Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “differential transformation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Utah FORGE: Pump and Probe Test on a Mated Fracture Westerly Granite Sample

This dataset contains results from a pump and probe experiment conducted on a mated fracture Westerly Granite sample with a diameter of 1 inch and a height of 2 7/8 inches. The experiment was performed within an aluminum triaxial pressure vessel (TEMCO) to investigate the non-linear acoustic parameters of the sample under varying axial pressures. The confining pressure was maintained at 4 MPa, while the axial pressure was incrementally reduced from 17 MPa to 1 MPa in 1 MPa steps. 5 dynamic pressure oscillations of 0.5 MPa were applied over a 10 minute interval. The dataset includes pump controller data, linear variable differential transformer (LVDT) measurements, and acoustic data. The pump controller data tracks the confining and axial pressures, flow rates, and pump volumes. LVDT measurements provide detailed records of the axial displacement of the cell piston. Additionally, acoustic data captured by s-wave transducers is archived in a compressed file.

15 GEOTHERMAL ENERGY↗

Out-of-Pile Test of LVDT-Based Creep Test Rig at PWR Prototypical Conditions

New and improved materials are being considered to support the existing nuclear reactors and future next-generation reactors. The materials can significantly degrade and limit their properties in harsh reactor environments. To accurately understand the material’s degradation, real-time data is required under prototypic-irradiation conditions. Additionally, understanding the creep behavior of materials under harsh environments is essential for an evaluation of safety concerns. To provide these capabilities, the Idaho National Laboratory’s (INL’s) High Temperature Test Laboratory (HTTL) has developed several instrumented test rigs to obtain real-time data from specimens in well-controlled pressurized water reactor (PWR) coolant conditions in the Materials and Test Reactors (MTRs). This technical report focuses on INL’s efforts to evaluate and enhance the former prototype creep test rig that relied on linear variable differential transformers in laboratory settings. Specifically, the test rig is capable of detecting changes in the length of tensile specimen, which is useful for measuring thermal expansion and creep loading.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Real-Time, In-pile Creep Test Rigs for Characterizing the Structural Materials of Nuclear Components

New and improved materials are being considered for supporting both existing and next-generation nuclear reactors. Reactor materials can significantly degrade with time, thus limiting or altering their properties in harsh reactor environments. To accurately understand such material degradation, real-time data obtained under prototypic irradiation conditions are required. In particular, understanding the creep behavior of materials exposed to irradiation and elevated temperatures is essential for safety concern evaluations. To provide these capabilities, Idaho National Laboratory (INL)’s High Temperature Test Laboratory (HTTL) developed several instrumented test rigs for obtaining real-time data from specimens in well-controlled pressurized-water reactor (PWR) coolant conditions at the Materials Test Reactor. This technical report focuses on INL’s efforts to evaluate and enhance the former creep test rig prototype that relied on linear variable differential transformers in laboratory settings. Specifically, the test rig can detect changes in the length of creep specimens, which is useful for measuring thermal expansion and creep deformation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Technical Guidance on Use of the Linseis Vertical Dilatometer L75

Linseis vertical Dilatometer L75 thermal expansion equipment is a complete system which can be used for measuring change of the absolute length of a sample, determination of the thermal expansion coefficient (CTE), shrinkage, and sintering. The 238 Pu Supply Program is interested in re-establishing the capability to determine CTE and measuring the change of the absolute length of various 237 Np Al/cermet samples during heating. The change in length of the measured sample is recorded using a highly sensitive Linear Variable Differential Transformer (LVDT). The dilatometer is user-friendly and simple to operate which will allow technicians to be trained easily on its use. This equipment was designed to be used specifically for ceramics. It has a highly vacuum tight push rod dilatometer, a high-resolution inductive transducer using innovative and comprehensive temperature controls which provide excellent performance as a measurement system yielding high accuracy, reproducibility, and long-term stability.

07 ISOTOPE AND RADIATION SOURCES↗

Improved Creep Testing Approach for Bentonite EBS

In the United States, the nuclear reactor contributes 18.7 percent of the nation’s total electricity generation and produces a significant amount of spent nuclear fuel (SNF) and high-level waste. Because SNF is being stored for longer periods than initially envisioned, the U.S. Department of Energy Office of Nuclear Energy, Office of Spent Fuel and Waste Science and Technology is assessing the technical performance of the SNF storage systems after extended durations. The concept of a sustainable geologic repository for SNF disposal relies heavily on the safety provided by multiple barriers, such as repository host rock, overlying rock formation, and human-made engineered barrier systems (EBS). One of the major components of EBS is bentonite-based buffer materials that isolate the nuclear-waste canisters from the host rock and fill the void left in the horizontally drilled boreholes. The resaturated bentonite has a swelling characteristic, which is useful for self-sealing the microcracks in the host rock and supporting the canister’s heavy weight. However, factors such as nonuniformity in the saturation, swelling pressure of bentonite, and the high temperature at the canister-bentonite interface may lead to instability of the waste canister inside the borehole. Therefore, evaluating the long-term deformation of bentonite-based material is necessary. RESPEC Company, LLC recently completed a preliminary study for the U.S. Department of Energy (DE SC0022804) that is attempting to understand the time-dependent deformation in the consolidated sand/bentonite (SB) specimens through triaxial creep experiments and improve the understanding of EBS performance under anticipated repository conditions. The project included developing a standard testing procedure for preparing the consolidated core specimen from a mixture of sand and bentonite in a 50:50 ratio by weight, fabricating a new pressure vessel in-house, modifying existing creep equipment to perform triaxial creep experiments on consolidated SB specimens, and performing six long-term triaxial creep experiments under low-deviatoric stress at two different temperature conditions, which is representative of hypothetical conditions that might be encountered in a geologic repository within a reasonable rate of success in completing creep experiments. The consolidated SB specimen was prepared using the novel specimen preparation procedure and had physical characteristics (e.g., moisture content and bulk density) reasonably comparable with the properties of bentonite-based buffer, which is proposed to be used in the EBS in the Swedish KBS-3H design and the Swiss design of SNF disposal in the horizontal drifts. The newly fabricated pressure vessel could withstand the confining pressure of up to 15 megapascals (MPa) while maintaining the test temperature of up to 90 degrees Celsius (°C) for long-term creep experiments. The preliminary results from the triaxial creep experiments suggested that the consolidated SB specimen may experience time-dependent deformation at a low-deviatoric stress state and room temperature condition. Based on the deformation recorded in the SB specimen from axial and radial linear variable differential transformers (LVDTs) and physical characteristic changes, it is apparent that the time-dependent deformation is a combination of consolidation and creep, which is influenced by the level of deviatoric stresses and temperature. The systematic creep testing of bentonite-based specimens helped develop a standard testing procedure applicable for analyzing the similar characteristics of shale or clay-like materials in different geologic conditions outside repository science, including in civil engineering and infrastructure projects, underground and open pit mining, and deep drilling.

58 GEOSCIENCES↗

Report on technical development in ANL for innovative creep testing and measurement

This report summarizes a research effort undertaken by Argonne National Laboratory to accelerate the development of creep data package for ASME code qualification. Progress on the fabrication of a 3-sample load train and the application of a direct current potential drop (DCPD) technique to measure large creep strains are reported. Specifically: (1) The 3-sample load train, with three sets of Linear Variable Differential Transformers (LVDT), has been fabricated and assembled. (2) A DCPD method for creep-strain measurement up to 50% has been demonstrated. The DCPD data matches very well to LVDT results, suggesting its potential application in future creep testing. The technical developments contribute towards shortening the time needed to generate a creep data package for an ASME code case of the laser powder bed fusion 316H stainless steel, an effort under the US Department of Energy’s Advanced Materials and Manufacturing Technologies (AMMT) program.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Performance Test of Mini LVDT - ELVIS

The Institute for Energy (IFE) Technology has been a pioneer in the development of Linear Variable Differential Transformers (LVDTs) for in-pile testing, deploying over 2,200 units in various reactor environments with less than a 10% failure rate after five years of operation. This report focuses on the performance testing of IFE’s Mini LVDT, a compact sensor ideal for material test reactor experiments. The Mini LVDT, with a limited range of +/- 1.5 mm, offers excellent performance comparable to larger LVDTs, making it valuable in space-constrained applications. The development of an Enhanced Linear Variable Intrinsic Sensor (ELVIS) with internal temperature monitoring capabilities represents a significant advancement, addressing the critical need for real-time, accurate measurements in high-radiation and high-temperature environments. Two ELVIS prototypes were evaluated in terms of both temperature and displacement, showcasing promising results, though challenges with noise during temperature measurements were identified. This report summarizes the rigorous testing performed at Idaho National Laboratory (INL) and highlights the potential applications of Mini LVDTs and ELVIS in nuclear and other high-precision industries.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Conceptual Designs for Irradiation Creep Testing of SiC in HFIR

Understanding irradiation creep of nuclear fuel cladding is important to properly size the initial fuel-cladding gap and understand when pellet-cladding contact is expected to occur due to a combination of fuel swelling and cladding creep-down. Irradiation creep also plays a role in relaxing stresses that develop in-pile. Silicon carbide fiber–reinforced silicon carbide matrix (SiC/SiC) composites are the leading long-term accident-tolerant fuel cladding concept for light-water reactors (LWRs). Although some limited data are available regarding irradiation creep of the individual constituents (fibers, matrix), data regarding irradiation creep of SiC/SiC composites are currently insufficient. Additional data regarding irradiation creep compliance and the rupture lifetime (combination of creep and slow crack growth) are needed to understand material limitations. This work describes the design and development of two irradiation vehicles that are being pursued for testing SiC/SiC concepts in the High Flux Isotope Reactor (HFIR). The first is a passive experiment, referred to as the PRECISE experiment, that leverages the constant coolant pressure of HFIR to compress a metallic bellows and provide a well-characterized load to drive creep in a SiC/SiC dog bone specimen. The total creep strain would be quantified post-irradiation by measuring dimensional changes of the specimen length as well as local dimensional changes within the gauge region. Non-stressed specimens would also be irradiated under the same conditions to provide an indication of dimensional changes due to radiation-induced swelling in the absence of creep. A second, more complex experiment, referred to as the INSITE experiment, is being designed in parallel that would use pneumatics to pressurize a metal bellows and linear variable differential transformers (LVDTs) to measure the specimen displacement in situ during irradiation. Such an experiment would provide significantly more data regarding the evolution of the creep compliance as a function of dose and applied stress within a single experiment but would require significantly more development time and cost to execute. The primary concern with the INSITE experiment is the accuracy, reliability, and expected lifetime of the LVDTs during irradiation at elevated temperatures. Efforts are being made to adjust the experiment design and operating procedure to limit LVDT temperatures and mitigate or otherwise compensate for uncertainties due to factors such as temperature fluctuations, creep in the surrounding structural materials, and drift of the LVDTs. This work describes the experiment designs, thermal and structural analysis that were performed to ensure that the desired temperature and stress conditions can be achieved, some initial sensitivity analyses to predict the evolution of the radiation-induced specimen displacements, and potential sources of uncertainty in the measurements. Out-of-pile testing is being performed in parallel to confirm that the test trains achieve the expected stress states in the specimens and do not result in prohibitive stress concentrators (e.g., in the grip regions) that might risk pre-mature failure. The PRECISE experiments are proceeding toward fabrication and assembly with HFIR insertion planned during fiscal year 2026. The INSITE experiment is progressing toward out-of-pile demonstrations, which will provide more conclusive evidence regarding the feasibility of executing these tests in HFIR or whether alternative displacement monitoring techniques may need to be considered.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Performance Testing of Enhanced Linear Variable Integrated Sensor (ELVIS III) for LVDTs

The Enhanced Linear Variable Intrinsic Sensor (ELVIS) was a 2024 breakthrough discovery by Idaho National Laboratory (INL) in terms of further innovating the usage of all linear variable differential transformers (LVDTs) and enhancing their performance in harsh environments. In irradiation tests conducted within material test reactors (MTRs), LVDTs with an internal temperature sensing capability can address several critical challenges. This report focuses on performance testing of the ELVIS III device with new hybrid LVDTs provided by the Institute for Energy Technology (IFE), which is the world’s sole supplier of nuclear-grade LVDTs. The ELVIS III device was evaluated in terms of temperature showcasing promising results comparable to a typical type-K thermocouple (TC).

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Noncontacting vibration transducer has constant sensitivity

Noncontacting transducer with constant sensitivity automatically measures the vibration amplitudes along the span of a vibrating structure of irregular contour. A system employing a feedback control positions the transducer at a constant height above the test surfaces. A differential transformer facilitates calibration and extends the amplitude range of the system.

Flagge, B.↗

Electronic skewing circuit monitors exact position of object underwater

Linear Variable Differential Transformer /LVDT/ electronic skewing circuit guides a long cylindrical capsule underwater into a larger tube so that it does not contact the tube wall. This device detects movement of the capsule from a reference point and provides a continuous signal that is monitored on an oscilloscope.

Roller, R.↗

Deflection circuit monitors force on object under water

Capsule containing samples for radiation testing is guided under through a seal to an exact position within a nuclear reactor. A Linear Variable Differential Transformer /LVDT/ flexplate deflection circuit monitors the force on the capsule as it is positioned within the reactor.

Roller, R.↗

A dilatometer for volume-temperature determinations of liquids.

An instrument is described for the continuous volume measurement of small (3.7 ml) samples of liquids as a function of temperature. The sample is sealed in a stainless steel bellows chamber. Volume changes are measured with a linear variable differential transformer while temperature is measured by means of a thermistor and associated circuitry. Volume changes can be determined to better than .1 microliter ml over a temperature range of 10-60 C. The maximum sample volume change is 7%.

Rothman, J. E.↗

High-pressure high-temperature transducer

Compact instrument has active and reference sides consisting of tubes that elongate in response to increasing interior pressures. Relative displacement of tubes is measured by linear variable differential transformer to determine pressure on active side. Device needs no internal cooling, thus eliminating condensation problem with gases containing saturated steam.

Vrolyk, J. J.↗

LVDT gage for fracture-toughness tests in liquid hydrogen

Linear-variable differential transformer replaces conventional resistance strain gages to measure crack-mouth-opening displacement. LVDT is superior in tests under liquid hydrogen, where boiling of hydrogen on resistive is suited to broad temperature range and hostile environments such as nuclear reactors.

Pierce, W. S.↗

Fast-Acting Electrohydraulic Servo

Electrohydraulic servo controls moving elements of airflow valve. Position of moving element and attached piston is monitored by linear variable-differential transformer (LVDT). Single-stage servo valve lets fluid into and out of piston volume in response to feedback signals from the LVDT.

Webb, J. A. J.↗