Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cryogenic air separation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Oxy-Combustion System Process Optimization

The overall objective of this work is to develop a new chemical absorbent-based, high pressure, CO 2 purification system to remove the residual oxygen that currently contaminates the recovered CO 2 , and to optimize the Pressurized Oxy-Combustion (POxC) process to minimize the Cost of Electricity (COE) generated in this advanced combustion process. TDA developed and validated the performance of the oxygen removal system for CO 2 purification. In collaboration with the Advanced Power & Energy Program (APEP) of University of California, Irvine (UCI), we optimized the POxC process, including thermal management, heat integration, and power cycle optimization using process design and modeling supported with Aspen Plus® process simulations. The techno-economic analysis results indicate that the pressurized oxycombustion coal power plant with Ion-transport membrane (ITM) air separation unit (ASU) (Case 2 – 30.55%) does not show an advantage over a cryogenic ASU (Case 1 – 31.24%) while TDA’s sorption-based ASU (Case 4 - 32.61%) shows a significant advantage over the cryogenic ASU (Case 1 – 331.24%). The specific plant costs show a wide range with a low of $2544/kW for Case 11C (TDA ASU, co-sequestering the SO x , and ultra-supercritical steam cycle) to a high of $2975/kW for Case 12A (cryogenic ASU and sCO 2 cycle). In general, the ITM ASU based cases have lower specific plant costs than the corresponding cryogenic ASU based cases while the TDA ASU based cases show the lowest specific plant costs. The main reason for lowering these costs is the higher overall plant thermal efficiency which decreases the plant cost on a $ per kW basis. Next comparing the cases with different power cycle working fluid conditions in terms of temperature and pressure while all utilizing steam, similar trends as the plant costs may be observed. However, with the supercritical CO 2 (sCO 2 ) cycle, the increase in thermal efficiency of the sCO 2 cycle was not able to offset its increase in plant cost making the plant costs higher than those of the corresponding steam cycle cases. The Cost of Electricity (COE) again shows similar trends as the specific plant costs. The COE for Case 11C at $110.1/MWh is also the lowest, but among all cases that do not co-sequester the SO x , Case 12C (TDA ASU and sCO 2 cycle) has the lowest COE at $\$$117.5/MWh while the highest is for Case 8A (cryogenic ASU and supercritical steam cycle) at $130.4/MWh.

20 FOSSIL-FUELED POWER PLANTS↗

Krypton Concentration using HZ-PAN

Idaho National Laboratory (INL) has developed and tested engineered sorbents to separate and capture volatile fission products such iodine, xenon (Xe), and krypton (Kr) from off-gas streams. As noble gases, Xe and Kr can be difficult to capture and separate. Historically, cryogenic distillation has been used to execute the separation. However, performing this separation from bulk air streams is expensive and can pose significant hazards. INL has successfully developed two different sorbents for Xe and Kr capture, silver mordenite polyacrylonitrile and hydrogen mordenite polyacrylonitrile (HZ-PAN). Adsorption studies to date successfully separated and captured Kr from carrier gas streams, but those studies focused primarily on initial separation and capture. Successful utilization in a used nuclear fuel (UNF) reprocessing facility, however, requires further concentration of the Kr to minimize long term storage volumes. This study focuses on the concentration of Kr utilizing HZ PAN as the concentrating media. Concentrating Kr during desorption is ideal for two reasons: one, to produce Kr that can be used for commercial and research applications, or two, to minimize the volume of the radioactive gaseous waste stream for disposal. This report investigates the Kr concentrating potential of HZ-PAN by running multiple Kr adsorption-desorption cycles, collecting the desorbed effluent from a saturated HZ-PAN column, and loading it onto a fresh column. This study demonstrates that four adsorption-desorption cycles can transform a 150 ppmv Kr stream into a 37.5% Kr stream, an overall concentration factor of 2497. Each concentration step results in successively smaller volumes desorbed, reducing volume by a factor of approximately 40,000. Depending on the operational goals, during desorption one could collect smaller volume fractions of high concentration Kr (~ 67%). This demonstration should be considered proof-of-concept. Further refinement is necessary to develop optimum operating schemes to integrate into UNF off-gas treatment.

12 - MGMT OF RADIOACTIVE AND NON-RADIOACTIVE WASTE↗

Factors that Impact the Redox Kinetics Associated with Sr1-xAxFeO3 (A = Ca, Ba) in Air Separations Technologies

Perovskite oxides, including SrFeO3-δ, have garnered significant interest for their impressive oxygen storage thermodynamics and kinetics. While traditional oxygen production is performed through cryogenic separation methods at the industrial scale, oxygen carrier-based separations have offered an attractive alternative at the modular scale. Perovskites are considered ideal oxygen carriers, with their structural flexibility minimizing both the thermodynamic barrier and the structural strain related to the oxygen uptake/release cycle. Our latest work has identified a few major factors that directly impact the oxygen release thermodynamics and kinetics for Sr1-xAxFeO3-δ (A = Ca, Ba) materials including elemental composition, crystallographic symmetry, surface area, and pretreatment conditions. This presentation will discuss these factors using Sr1¬-xCaxFeO3 and Ba1-xSrxFeO3 to illustrate their individual and collective impacts on the design of high-performance oxygen carriers when operating at 300-700 °C. Additionally, we will discuss how each of these factors can be leveraged for the numerous catalytic applications also dependent on the redox properties of mixed metal oxides.

Popczun, Eric↗

Porosity in Sr 1-x Ca x FeO 3-δ oxygen carriers: The role of surface area and pretreatment on storage activity

Perovskite oxides have generated interest as robust, low-temperature oxygen carrier materials for a variety of clean energy applications, including chemical looping gasification and air separations. Methods to improve O 2 desorption kinetics are vital to allow these carriers to compete economically with traditional metal oxide carriers or cryogenic separations. In this report we investigated the cumulative roles that surface area, pretreatment, and elemental composition have on the oxygen storage properties of a state-of-the-art carrier system, Sr 1-x Ca x FeO 3-δ (x = 0.20, 0.25, 0.30) synthesized using multiple methods. Porous materials synthesized by the Pechini, or citrate, method had their surface area controlled using the synthesis temperature. The high surface area of the Sr 0.7 Ca 0.3 FeO 3-δ materials is most beneficial at low operating temperatures, such as 350 and 400 °C, as their reduction rates are twice as fast as those obtained with their bulk counterparts. These effects are observed at higher operating temperatures and within a single composition, but temperature tunability using variable Ca 2+ substitution in the Sr 1-x Ca x FeO 3-δ overshadows the improvements gained from higher surface areas. Additionally, we establish that pretreatment in N2 at an elevated temperature is necessary to enhance kinetics further. For maximum efficiency, pretreatment at the synthesis temperature is suggested for the Pechini method-synthesized systems, whereas 800 °C is adequate for bulk materials.

36 MATERIALS SCIENCE↗

Predicting Liquid–Liquid Phase Separation of Submicrometer Proxies for Atmospheric Secondary Aerosol

Liquid–liquid phase separation (LLPS) of atmospheric aerosols can significantly impact climate, air quality, and human health. However, their complex composition, small size, and history-dependent properties result in great uncertainty in the modeling of aerosol phase state and atmospheric processes. Herein, using cryogenic transmission electron microscopy (cryo-TEM), we examined model submicron aerosols composed of organic compounds and ammonium sulfate, and established a parameterization for the separation relative humidity (SRH) that accounts for chemical composition, particle size, and equilibration time. We evaluated different variables that describe chemical composition: O/C ratio, partition coefficient, solubility, molar mass, and polarizability. The O/C ratio fits the SRH of micrometer droplets best, and by using a scaling factor to translate the micrometer SRH parameterization to submicron aerosols, we incorporate the effects of size and equilibration time. The measured scaling factor for the submicron mean SRH (30nm – 1μm, 20 min equilibration times) is 0.80, the factor becomes 1 with equilibration time over 1 hour, and is equal to 0, meaning that SRH is absent, when the aerosol dry diameter is smaller than 30 nm. Furthermore, our parameterization will aid in universal SRH modeling, potentially leading to more accurate predictions of aerosol mass, optical properties, hygroscopicity, and heterogeneous chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Chemical looping air separation with Sr 0.8 Ca0.2Fe 0.9 Co 0.1 O 3-δ perovskite sorbent: Packed bed modeling, verification, and optimization

Chemical looping air separation (CLAS) represents a promising approach for efficient O 2 production from the air. This present study aims at optimizing the absorber/desorber operations and the separation process with extensive experimental validation. Specifically, a one-dimensional packed bed model was developed to investigate the CLAS operation with a Sr 0.8 Ca 0.2 Fe 0.9 Co 0.1 O 3-δ perovskite sorbent. The redox thermodynamics of perovskite sorbent was measured by TGA and then incorporated into a linear driving force model to describe the O 2 absorption and desorption rates. Both 4-step and 5-step air separation cycle configurations, with various cyclic structures, were performed in a subpilot-scale packed bed. The model predicted O2 purity and productivity were consistent with experimental results, supporting its accuracy and applicability. Parametric analysis and multi-objective optimization were further carried out to assess the performance of CLAS. Both O 2 purity and recovery increased monotonically with the cycle time, airflow rate, steam flow rate, and absorption pressure. Meanwhile, optimal O 2 productivity and power consumption can only be achieved by specific combinations of these parameters. The optimized results showed that CLAS can be highly competitive when compared to conventional pressure swing adsorption (PSA) or cryogenic distillation. The 5-step cycle configuration achieved a minimum power consumption of 118 kW·h for producing 1 ton O 2 with ≥ 95% purity. The maximum O 2 productivity reached 0.0932 g O2 /(g sorbent ·h) with 390 kW·h/ton O 2 of energy consumption (95% pure). The optimization results also indicate that CLAS can potentially be more efficient than cryogenic distillation even when the required O 2 purity is above 99%.

42 ENGINEERING↗

Cryogenic Carbon Capture™ Technoeconomic Analysis

The Cryogenic Carbon Capture™ (CCC) process significantly decreases cost and energy demands for CO 2 separation and pressurization to 150 bar compared to alternatives. The process is a post-combustion technology that cools CO 2 -laden flue gas to desublimation temperatures (-100 to -135 °C), separates solid CO 2 —that forms from the flue gas—from the light gases, uses the cold products to cool incoming gases in a recuperative heat exchanger, compresses the solid/liquid CO 2 to final pressures (100–200 bar), and delivers a compressed CO 2 stream separated from an atmospheric pressure light-gas stream. The overall energy and economic costs are about 30-50% lower than most competing processes that involve air separation units (ASUs), solvents, or similar technologies. In addition, the CCC process enjoys several ancillary benefits, including (a) it is a minimally invasive Bolton technology, (b) it provides highly efficient removal of most pollutants (Hg, SOx, NO 2 , HCl, etc.), and (c) possible energy storage capacity. This report outlines the process details and economic and energy comparisons relative to other well-documented alternatives. This paper presents the results of a detailed techno-economic comparison of CCC with amine-based systems. The comparison uses identical financial and economic assumptions similar process assumptions as the detailed analyses published by US DOE in the greenfield analysis. Specifically, the comparison assumes power plants that produce the same net output, one equipped with and a second without carbon capture. Separately, the paper compares similar analyses for retrofitting existing systems using typical plant characteristics in the US (initial capital costs have been paid, high plant utilization), though there are no DOE estimates available for direct comparison. Financial and technical assumptions for all comparisons are maintained as close to the DOE reference studies as possible. The results demonstrate about 30-50% lower costs and energy demands for capture from greenfield coal plants. Natural gas plants produce substantially lower CO 2 concentrations which makes the cost of capturing a ton of CO 2 at the same capture rate as the coal plant higher for all processes while the cost of CO 2 capture per unit of power generation is lower. However, CCC maintains about the same absolute energy and cost advantages for NG as for coal compared to amine systems. Finally, the costs of retrofitting a station are compared to those of building a new station with and without capture. The retrofit costs are comparable to (slightly lower than) new plant costs without capture. In all cases operating and capital cost comparisons show that the CCC process can be retrofitted to a variety of plants to cost effectively reduce CO 2 emissions. Further process integration into the upstream processes and unique process features like water recovery, and integrated energy storage bring the effective cost of carbon capture using the CCC process down further and increase its advantages over alternatives. This technoeconomic analysis shows that the CCC process has the potential to the be lowest cost carbon capture technology under development today.

20 FOSSIL-FUELED POWER PLANTS↗

Integrated Pumped Thermal and Liquid Air Energy Storage

Liquid air energy storage (LAES) and pumped thermal energy storage (PTES) are two closely related technologies that employ thermodynamic cycles to store electricity in the form of thermal energy. This chapter describes the integration of PTES and LAES in a single combined cycle (PT-LAES), where the PTES side provides the cold source required to drive the air liquefaction process. This presents several advantages compared to the separate cycles, including the partial or complete removal of cold stores, a higher energy density and the achievement of full air liquefaction. Notably, PT-LAES does not depend on external sources of heat or cold and thus constitutes a stand-alone system. As a result, PT-LAES can also be viewed as an advanced LAES cycle with full liquefaction.

Carnot batteries↗

Retrofitting Holcim Ste. Genevieve Cement Plant with CO2 Capture Plant Using Air Liquide Cryocap™ FG Technology

The global cement manufacturing industry is a major contributor to carbon dioxide emissions. The International Energy Agency's "Net Zero Emissions by 2050 Scenario" identifies CCS as a major strategy for meeting that goal. This project is among the first attempts to transfer capture technology developed at coal-fired power plants to the cement industry. The main objective of the project is to execute and complete a front-end engineering and design (FEED) studies for commercial-scale, carbon capture projects that separates 95% of the total CO2 emissions at the Holcim (US) Ste. Genevieve cement manufacturing facility using Air Liquide’s Pressure Swing Adsorption system (PSA) assisted Cryocap™ technology. The Holcim Ste. Genevieve cement plant in Missouri, US, boasts one of the largest single cement production lines in the world, with a capacity of approximately 12,000 t/day. The plant currently uses traditional fuels, namely coal and petcoke. The captured CO2 will be pipeline and geological storage grade. The industrial host site emits approximately 3.0 million tonne CO2/yr. Air Liquide’s Cryocap™ technology has been developed over the last 18+ years for CO2 capture applications. It has been shown to be applicable to a variety of industrial applications (e.g., steel, cement, SMR, Fluidized Catalytic Crackers (FCCs)). Cryocap™ FG consists of a Pressure Swing Adsorption (PSA) unit coupled with a Cryogenic System. The PSA pre-concentrates the CO2 from the flue gas, while the cryogenic unit enables the CO2 purity to be increased to the desired level. The project team is led by the Prairie Research Institute at the University of Illinois at Urbana-Champaign. The tasks include: complete FEED study for retrofitting the industrial facility with a carbon capture system to support developing a detailed cost estimate; business case analysis outlining the anticipated revenue and credits if projects was built and operated; technoeconomic analysis (TEA) outlining how capture system achieves DOE capture goals; and life cycle (LCA) analysis demonstrating zero net carbon emissions. The FEED study was successfully completed. This includes completing the process basis of design; preliminary engineering; outside battery limits (OSBL) detailed engineering including a Zero Liquid Discharge (ZLD) wastewater treatment system; inside battery limits (ISBL) detailed engineering [1]. An overall project capital cost estimate within a -20%/+30% accuracy was developed. The major contributors to the Total Plant Cost (TPC), by system, are the costs associated with the Outside Battery Limit (OSBL) section of the plant which includes a new river water intake structure and a Zero Liquid Discharge (ZLD) system. By cost category, the major contributors to the TPC are equipment and subcontractor costs, followed closely by engineering, construction management, home office and contractor fees. The TEA has been created to reflect the findings of the project. It analyzes the economic performance of the Cryocap™ technology by reviewing the estimated capital costs, operating cost, and revenue. The Cost of Capture (COC) associated with the Cryocap™ technology for 95% CO2 capture, when considering NETL 2018 economic assumptions (42/58 debt/equity ratio, 5.15% interest on debt and 1.42% return on equity in real dollars) and 2022 economic assumptions (42/58 debt/equity ratio, 8.82% interest on debt and 4.90% return on equity in real dollars) was found to be much lower than that for the DOE-NETL’s base-line cases. The highest contributors to the COC are annualized capital expenditures (CAPEX) and electricity consumption which can be offset by using lower cost renewable sources. The LCA was conducted using OpenLCA which is an open-source software that is recommended by NETL. The database utilized for this study was a modified version of TRACI 2.1 (developed by the US. Environmental Protection Agency’s National Risk Management Research Laboratory and modified by NETL). The Cryocap™ FG technology does not consume fuels in significant quantities and does not utilize specialized chemical solvents subject to decomposition, such as those utilized in amine-based carbon capture systems. The Cryocap™ FG technology mainly utilizes electricity as its energy input; hence, its calculated emissions are mainly associated with the generation of electricity offsite and are dependent on the energy matrix of the grid at the time of project implementation. The water consumption impact of the Cryocap™ FG is mostly for makeup of the water lost by evaporation in the cooling tower; however, the carbon capture plant will be equipped with a ZLD system to avoid effluent streams and minimize water consumption. The successful construction and operation of this plant based on this study results will provide a means to demonstrate an economically attractive and transformational capture technology that can be used to retrofit existing plants and be deployed at new plants.

01 COAL, LIGNITE, AND PEAT↗

Carbon Capture from ArcelorMittal Hot Briquetted Iron Plant Using Air Liquide Cryocap™ FG Technology – FEED Study

The process of steel production is energy and carbon intensive with global average energy consumption of 5.5 MWh/tonne of steel and CO2 emission intensity of 1.83 tonne CO2/tonne of steel. The steel making process has inherent CO2 emissions from mineral conversion and is considered major contributors to the global carbon emissions. The steel industry is responsible for 8% of global carbon emissions. The main objective of this research project is to execute and complete a front-end engineering and design (FEED) study for a commercial-scale, carbon capture project that separates 95% of the total CO2 emissions at the ArcelorMittal’s Hot Briquetted Iron (HBI) plant in Portland, TX (Figure 1). The HBI is an ore-based metallic that is used as high-grade feedstock for high-quality steel via an Electric Arc Furnace (EAF) route. The HBI plant produces 2.0 million metric tonnes of high-quality HBI and emits approximately 1 million tonnes CO2/yr. The capture system is a Pressure Swing Adsorption (PSA) system assisted Cryocap™ FG technology (Figure 2). The captured CO2 will be pipeline grade and will be geologically stored in a facility within 10 miles of the CO2 source. The Host Site location in Corpus Christi, TX, is near hydrocarbon processing facilities and near Environmental Justice (EJ) and Qualified Opportunity Zone (QOZ) communities. Due to the location of the Host Site, the retrofit project offers the ability to demonstrate how a workforce focused on the fossil energy sector can be redirected to the clean- energy sector. The Air Liquide Cryocap™ capture technology is a proven technology and has been extensively examined for large industrial applications. It has been shown to be applicable to a variety of industrial applications including the steel industry. Cryocap™ FG (specific setup for Flue Gas application) consists of a Pressure Swing Adsorption (PSA) unit coupled with a Cryogenic System. The PSA pre-concentrates the CO2 from the flue gas, while the cryogenic unit enables the CO2 purity to be increased to the desired level. The scope of this study incorporates completing FEED study of the CO2 capture system which includes point-source CO2 capture and balance-of-plant; Business Case Analysis (BCA) outlining the current and projected volumes of the steel plant’s point sources of CO2 and the potential utilization of tax credits, including its projected revenue and duration; Life Cycle Analysis (LCA); Environmental Justice Analysis; Economic Revitalization and Job Creation Outcomes Analysis; and Workforce Readiness Plan. The plant design work was divided into two components: Inside Battery Limits (ISBL) and Outside Battery Limits (OSBL). The ISBL focuses on the capture system, while the OSBL focuses on the utility feeds and ducting from the plant to the capture system. Various design and engineering deliverables will be developed to define commodity quantities, equipment specifications, and labour effort required to execute the project. These FEED study deliverables will be prepared with the intent to develop an overall project capital cost estimate consistent with an AACE Class 3 estimate. The modular approach for the Cryocap™ FG that is being designed for this study integrates compression, PSA, and cryogenic “bricks” to achieve the desired CO2 capture rates. This carbon capture system integrates easily with the existing plant, thus reducing project costs and risks. It is also capable of managing impurities such as nitrogen oxides (NOx), sulfur oxides (SOx), mercury, hydrocarbons, and particulate matter. The capture system has a smaller footprint than amine-based systems. The two-step process uses PSA to preconcentrate the CO2 in the feedstream and then uses the cryogenic portion to purify and compress the resulting high purity CO2 product. This combination of purification and compression (i.e., process intensification) significantly reduces the CAPEX associated with use of a separate compressor commonly utilized for amine solvent-based systems. Successful completion of the FEED study will provide DOE with a detailed understanding of the costs for scaling up this proven capture technology for commercial applications at industrial facilities.

42 ENGINEERING↗

Precision Measurement of the Microwave Dielectric Loss of Sapphire in the Quantum Regime with Parts-per-Billion Sensitivity

Dielectric loss is known to limit state-of-the-art superconducting qubit lifetimes. Recent experiments imply upper bounds on bulk dielectric loss tangents on the order of 100 parts per billion but because these inferences are drawn from fully fabricated devices with many loss channels, these experiments do not definitely implicate or exonerate the dielectric. To resolve this ambiguity, we devise a measurement method capable of separating and resolving bulk dielectric loss with a sensitivity at the level of 5 ×10 –9 . The method, which we call the dielectric dipper, involves the in situ insertion of a dielectric sample into a high-quality microwave cavity mode. Smoothly varying the participation of the sample in the cavity mode enables a differential measurement of the dielectric loss tangent of the sample. The dielectric dipper can probe the low-power behavior of dielectrics at cryogenic temperatures and does so without the need for any lithographic process, enabling controlled comparisons of substrate materials and processing techniques. We demonstrate the method with measurements of sapphire grown by edge-defined film-fed growth (EFG) in comparison to high-grade sapphire grown by the heat-exchanger method (HEMEX). For EFG sapphire, we infer a bulk loss tangent of 63⁢(8) ×10 –9 and a substrate-air interface loss tangent of 15⁢(3) ×10 –4 (assuming a sample surface thickness of 3 nm). For a typical transmon, this bulk loss tangent would limit device quality factors to Q ≲20 ×10 6 , suggesting that bulk loss is likely the dominant loss mechanism in the longest-lived transmons on sapphire. We also demonstrate this method on HEMEX sapphire and bound its bulk loss tangent to be less than 19⁢(6) ×10 –9 . As this bound is about 3 times smaller than the bulk loss tangent of EFG sapphire, the use of HEMEX sapphire as a substrate would lift the bulk dielectric coherence limit of a typical transmon qubit to several milliseconds.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Industrial Carbon Capture from a Cement Facility Using the Cryocap FG Process (FE0032136)

The project's objective was to execute and complete front-end engineering and design (FEED) studies for commercial-scale, carbon capture projects that separate 95% of the total CO2 emissions at an industrial facility, producing at least 100,000 metric tonnes/year of CO2 for sequestration. The industrial facility selected is the Holcim (US) Ste. Genevieve cement manufacturing facility (the largest single kiln line in the world), while the carbon capture system selected is Pressure Swing Adsorption system (PSA) assisted Cryocap™ technology developed by Air Liquide. The impact of the project on Environmental Justice and the regional economy was also analyzed.

01 COAL, LIGNITE, AND PEAT↗

Industrial Carbon Capture from a Cement Facility Using the CryocapTM FG Process (2023 FECM/NETL Conference Proceeding)

The project's objective was to execute and complete front-end engineering and design (FEED) studies for commercial-scale, carbon capture projects that separate 95% of the total CO2 emissions at an industrial facility, producing at least 100,000 metric tonnes/year of CO2 for sequestration. The industrial facility selected is the Holcim (US) Ste. Genevieve cement manufacturing facility (the largest single kiln line in the world), while the carbon capture system selected is Pressure Swing Adsorption system (PSA) assisted Cryocap™ technology developed by Air Liquide. The impact of the project on Environmental Justice and the regional economy was also analyzed.

01 COAL, LIGNITE, AND PEAT↗

Cryogenic Carbon Capture™ (CCC) Status Report

The Cryogenic Carbon Capture™ (CCC) process separates CO2 from light gases in essentially any continuous process. CCC cools the gases to the frost or desublimation point of CO2 (-100 to -135 °C), separates and pressurizes the solids, and warms all streams to produce a CO2-depleted stream at ambient pressure and a pure (99+%) pressurized liquid CO2 stream typically to about 150 bar, both at ambient temperature. The process also recovers all gas moisture and most gas impurities less volatile than CO2 (NOx, SOx, Hg, PM, UHC, CCC, etc.) in separable streams. CCC nearly eliminates refrigeration energy for sensible temperature changes through heat integration. CCC does require energy to change the CO2 phase from a mixed vapor to a pressurized fluid, which represents the minimum energy required of any process for this separation. CCC uses additional energy for turbomachinery inefficiencies, heat losses, moisture removal and overall process pressure drop. Aside from these real-world energy demands, CCC operates near the minimum energy required to perform this gas separation by minimizing stream recycling. CCC compresses CO2 as a liquid, which is one of several reasons it costs about about half as much and consumes about half as much energy as an amine process when using flue gases with about 15% CO2. The process also has several major additional advantages, including (a) it is a bolt-on retrofit technology that does not need steam or any modification of existing equipment, (b) it recovers water and nearly all pollutants in addition to CO2 from the flue gas, (c) it enables highly efficient and cost effective energy storage at grid scale and on time scales of minutes, (d) it enables NG storage if the energy storage option is used, and (d) it has a small footprint and is minimally disruptive to existing plants, requiring only electrical power and a gas source to operate. Sustainable Energy Solutions (SES) has scaled this technology through several levels, the largest of which captures nominally 1 tonne of CO2/day and is called the skid system. Skid system field tests include utility-scale power plants, cement plants, heating plants, and other utility or industrial sites that burn natural gas, biomass, coal, shredded tires, municipal waste, and combinations of these fuels. These field tests produced 95-99% CO2 capture with CO2 purities of 99+% and initial CO2 contents that range from 4 to 28%. SES currently seeks to scale the system to merchant scale (10-80 tonnes of CO2 per day). In the process of doing so, SES has demonstrated the potential for CCC to contribute to energy storage and direct air capture in innovative and cost-effective ways. This presentation discusses the overall process and highlights results from field and in-house tests. These include (a) measured CO2 capture rates and operating conditions from in-house and field tests, and (b) predicted utility-scale costs and energy demands. This discussion also includes the application of the CCC technology to energy storage and direct air capture.

20 FOSSIL-FUELED POWER PLANTS↗

Overcoming Fundamental Limitations in Adsorbent Design: Alkene Adsorption by Non-porous Copper(I) Complexes

Purifying alkenes from alkanes requires cryogenic distillation. This consumes energy equivalent to countries of ca. 5 million people. Replacing distillation with adsorption processes would significantly increase energy efficiency. Trade-offs between kinetics, selectivity, capacity, and heat of adsorption have prevented production of an optimal adsorbent. Here, we report adsorbents that overcome these trade-offs. [Cu-Br] 3 and [Cu-H] 3 are air-stable trinuclear complexes that undergo reversible solid-state inter-molecular rearrangements to produce dinuclear [Cu-Br∙(alkene)] 2 and [Cu-H∙(alkene)] 2 . The reversible solid-state rearrangement, confirmed in situ using powder X-ray diffraction, allows adsorbent design trade-offs to be overcome, coupling low heat of adsorption (-10 to -17 kJ mol -1 alkene ), high alkene:alkane selectivity (47; 29), and uptake capacity (>2.5 molalkene mol -1 Cu3 ). Most remarkably, [Cu-H] 3 displays fast uptake and regenerates capacity within 10 minutes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Conformable, Composite Tank for Liquid Hydrogen Storage in Heavy-duty Ground Transportation

Raytheon Technologies Research Center (RTRC), with its partners, Argonne National Labs and University of Dayton Research Institute proposed to design and manufacture a conformable composite tank prototype to store liquid Hydrogen (LH2) for heavy-duty truck applications. A dual-wall tank concept was proposed where an outer shell covers and protects an inner pressure vessel that stores liquid hydrogen. The inner pressure vessel is liner-less and designed with a conformable concept, derived from prior RTRC ARPA-E program where multiple vessels are coalesced into one, maximizing space utilization and reducing surface area for heat leak. The gap between the dual wall is evacuated of air pressure, and filled with multi-layer insulation to minimize radiative heat transfer. Fiber reinforced composites were proposed for light-weighting and conformable shape manufacture. To minimize LH2 leakage, carbon nanotubes-infused composites were proposed, in addition to use of thin plies. The project was divided into two 18-month budget periods (BP), BP1 and BP2, separated by a Go/No-Go gate review. The high-level goal for BP1 was to demonstrate the feasibility of the overall approach, the tank design, material selection, and manufacturing methodology, build and test a prototype tank; and the goal for BP2 was to design and manufacture a conformal tank per DOE requirements (minimum 20 kg of LH2) and perform a successful test of the tank. The program was terminated about two-thirds of the way through BP1. The outcome of this program would have permitted long-haul trucks and construction vehicles to use liquid Hydrogen, reducing the emission of green-house gases. This technology is applicable to other transportation sectors as well.

08 HYDROGEN↗