Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “channel calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

TOPEX/POSEIDON microwave radiometer performance and in-flight calibration

Results of the in-flight calibration and performance evaluation campaign for the TOPEX/POSEIDON microwave radiometer (TMR) are presented. Intercomparisons are made between TMR and various sources of ground truth, including ground-based microwave water vapor radiometers, radiosondes, global climatological models, special sensor microwave imager data over the Amazon rain forest, and models of clear, calm, subpolar ocean regions. After correction for preflight errors in the processing of thermal/vacuum data, relative channel offsets in the open ocean TMR brightness temperatures were noted at the approximately = 1 K level for the three TMR frequencies. Larger absolute offsets of 6-9 K over the rain forest indicated a approximately = 5% gain error in the three channel calibrations. This was corrected by adjusting the antenna pattern correction (APC) algorithm. AS 10% scale error in the TMR path delay estimates, relative to coincident radiosondes, was corrected in part by the APC adjustment and in part by a 5% modification to the value assumed for the 22.235 FGHz water vapor line strength in the path delay retrieval algorithm. After all in-flight corrections to the calibration, TMR global retrieval accuracy for the wet tropospheric range correction is estimated at 1.1 cm root mean square (RMS) with consistent peformance under clear, cloudy, and windy conditions.

Ruf, C. S.↗

AMSU-A Tropical Cyclone Maximum Sustained Winds and Web Site

The Advanced Microwave Sounding Unit (AMSU)-A instruments on the NOAA-15 and NOAA-16 satellites provide information on the warm cores of tropical cyclones from oxygen channel brightness temperature (Tb) measurements near 55 GHz. With appropriate assumptions, cyclone-scale Tb gradients can be directly related to middle-to-lower tropospheric height gradients. We have developed a method for diagnosis of maximum sustained winds (Vmax) from radially averaged Tb gradients in several of the AMSU channels. Calibration of the method with recon-based (or other in situ) winds results in better agreement than with Dvorak wind estimates. Gradient wind theory shows that the warm core Tb gradient signal increases non-linearly with wind speed, making microwave temperature sounders useful for diagnosing high wind speeds, but at the expense of a minimum useful detection limit of about 40 knots. It is found that accurate wind diagnoses depend upon (1) accounting for hydrometeor effects in the AMSU channels, and (2) maximizing signal-to-noise, since the 50 km resolution data cannot fully resolve the temperature gradients in the Vmax region, typically 10-20 km in scale. AMSU imagery and max diagnoses from specific hurricanes will be shown, including independent tests from the 2000 hurricane season.

Spencer, Roy↗

Measurement of CP asymmetries in ${D}_{(s)}^{+}\to \eta {\pi}^{+}$ and ${D}_{(s)}^{+}\to {\eta}^{\prime }{\pi}^{+}$ decays

Searches for CP violation in the decays ${D}_{(s)}^{+}\to \eta {\pi}^{+}$ and ${D}_{(s)}^{+}\to {\eta}^{\prime }{\pi}^{+}$ are performed using pp collision data corresponding to 6 fb –1 of integrated luminosity collected by the LHCb experiment. The calibration channels ${D}_{(s)}^{+}\to \phi {\pi}^{+}$ are used to remove production and detection asymmetries. The resulting CP-violating asymmetries are $\mathcal{A}^{CP} = (D^+ \to ηπ^+) = (0.34 ± 0.66 ± 0.16 ± 0.05)$ %, $\mathcal{A}^{CP} = (D^+_s \to ηπ^+) = (0.32 ± 0.51 ± 0.12)$ %, $\mathcal{A}^{CP} = (D^+ \to η'π^+) = (0.49 ± 0.18 ± 0.06 ± 0.05)$ %, $\mathcal{A}^{CP} = (D^+_s \to η'π^+) = (0.01 ± 0.12 ± 0.08)$ %, where the first uncertainty is statistical, the second is systematic and the third, relevant for the D + channels, is due to the uncertainty on ${\mathcal{A}}^{CP}=\left({D}^{+}\to \phi {\pi}^{+}\right)$. These measurements, currently the most precise for three of the four channels considered, are consistent with the absence of CP violation. A combination of these results with previous LHCb measurements is presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optically multiplexed neutron time-of-flight technique for inertial confinement fusion

Neutron time-of-flight (nTOF) detectors are crucial in diagnosing the performance of inertial confinement fusion (ICF) experiments, which implode targets of deuterium–tritium fuel to achieve thermonuclear conditions. These detectors utilize the fusion neutron energy spectrum to extract key measurements, including the hotspot ion temperature and fuel areal density. Previous work [Danly et al., Rev. Sci. Instrum. 94, 043502 (2023)] has demonstrated adding 1D spatial resolution to an nTOF-like detector using a neutron aperture and streak camera to measure the ion temperature profile of an ICF implosion. By contrast, the study presented herein explores modifying the 1D detector to use a fast photomultiplier tube (PMT) to validate the design of a 2D spatially resolved instrument based on reconstruction from 1D profiles. The modification would collect time-of-flight traces from separate scintillators in an imaging array with one PMT using optical fibers of varying lengths to time-multiplex the signals. This technique has been demonstrated in ride-along experiments on the OMEGA laser with 20 fiber-coupled scintillator channels connected to a Photek PMT210. Results provide constraints on the fiber lengths and PMT gating requirements to promote pulse fidelity throughout all channels. Calibration of the detector to fixed nTOFs can provide a preliminary estimate of the instrument response function (IRF), although measurement of the IRF is currently under way. These results suggest that nTOF signals can potentially be time-multiplexed with fibers so long as the design is strategic to mitigate signal-to-noise reduction, modal dispersion, and charge build-up in the PMT, which has implications beyond ion temperature imaging.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First-ever deployment of a SiPM-on-tile calorimeter in a collider: a parasitic test with 200 GeV p p collisions at RHIC.

We describe the testing of a prototype SiPM-on-tile iron-scintillator calorimeter at the Relativistic Heavy Ion Collider (RHIC) during its 200 GeV p p run in 2024. The prototype, measuring 20 × 20 cm 2 and 24 radiation lengths in depth, was positioned in the STAR experimental hall, approximately 8 m from the interaction point and 65 cm from the beam line, covering a pseudorapidity range of about 3.1 < η < 3.4. By using the dark current of a reference SiPM as a radiation monitor, we estimate that the prototype was exposed to a fluence of about 10 10 1-MeV n eq /cm 2 . Channel-by-channel calibration was performed in a data-driven way with the signature from minimum-ionizing particles during beam-on conditions. AGeant4 detector simulation, with inputs from thePythia8 event generator, describes measurements of energy spectra and hit multiplicities reasonably well. These results mark the first deployment, commissioning, calibration, and long-term operation of a SiPM-on-tile calorimeter in a collider environment. This experimental campaign will guide detector designs and operational strategies for the ePIC detector at the future EIC, as well as other applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ICE/ISEE plasma wave data analysis

The interval reported on, from Jan. 1990 to Dec. 1991, has been one of continued processing and archiving of ICE plasma wave (pw) data and transition from analysis of ISEE 3 and ICE cometary data to ICE data taken along its cruise trajectory, where coronal mass ejections are the focus of attention. We have continued to examine with great interest the last year of ISEE 3's precomet phase, when it spent considerable time far downwind from Earth, recording conditions upstream, downstream, and across the very weak, distant flank bow shock. Among other motivations was the apparent similarity of some shock and post shock structures to the signatures of the bow wave surrounding comet Giacobini-Zinner, whose ICE-phase data was revisited. While pursuing detailed, second-order scientific inquiries still pending from the late ISEE 3 recordings, we have also sought to position ourselves for study of CME's by instituting a data processing format new to the ISEE 3/ICE pw detector. Processed detector output has always been summarized and archived in 24-hour segments, with all pw channels individually plotted and stacked one above the next down in frequency, with each channel calibrated separately to keep all data patterns equally visible in the plots, regardless of gross differences in energy content at the various frequencies. Since CME's, with their preceding and following solar wind plasmas, can take more than one day to pass by the spacecraft, a more condensed synoptic view of the pw data is required to identify, let alone assess, CME characteristics than has been afforded by the traditional routines. This requirement is addressed in a major new processing initiative in the past two years. Besides our own ongoing and fresh investigations, we have cooperated, within our resources, with studies conducted extramurally by distant colleagues irrespective of the phase of the ISEE 3/ICE mission under scrutiny. The remainder of this report summarizes our processing activities, our investigations, both internal and cooperative, our scientific results, and our publication activity.

Greenstadt, E. W.↗

Analysis of the Performance Characteristics of the Five-Channel Microtops II Sun Photometer for Measuring Aerosol Optical Thickness and Precipitable Water Vapor

Five Microtops II sun photometers were studied in detail at the NASA Goddard Space Flight Center (GSFC) to determine their performance in measuring aerosol optical thickness (AOT or Tau(sub alphalambda) and precipitable column water vapor (W). Each derives Tau(sub alphalambda) from measured signals at four wavelengths lambda (340, 440, 675, and 870 nm), and W from the 936 nm signal measurements. Accuracy of Tau(sub alphalambda) and W determination depends on the reliability of the relevant channel calibration coefficient (V(sub 0)). Relative calibration by transfer of parameters from a more accurate sun photometer (such as the Mauna-Loa-calibrated AERONET master sun photometer at GSFC) is more reliable than Langley calibration performed at GSFC. It was found that the factory-determined value of the instrument constant for the 936 nm filter (k= 0.7847) used in the Microtops' internal algorithm is unrealistic, causing large errors in V(sub 0(936)), Tau(sub alpha936), and W. Thus, when applied for transfer calibration at GSFC, whereas the random variation of V(aub 0) at 340 to 870 nm is quite small, with coefficients of variation (CV) in the range of 0 to 2.4%, at 936 nm the CV goes up to 19%. Also, the systematic temporal variation of V(sub 0) at 340 to 870 nm is very slow, while at 936 nm it is large and exhibits a very high dependence on W. The algorithm also computes Tau(sub alpha936) as 0.91Tau(sub alpha870), which is highly simplistic. Therefore, it is recommended to determine Tau(sub alpha936) by logarithmic extrapolation from Tau(sub alpha675) and Tau(sub alpha 870. From the operational standpoint of the Microtops, apart from errors that may result from unperceived cloud contamination, the main sources of error include inaccurate pointing to the Sun, neglecting to clean the front quartz window, and neglecting to calibrate correctly. If these three issues are adequately taken care of, the Microtops can be quite accurate and stable, with root mean square (rms) differences between corresponding retrievals from clean calibrated Microtops and the AERONET sun photometer being about +/-0.02 at 340 nm, decreasing down to about +/-0.01 at 870 nm.

Ichoku, Charles↗

Oxygen Spectroscopy Laser Sounding Instrument for Remote Sensing of Atmospheric Pressure

We report on the progress of an Oxygen spectroscopy laser sounding instrument designed as a calibration channel for a carbon dioxide (CO2) laser sounding instrument. We have developed a pulsed, frequency-doubled, fiber laser transmitter for use in an oxygen instrument. The instrument concept uses the pressure broadening of spectroscopic lines of the diatomic oxygen A-band to deduce atmospheric pressure. There are many uses for this measurement but we are developing it primarily to make a measurement of the dry mixing ratio of CO2. The CO2 measurement can be affected by changes in atmospheric properties such as humidity, temperature and pressure. To remove these variances requires measuring a stable, well-mixed gas like Oxygen. We will report on the basic theory behind the instrument, measurements made at a test site at Goddard, review the current state of the instrument technologies and the necessary steps to bring them to space readiness, and review the current state of the instrument development.

Stephen Mark A.↗

Comparison of CERES-MODIS Stratus Cloud Properties with Ground-Based Measurements at the DOE ARM Southern Great Plains Site

Overcast stratus cloud properties derived for the Clouds and the Earth's Radiant Energy system (CERES) Project using Terra and Aqua Moderate Resolution Imaging Spectroradiometer (MODIS) data are compared with observations taken at the Atmospheric Radiation Measurement (ARM) Southern Great Plains site from March 2000 through December 2004. Retrievals from ARM surface-based data were averaged over a 1-hour interval centered at the time of each satellite overpass, and the CERES-MODIS cloud properties were averaged within a 30-km x 30 km box centered on the ARM SGP site. Two datasets were analyzed: all of the data (ALL) which include multilayered, single-layered, and slightly broken stratus decks and a subset, single-layered unbroken decks (SL). The CERES-MODIS effective cloud heights were determined from effective cloud temperature using a lapse rate method with the surface temperature specified as the 24-h mean surface air temperature. For SL stratus, they are, on average, within the ARM radar-lidar estimated cloud boundaries and are 0.534 +/- 0.542 km and 0.108 +/- 0.480 km lower than the cloud physical tops and centers, respectively, and are comparable for day and night observations. The mean differences and standard deviations are slightly larger for ALL data, but not statistically different to those of SL data. The MODIS-derived effective cloud temperatures are 2.7 +/- 2.4 K less than the surface-observed SL cloud center temperatures with very high correlations (0.86-0.97). Variations in the height differences are mainly caused by uncertainties in the surface air temperatures, lapse rates, and cloud-top height variability. The biases are mainly the result of the differences between effective and physical cloud top, which are governed by cloud liquid water content and viewing zenith angle, and the selected lapse rate, -7.1 K km(exp -1). Based on a total of 43 samples, the means and standard deviations of the differences between the daytime Terra and surface retrievals of effective radius r(sub e), optical depth, and liquid water path for SL stratu are 0.1 +/- 1.9 micrometers (1.2 +/- 23.5%), -1.3 +/- 9.5 (-3.6 +/-26.2%), and 0.6 +/- 49.9 gm (exp -2) (0.3 +/- 27%), respectively, while the corresponding correlation coefficients are 0.44, 0.87, and 0.89. For Aqua, they are 0.2 +/- 1.9 micrometers (2.5 +/- 23.4%), 2.5 +/- 7.8 (7.8 +/- 24.3%), and 28.1 +/- 52.7 gm (exp -2) (17.2 +/- 32.2%), as well as 0.35, 0.96, and 0.93 from a total of 21 cases. The results for ALL cases are comparable. Although a bias in R(sub e) was expected because the satellite retrieval of effective radius only represents the top of the cloud, the surface-based radar retrievals revealed that the vertical profile of r(sub e) is highly variable with smaller droplets occurring at cloud top in some cases. The larger bias in optical depth and liquid water path for Aqua is due, at least partially, to differences in the Terra and Aqua MODIS visible channel calibrations. methods for improving the cloud-top height and microphysical property retrievals are suggested.

Dong, Xiquan↗

High-Speed, High-Resolution Time-to-Digital Conversion

This innovation is a series of time-tag pulses from a photomultiplier tube, featuring short time interval between pulses (e.g., 2.5 ns). Using the previous art, dead time between pulses is too long, or too much hardware is required, including a very-high-speed demultiplexer. A faster method is needed. The goal of this work is to provide circuits to time-tag pulses that arrive at a high rate using the hardwired logic in an FPGA - specifically the carry chain - to create what is (in effect) an analog delay line. High-speed pulses travel down the chain in a "wave." For instance, a pulse train has been demonstrated from a 1- GHz source reliably traveling down the carry chain. The size of the carry chain is over 10 ns in the time domain. Thus, multiple pulses will travel down the carry chain in a wave simultaneously. A register clocked by a low-skew clock takes a "snapshot" of the wave. Relatively simple logic can extract the pulses from the snapshot picture by detecting the transitions between logic states. The propagation delay of CMOS (complementary metal oxide semiconductor) logic circuits will differ and/or change as a result of temperature, voltage, age, radiation, and manufacturing variances. The time-to-digital conversion circuits can be calibrated with test signals, or the changes can be nulled by a separate on-die calibration channel, in a closed loop circuit.

Katz, Richard↗

Utilizing the Precessing Orbit of TRMM to Produce Hourly Corrections of Geostationary Infrared Imager Data with the VIRS Sensor

Accurate characterization of the Earth's radiant energy is critical for many climate monitoring and weather forecasting applications. For example, groups at the NASA Langley Research Center rely on stable visible- and infrared-channel calibrations in order to understand the temporal/spatial distribution of hazardous storms, as determined from an automated overshooting convective top detection algorithm. Therefore, in order to facilitate reliable, climate-quality retrievals, it is important that consistent calibration coefficients across satellite platforms are made available to the remote sensing community, and that calibration anomalies are recognized and mitigated. One such anomaly is the infrared imager brightness temperature (BT) drift that occurs for some Geostationary Earth Orbit satellite (GEOsat) instruments near local midnight. Currently the Global Space-Based Inter-Calibration System (GSICS) community uses the hyperspectral Infrared Atmospheric Sounding Interferometer (IASI) sensor as a common reference to uniformly calibrate GEOsat IR imagers. However, the combination of IASI, which has a 21:30 local equator crossing time (LECT), and hyperspectral Atmospheric Infrared Sounder (AIRS; 01:30 LECT) observations are unable to completely resolve the GEOsat midnight BT bias. The precessing orbit of the Tropical Rainfall Measuring Mission (TRMM) Visible and Infrared Scanner (VIRS), however, allows sampling of all local hours every 46 days. Thus, VIRS has the capability to quantify the BT midnight effect observed in concurrent GEOsat imagers. First, the VIRS IR measurements are evaluated for long-term temporal stability between 2002 and 2012 by inter-calibrating with Aqua-MODIS. Second, the VIRS IR measurements are assessed for diurnal stability by inter-calibrating with Meteosat-9 (Met-9), a spin-stabilized GEOsat imager that does not manifest any diurnal dependency. In this case, the Met-9 IR imager is first adjusted with the official GSICS calibration coefficients. Then VIRS is used as a diurnal calibration reference transfer to produce hourly corrections of GEOsat IR imager BT. For the 9 three-axis stabilized GEO imagers concurrent with VIRS, the midnight effect increased the BT on average by 0.5 K (11 microns) and 0.4 K (12 microns), with a peak at approx.01:00 local time. As expected, the spin-stabilized GEOsats revealed a smaller diurnal temperature cycle (mostly < 0.2 K) with inconsistent peak hours.

Scarino, Benjamin↗

Channel to energy calibration results for the BATSE large area detectors

Continuum 16 channel spectra obtained from in flight data are used to identify and correct for nonlinearities in the channel-to-energy conversion algorithm for the BATSE large area detectors. The Crab Nebula spectra obtained by the BATSE earth occultation technique are used to characterize any nonlinearities inherent in the low energy channel bin widths on a detector by detector basis. The bin widths are optimized to remove distortions from observed gamma ray spectra. The recalibrated bin edges are used in an analysis of Crab Pulsar data to verify the improvements in the calibration.

Pendleton, Geoffrey N.↗

Calibration of the receiver channel for the GOPEX precursor experiments

Calibration measurements for the cooled (253 K) photomultiplier tube (PMT) detector, used on the receiver channel of the transmit/receive (T/R) switch for GOPEX, were conducted in the laboratory. A pulsed frequency-doubled neodymium:yttrium-aluminum-garnet (Nd:YAG) laser was used to direct 532-mn light on the PMT. By monitoring the energy per pulse of the light incident on the PMT, the minimum number of photons detected could be determined. These results agreed with the photon flux back-calculated from the PMT output waveform. Approximately 700 incident photons arriving during a temporal pulse width of approximately 65 nsec were detected with a signal-to-noise ratio (SNR) of approximately 1. Other receiver channel characteristics, such as PMT dark currents, optical transmission, and interference filter sensitivity to angle of light incidence, were also measured.

Biswas, A.↗

Revised Calibration Strategy for the CALIOP 532 nm Channel: Daytime - Part II

The CALIPSO lidar (CALIOP) makes backscatter measurements at 532 nm and 1064 nm and linear depolarization ratios at 532 nm. Accurate calibration of the backscatter measurements is essential in the retrieval of optical properties. An assessment of the nighttime 532 nm parallel channel calibration showed that the calibration strategy used for the initial release (Release 1) of the CALIOP lidar level 1B data was acceptable. In general, the nighttime calibration coefficients are relatively constant over the darkest segment of the orbit, but then change rapidly over a short period as the satellite enters sunlight. The daytime 532 nm parallel channel calibration scheme implemented in Release 1 derived the daytime calibration coefficients from the previous nighttime coefficients. A subsequent review of the daytime 532 nm parallel channel calibration revealed that the daytime calibration coefficients do not remain constant, but vary considerably over the course of the orbit, due to thermally-induced misalignment of the transmitter and receiver. A correction to the daytime calibration scheme is applied in Release 2 of the data. Results of both nighttime and daytime calibration performance are presented in this paper.

Powell, Kathleen A.↗

White-light Interferometry using a Channeled Spectrum: II. Calibration Methods, Numerical and Experimental Results

In the companion paper, [Appl. Opt. 46, 5853 (2007)] a highly accurate white light interference model was developed from just a few key parameters characterized in terms of various moments of the source and instrument transmission function. We develop and implement the end-to-end process of calibrating these moment parameters together with the differential dispersion of the instrument and applying them to the algorithms developed in the companion paper. The calibration procedure developed herein is based on first obtaining the standard monochromatic parameters at the pixel level: wavenumber, phase, intensity, and visibility parameters via a nonlinear least-squares procedure that exploits the structure of the model. The pixel level parameters are then combined to obtain the required 'global' moment and dispersion parameters. The process is applied to both simulated scenarios of astrometric observations and to data from the microarcsecond metrology testbed (MAM), an interferometer testbed that has played a prominent role in the development of this technology.

phase correction↗

Digital Calibration of TR Modules for Real-Tme Digital Beamforming SweepSAR Architectures

Real-time digital beamforming, combined with lightweight, large aperture reflectors, enable a new architecture, which is the baseline for the proposed DESDynI [Deformation, Ecosystem Structure, and Dynamics of Ice] SAR [Synthetic Aperture Radar] Instrument (or DSI). This new instrument concept requires new methods for calibrating multiple simultaneous channels. The calibration of current state-of-the-art Electronically Steered Arrays typically involves pre-flight TR (Transmit/Receive) module characterization over temperature, and in-flight correction based on measured temperatures. This method ignores the effects of element aging and any drifts unrelated to temperature. We are developing new digital calibration of digital beamforming arrays, which helps to reduce development time, risk and cost. Precision calibrated TR modules enable real-time beamforming architectures by accurately tracking modules' characteristics through closed-loop digital calibration, which tracks systematic changes regardless of temperature. The benefit of this effort is that it would enable a new, lightweight radar architecture, with on-board digital beamforming. This provides significantly larger swath coverage than conventional SAR architectures

Hoffman, James Patrick↗

Calibration of the underground muon detector of the Pierre Auger Observatory

To obtain direct measurements of the muon content of extensive air showers with energy above 10 16.5 eV, the Pierre Auger Observatory is currently being equipped with an underground muon detector (UMD), consisting of 219 10 m 2 -modules, each segmented into 64 scintillators coupled to silicon photomultipliers (SiPMs). Direct access to the shower muon content allows for the study of both of the composition of primary cosmic rays and of high-energy hadronic interactions in the forward direction. As the muon density can vary between tens of muons per m 2 close to the intersection of the shower axis with the ground to much less than one per m 2 when far away, the necessary broad dynamic range is achieved by the simultaneous implementation of two acquisition modes in the read-out electronics: the binary mode, tuned to count single muons, and the ADC mode, suited to measure a high number of them. In this work, we present the end-to-end calibration of the muon detector modules: first, the SiPMs are calibrated by means of the binary channel, and then, the ADC channel is calibrated using atmospheric muons, detected in parallel to the shower data acquisition. The laboratory and field measurements performed to develop the implementation of the full calibration chain of both binary and ADC channels are presented and discussed. The calibration procedure is reliable to work with the high amount of channels in the UMD, which will be operated continuously, in changing environmental conditions, for several years.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗