Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “channel calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Using APART for wall visibility calculations in the calibration channel of wide field planetary camera II

The cone visibility from the CCD detector array plane in the calibration channel of wide field planetary camera II (WFPC II) is analyzed, using APART, for three representative wavelengths as characterized by indices of refraction. The light pipe walls are visible from the corners of the equivalent CCD detector array when imaging with the smallest index of refraction, n = 1.375. Painting the inside of the light pipe walls will result in a decrease in their visibility.

Scholl, James W.↗

A Consistent EPIC Visible Channel Calibration using VIIRS and MODIS as a Reference

The Earth Polychromatic Imaging Camera (EPIC) aboard the Deep Space Climate Observatory (DSCOVR) satellite constantly images the sunlit disk of Earth from the Lagrange-1 (L1) point in 10 spectral channels spanning the UV, VIS, and NIR spectrums. Recently, the DSCOVR EPIC team has publicly released version 2 dataset, which has implemented improved navigation, stray-light correction, and flat-fielding of the CCD array. The EPIC 2-year data record must be well-calibrated for consistent cloud, aerosol, trace gas, land use and other retrievals. Because EPIC lacks onboard calibrators, the observations made by EPIC channels must be calibrated vicariously using the coincident measurements from radiometrically stable instruments that have onboard calibration systems. MODIS and VIIRS are best-suited instruments for this task as they contain similar spectral bands that are well-calibrated onboard using solar diffusers and lunar tracking. We have previously calibrated the EPIC version 1 dataset by using EPIC and VIIRS angularly matched radiance pairs over both all-sky ocean and deep convective clouds (DCC). We noted that the EPIC image required navigations adjustments, and that the EPIC stray-light correction provided an offset term closer to zero based on the linear regression of the EPIC and VIIRS ray-matched radiance pairs. We will evaluate the EPIC version 2 navigation and stray-light improvements using the same techniques. In addition, we will monitor the EPIC channel calibration over the two years for any temporal degradation or anomalous behavior. These two calibration methods will be further validated using desert and DCC invariant Earth targets. The radiometric characterization of the selected invariant targets is performed using multiple years of MODIS and VIIRS measurements. Results of these studies will be shown at the conference.

Haney, C. O.↗

Assessment of the Visible Channel Calibrations of the TRMM VIRS and MODIS on Aqua and Terra

Several recent research satellites carry self-calibrating multispectral imagers that can be used for calibrating operational imagers lacking complete self-calibrating capabilities. In particular, the visible (VIS, 0.65 m) channels on operational meteorological satellites are generally calibrated before launch, but require vicarious calibration techniques to monitor the gains and offsets once they are in orbit. To ensure that the self-calibrating instruments are performing as expected, this paper examines the consistencies between the VIS channel (channel 1) reflectances of the Moderate Resolution Imaging Spectroradiometer (MODIS) instruments on the Terra and Aqua satellites and the Version 5a and 6 reflectances of the Visible Infrared Scanner (VIRS) on the Tropical Rainfall Measuring Mission using a variety of techniques. These include comparisons of Terra and Aqua VIS radiances with coincident broadband shortwave radiances from the well-calibrated Clouds and the Earth s Radiant Energy System (CERES), time series of deep convective cloud (DCC) albedos, and ray-matching intercalibrations between each of the three satellites. Time series of matched Terra and VIRS data, Aqua and VIRS data, and DCC reflected fluxes reveal that an older version (Version 5a, ending in early 2004) of the VIRS calibration produced a highly stable record, while the latest version (Version 6) appears to overestimate the sensor gain change by approx.1%/y as the result of a manually induced gain adjustment. Comparisons with the CERES shortwave radiances unearthed a sudden change in the Terra MODIS calibration that caused a 1.17% decrease in the gain on 19 November 2003 that can be easily reversed. After correction for these manual adjustments, the trends in the VIRS and Terra channels are no greater than 0.1%/y. Although the results were more ambiguous, no statistically significant trends were found in the Aqua MODIS channel-1 gain. The Aqua radiances are 1% greater, on average, than their Terra counterparts, and after normalization are 4.6% greater than VIRS radiances, in agreement with theoretical calculations. The discrepancy between the two MODIS instruments should be taken into account to ensure consistency between parameters derived from them. With the adjustments, any of the three instruments can serve as references for calibrating other satellites. Monitoring of the calibrations continues in near-real-time and the results are available via the world wide web.

Minnis, Patrick↗

Visible and near-infrared channel calibration of the GOES-6 VISSR using high-altitude aircraft measurements

Present and future visible and near-infrared wavelength sensors mounted on operational satellites do not have on-board absolute calibration devices. One means of establishing an in-orbit calibration for a satellite sensor is to make simultaneous measurements of a bright, relatively uniform scene along the satellite view vector from a calibrated instrument on board a high altitude aircraft. Aircraft data were recorded over White Sands, New Mexico, and the coincident aircraft and orbiting satellite data is compared for the visible and near-infrared wavelength channel of the GOES-6 Visible Infrared Spin-Scan Radiometer.

Smith, Gilbert R.↗

Active-passive airborne ocean color measurement. I - Instrumentation

The instrumentation used in a multichannel lidar fluorosensor spectrometer functioning concurrently as a passive spectroradiometer for measuring upwelling ocean color radiance is discussed. The instrument calibration techniques are addressed, including the absolute passive calibration technique, the importance of relative channel-to-channel calibration for accurate ocean color measurement, and active mode calibration techniques using passive calibration transfer methods. Ground and flight test results from the dual-mode active-passive ocean color sensor are discussed.

Hoge, F. E.↗

EOS MLS Level 1B Data Processing Software

This software is an improvement on Version 2, which was described in EOS MLS Level 1B Data Processing, Version 2.2, NASA Tech Briefs, Vol. 33, No. 5 (May 2009), p. 34. It accepts the EOS MLS Level 0 science/engineering data, and the EOS Aura spacecraft ephemeris/attitude data, and produces calibrated instrument radiances and associated engineering and diagnostic data. This version makes the code more robust, improves calibration, provides more diagnostics outputs, defines the Galactic core more finely, and fixes the equator crossing. The Level 1 processing software manages several different tasks. It qualifies each data quantity using instrument configuration and checksum data, as well as data transmission quality flags. Statistical tests are applied for data quality and reasonableness. The instrument engineering data (e.g., voltages, currents, temperatures, and encoder angles) is calibrated by the software, and the filter channel space reference measurements are interpolated onto the times of each limb measurement with the interpolates being differenced from the measurements. Filter channel calibration target measurements are interpolated onto the times of each limb measurement, and are used to compute radiometric gain. The total signal power is determined and analyzed by each digital autocorrelator spectrometer (DACS) during each data integration. The software converts each DACS data integration from an autocorrelation measurement in the time domain into a spectral measurement in the frequency domain, and estimates separately the spectrally, smoothly varying and spectrally averaged components of the limb port signal arising from antenna emission and scattering effects. Limb radiances are also calibrated.

Perun, Vincent S.↗

Procedures to validate/correct calibration error in solar backscattered ultraviolet instruments

The Nimbus 7 SBUV measures the same latitude ozone at widely different sun angle conditions at the ascent and descent part of the orbit during the summer solstice. This situation is used in a particular procedure (Ascent/Descent) to obtain the relative channel-to-channel calibration error for channels 273 nm to 306 nm. These estimated errors are combined with results from the Pair Justification procedure to correct the sun-view diffuser drift in calibration from November 1978 to February 1987 for the shorter wavelength channels that measure upper stratospheric ozone. Some preliminary re-calirated Nimbus 7 SBUV data in 1989 is compared with the first set of SBUV measurements flown on the Space Shuttle.

Taylor, Steven L.↗

The Calibration of AVHRR/3 Visible Dual Gain Using Meteosat-8 as a MODIS Calibration Transfer Medium

This viewgraph presentation reviews the NOAA-17 AVHRR visible channels calibrated against MET-8/MODIS using dual gain regression methods. The topics include: 1) Motivation; 2) Methodology; 3) Dual Gain Regression Methods; 4) Examples of Regression methods; 5) AVHRR/3 Regression Strategy; 6) Cross-Calibration Method; 7) Spectral Response Functions; 8) MET8/NOAA-17; 9) Example of gain ratio adjustment; 10) Effect of mixed low/high count FOV; 11) Monitor dual gains over time; and 12) Conclusions

Avey, Lance↗

On the use of DSCOVR EPIC to monitor the visible calibration stability of polar orbiting imagers to improve the next edition of the CERES climate data record.

The NASA CERES project has provided the climate quality observed TOA and computed surface fluxes to the scientific community. CERES instruments are onboard the Terra, Aqua, NPP, and NOAA-20 spacecraft. CERES uses MODIS and VIIRS imagers to retrieve cloud properties needed to convert CERES footprint radiance observations into fluxes using empirically derived angular directional models obtained during early CERES record. CERES utilizes geostationary sensors to infer the regional diurnal fluxes in between Terra and Aqua CERES observations. The imagers are also used to radiometrically scale the geostationary sensors (GEO) radiances to the imager calibration reference to ensure that the GEO derived cloud properties and broadband TOA fluxes are consistent in both space and time. Both the imager and GEO retrieved cloud properties are used to compute the surface fluxes. The Aqua-MODIS, SNPP-VIIRS, and NOAA-20 VIIRS afternoon imagers will also need to be radiometrically scaled to the same common calibration reference. Although all three imagers employ onboard solar diffusers, the calibration is not consistent over time due to instrument anomalies and ageing of the onboard calibrators. The CERES imager and GEO calibration group (IGCG) has been tasked to remove the imager channel calibration drifts for the next CERES reprocessing effort. The team will rely primarily on deep convective clouds, desert, and polar ice invariant targets to monitor the imager channel stability. The team uses ray-matched radiance pairs to radiometrically scale the SNPP and NOAA-20 VIIRS sensors to Aqua-MODIS. The radiometric scaling is further validated using geostationary imagers as transfer radiometers. The DSCOVR satellite was launched on February 25, 2015 and orbits around the L1 Lagrange point directly between the Earth and the sun. The EPIC instrument onboard DSCOVR employs a CCD array to image the Earth approximately every 2-hours. The EPIC sensor contains no onboard calibration systems. However, multiple inter-calibration studies have shown that the EPIC imager is very stable in time. This is likely due to the DSCOVR satellite being located about a 1.5M km from the Earth, where very little Earth reflected solar radiation degrades the optics. The excellent radiometric stability of EPIC allows the CERES IGCG to utilize the EPIC observations as a stable reference for monitoring the calibration stability of the three afternoon imagers, as well as to validate the radiometric scaling factors between them. Examples of the imager relative calibration using EPIC before and after radiometric scaling will be shown along with the results from the use of invariant targets to remove imager calibration drifts.

DSCOVR-EPIC↗

Shuttle extravehicular activity signal processor pulse amplitude modulation decommutator

To provide data with long-term stability and accuracy, the pulse amplitude modulation (PAM) decommutator was synchronized to the PAM-return to zero wavetrain, and each channel was sampled with a common sample and hold circuit and digitized sequentially. The digital value of each channel was then scaled by the digital value of the calibration channels. The corrected digital value of each channel was stored for one complete frame and then transferred to the multiplexer-demultiplexer at a high rate in one block of serial digital data. A test model was built to demonstrate this design approach taken for the PAM decom and performance data was provided. The accuracies obtained with various signal to noise ratios are shown.

Noble, D. E.↗

Calibration strategy of the PROSPECT-II detector with external and intrinsic sources

This paper presents an energy calibration scheme for an upgraded reactor antineutrino detector for the Precision Reactor Oscillation and Spectrum Experiment (PROSPECT). The PROSPECT collaboration is preparing an upgraded detector, PROSPECT-II (P-II), to advance capabilities for the investigation of fundamental neutrino physics, fission processes and associated reactor neutrino flux, and nuclear security applications. P-II will expand the statistical power of the original PROSPECT (P-I) dataset by at least an order of magnitude. The new design builds upon previous P-I design and focuses on improving the detector robustness and long-term stability to enable multi-year operation at one or more sites. The new design optimizes the fiducial volume by elimination of dead space previously occupied by internal calibration channels, which in turn necessitates the external deployment. In this paper, we describe a calibration strategy for P-II. Here, the expected performance of externally deployed calibration sources is evaluated using P-I data and a well-benchmarked simulation package by varying detector segmentation configurations in the analysis. The proposed external calibration scheme delivers a compatible energy scale model and achieves comparable performance with the inclusion of an additional AmBe neutron source, in comparison to the previous internal arrangement. Most importantly, the estimated uncertainty contribution from the external energy scale calibration model meets the precision requirements of the P-II experiment.

47 OTHER INSTRUMENTATION↗

The Impact of Pixel Size on the Characterization of Deep Convective Clouds for Calibration

The NASA CERES project provides the scientific community the observed TOA SW and LW fluxes for climate monitoring and climate model validation. CERES utilizes hourly geostationary imager derived broadband fluxes, which rely on the channel radiances and associated cloud retrievals, to estimate the broadband fluxes between CERES observations. This requires stable imager visible channel calibration, which the CERES project verifies by utilizing deep convective clouds (DCC) as an invariant Earth target. GSICS, which is an international collaboration, is also evaluating the DCC invariant target calibration methodology to provide consistent calibration coefficients across geostationary imagers anchored to the Aqua-MODIS calibration reference. Tropical DCC are the brightest, coldest, most Lambertian, top of the atmosphere Earth targets. The DCC invariant target calibration methodology relies on a large ensemble of tropical DCC-identified pixel-level reflectances, which are histogrammed to find the mode reflectance of the probability density function (PDF). The imager stability is monitored by tracking the monthly DCC PDF mode reflectance over time. Radiometric scaling is accomplished by ratioing the GEO and VIIRS DCC mode reflectance values. The PDF shape and mode dependency on sensor pixel resolution, which varies among sensors, is unknown. This study will characterize the impact of pixel resolution on the DCC PDFs by aggregating Landsat 30-m pixel reflectances into various coarser pixel resolutions ranging from 100-m to 4-km, and comparing the corresponding PDF statistics. This analysis will assist in improving the uncertainty in a DCC-based intercalibration between instruments with different pixel resolutions.

Conor Haney↗

The Impact of Pixel Size on the Characterization of Deep Convective Clouds for Calibration

The NASA CERES project provides the scientific community the observed TOA SW and LW fluxes for climate monitoring and climate model validation. CERES utilizes hourly geostationary imager derived broadband fluxes, which rely on the channel radiances and associated cloud retrievals, are used to estimate the broadband fluxes between CERES observations. This requires stable and consistent cross-platform imager visible channel calibration. The CERES project utilizes deep convective clouds (DCC) as an invariant Earth target to both monitor the stability of sensors and for radiometric scaling. GSICS, an international collaboration, is also evaluating and implementing the DCC invariant target calibration methodology to provide consistent calibration coefficients across geostationary imagers anchored to the AquaMODIS or the NOAA-20 VIIRS calibration reference. Tropical DCC are the brightest, coldest, most Lambertian, top of the atmosphere Earth targets. The DCC invariant target calibration methodology relies on a large ensemble of tropical D CC-identified pixel-level reflectances, which are aggregated as probability density functions (PDF). By assuming the monthly PDF shape is otherwise consistent in time excepting shifts in reflectance caused by changes in the sensor calibration, the imager stability is monitored. Radiometric scaling is accomplished by ratioing the sensor pair DCC PDF reflectance values. The success of the DCC methodology relies on consistent PDF distributions. The goal of this study is to determine the impact of pixel resolution on the DCC reflectance distribution. Single SNPP-VIIRS 750-m and Landsat 8 OLI 30-m granules are aggregated to degrade the pixel resolution from the native level. The DCC pixels are identified using a BT threshold. Most of the brightest DCC pixels are also the coldest, although there are exceptions. It was found that increasing the BT threshold exponentially increased the number of darker pixels. The pixel resolution did not seem to impact the DCC reflectance PDF distribution for pixel resolutions less than 3 km, which suggests that imagers of varying pixel resolutions may be radiometrically scaled to each other using DCC targets.

DCC↗

The Radiometric Scaling of the MODIS and VIIRS Imagers to a Common Reference and Stability Analysis for the Next Edition of CERES Products

The NASA CERES project has provided the climate quality observed TOA and computed surface fluxes to the scientific community. CERES uses MODIS and VIIRS imagers to retrieve cloud properties needed to convert Terra, Aqua, NPP, and NOAA-20 CERES footprint radiance observations into fluxes. The imagers are also used to radiometrically scale the geostationary sensors (GEO) radiances to the imager calibration reference to ensure that the GEO derived cloud properties and broadband TOA fluxes are consistent in both space and time. Both the imager and GEO retrieved cloud properties are used to compute the surface fluxes. The CERES imager and GEO calibration team uses ray-matched radiance pairs to radiometrically scale the SNPP and NOAA-20 VIIRS sensors to the Aqua-MODIS calibration reference. The radiometric scaling is further validated using geostationary imagers as transfer radiometers. The team will rely primarily on deep convective clouds to monitor the imager channel calibration stability and to correct for short term calibration drifts. The DSCOVR satellite was launched on February 25, 2015 and orbits around the L1 Lagrange point directly between the Earth and the sun. The EPIC sensor contains no onboard calibration systems. However, multiple inter-calibration studies have shown that the EPIC imager is very stable in time. The excellent radiometric stability of EPIC allows the use of EPIC observations as a stable reference to validate both the short term drift corrections of the imagers, as well as to validate the radiometric scaling factors between them. Examples of the imager relative calibration using EPIC before and after radiometric scaling will be shown along with the results from the use of invariant targets to remove imager calibration drifts.

DSCOVR-EPIC↗

CALIPSO Lidar Calibration at 532 nm: Version 4 Nighttime Algorithm

Data products from the Cloud-Aerosol Lidar with Orthogonal Polarization (CALIOP) on board Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observations (CALIPSO) were recently updated following the implementation of new (version 4) calibration algorithms for all of the level 1 attenuated backscatter measurements. In this work we present the motivation for and the implementation of the version 4 nighttime 532 nm parallel channel calibration. The nighttime 532 nm calibration is the most fundamental calibration of CALIOP data, since all of CALIOP’s other radiometric calibration procedures – i.e., the 532 nm daytime calibration and the 1064 nm calibrations during both nighttime and daytime – depend either directly or indirectly on the 532 nm nighttime calibration. The accuracy of the 532 nm nighttime calibration has been significantly improved by raising the molecular normalization altitude from 30-34 km to 36-39 km to substantially reduce stratospheric aerosol contamination. Due to the greatly reduced molecular number density and consequently reduced signal-to-noise ratio (SNR) at these higher altitudes, the signal is now averaged over a larger number of samples using data from multiple adjacent granules. As well, an enhanced strategy for filtering the radiation-induced noise from high energy particles was adopted. Further, the meteorological model used in the earlier versions has been replaced by the improved MERRA-2 model. An aerosol scattering ratio of 1.01 ± 0.01 is now explicitly used for the calibration altitude. These modifications lead to globally revised calibration coefficients which are, on average, 2-3% lower than in previous data releases. Further, the new calibration procedure is shown to eliminate biases at high altitudes that were present in earlier versions and consequently leads to an improved representation of stratospheric aerosols. Validation results using airborne lidar measurements are also presented. Biases relative to collocated measurements acquired by the Langley Research Center (LaRC) airborne high spectral resolution lidar (HSRL) are reduced from 3.6% ± 2.2% in the version 3 data set to 1.6% ± 2.4 % in the version 4 release.

Jayanta Kar↗

Statistical Partial Calibration Of Polarimetric SAR Imagery

Mathematical technique for partial calibration of quadpolarization synthetic-aperture-radar (SAR) image data makes possible to remove partially those contaminating cross-polarization effects (crosstalk) arising in antenna(s) and/or other transmitting and receiving channels. Quadpolarization data processed with help of technique better approximates backscattering properties of target area. If corner reflectors or other known discrete radar targets placed in target area, all of data channels calibrated both relatively to each other and absolutely.

Klein, Jeffrey D.↗

TPSAS-NF1676L-10863-DND

One important aspect of successful climate monitoring is satellite calibration. There is at least a 25-year of operational geostationary (GEO) record available for climate studies, if properly calibrated. The Global Space-based Inter-Calibration System (GSICS) project is another effort to provide the climate community consistent calibration across multiple platforms. Also, the Clouds and the Earth's Radiant Energy System (CERES) project, provides consistent GEO retrieved cloud properties and derived broadband fluxes across multiple platforms. This year GSICS is focusing on geostationary visible channel calibration. The GSICS strategy is to use multiple approaches, such as cross-calibrating the GEO radiances against MODIS as a reference, deep convective clouds as bright stable targets, deserts, sun-glint, stars, moon and other model based calibration methods. Each of these methods is independent of each other and can assess the stability of the GEO visible instrument with differing uncertainties. This study focuses on the inter-calibration of the GEO radiances against MODIS as a reference by using collocated, and coincident ray-matched radiances. The advantage of the ray-matching technique is that it provides a full dynamic range of radiances to check the linearity of the GEO visible instrument. This presentation will focus on the technique, some error analysis, comparisons with other methods, and an approach to inter-calibrate historical GEOs before MODIS.

D R Doelling↗