CW Argon laser and common optics for both recording and reconstructing the holograms. The holographic systems at the CF4 tunnel and expansion tube are operated routinely for flow visualization by tunnel technicians. Typical flow visualization photographs from both facilities are presented.

Burner, A. W.↗

Holographic Flow Visualization at NASA Langley

Holographic flow visualization systems at two NASA Langley facilities, a hypersonic blow-down tunnel using CF4 gas and an expansion tube with very short test time, are described. A pulsed ruby laser is used at a CF4 tunnel for single pulse holography, double pulse with several minutes between exposures, and dual plate holographic interferometry. Shadow-graph, schlieren, and interferograms are reconstructed from the holograms in a separate reconstruction lab. At the expansion tube the short run time of 200 microseconds requires precise triggering of its double pulsed ruby laser. With pulse separation, one pulse can occur before and one after flow is established to obtain fringe free background interferograms (perfect infinite fringe) or both pulses can occur during flow in order to study flow instabilities. Holograms are reconstructed at the expansion tube with an in-place setup which makes use of a high power CW Argon laser and common optics for both recording and reconstructing the holograms. The holographic systems at the CF4 tunnel and expansion tube are operated routinely for flow visualization by tunnel technicians. Typical flow visualization photographs from both facilities are presented.

Burner, A. W.↗

Development of an airborne laser bathymeter

An airborne laser depth sounding system was built and taken through a complete series of field tests. Two green laser sources were tried: a pulsed neon laser at 540 nm and a frequency-doubled Nd:YAG transmitter at 532 nm. To obtain a depth resolution of better than 20 cm, the pulses had a duration of 5 to 7 nanoseconds and could be fired up to at rates of 50 pulses per second. In the receiver, the signal was detected by a photomultiplier tube connected to a 28 cm diameter Cassegrainian telescope that was aimed vertically downward. Oscilloscopic traces of the signal reflected from the sea surface and the ocean floor could either be recorded by a movie camera on 35 mm film or digitized into 500 discrete channels of information and stored on magnetic tape, from which depth information could be extracted. An aerial color movie camera recorded the geographic footprint while a boat crew of oceanographers measured depth and other relevant water parameters. About two hundred hours of flight time on the NASA C-54 airplane in the area of Chincoteague, Virginia, the Chesapeake Bay, and in Key West, Florida, have yielded information on the actual operating conditions of such a system and helped to optimize the design. One can predict the maximum depth attainable in a mission by measuring the effective attenuation coefficient in flight. This quantity is four times smaller than the usual narrow beam attenuation coefficient. Several square miles of a varied underwater landscape were also mapped.

Kim, H., H.↗

Immunity Study: Port Impedance Measurement of PMU and PCI testing under EMP

With the increased requirements of real-time grid monitoring, disturbance location, and situation awareness, Phasor Measurement Units (PMUs) have become more critical for the Wide Area Measurement System (WAMS). However, the vulnerability of PMUs has not been well studied, especially under electromagnetic pulse (EMP) scenarios. The stable operation of the power system will be affected directly once EMP damages them. Therefore, studying their immunity to EMP events is urgent and necessary. In this paper, the effective impedance measurement scheme and pulsed current injection (PCI) testing are proposed for the port impedance measurement and immunity levels of PMUs. The equivalent non-uniform transmission line model is established to eliminate the impact of the fixture in the de-embedding process. Then, the circuit of the pulsed current generator is set to generate a damping sinusoid, and the double exponential wave is applied to the port. Finally, using measured impedance as a generator load, the voltage and current responses of different ports are calculated in the PCI testing simulation. In conclusion, results reveal the characteristics of port impedance, waveforms of voltage and current, and distribution of accumulative energy. The relation between port impedance and the waveforms is discussed.

42 ENGINEERING↗

Preliminary Arc-Jet tests of ablator/RSI joints in simulated space shuttle ascent and entry heating

Five ablator/RSI panels were tested in simulated Shuttle heating conditions to determine heat pulse effects on the ablator and the ablator/RSI joints. Two of the panels were subjected to both ascent and entry heating. The other three panels were subjected to entry heating only. The double-pulse heating (ascent plus entry) had no significant effect on char-layer integrity. Evaluation of the effects of entry heating on the ablator/RSI joints was difficult because, with the panel configuration used, severe pressure gradients developed within some of the joints during testing causing hot-gas flow through the joints. In joints where pressure leaks apparently did not develop, temperatures within the joints were reasonable compared to ablator and RSI back surface temperatures.

Brewer, W. D.↗

Simulated Lorentz Force Detuning Compensation With A Double Lever Tuner On A Dressed ILC/1.3 GHZ Cavity At Room Temperature

Pulsed SRF linacs with high accelerating gradients experience large frequency shifts caused by Lorentz force detuning (LFD). A piezoelectric actuator with a resonance control algorithm can maintain the cavity frequency at the nominal level, thus reducing the RF power. This study uses a double lever tuner with a piezoelectric actuator for compensation and another piezoelectric actuator to simulate the effects of the Lorentz force pulse. A double lever tuner has an advantage by increasing the stiffness of the cavity-tuner system, thus reducing the impact of LFD. The tests are conducted at room temperature and with a dressed 1.3 GHz 9-cell cavity.

43 PARTICLE ACCELERATORS↗

Semispan Test Results of an Active Flow Control Enabled High-Lift Common Research Model in Landing Configuration

A 10%-scale semispan, Active Flow Control (AFC) enabled, simplified high-lift version of the Common Research Model (CRM-SHL-AFC) was tested in the 14- by 22-Foot Subsonic Tunnel at the NASA Langley Research Center. The main objective of the test was to develop an AFC system that can provide the necessary lift recovery on a simple-hinged flap high-lift system while minimizing its pneumatic power requirement. Three new types of AFC approaches were examined: Double-Row Sweeping Jets (DRSWJ), Alternating Pulsed Jets (APJ), and High Efficiency Low Power (HELP) actuators. The DRSWJ and the APJ actuators used two rows of unsteady jets, whereas the HELP actuators used an upstream row of sweeping jets combined with a downstream row of steady jets to overcome strong adverse pressure gradients. The test was conducted mostly at a freestream Mach number of 0.20. For exploration purposes, a limited number of runs were made at lower Mach numbers or using vortex generators (VGs). Minimal sensitivity to Mach number or VGs, for the cases evaluated, were observed. The AFC-induced lift coefficient increment was maintained over the AFC-off case for most flow-control cases examined. The CRM-SHL-AFC configuration equipped with HELP actuation was the only actuator configuration able to match or exceed the targeted lift performance of a reference conventional high-lift configuration. The presented aerodynamic data include lift, drag, and pitching moment coefficients as a function of angle of attack, with and without the Transonic Wall Interference Correction System (TWICS) method applied. Lift increments as a function of AFC pneumatic power usage (i.e., nozzle pressure ratio, mass flow, momentum coefficient, and power coefficient) are also presented at a lower angle of attack (α = 8.9°) and at maximum lift (α= 17.1°). At the two angles of attack, the surface pressure distributions and autospectral densities from the unsteady pressure transducers for the AFC-off case and the best HELP actuation case are compared.

high-lift↗

Immunity Study: Port Impedance Measurement of PMU and PCI testing under EMP

Phasor Measurement Units (PMUs) are critical for the Wide Area Measurement System (WAMS), especially for real-time grid monitoring, disturbance location, and situation awareness. Once they are damaged, the stable operation of the power system will be affected directly and greatly. Therefore, it is urgent and necessary to study their immunity to electromagnetic pulse (EMP) events. In this paper, an effective impedance measurement scheme is proposed for port impedance measurement of PMU. The equivalent non-uniform transmission line model is established to eliminate the impact of the fixture in the de-embedding process. Then circuit of pulsed current generator is established to generate damping sinusoid and double exponential wave applied to the port. Finally, by using measured impedance as a load of the generator, the voltage and current responses of different ports are calculated in the pulsed current injection (PCI) testing simulation. Results show that common-mode impedance is large and differential mode impedance is small. The critical condition will appear in the common mode for voltage and differential mode for current.

Zhang, Liang↗

Development of Double and Triple-Pulsed 2-micron IPDA Lidars for Column CO2 Measurements

Carbon dioxide (CO2) is an important greenhouse gas that significantly contributes to the carbon cycle and globalradiation budget on Earth. CO2 role on Earth’s climate is complicated due to different interactions with various climatecomponents that include the atmosphere, the biosphere and the hydrosphere. Although extensive worldwide efforts formonitoring atmospheric CO2 through various techniques, including in-situ and passive sensors, are taking place highuncertainties exist in quantifying CO2 sources and sinks. These uncertainties are mainly due to insufficient spatial andtemporal mapping of the gas. Therefore it is required to have more rapid and accurate CO2 monitoring with higheruniform coverage and higher resolution. CO2 DIAL operating in the 2-μm band offer better near-surface CO2measurement sensitivity due to the intrinsically stronger absorption lines. For more than 15 years, NASA LangleyResearch Center (LaRC) contributed in developing several 2-m CO2 DIAL systems and technologies. This paperfocuses on the current development of the airborne double-pulsed and triple-pulsed 2-m CO2 integrated pathdifferential absorption (IPDA) lidar system at NASA LaRC. This includes the IPDA system development andintegration. Results from ground and airborne CO2 IPDA testing will be presented. The potential of scaling suchtechnology to a space mission will be addressed.

Singh, Upendra N.↗

Multiple scattering effects on the Linear Depolarization Ratio (LDR) measured during CaPE by a Ka-band air-borne radar

Air-borne radar measurements of thunderstorms were made as part of the CaPE (Convection and Precipitation/Electrification) experiment in Florida in July 1991. The radar has two channels, X-band (10 GHz) and Ka-band (34.5 GHz), and is capable of measuring cross-polarized returns as well as co-polarized returns. In stratiform rain, the cross-polarized components can be observed only at the bright band region and from the surface reflection. The linear depolarization ratios (LDR's) measured at X-band and Ka-band at the bright band are nearly equal. In convective rain, however, the LDR in Ka-band often exceeds the X-band LDR by several dB, and sometimes by more than 10 dB, reaching LDR values of up to -5 dB over heavy convective rain. For randomly oriented hydrometeors, such high LDR values cannot be explained by single scattering from non-spherical scattering particles alone. Because the LDR by single backscatter depends weakly on the wavelength, the difference between the Ka-band and X-band LDR's suggests that multiple scattering effects prevail in the Ka-band LDR. In order to test this inference, the magnitude of the cross-polarized component created by double scattering was calculated using the parameters of the airborne radar, which for both frequencies has beamwidths of 5.1 degrees and pulse widths of 0.5 microsecond. Uniform rain beyond the range of 3 km is assumed.

Iguchi, Toshio↗

Pulsed Ejector Thrust Amplification Tested and Modeled

There is currently much interest in pulsed detonation engines for aeronautical propulsion. This, in turn, has sparked renewed interest in pulsed ejectors to increase the thrust of such engines, since previous, though limited, research had indicated that pulsed ejectors could double the thrust in a short device. An experiment has been run at the NASA Glenn Research Center, using a shrouded Hartmann-Sprenger tube as a source of pulsed flow, to measure the thrust augmentation of a statistically designed set of ejectors. A Hartmann- Sprenger tube directs the flow from a supersonic nozzle (Mach 2 in the present experiment) into a closed tube. Under appropriate conditions, an oscillation is set up in which the jet flow alternately fills the tube and then spills around flow emerging from the tube. The tube length determines the frequency of oscillation. By shrouding the tube, the flow was directed out of the shroud as an axial stream. The set of ejectors comprised three different ejector lengths, three ejector diameters, and three nose radii. The thrust of the jet alone, and then of the jet plus ejector, was measured using a thrust plate. The arrangement is shown in this photograph. Thrust augmentation is defined as the thrust of the jet with an ejector divided by the thrust of the jet alone. The experiments exhibited an optimum ejector diameter and length for maximizing the thrust augmentation, but little dependence on nose radius. Different frequencies were produced by changing the length of the Hartmann-Sprenger tube, and the experiment was run at a total of four frequencies. Additional measurements showed that the major feature of the pulsed jet was a starting vortex ring. The size of the vortex ring depended on the frequency, as did the optimum ejector diameter.

Wilson, Jack↗