Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “controller development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Advanced Reactor Control and Operations (ARCO): A University Research Facility for Developing Optimized Digital Control Rooms

The Advanced Reactor Control and Operations (ARCO) facility was constructed in January 2018 to serve as a test bed for advanced reactor control rooms and operator support systems. Since then, it has supported human-machine interface user experience research, fault detection and mitigation technology development, control room concept of operations development, and remote operations research. ARCO serves as the control room for the Compact Integral Effects Test (CIET) facility, which replicates the primary-side flow paths and thermal-hydraulic behavior of a fluoride-salt-cooled high-temperature reactor (FHR) using simulant fluids and scaling principles. New reactor designs feature different operating conditions and scenarios than those in existing reactors. ARCO supports the research and development of digital tools for operator communications, intuitive real-time data analysis, online health monitoring and prognostics, and control room cybersecurity. By integrating these different technologies, ARCO acts as a prototypical control system to iteratively develop methods and tools of operation in advanced small modular nuclear reactors. This paper describes the features of and challenges to operating advanced small modular reactors underlying the design basis for ARCO and its operator support systems.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of Control System Functional Capabilities within the IES Plug-and-Play Simulation Environment

The concept of an Integrated Energy System (IES) is meant to combine different energy technologies in synergistic ways to achieve a more secure and economical energy supply. The RAVEN-based HYBRID framework is used to find the optimal installed capacity and the optimal economical dispatch of each component of the IES. A new RAVEN (Risk Analysis Virtual ENvironment) plugin for grid and capacity optimization (HERON) has been developed for optimizing the production variables of the IES given the demand profile. Currently, only the limits that affect the production variables and their corresponding time rates of change are considered (explicit constraints). However, other variables are additionally subject to constraints, but the associated limits are not accounted for (implicit constraints). In particular, for the power dispatch problem, the optimization algorithm takes into account the limits on the electrical power output and the corresponding hourly power variations but does not consider other constraints on process variables whose response effects the service life of the IES. This report describes a scheme that allows accounting for implicit constraints without increasing the size of the optimization problem. The Reference Governor (RG) algorithm is traditionally used for enforcing state and control constraints by modifying the set-point trajectories supplied to the feedback regulators. In our application, the RG is coupled within an iterative loop with the HERON-power dispatcher to generate optimal trajectories that ensure the operational constraints are met. A data-driven procedure to derive a representation of the dynamics of the controlled system was developed. First, the variables that represented the state of the system are selected (PCA-based approach), and then state-space representation matrices are derived from the collected measurements (DMDc algorithm). A preliminary version of the developed workflow based on Linear Time Invariant matrices was assessed by adopting a two-unit test case. More sophisticated versions of this workflow foreseeing the on-line derivation of system matrices will be deployed in FY 2021. Finally, a “plug-and-play” library of controllers and state observers was developed in Dymola. Some aspects of the current configuration of the IES unit components, e.g., the encapsulation of the control schemes into dedicated blocks, are consistent with the “plug-and-play” philosophy. Other features, e.g., the system buses collecting the input and the output variables, are not. For this reason, once listed and described the limits of the current configuration, necessary modifications to the plant model interface are presented. As a test-case, the interfaces of the SES model in the RAVEN-based HYBRID framework were reworked accordingly, and two different control schemes were applied to the same plant model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integrated Framework of Vehicle Dynamics, Instabilities, Energy Models, and Sparse Flow Smoothing Controllers

This work presents an integrated framework of: vehicle dynamics models, with a particular attention to instabilities and traffic waves; vehicle energy models, with particular attention to accurate energy values for strongly unsteady driving profiles; and sparse Lagrangian controls via automated vehicles, with a focus on controls that can be executed via existing technology such as adaptive cruise control systems. This framework serves as a key building block in developing control strategies for human-in-the-loop traffic flow smoothing on real highways. In this contribution, we outline the fundamental merits of integrating vehicle dynamics and energy modeling into a single framework, and we demonstrate the energy impact of sparse flow smoothing controllers via simulation results.

Lee, Jonathan W.↗

Important powertrain dynamics for developing models for control of connected and automated electrified vehicles

Connected and Automated Vehicles (CAV) technology presents significant opportunities for energy saving in the transportation sector. CAV technology forecasts vehicle and powertrain power needs under various terrain, ambient, and traffic conditions. Integration of the CAV technology in Hybrid Electric Vehicles (HEVs) provides the opportunity for optimal vehicle operation. Indeed, Hybrid Electric Vehicle powertrains present high degrees of flexibility and possibility for choosing optimum powertrain modes based on the predicted traction power needs. In modeling complex CAV powertrain dynamics, the modeler needs to consider short-time scale powertrain dynamics, such as engine transients, and hysteresis of mode-switching for a multi-mode HEV. Therefore, the powertrain dynamics essential for developing powertrain controllers for a class of connected HEVs is presented. To this end, control-oriented powertrain dynamic models for a test vehicle consisting of full electric, hybrid, and conventional engine operating modes are developed. The resulting powertrain model can forecast vehicle traction torque and energy consumption for the specified prediction horizon of the test vehicle. The model considers different operating modes and associated energy penalty terms for mode switching. Thus, the vehicle controller can determine the optimum powertrain mode, torque, and speed for forecasted vehicle operation via utilizing connectivity data. The powertrain model is validated against the experimental data and shows prediction error of less than 5% for predicting vehicle energy consumption. The model is used to create energy penalty maps that can be used for CAV control, for example fuel penalty map for engine torque changes (10–40 Nm) at each engine speed. The results of model-based optimization show optimum switching delays ranging from 0.4 to 1.4 s to avoid hysteresis in mode switching.

Engineering↗

Dynamic Model of a supercritical CO2 10MW Recompression Closed Brayton Cycle

This model of the 10MW recompression closed Brayton cycle (RCBC) was developed in conjunction with the DOE’s Supercritical Transformational Electric Power (STEP) project. A high-fidelity dynamic model was used extensively to study the dynamic characteristics of the cycle and develop the process control architecture and strategies for start-up and shutdown procedures. This version of the model has been simplified from the original version to be more accessible for a variety of applications and research. The controllers developed for the original model have been maintained for this version and tuned to give a similar performance to the original model. This model can be used to perform similar studies as those performed in Liese et al (2020). The overall cycle performance will not be identical but will perform similarly.

Controls,Power Cycles,Process Systems Engineering,↗

Voltage Control Strategy for Energy Storage System in Sustainable Distribution System Operation

Due to the increasing penetration of distributed energy resources (DERs) required for the sustainable distribution system, new voltage control strategy is needed by utilities. Traditional voltage control strategy can not support the increasing number of DERs in a coordinated and scalable manner to meet the operational voltage regulation requirement. Supported by the power electronics converter, the energy storage system can provide fast, smooth, and flexible voltage control services. In this paper, an effective and easy to implement sensitivity-based voltage control strategy is developed for the energy storage system. The developed control strategy is validated using an industrial feeder data in Northwest Washington. The proposed strategy can mitigate the voltage unbalance issue, improve the voltage profile, and correct power factors while supporting sustainable distribution system operation.

Zhang, Yue (ORCID:0000000241469716)↗

Remote Hardware-in-the-Loop Approach for Microgrid Controller Evaluation

Utilities have been installing microgrids because of the increased resilience and reliability advantages they may provide to the distribution system. A microgrid controller is a critical component in microgrids. It is of great benefit to derisk the installation of microgrid controllers before field deployment. Hardware-in-the-loop (HIL) testing is used by controller developers and utilities to evaluate the controllers under stressful conditions. In this work, a microgrid control function developed by the Synchrophasor Grid Monitoring and Automation (SyGMA) laboratory at the University of California, San Diego is tested in a remote HIL (RHIL) setup. The digital real-time simulation of the detailed microgrid system was operated at the National Renewable Energy Laboratory's Energy Systems Integration Facility. Under such RHIL setup, successful controller operation is contingent on understanding and characterizing the communications channel and in particular network latencies. The novelty of this paper is the proposed use of a RHIL setup that leverages existing power system communications protocols to evaluate the controller in conjunction with the simulation capabilities of a remote facility. The work presented here will provide the complete setup of the HIL evaluation platform, the details of the communications protocols used by the setup for data transfer between the two organizations, test cases developed to evaluate the controller, and the results from the experiments.

controller hardware-in-the-loop↗

Remote Hardware-in-the-Loop Approach for Microgrid Controller Evaluation

Utilities have been installing microgrids because of the increased resilience and reliability advantages they may provide to the distribution system. A microgrid controller is a critical component in microgrids. It is of great benefit to derisk the installation of microgrid controllers before field deployment. Hardware-in-the-loop (HIL) testing is used by controller developers and utilities to evaluate the controllers under stressful conditions. In this work, a microgrid control function developed by the Synchrophasor Grid Monitoring and Automation (SyGMA) laboratory at the University of California, San Diego is tested in a remote HIL (RHIL) setup. The digital real-time simulation of the detailed microgrid system was operated at the National Renewable Energy Laboratory's Energy Systems Integration Facility. Under such RHIL setup, successful controller operation is contingent on understanding and characterizing the communications channel and in particular network latencies. The novelty of this paper is the proposed use of a RHIL setup that leverages existing power system communications protocols to evaluate the controller in conjunction with the simulation capabilities of a remote facility. The work presented here will provide the complete setup of the HIL evaluation platform, the details of the communications protocols used by the setup for data transfer between the two organizations, test cases developed to evaluate the controller, and the results from the experiments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Remote Hardware-in-the-Loop Approach for Microgrid Controller Evaluation: Preprint

Utilities have been installing microgrids due to the advancements in the distributed energy resources technologies. Microgrids also improve the resiliency of the system due to their capability to isolate themselves from the grid and run in islanded mode of operation. Microgrid controllers are management systems that can run the microgrids under varied operating condition and enable the smooth operation of microgrids under various system conditions. It is of high value to de-risk the installation of such controllers. Hardware-in-the-loop evaluation is used by controller developers and utilities to evaluate the controllers under stressful conditions to understand the performance and to understand the necessary improvements to the microgrid controller. In this research work, the team has leveraged the existing infrastructure of real-time simulation at the Energy Systems Integration Facility (ESIF) and the capability of the microgrid controller to control assets over the Internet Protocol (IP) to evaluate a university developed microgrid controller in an efficient and cost-effective manner. The full paper will provide the complete setup, the experimental use cases and the results. In this abstract, one use case will be expalined, and the results from the use case is provided.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Spallation Neutron Source Proton Power Upgrade Low-Level RF Control System Development

The Proton Power Upgrade (PPU) Project is approved for the Spallation Neutron Source at Oak Ridge National Laboratory and will double the proton beam power capability from 1.4 MW to 2.8 MW with 2 MW beam power available to the first target station. A second target station is planned and will utilize the remaining beam power in the future. The proton power increase will be supported with the addition of twenty-eight new superconducting cavities powered by 700 kW peak power klystrons to increase beam energy while increases to the beam current will be done with a combination of existing RF margin, and DTL HPRF upgrades. The original low-level RF control system has proven to be reliable over the past 15 years of operations, but obsolescence issues mandate a replacement system be developed for the PPU project. The replacement system is realized in a µTCA.4 platform using a combination of commercial off-the-shelf boards and custom hardware to support the requirements of PPU. This paper presents the prototype hardware, firmware, and software development activities along with preliminary testing results of the new system.

Crofford, Mark↗

Demonstrate FARM supervisory capabilities for a thermal energy storage problem for the DETAIL facility: IES Simulation Ecosystem Control System Development

The goal of the power dispatch problem for an Integrated Energy System (IES) is to adjust the power output and the heat flow of each component to maximize the profitability of the whole unit. Facilities that can integrate real-time digital signals, mock nuclear power, thermal energy storage and industrial heat use via high-temperature electrolysis were constructed at INL to support the research activities. The Dynamic Energy Technology and Integration Laboratory (DETAIL) houses the Microreactor Agile Non-nuclear Experimental Test Bed (MAGNET) and the Thermal Energy Distribution System (TEDS). In this report, the hierarchical control system architecture proposed in June 2023 milestone for the flexible operation of DETAIL facility is finalized and demonstrated. A brief description of the components and the corresponding Dymola models from the HYRBID repository is first provided. Then, the current control strategy is presented. In particular, the approach for generating the set-point trajectories to be fed to the PI controllers is analyzed, and its limits were identified. To preserve safe operation over both long-time and real-time horizons, the integration of a Supervisory Control layer embedding a modified version of FARM (Feasible Actuator Range Modifier) module is proposed. FARM is a component of the RAVEN-based FORCE framework designed to support HERON module at optimizing the operation of IES units. The proposed control system for DETAIL foresees FARM to be applied twice, i.e., the original version (“FARM-Validator”) aiding the solution of the power dispatch problem, and a modified version (“FARM-Supervisory”) coordinating the PID controllers. Despite the kernel of the two modules is the same, their tasks are quite different. The former intervenes at the beginning of each hour to prevent constraint violations over long time periods, the latter addresses real-time control tasks and monitors the response of constrained variables at a much finer time resolution. A tentative procedure for training the embedded Digital Twins with the experimental data is also proposed. Finally, the capabilities of the designed architecture and the impact of the added Supervisory Control layer are demonstrated by simulating a representative power dispatch scenario.

25 ENERGY STORAGE↗

Strategy to Develop a Control Scheme for Core Thermal Performance Optimization

This report outlines a three-year research plan for optimizing reactor core thermal performance through use of a Digital Twin (DT) model and a set of neutron detectors to correspondingly adapt the reactor control strategy. It identifies reactor features and achievable neutron measurements that factor into this optimization task. It considers spatial effects that are important and how they can be managed by a real-time algorithm that controls reactivity actuators. The report presents a set of tasks, along with corresponding methods, for accomplishing this objective. The final task in this set is to validate the combined optimization procedure in the Purdue University’s PUR-1 reactor, for which we have an agreement of understanding. Additionally, we describe an alternative approach for overcoming some of the limitations inherent in the above approach, which includes the computational costs of high-fidelity simulations and achievable integration of neutron measurements into the DT. The proposed algorithms lower the technology readiness level (TRL) of the overall approach as some additional analysis and the development of a new neutron detector concept are necessary. In particular, a sensor measuring the gradient of the neutron flux is required, and the prototype is expected to be validated in the PUR-1 reactor. The potential benefits and the opportunity to significantly push forward the state-of-the-art make this approach worthy of further exploration in the upcoming years.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Integrate FARM with PID controllers: IES Simulation Ecosystem Control System Development

The FARM (Feasible Actuator Range Modifier) software module is a component of the RAVEN-based FORCE framework for analysis of Integrated Energy Systems (IES). FARM was designed to support the HERON software module in the solution of the optimal dispatch problem for IES units. As the result of HERON-FARM dispatch simulation, the set-point trajectories are optimized to meet constraints on both the production variables (i.e., the variables to be optimized such as the electrical power, the hydrogen production rate, etc.) and the process variables tied to the service life of equipment (e.g., steam flowrate, vessel pressure, turbine firing temperature, etc.) at a coarse time resolution (every 10 or 100 seconds) over long time horizons (several days or weeks). In case the operational constraints need to be met at finer time resolution, the computational burden of HERON-FARM would linearly increase with the sampling rate, and sub-optimal solutions might be obtained. System responses characterized by overshoots and damped oscillations temporarily violating the imposed constraints might occur during abrupt power transients. In this report, a hierarchical control system architecture for the operation of the Dynamic Energy Technology and Integration Laboratory (DETAIL) facility constructed at INL was proposed. First, the preliminary studies on the proposed control strategy for operating the facility and the designed PI controllers were reviewed. In particular, the current approach for generating the set-point trajectories was studied, and its limits were identified. To this aim, the inclusion of a Supervisory Control layer embedding a modified version of the FARM algorithm for preserving the system safe operation over both long and real-time horizons was proposed. In this way, FARM would be applied twice, i.e., the original version (“FARM Validator”) aiding the solution of the power dispatch problem, and the modified version (“FARM Supervisory” coordinating the PI controllers to address the real-time control tasks. Despite the kernel of the two modules is the same algorithm, their roles, tasks, and capabilities are quite different. A detailed description of the role of FARM at addressing low-level control tasks is provided, along with tentative operational procedures for training the models embedded into the algorithm by using the collected experimental data.

42 ENGINEERING↗

Developing a Control Strategy for Minimum Airflow Setting Considering CO2 Level and Energy Consumption in a Variable Air Volume System

In an office building equipped with a Variable Air Volume (VAV) system, this paper introduces a novel method for controlling the minimum supply airflow fraction in each zone’s VAV box, having a capability to consider indoor CO2 level and energy consumption. The EnergyPlus simulation using the medium office prototype model was employed, which evaluated the performance of the energy and CO2 concentration for five VAV box airflow control strategies. The paper focuses on CO2 concentration-based airflow control method and compares it with other four methods including conventional single-max, reduced minimum single-max, demand-controlled ventilation(DCV), and dualmax control methods according to guidelines and common practices. The newly proposed control strategy directly correlates the minimum airflow fraction to CO2 concentration. A general trend emerged when comparing CO2 concentrations—lower minimum airflow fractions were associated with higher concentrations. The proposed control method effectively maintained low CO2 concentrations and enabled a lower airflow fraction contributing to energy consumption reduction. It was confirmed that heating energy consumption in climate zone 4A, 5B, and 6A showed a maximum saving of approximately 30% compared to the conventional single-max and dual max control strategies. It was found that cooling energy consumption in climate zone 4A and 6A can achieve a maximum saving of approximately 10% compared to the conventional control strategies. The proposed CO2 concentration-based control logic is promising as it not only improves the indoor air quality lowering the CO2 concentration in the occupied spaces, but also contributes to HVAC energy savings.

Lee, Jong Man↗

Bacterial and fungal composition and exometabolites control the development and persistence of soil water repellency

Soil water repellency (SWR), the reduced affinity of soil for water, is a phenomenon that affects soils globally. With worsening climate change, SWR is expected to increase emphasizing the need to understand the mechanisms driving SWR development and persistence. The importance of the soil microbes in SWR has been postulated for decades, but limited research has been conducted into whole-community interactions and the role of community metabolic activity. To address this gap in knowledge, we investigated the direct effect of microbial community composition, activity, and diversity, as well as their associated metabolites on the development and persistence of SWR by inoculating microcosms containing model soils with 15 different microbial communities and quantified respiration and SWR over time. Six communities that consistently produced either a hydrophobic or hydrophilic phenotype were characterized using metagenomics and metabolomics to determine the impact of microbial and metabolite composition and diversity on SWR. We identified several bacterial genera with significant changes in abundance between SWR phenotypes including Nocardiopsis and Kocuria in hydrophilic and Streptomyces and Cutibacterium in hydrophobic. We discovered that hydrophilic communities were more positively connected when compared to hydrophobic communities, which could be due to an increase in defense mechanism genes. Additionally, we identified specific metabolites associated with hydrophilic and hydrophobic phenotypes including an increase in the osmolyte ectoine in hydrophilic and an increase in plant-derived decomposition products in hydrophobic communities. Finally, our research suggests that fungi, previously thought to cause hydrophobicity, may actually contribute to hydrophilicity through their preferential consumption of hydrophobic compounds.

54 ENVIRONMENTAL SCIENCES↗

Multibody for Everybody (M4E) - A Linearization Approach to Enable Frequency Domain Analysis, Time Integration and Control Co-Design

1.1 Background/Objectives: Marine energy represents a promising yet underexploited source of power. To increase the harvested power, significant efforts have been made to improve wave energy converter (WEC) modeling capabilities and optimize power take-off (PTO) performance; however, these efforts have often treated WEC dynamics, PTO design, and controller development sequentially. In contrast, control co-design (CCD) is emerging as a promising strategy to address these issues directly, creating a growing need for fast analysis tools suitable for repeated simulation and parametric studies [1]. To support this need, this work presents the Multibody for Everybody (M4E) [2] linearization module, which employs a symbolic toolbox to provide deeper insight of WEC design parameters. The objective is to demonstrate that a minimal-coordinate linearization of articulated WEC dynamics can provide accurate wave response predictions and substantial computational savings relative to nonlinear time-domain simulation, while preserving compatibility with broader wave-energy analysis workflows, enabling CCD. 1.2 Approach/Activities: The proposed approach linearizes the equations of motion, generated by M4E, in minimal coordinates about a selected operating point and combines the resulting system with frequencydomain hydrodynamic terms to incorporate the reduced mass, damping, stiffness, and forcing operators. The linearized model is used for both impedance-based response amplitude operator (RAO) prediction and rapid regular-wave time integration. The methodology is demonstrated on a single-flap device and a FOSWEC configuration, with linearized M4E responses compared against the corresponding nonlinear M4E simulations and WEC-Sim results. Regular-wave time histories, RAO trends, and runtime differences are assessed. The framework is also compatible with broader wave-energy workflows, including coupling to WecOptTool, although that capability is not the focus of this work [3]. 1.3 Results/Lessons: The linearized M4E model reproduces key regularwave response characteristics such as integration and Response Amplitude over multiple frequencies. This module matches nonlinear M4E and WEC-Sim results while substantially reducing integration cost. Thus, the proposed framework can serve as a rapid analysis layer for articulated WEC design, parameter studies, and controls-oriented workflows. The analysis is most appropriate in the near-equilibrium regime, about the linearization point.

16 TIDAL AND WAVE POWER↗

Theoretical Development of Controller Transfer applied to Dynamical Systems

Data-driven control strategies suffer from the necessity of training and its associated computational time and cost. This motivates the continuous increase of popularity of transfer learning based methods. In this paper, we have investigated transfer learning in the context of controller for dynamical systems. First, we have derived conditions under which controller can be transferred between two linear dynamical systems. Furthermore, we have introduced a novel algorithm to design the transferable and non-transferable control components for linear systems. Secondly, we have derived conditions under which a stabilizing controller can be transferred between two different nonlinear dynamical systems. Furthermore, we have used the notion of zero dynamics to transform the nonlinear dynamics into global normal form, to derive the transferability conditions on the controller. Finally, we have numerically evaluated the performance of our transfer learning based methods for two sets of example linear and nonlinear dynamical systems.

Chakraborty, Indrasis↗